• Title/Summary/Keyword: trimmed surface

Search Result 51, Processing Time 0.033 seconds

Computed tomography investigation of the three-dimensional structure and production method of White Porcelain Water Dropper with Openwork Lotus Scroll Design and Eight Trigram Design in Cobalt-blue Underglaze (CT 조사를 통한 청화백자투각연당 초팔괘문연적의 3차원적 구조와 제작방법에 대한 고찰)

  • Na, Ahyoung;Hwang, Hyunsung
    • Conservation Science in Museum
    • /
    • v.25
    • /
    • pp.1-8
    • /
    • 2021
  • This study investigated White Porcelain Water Dropper with Openwork Lotus Scroll Design and Eight Trigram Design in Cobalt-blue Underglaze (hereinafter, the "water dropper") in the collection of the National Museum of Korea using computed tomography (CT). A replica was produced to examine both the structure and its original production method. The CT scanning identified no joint lines or pores in the clay, which suggests that the body (the lower part of the water dropper) was shaped in a single piece using a mold and was then matched with a mold-formed lid (the upper part of the water dropper). The inner container of the body portion was roughly trimmed with a bamboo knife so that its upper surface could be securely attached to the bottom of the lid and prevent any leakage in the joined surface. It appears that the inner container for storing water was made first in a cylindrical shape that met the unit of quantity used at the time and could be easily formed by molding. It was transformed into a trapezoid shape during the process of combining it with the lid. A cylindrical inner container was reproduced using silicon 3D printing to compare its capacity with that of the original inner container. The comparison revealed that the reproduced container had a capacity of 152.5㎖, whereas the original container holds approximately 168.6㎖, a figure similar to three hop (around 174㎖) in Joseon-period units of quantity. Since the capacity of the cylindrical inner container corresponds to a known measure from the late Joseon dynasty, it is likely that the water dropper was originally produced to contain a cylindrical inner container.

DIFFERENCE IN BOND STRENGTH ACCORDING TO FILLING TECHNIQUES AND CAVITY WALLS IN BOX-TYPE OCCLUSAL COMPOSITE RESIN RESTORATION (박스 형태의 복합레진 수복시 충전법 및 와동벽에 따른 결합력 차이에 관한 연구)

  • Ko, Eun-Joo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.350-355
    • /
    • 2009
  • Bond strength depends on characteristics of bonding surface and restorative technique. The majority of studies dealing with dentin bond strength were carried out on flat bonding surface, therefore, difference of bond strength between axial wall and pulpal wall is not clear yet. This study evaluated bonding difference between cavity walls in class I composite resin restoration with different filling techniques. Twenty extracted caries-free human third molars were used. Cavities were prepared in 6 ${\times}$4 ${\times}$3 mm box-type and divided into four groups according to filling technique and bonding surface: Group I; bulk filling - pulpal wall, Group II; bulk filling - axial wall, Group III; incremental filling - pulpal wall, Group IV; incremental filling - axial wall. Cavities were filled with Filtek $Z250^{(R)}$(3M/ESPE., USA) and Clearfill SE $bond^{(R)}$(Kuraray, Japan). After 24 hour-storage in $37^{\circ}C$water, the resin bonded teeth were sectioned bucco-lingualy at the center of cavity. Specimens were vertically sectioned into 1.0 ${\times}$1.0 mm thick serial sticks perpendicular to the bond surface using a low-speed diamond saw (Accutom 50, Struers, Copenhagen, Denmark) under water cooling. The trimmed specimens were then attached to the testing device and in turn, was placed in a universal testing machine (EZ test, Shimadzu Co., Kyoto, Japan) for micro-tensile testing at a cross-head speed of 1 mm/min. The results obtained were statistically analyzed using 2-way ANOVA and t-test at a significance level of 95%. The results were as follows: 1. There was no significant difference between bulk filling and incremental filling. 2. There was no significant difference between pulpal wall and axial wall, either. Within the limit of this study, it was concluded that microtensile bond strength was not affected by the filling technique and the site of cavity walls.

A Fundamental Study of the Armors of the Missionsmuseum St. Ottilien in Germany (독일 상트 오틸리엔 선교분도수도원 선교박물관 소장 갑옷에 관한 기초연구)

  • Cho, Woo Hyun;Yum, Jung Ha;Beckers-Kim, Young Ja
    • Journal of the Korean Society of Costume
    • /
    • v.65 no.3
    • /
    • pp.76-90
    • /
    • 2015
  • This is a basic study of the two remaining armors (artifacts number K2366, K2368) from the late Joseon dynasty that is part of the Korean costume collection, which is preserved in the Mission Museum of Saint Ottilien in Germany. The armor No. 1 (artifacts number K2366) is a coat-styled armor with brass studs. It has a U-shaped neckline with the non-overlapping collars and sleeve straight-lined inseam. The armor No. 1 has the Mu to the sides and is not back slit. Both its inner and outer material are padded with cotton. Leather mails are attached on the inner lining, and studs are attached on the outer lining to match the leather mails. For this reason, the armor No. 1 can be named MyeonPiGab (brass studded armor consisting of a cotton coat with internal leather mails). The outer material is faded to have the natural white, or antique white look and the patterns on it are indigo blue. The inner material is blue, but the original color is unknown since it is faded. The lotus blossoms and vine patterns are dyed on the surface of the outer material and a name is written on the inner material. The armor No. 1 was worn between the late 17th century and the 19th century. It is estimated that it was worn by military officers who were above the mid-rank in the end of the Joseon dynasty. The armor No. 2 (artifacts number K2368) is a coat-styled armor with brass studs and a low-cut U-shaped neckline. The armor No. 2 has a slit on the left armpit and a string around it. Studs are evenly attached on the armor. The iron mails are attached to the left chest area on its inner lining. It seems that it was designed with both formality and functionality in mind. The outer material is red flannel, the inner material is blue satin and the pads are cheesecloth. The side of its collars, cuffs, front lines, sidelines, back slit, and bottom lines are trimmed with fur. There are armors called "JeonCheolGap (brass studded armor consisting of a felt coat with internal iron mails)," which is similar to the armor No. 2, however, the similarities are limited because they are not made of the same material nor do they follow the same principle of nomenclature.

Nutrient Uptake by Reeds Growing in Subsurface-flow Wetland Constructed to Purify Stream Water (하천수정화 여과습지에서 성장하는 갈대의 영양염류 흡수량)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.1
    • /
    • pp.89-99
    • /
    • 2006
  • The growth and biomass of reeds(Phragmites australis) growing in a subsurface treatment wetland system were investigated from April 2003 to October 2003. Nitrogen(N) and phosphorous(P) concentrations in above-ground(AG) and below-ground(BG) tissues of reeds were examined and the removal rate of N and P by reeds were analyzed. The system, 29 m in length, 9 m in width and 0.65 m in depth, was constructed in June 2001 on a floodplain in the down reach of the Kwangju Stream in Korea in order to purify polluted water of the stream. A bottom layer of 45 cm in depth was filled with crushed granites(15~30 mm in diameter) and a middle layer of 10 cm in depth was filled with pea pebbles(10 mm in diameter). An upper layer of 5 cm contained course sand. Reeds were transplanted on the surface of the system, which were dug out of natural wetlands, and their shoots were trimmed 40 cm in height. The height and density of the shoots averaged 237.7 cm and 244.0 shoot/$m^2$, respectively, when the reeds grew fully. The maximum biomass of AG and BG tissues were 1,964 and 1,577 g/$m^2$, respectively, and the AG : BG ratio of biomass was 1.26. Mean AG and BG dry weights were recorded as 1,355 and 748 g/$m^2$, respectively. The AG and BG tissue concentrations of N averaged 12.37 and 10.01 mg/g, respectively, and those of P 2.37 and 2.03 mg/g, respectively. Inflow to the system averaged 40 $m^3$/day. The concentrations of total nitrogen(T-N) in influent and effluent were 8.4 mg/L and 3.2 mg/L, respectively, and those of total phosphorous(T-P) were 0.73 and 0.38 mg/L, respectively. The total removal of T-N and T-P by the system during the investigation period averaged 140.2 and 9.7 g/$m^2$, respectively, and the total uptake of N and P by the reeds were calculated as 24.39 and 4.73 g/$m^2$, respectively. Average removals of about 17% of N and about 49% of P by reeds were recorded. The N and P concentrations in AG tissues were significantly different among the three zones of the system:near to inflow(St1), in the middle of system(St2), and near to outflow(St3). The N and P concentrations in BG tissues were also significantly different among St1, St2 and St3. N and P concentrations in AG and BG tissues of reeds growing in St1 were higher than those in St2 and St3. The height and density of shoots of reeds in St1 were larger than those in St2 and St3. Significant amounts of N and P in the influent were taken up by reeds in St1.

Three Dimensional Analysis of Primary Maxillary Central and Lateral Anterior Zirconia Crown (상악 유절치 지르코니아 전장관 수복을 위한 3차원 분석)

  • Lee, Jungmin;Lee, Hyoseol;Nam, Okhyung;Kim, Misun;Choi, Sungchul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.2
    • /
    • pp.176-186
    • /
    • 2016
  • This study was performed to compare the shape and dimension of anterior zirconia crowns to other pediatric crowns using a three-dimensional scanner to investigate adequate amount of tooth preparation. Primary central and lateral anterior zirconia crowns, stainless steel crowns and celluloid strip crowns were scanned by a three-dimensional scanner. Outer and inner surfaces of zirconia and stainless steel crowns, and outer surface of celluloid strip crowns were analyzed. In outer scanned images, all sizes of central and lateral size 1 zirconia crown had the largest labiolingual diameter among the three crowns. In inner scanned images, zirconia crown's mesiodistal diameter was 0.7-1.0 mm smaller and crown length was approximately 1 mm shorter than those of stainless steel crowns. Zirconia crown's labiolingual diameter was larger in central crowns whereas it was smaller in lateral crowns than that of stainless steel crowns. Recommended preparation required for zirconia crown is incisal 2.5-3.0 mm, mesiodistal 1.5-2.0 mm, labial 0.5-1.0 mm. Cingulum should be trimmed parallel to the long axis. No more lingual reduction is needed in central incisors whereas additional 0.5 mm reduction is suggested in lateral incisors.

Acceleration of Integra Incorporation in Reconstruction of Burn Scar Contracture with The Vacuum-Assisted Closure(VAC) (Integra®를 이용한 화상 반흔 구축 재건에 있어 Vacuum-Assisted Closure(VAC)의 유용성)

  • Oh, Suk Joon;Jeon, Man Kyung;Ko, Sung Hoon
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.432-436
    • /
    • 2009
  • Purpose: Negative pressure therapy has been used in various conditions to promote wound healing. It has also been used to secure a skin graft by improving microcirculation and improving tight adhesion between the graft and the recipient bed. To reduce post burn scar contracture and improve aesthetical result, many types of dermal substitutes have been invented and used widely. The goal of this study was evaluate usefulness of the VAC (Kinetic concepts Inc., San Antonio, TX) in improving the take rate and time to incorporation of Integra$^{(R)}$ in reconstruction of burn scar contracture. Methods: A retrospective study was performed from October, 2006 to December, 2008. The VAC was utilized for 11 patients. The average patient's age was 19.7 years (range 5 - 27) and average surface area was $785cm^2$ (range 24 - 1600). The burn scars were excised deep into normal subcutaneous tissue to achieve complete release of the scar, Integra$^{(R)}$ was sutured in place with skin staple와 Steri - strip$^{(R)}$. Then slit incisions were made on silicone sheet only with No.11 blade for effective drainage. The VAC was used as a bolster dressing over Integra$^{(R)}$. Negative - Pressure ranging from 100 to 125 mm Hg was applied to black polyurethane foam sponge trimmed to the appropriate wound size. An occlusive seal over the black polyurethane foam sponge was maintained by a combination of the occlusive dressing, OP - site$^{(R)}$. The VAC dressing changes were performed every 3 or 4 days until adequate incorporation was obtained. The neodermis appeared slightly yellow to orange color. When the Integra$^{(R)}$ deemed clinically incorporated, The VAC was removed and take was estimated with visual inspection. Very thin STSG(0.006 ~ 0.008 inches) was performed after silicone sheet removal. Result: The mean time for clinically assessed incorporation of Integra$^{(R)}$ was 10.00 days (range 9 - 12). The mean dressing change was 3.5 times until take was obtained. In All patients, Integra$^{(R)}$ had successful incorporation in tissue without serious complications. Conclusion: Integra$^{(R)}$ in combination with Vacuum - Assisted Closure(VAC) may be incorporated earlier than conventional dressing method.

Storage stability of dry-aged beef: the effects of the packaging method and storage temperature

  • Choe, Juhui;Kim, Kwan Tae;Lee, Hyun Jung;Oh, Jungmin;Kim, Hyun Cheol;Park, Bumjin;Choi, Yang Il;Jo, Cheorun
    • Korean Journal of Agricultural Science
    • /
    • v.45 no.2
    • /
    • pp.211-218
    • /
    • 2018
  • Different packaging methods and storage temperatures were tested to determine the storage stability of beef dry-aged for 21 days based on microbial, physicochemical, and sensory qualities. After completion of the dry aging, the dried surface of beef sirloin was trimmed off, and the beef was packaged using two different methods (oxygen-permeable wrap or vacuum packaging) and stored at different temperatures ($3{\pm}2^{\circ}C$ or $-23{\pm}2^{\circ}C$) for 0, 7, 14, or 21 days. Lipid oxidation and the sensory quality of the dry-aged beef were not affected by the packaging method and storage temperature during storage. No microbial growth was observed over the storage period in the vacuum-packaged dry-aged beef, regardless of the storage temperature. However, dry-aged beef in the oxygen-permeable wrap packaging showed microbial spoilage with 8.82 log CFU / g at day 7 of the refrigerated storage. The vacuum-packaged dry-aged beef showed the lowest values (p < 0.05) in $a^*$ and chroma at days 14 and 21 at $3^{\circ}C$, and days 7 and 14 at $-23^{\circ}C$, respectively. Therefore, it is recommended that dry-aged beef with wrap packaging stored in refrigerated conditions should be consumed as quickly as possible due to microbial growth. For long-term storage, dry-aged beef should be frozen because freezing can extend the color stability up to day 21 of storage without adverse effects on the hygienic or meat quality aspects of dry-aged beef.

Concept and application of implant connection systems: Part II. Placement and restoration of external connection implant and tissue level implant (임플란트 연결부의 개념과 적용: Part 2. 안착형 외부 및 내부 연결형 임플란트의 식립과 보철)

  • Ko, Kyung-Ho;Kang, Hyeon-Goo;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.222-231
    • /
    • 2020
  • To use the external connection implant (EXT) appropriately, the inter-implant distance should be carefully considered during placement, and the bones raised above the implants should be trimmed during the second surgery. The hex abutment is more useful than the non-hex abutment. EXT is particularly useful when the inter-arch space is limited. The tissue level (TL, internal butt connection) implant has a biomechanical advantage of coronal wall thickness and a biological advantage of an inherent transmucosal smooth surface. During TL implant restoration, an abutment can be selected using the abutment and fixture margins with considerations for the inter-arch space. Since no single type of implant can satisfy all the cases, it is necessary to select the appropriate type, considering the occlusal force and the bone condition.

Fabrication of fixed prosthesis by employing functionally generated path technique and dual scan technique in a tardive dyskinesia patient: a case report (지연성 운동이상증 환자에서 functionally generated path 술식과 이중스캔법을 이용한 고정성 보철물 제작: 증례 보고)

  • Shilpa;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.227-233
    • /
    • 2023
  • Tardive dyskinesia is an involuntary neurological movement disorder caused by long-term use of dopamine receptor-blocking drugs leading to dental implications like uncontrolled gnashing and grinding of teeth which in turn imperil the oral rehabilitation procedures as the excessive load increases the risk of prosthesis fracture. A 40-year male with a medical history of tardive dyskinesia visited the hospital to receive oral rehabilitation for missing maxillary anterior teeth. After the oral examination, tooth preparation was done on teeth 13, 15, and 23. After that silicon impression was made and the gypsum cast was digitalized using a desktop scanner and an interim prosthesis was fabricated by milling a resin block. During the try-in, the occlusal one-third of the interim prosthesis was trimmed, and an auto-polymerizing acrylic resin was applied on the occlusal surfaces and inserted in the patient's mouth. Then, the functionally generated path (FGP) of occluding surfaces of opposing arches was traced on the resin surface. When the resin was hardened, the modified interim prosthesis was removed and digitized using an intraoral scanner. The scan image was used in designing the occlusal morphology of definitive prosthesis by modifying the design of the interim prosthesis using the dual scan method. Lastly, a monolithic zirconia prosthesis was fabricated by milling a zirconia block. The definitive prosthesis was delivered reflecting the patient's occlusal scheme. This case report shows that the FGP technique with the dual scan method can help in fabricating fixed prosthesis with harmonious occlusion in a tardive dyskinesia patient.

The Influence of AH-26 and Zinc Oxide-Eugenol Root Canal Sealer on the Shear Bond Strength of Composite Resin to Dentin (AH-26 및 산화아연유지놀 근관실러가 상아질에 대한 복합레진의 전단결합강도에 미치는 영향)

  • Cho, Ju-Yeon;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.3
    • /
    • pp.147-152
    • /
    • 2006
  • The purpose of this study was to evaluate the influence of the AH-26 root canal sealer on the shear bond strength of composite resin to dentin. One hundred and forty four (144) extracted, sound human molars were used. After embedding in a cylindrical mold, the occlusal part of the anatomical crown was cut away and trimmed in order to create a flat dentin surface. The teeth were randomly divided into three groups; the AH-26 sealer was applied to the AH-26 group, and zinc-oxide eugenol (ZOE) paste was applied to the ZOE group. The dentin surface of the control group did not receive any sealer. A mount jig was placed against the surface of the teeth and the One-step dentin bonding agent was applied after acid etching. Charisma composite resin was packed into the mold and light cured. After polymerization, the alignment tube and mold were removed and the specimens were placed in distilled water at $37^{\circ}C$ for twenty four hours. The shear bond strength was measured by an Instron testing machine. The data for each group were subjected to one-way ANOVA and Tukey's studentized rank test so as to make comparisons between the groups. The AH-26 group and the control group showed significantly higher shear bond strength than the ZOE group (p<0.05). There were no significant differences between the AH-26 group and the control one (p>0.05). Under the conditions of this study, the AH-26 root canal sealer did not seem to affect the shear bond strength of the composite resin to dentin while the ZOE sealer did. Therefore, there may be no decrease in bond strength when the composite resin core is built up immediately after a canal filling with AH-26 as a root canal sealer.