• Title/Summary/Keyword: treatment planning

Search Result 1,821, Processing Time 0.03 seconds

Measurement of Skin Dose for Rectal Cancer Patients in Radiotherapy using Optically Stimulated Luminescence Detectors (OSLDs) (광자극발광선량계(OLSDs)를 이용한 직장암 방사선치료 환자의 피부선량 측정)

  • Im, In-Chul;Yu, Yun-Sik;Lee, Jae-Seung
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.86-92
    • /
    • 2011
  • This study used the optically stimulated luminescence dosimeters (OSLDs), recently, received the revaluation of usefulness in vivo dosimetry, and the diode detecters to measure the skin dose of patient with the rectal cancer. The measurements of dose delivered were compared with the planned dose from the treatment planning system (TPS). We evaluated the clinical application of OSDs in radiotherapy. We measured the calibration factor of OSLDs and used the percent depth dose to verified, also, we created the three point of surface by ten patients of rectal cancer to measured. The calibration factors of OSLD was 1.17 for 6 MV X-ray and 1.28 for 10 MV X-ray, demonstrating the energy dependency of X-ray beams. Comparison of surface dose measurement using the OSLDs and diode detectors with the planned dose from the TPS, The skin dose of patient was increased 1.16 ~ 2.83% for diode detectors, 1.36 ~ 2.17% for OSLDs. Especially, the difference between planned dose and the delivery dose was increased in the perineum, a skin of intense flexure region, and the OSLDs as a result of close spacing of measuring a variate showed a steady dose verification than the diode detecters. Therefore, on behalf of the ionization chamber and diode detecters, OSLDs could be applied clinically in the verification of radiation dose error and in vivo dosimety. The research on the dose verification of the rectal cancer in the around perineal, a surface of intense flexure region, suggest continue to be.

MU Fluence Reconstruction based-on Delivered Leaf Position: for IMRT Quality Assurance (세기조절방사선치료의 정도관리를 위한 모니터유닛 공간분포 재구성의 효용성 평가)

  • Park, So-Yeon;Park, Yang-Kyun;Park, Jong-Min;Choi, Chang-Heon;Ye, Sung-Joon
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.1
    • /
    • pp.28-34
    • /
    • 2011
  • The measurement-based verification for intensity modulated radiation therapy (IMRT) is a time-and labor-consuming procedure. Instead, this study aims to develop a MU fluence reconstruction method for IMRT QA. Total actual fluences from treatment planning system (TPS, Eclipse 8.6, Varian) were selected as a reference. Delivered leaf positions according to MU were extracted by the dynalog file generated after IMRT delivery. An in-house software was develop to reconstruct MU fluence from the acquired delivered leaf position data using MATLAB. We investigated five patient's plans delivered by both step-and-shoot IMRT and sliding window technologies. The total actual fluence was compared with the MU fluence reconstructed by using commercial software (Verisoft 3.1, PTW) and gamma analysis method (criteria: 3%/3 mm and 2%/1 mm). Gamma pass rates were $97.8{\pm}1.33$% and the reconstructed fluence was shown good agreement with RTP-based actual fluence. The fluence from step and shoot IMRT was shown slightly higher agreement with the actual fluence than that from sliding window IMRT. If moving from IMRT QA measurements toward independent computer calculations, the developed method can be used for IMRT QA. A point dose calculation method from reconstructed fluences is under development for the routine IMRT QA purpose.

Sapflow Change and Growth Response of Poplar Species under Swine Wastewater Irrigation (양돈폐수처리시 포플러의 수액이동과 생장반응)

  • Lee, Eu Ddeum;Woo, Su Young;Yeo, Jin Kie;Koo, Yeong Bon;Chun, Seung-Hoon
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.6
    • /
    • pp.740-747
    • /
    • 2009
  • We examined sapflow of two Populus species such as Populus alba ${\times}$ Populus glandulosa and Populus euramericana, grown under Swine wastewater treatment. Sapflow of Populus euramericana was 1.8 times higher than that of Populus alba ${\times}$ Populus glandulosa for 14 months. Sapflow of Populus euramericana and Populus alba${\times}$Populus glandulosa was 4,628L and 2,538L during this period, respectively. Positive relationship between sapflow density and solar radiation and temperature had been shown. Mean temperature, relative humidity and sapflow was strongly associated. There was a decreasing sapflow tendency of the two poplar species during the late October when the mean temperature was decreased. In addition, the data showed high relationship between sapflow and photosynthesis. Two poplar species showed dramatic decrease of sapflow since October.

Epidemiology, Incidence and Mortality of Bladder Cancer and their Relationship with the Development Index in the World

  • Mahdavifar, Neda;Ghoncheh, Mahshid;Pakzad, Reza;Momenimovahed, Zohre;Salehiniya, Hamid
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.381-386
    • /
    • 2016
  • Background: Bladder cancer is an international public health problem. It is the ninth most common cancer and the fourteenth leading cause of death due to cancer worldwide. Given aging populations, the incidence of this cancer is rising. Information on the incidence and mortality of the disease, and their relationship with level of economic development is essential for better planning. The aim of the study was to investigate bladder cancer incidence and mortality rates, and their relationship with the the Human Development Index (HDI) in the world. Materials and Methods: Data were obtained from incidence and mortality rates presented by GLOBOCAN in 2012. Data on HDI and its components were extracted from the global bank site. The number and standardized incidence and mortality rates were reported by regions and the distribution of the disease were drawn in the world. For data analysis, the relationship between incidence and death rates, and HDI and its components was measured using correlation coefficients and SPSS software. The level of significance was set at 0.05. Results: In 2012, 429,793 bladder cancer cases and 165,084 bladder death cases occurred in the world. Five countries that had the highest age-standardized incidence were Belgium 17.5 per 100,000, Lebanon 16.6/100,000, Malta 15.8/100,000, Turkey 15.2/100,000, and Denmark 14.4/100,000. Five countries that had the highest age-standardized death rates were Turkey 6.6 per 100,000, Egypt 6.5/100,000, Iraq 6.3/100,000, Lebanon 6.3/100,000, and Mali 5.2/100,000. There was a positive linear relationship between the standardized incidence rate and HDI (r=0.653, P<0.001), so that there was a positive correlation between the standardized incidence rate with life expectancy at birth, average years of schooling, and the level of income per person of population. A positive linear relationship was also noted between the standardized mortality rate and HDI (r=0.308, P<0.001). There was a positive correlation between the standardized mortality rate with life expectancy at birth, average years of schooling, and the level of income per person of population. Conclusions: The incidence of bladder cancer in developed countries and parts of Africa was higher, while the highest mortality rate was observed in the countries of North Africa and the Middle East. The program for better treatment in developing countries to reduce mortality from the cancer and more detaiuled studies on the etiology of are essential.

Epidemiology of Breast Cancer among Females in Basrah

  • Habib, Omran S;Hameed, Lamis A;Ajeel, Narjis A;Al-Hawaz, Mazin H;Al-Faddagh, Zaki A;Nasr, Ghalib N;Al-Sodani, Ali H;Khalaf, Asaad A;Hasson, Hasson M;Abdul-Samad, Aida A
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.sup3
    • /
    • pp.191-195
    • /
    • 2016
  • Breast cancer is the most frequent cancer in females. Its incidence is higher in developed countries than in developing ones partly due to variation in risk exposure and partly due to better detection methods. Scattered evidence in Basrah, Iraq, suggests that breast cancer has been increasing at a significant pace in recent years. This study aimed to measure the current level of risk of breast cancer among females in Basrah and to describe the time trend over almost a decade of years. Data on breast cancer cases from all sources of cancer registration in Basrah governorate were compiled for the years 2005-2012. The data for each year were first checked separately for duplicate reporting of cases among various sources. Then the eight files were pooled together and checked again for any duplicate cases among years of registration. The final set of data contained 2,284 cases of breast cancer (2,213 female cases and 71 male cases). All patients were inhabitants of Basrah governorate at the time of diagnosis. Figures on the Basrah population were obtained from various sources including the Ministry of Health, Ministry of Planning and Developmental Collaboration and local household surveys. It was possible to have total population estimates for each year and by age and sex. The data were imported into SPSS (version 17) software. Age specific and year specific incidence rates were calculated. The age standardized incidence rate was also calculated using world population as the standard population to be 34.9 per 100,000 females. Age-wise, no case was reported among children aged less than 15 years and the incidence increased with advancing age reaching a peak of 123.8/100,000 females at the age range of 50-54 years. The time trend of the crude incidence rate showed only modest increased risk with passage of years and no age shift could be documented in this study. Breast cancer in females in Basrah is a significant health problem. The current incidence rate (crude, 23.7/100,000, age-standardized, 34.9/100,000) is high and justifies intensive efforts to improve early detection of cases, provide better treatment amenities and introduce long term preventive measures. Using the age standardized incidence rate as reported in this paper, it is possible to put the risk in Basrah within a regional and international context.

The Use of Polymer Gel for the Visualization of 3-D Dose Distribution in Brachytherapy Using Magnetic Resonance Imaging (방사선 근접치료에 있어서 핵자기공명영상을 이용한 3차원 방사선 선량분포도의 가시화를 위한 polymer 젤의 이용)

  • 강해진;조삼주;정은기;강승희;오영택;전미선;권수일
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.207-215
    • /
    • 1998
  • There have been many radiation measurement methods so far among which film dosimetry, TLD, and ion chamber are the most frequently used methods. But this study describes a new radiation measurement method which uses polymer gel and magnetic resonance imaging(MRI). The objective of this study is to fabricate a polymer gel sensitive to radiation and to generate a dose to MRI contrast relationship, and to apply this results to the radiation measurement for the brachytherapy. To do this, 12 cm diameter cylindrical gel phantom was made, and the phantom was irradiated using the 30 mm diameter circular collimator which was used for radiosurgery. And this irradiated phantom was scanned with MRI. To find out the relationship between the radiation dose and the transversal relaxation time, an image processing software(IDL) was used. From this study it is found out that the radiation dose showed linear relationship to the transversal relaxation time of the gel up to 17 Gy($R^2$=0.993) and they had a different relationship above 17 Gy. The dose distributions were calculated using these results for the Ir-192 sources, one for the HDR afterloading system and the other for a 2 mCi seed source. And these calculated dose distributions were compared to the ones from the treatment planning computers. From this study the dose to the irradiated gel's transversal relaxation time relationship was examined, and this result was tried for the measurement of the brachytherapy.

  • PDF

An Empirical Approach to Dosimetric Effect of Carbon Fiber Couch for Flattening Filter Free Beam of Elekta LINAC

  • Ahn, Sohyun;Park, Kwangwoo;Kim, Jinsung;Lee, Ho;Yoon, Jeongmin;Lee, Eungman;Park, Sohyun;Park, Jeongeun;Kim, Juhye;Keum, Ki Chang
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.220-223
    • /
    • 2016
  • Generally, it is recommended that the dosimetric effect of carbon fiber couch should be considered especially for an intensity-modulated therapy with a large portion of monitor units from posterior angles. Even a flattening filter free (FFF) beam has been used for stereotactic body radiation therapy (SBRT), the effect of carbon fiber couch for FFF beam is not well known. This work is an effort to evaluate the dosimetric effect of carbon fiber couch for flattened and FFF beam of Elekta linac empirically. The absorbed doses were measured with Farmer type chamber and water-equivalent phantoms with and without couch. And differences of the absorbed doses between with and without couch defined as "couch effect". By comparing calculated dose in treatment planning system (TPS) with measured dose, the optimal density of couch was evaluated. Finally, differences on patient's skin dose and target dose by couch were evaluated in TPS. As a result, the couch effect for 6 and 10 MV flattened beam were -2.71% and -2.32%, respectively. These values were agreed with provided data by vendor within 0.5%. The couch effect for 6 and 10 MV FFF beam were -3.75% and -2.80%, respectively. The patient's skin dose was increased as 18.6% and target dose was decreased as 0.87%, respectively. It was realized that the couch effect of FFF beam was more severe than that of flattened beam. Patient's skin dose and target dose were changed by the couch effect.

Patient-Specific Quality Assurance in a Multileaf Collimator-Based CyberKnife System Using the Planar Ion Chamber Array

  • Yoon, Jeongmin;Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.59-65
    • /
    • 2018
  • This paper describes the clinical use of the dose verification of multileaf collimator (MLC)-based CyberKnife plans by combining the Octavius 1000SRS detector and water-equivalent RW3 slab phantom. The slab phantom consists of 14 plates, each with a thickness of 10 mm. One plate was modified to support tracking by inserting 14 custom-made fiducials on surface holes positioned at the outer region of $10{\times}10cm^2$. The fiducial-inserted plate was placed on the 1000SRS detector and three plates were additionally stacked up to build the reference depth. Below the detector, 10 plates were placed to avoid longer delivery times caused by proximity detection program alerts. The cross-calibration factor prior to phantom delivery was obtained by performing with 200 monitor units (MU) on the field size of $95{\times}92.5mm^2$. After irradiation, the measured dose distribution of the coronal plane was compared with the dose distribution calculated by the MultiPlan treatment planning system. The results were assessed by comparing the absolute dose at the center point of 1000SRS and the 3-D Gamma (${\gamma}$) index using 220 patient-specific quality assurance (QA). The discrepancy between measured and calculated doses at the center point of 1000SRS detector ranged from -3.9% to 8.2%. In the dosimetric comparison using 3-D ${\gamma}$-function (3%/3 mm criteria), the mean passing rates with ${\gamma}$-parameter ${\leq}1$ were $97.4%{\pm}2.4%$. The combination of the 1000SRS detector and RW3 slab phantom can be utilized for dosimetry validation of patient-specific QA in the CyberKnife MLC system, which made it possible to measure absolute dose distributions regardless of tracking mode.

Planning Aspects of Volumetric Modulated Arc Therapy and Intensity Modulated Radio therapy in Carcinoma Left Breast - A Comparative Study

  • Ekambaram, Varadharajan;Velayudham, Ramasubramanian;Swaminathan, Shiyama;Loganathan, Padmanabhan;Swaminathan, Vijaya
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.4
    • /
    • pp.1633-1636
    • /
    • 2015
  • Background: The advantages of Rapid Arc plans versus Intensity modulated radiotherapy plans for Carcinoma left breast were analyzed. Materials and Methods: In this study 20 Post mastectomy carcinoma left breast patients were analyzed. Both Intensity modulated Radiotherapy and Rapid Arc plans were generated for these patients. IMRT plans with 7 beams in an arc fashion and VMAT plans with two semi arcs were made to achieve 95% dose coverage to 100% volume. The plans were evaluated using Dose volume Histograms. Results: The mean Conformity and Homogeneity index in VMAT is found to be 1.05 and 0.065 respectively whereas in IMRT it was 1.07 and 0.069. The 20% volume of Heart received a mean dose of 960cGy in VMAT and 1300cGy in IMRT. The mean dose was 1236cGy in VMAT and 1870cGy in IMRT. The ipsilateral Lung received 3395cGy to 5% volume and 1840cGy to 20% volume on an average and the mean dose was 1205cGy in VMAT, while the same were found to be 3525cGy, 2012cGy and 1435cGy respectively in IMRT. The Contralateral Lung received a mean dose of 505cGy in VMAT and 553cGy in IMRT. The mean Monitor units in VMAT were 512MU and 1170MU in IMRT. The NTID in VMAT is $108.8{\times}10^5Gycm^3$ and $110.1{\times}10^5Gycm^3$ in IMRT. Conclusions: The target coverage, homogeneity and Conformity index were better in VMAT plans. The Ipsilateral Lung and heart dose were very less in VMAT plans. The Contralateral Lung dose and the Normal Tissue Integral Dose were also lesser in VMAT plans however the difference is not very appreciable. The MU in VMAT plans is almost 50% that of the IMRT plans which results in the reduction of treatment time. On the whole VMAT proves to be a better modality for treating Ca. Left Breast Patients.

Facial Analysis of Patients with Skeletal Malocclusion Using a Facial 'Phi' Mask (Facial 'Phi' Mask를 사용한 골격성 부정교합 환자의 안모 분석)

  • Kim, Hong-Seok;Heo, Young-Min;Hong, Jong-Rak;Kim, Chang-Soo;Paeng, Jun-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.26-33
    • /
    • 2012
  • Purpose: The golden ratio has been used for a long time to objectify and quantify 'beauty'. Dr. Marqurardt claims that the golden ratio can be applied in the maxillofacial field as well. The purpose of this study was to evaluate the diagnostic significance of using a facial 'phi' mask for analyzing Korean faces with characteristics of Class I, II, and III malocclusion. Methods: We studied twenty five Korean celebrities' frontal facial photos (10 males, 15 females) and 90 malocclusion patients' frontal facial photos (30 patients in each malocclusion classification: Class I, Class II, and Class III). Patients who received orthodontic treatment at Samsung Medical Center were selected for this study. After superimposition of the selected facial photo and facial 'phi' mask using Adobe Photoshop CS3, the ratio of the entire facial area, mid facial area, lower facial area and horizontal and vertical lengths were measured. Results: The facial ratio in photos of Korean faces showed larger vertical and horizontal ratios than the facial 'phi' mask with golden ratio, regardless of skeletal malocclusion (entire face: 115%, lower face: 125% larger than the mask). The results of the frontal photos of Class I, II, and III malocclusion patients using facial 'phi' mask showed that the vertical length and frontal face area was more significantly influenced by the area of the lower face than the midface. This means that the lower face has larger proportions in the facial areas. Conclusion: The ratio of facial 'phi' mask is matched with the ideal facial appearance that the contemporary Korean general public is seeking. Thus, the facial 'phi' mask may be a convenient tool for esthetic analysis of Korean faces. Reducing the area of the lower face is esthetically more desirable for almost all Korean people when planning orthognathic surgery.