• Title/Summary/Keyword: treatment device

Search Result 1,531, Processing Time 0.044 seconds

A Study on Human Rights in North Korea in terms of Haewon-sangsaeng (해원상생 관점에서의 북한인권문제 고찰)

  • Kim Young-jin
    • Journal of the Daesoon Academy of Sciences
    • /
    • v.43
    • /
    • pp.67-102
    • /
    • 2022
  • The purpose of this study is to analyze the human rights found in the North Korean Constitution and their core problem by focusing on elements of human rights suggested by Daesoon Jinrihoe's doctrine of Haewon-sangsaeng (解冤相生 the Resolution of Grievances for Mutual Beneficence). Haewon-sangsaeng is seemingly the only natural law that could resolve human resentment lingering from the Mutual Contention of the Former World while leading humans work for the betterment of one another. Haewon-sangsaeng, as a natural law, includes the right to life, the right to autonomous decision-making, and duty to act according to human dignity (physical freedom, the freedom of conscience, freedom of religion, freedom of speech, freedom of press, etc.), the right to equal treatment in one's social environment, and the right to ensure the highest level of health through treatment. The North Korean Constitution does not have a character as an institutional device to guarantee natural human rights, the fundamental principle of the Constitution, and stipulates the right of revolutionary warriors to defend dictators and dictatorships. The right to life is specified so that an individual's life belongs to the life of the group according to their socio-political theory of life. Rights to freedom are stipulated to prioritize group interests over individual interests in accordance with the principle of collectivism. The right to equality and the right to health justify discrimination through class discrimination. The right to life provided to North Koreans is not guaranteed due to the death penalty system found within the North Korean Criminal Code and the Criminal Code Supplementary Provisions. The North Korean regime deprives North Koreans of their right to die with dignity through public executions. The North Korean regime places due process under the direction of the Korea Worker's Party, recognizes religion as superstition or opium, and the Korea Worker's Party acknowledge the freedoms of bodily autonomy, religion, media, or press. North Koreans are classified according to their status, and their rights to equality are not guaranteed because they are forced to live a pre-modern lifestyle according to the patriarchal order. In addition, health rights are not guaranteed due biased availability selection and accessibility in the medical field as well as the frequent shortages of free treatments.

A Retrospective Study of the Radiotherapy Care Patterns for Patients with Laryngeal Cancer and Comparison of Different Korean Hospitals Treated from 1998 through 1999 (한국인 후두암 환자의 방사선치료 과정 및 내용에 관한 분석 (1998~1999년도))

  • Chung, Woong-Ki;Kim, Il-Han;Yoon, Mee-Sun;Ahn, Sung-Ja;Nam, Taek-Keun;Song, Ju-Young;Chung, Jae-Uk;Nah, Byung-Sik;Lee, Joon-Kyoo;Wu, Hong-Gyun;Lee, Chang-Geol;Lee, Sang-Wook;Park, Won;Ahn, Yong-Chan;Kang, Ki-Moon;Kim, Jung-Soo;Oh, Yoon-Kyeong;Cho, Moon-June;Park, Woo-Yoon;Kim, Jin-Hee;Choi, Doo-Ho;Yun, Hyong-Geun;Kim, Woo-Cheol;Yang, Dae-Sik;Sohn, Seung-Chang;Suh, Hyun-Suk;Ahn, Ki-Jung;Chun, Mi-Son;Lee, Kyu-Chan;Choi, Young-Min;Jeung, Tae-Sik;Kang, Jin-Oh
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.201-209
    • /
    • 2009
  • Purpose: To investigate the care patterns for radiation therapy and to determine inter-hospital differences for patients with laryngeal carcinoma in Korea. Materials and Methods: A total of 237 cases of laryngeal carcinoma (glottis, 144; supraglottis, 93) assembled from 23 hospitals, who underwent irradiation in the year of 1998 and 1999, were retrospectively analyzed to investigate inter-hospital differences with respect to radiotherapy treatment. We grouped the 23 hospitals based on the number of new patients annually irradiated in 1998; and designated them as group A (${\geq}$900 patients), group B (${\geq}$400 patients and <900 patients), and group C (<400 patients). Results: The median age of the 237 patients was 62 years (range, 25 to 88 years), of which 216 were male and 21 were female. The clinical stages were distributed as follows: for glottis cancer, I; 61.8%, II; 21.5%, III; 4.2%, IVa; 11.1%, IVb; 1.4%, and in supraglottic cancer, I; 4.3%, II; 19.4%, III; 28.0%, IVa; 43.0%, IVb; 5.4%, respectively. Some differences were observed among the 3 groups with respect to the dose calculation method, radiation energy, field arrangement, and use of an immobilization device. No significant difference among 3 hospital groups was observed with respect to treatment modality, irradiation volume, and median total dose delivered to the primary site. Conclusion: This study revealed that radiotherapy process and patterns of care are relatively uniform in laryngeal cancer patients in Korean hospitals, and we hope this nationwide data can be used as a basis for the standardization of radiotherapy for the treatment of laryngeal cancer.

Evaluating efficiency of application the skin flash for left breast IMRT. (왼쪽 유방암 세기변조방사선 치료시 Skin Flash 적용에 대한 유용성 평가)

  • Lim, Kyoung Dal;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.49-63
    • /
    • 2018
  • Purpose : The purpose of this study is investigating the changes of treatment plan and comparing skin dose with or without the skin flash. To investigate optimal applications of the skin flash, the changes of skin dose of each plans by various thicknesses of skin flash were measured and analyzed also. Methods and Material : Anthropomorphic phantom was scanned by CT for this study. The 2 fields hybrid IMRT and the 6 fields static IMRT were generated from the Eclipse (ver. 13.7.16, Varian, USA) RTP system. Additional plans were generated from each IMRT plans by changing skin flash thickness to 0.5 cm, 1.0 cm, 1.5 cm, 2.0 cm and 2.5 cm. MU and maximum doses were measured also. The treatment equipment was 6MV of VitalBeam (Varian Medical System, USA). Measuring device was a metal oxide semiconductor field-effect transistor(MOSFET). Measuring points of skin doses are upper (1), middle (2) and lower (3) positions from center of the left breast of the phantom. Other points of skin doses, artificially moved to medial and lateral sides by 0.5 cm, were also measured. Results : The reference value of 2F-hIMRT was 206.7 cGy at 1, 186.7 cGy at 2, and 222 cGy at 3, and reference values of 6F-sIMRT were measured at 192 cGy at 1, 213 cGy at 2, and 215 cGy at 3. In comparison with these reference values, the first measurement point in 2F-hIMRT was 261.3 cGy with a skin flash 2.0 cm and 2.5 cm, and the highest dose difference was 26.1 %diff. and 5.6 %diff, respectively. The third measurement point was 245.3 cGy and 10.5 %diff at the skin flash 2.5 cm. In the 6F-sIMRT, the highest dose difference was observed at 216.3 cGy and 12.7 %diff. when applying the skin flash 2.0 cm for the first measurement point and the dose difference was the largest at the application point of 2.0 cm, not the skin flash 2.5 cm for each measurement point. In cases of medial 0.5 cm shift points of 2F-hIMRT and 6F-sIMRT without skin flash, the measured value was -75.2 %diff. and -70.1 %diff. at 2F, At -14.8, -12.5, and -21.0 %diff. at the 1st, 2nd and 3rd measurement points, respectively. Generally, both treatment plans showed an increase in total MU, maximum dose and %diff as skin flash thickness increased, except for some results. The difference of skin dose using 0.5 cm thickness of skin flash was lowest lesser than 20 % in every conditions. Conclusion : Minimizing the thickness of skin flash by 0.5 cm is considered most ideal because it makes it possible to keep down MUs and lowering maximum doses. In addition, It was found that MUs, maximum doses and differences of skin doses did not increase infinitely as skin flash thickness increase by. If the error margin caused by PTV or other factors is lesser than 1.0 cm, It is considered that there will be many advantages in with the skin flash technique comparing without it.

  • PDF

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF

Clinical Application of Dose Reconstruction Based on Full-Scope Monte Carlo Calculations: Composite Dose Reconstruction on a Deformed Phantom (몬테칼로 계산을 통한 흡수선량 재구성의 임상적 응용: 변형된 팬텀에서의 총제적 선량재구성)

  • Yeo, Inhwan;Xu, Qianyi;Chen, Yan;Jung, Jae Won;Kim, Jong Oh
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.139-142
    • /
    • 2014
  • The purpose of this study was to develop a system of clinical application of reconstructed dose that includes dose reconstruction, reconstructed dose registration between fractions of treatment, and dose-volume-histogram generation and to demonstrate the system on a deformable prostate phantom. To achieve this purpose, a deformable prostate phantom was embedded into a 20 cm-deep and 40 cm-wide water phantom. The phantom was CT scanned and the anatomical models of prostate, seminal vesicles, and rectum were contoured. A coplanar 4-field intensity modulated radiation therapy (IMRT) plan was used for this study. Organ deformation was simulated by inserting a "transrectal" balloon containing 20 ml of water. A new CT scan was obtained and the deformed structures were contoured. Dose responses in phantoms and electronic portal imaging device (EPID) were calculated by using the XVMC Monte Carlo code. The IMRT plan was delivered to the two phantoms and integrated EPID images were respectively acquired. Dose reconstruction was performed on these images using the calculated responses. The deformed phantom was registered to the original phantom using an in-house developed software based on the Demons algorithm. The transfer matrix for each voxel was obtained and used to correlate the two sets of the reconstructed dose to generate a cumulative reconstructed dose on the original phantom. Forwardly calculated planning dose in the original phantom was compared to the cumulative reconstructed dose from EPID in the original phantom. The prescribed 200 cGy isodose lines showed little difference with respect to the "prostate" and "seminal vesicles", but appreciable difference (3%) was observed at the dose level greater than 210 cGy. In the rectum, the reconstructed dose showed lower volume coverage by a few percent than the plan dose in the dose range of 150 to 200 cGy. Through this study, the system of clinical application of reconstructed dose was successfully developed and demonstrated. The organ deformation simulated in this study resulted in small but observable dose changes in the target and critical structure.

Radiofrequency thermal Shrinkage for Elongated Anterior Cruciate Ligament after Anterior Cruciate Ligament Reconstruction (전방십자인대 재건술 이후 이완된 전방십자인대에 시행한 고주파 에너지 열 수축)

  • Kim, Yeung-Jin;Chun, Churl-Hong;Kim, Tae-Kyun;Yang, Hwan-Deok;Kim, Hyoung-Joon;Kim, Young-Jin
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.1
    • /
    • pp.27-32
    • /
    • 2008
  • Purpose: To evaluate the clinical results of the patients who underwent radiofrequency thermal shrinkage (RFTS) for treatment of anterior cruciate ligament (ACL) laxity after ACL reconstruction. Material and Methods: From October 1999 to March 2006, we performed 133 cases of ACL reconstruction. Among them we experienced 16 patients who had the laxity of reconstructed ACL in second look arthroscopy. Mean follow-up was 20.4 months. Mean age was 33.5 years. 12 cases were male and 4 cases were female. The elongated ACL were treated by bipolar radiofrequency energy with an output of grade II. Subjective and objective parameters were utilized in analyses, such as: the mean range of motion, Lysholm knee score, Tegner activity score, Lachman test, IKDC score. Wilcoxon signed-rank test was used to perform the data analysis. P<0.05 was considered to be statistically significant. Results: Postoperative mean Lysholm knee score (preop: $82.2{\pm}5.2(77{\sim}85))$ (P=0.04), postop: $85.2{\pm}4.8$(82-90)) and anterior displacement by the Telos stress test (preop: $5.4{\pm}4.6(3{\sim}10)mm$, postop: $2.1{\pm}1.9(0{\sim}4)mm)$ (P=0.02), Lachman's test, and IKDC scores (P=0.04) demonstrated significant differences statistically compared to the preoperative. There were no statistical differences in mean range of motion, Tegner activity scale. Conclusions: Arthroscopic shrinkage for the ACL laxity after ACL reconstruction with radiofrequency device showed good clinical results and was applicable operative technique.

  • PDF

A Study of Guide System for Cerebrovascular Intervention (뇌혈관 중재시술 지원 가이드 시스템에 관한 연구)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Yoon, Kwon-Ha;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.101-107
    • /
    • 2016
  • Due to the recent advancement in digital imaging technology, development of intervention equipment has become generalize. Video arbitration procedure is a process to insert a tiny catheter and a guide wire in the body, so in order to enhance the effectiveness and safety of this treatment, the high-quality of x-ray of image should be used. However, the increasing of radiation has become the problem. Therefore, the studies to improve the performance of x-ray detectors are being actively processed. Moreover, this intervention is based on the reference of the angiographic imaging and 3D medical image processing. In this paper, we propose a guidance system to support this intervention. Through this intervention, it can solve the problem of the existing 2D medical images based vessel that has a formation of cerebrovascular disease, and guide the real-time tracking and optimal route to the target lesion by intervention catheter and guide wire tool. As a result, the system was completely composed for medical image acquisition unit and image processing unit as well as a display device. The experimental environment, guide services which are provided by the proposed system Brain Phantom (complete intracranial model with aneurysms, ref H+N-S-A-010) was taken with x-ray and testing. To generate a reference image based on the Laplacian algorithm for the image processing which derived from the cerebral blood vessel model was applied to DICOM by Volume ray casting technique. $A^*$ algorithm was used to provide the catheter with a guide wire tracking path. Finally, the result does show the location of the catheter and guide wire providing in the proposed system especially, it is expected to provide a useful guide for future intervention service.

Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy (토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교)

  • Lee, Byungkoo;Kang, Suman
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.145-149
    • /
    • 2013
  • Helical Tomotherapy is an innovative means of delivering intensity modulated radiation therapy (IMRT) using a device that merges features of a linear accelerator and helical computed tomography (CT) scanner. Hereat, during helical tomotherapy process, megavoltage computed tomography (MVCT) image are usually used for guiding the precise set-up of patient before/after treatment delivery. But which would certainly increase the total dose for patients, this study was to investigate the imaging dose of MVCT using the cylindrical "Cheese" phantom on a tomotherapy machine. A set of cylindrical "Cheese" phantom was adopted for scanning with respectively pitch value (1, 2, 3 mm) with same number slice (10 slice), same length (approximately 9 cm) and phantom set-ups on the couch of tomotherapy system. The average MVCT imaging dose were measured using A1SL ion chamber inserted in the phantom with preset geometry. The MVCT scanning average dose for the cylindrical "Cheese" phantom was 2.24 cGy, 1.02 cGy, 0.81 cGy during respectively pitch value (pitch 1, 2, 3 mm) with same number slice (10 slice), and same length's average dose was 2.47 cGy, 1.28 cGy, 0.88 cGy respectively (pitch 1, 2, 3 mm). Two major parameters, the assigned pitch numbers and scanning length, where the most important impacts to the dose variation. The MVCT dose was inversely proportional to the CT pitch value. The results may provide a reliable guidance for proper planning design of the scanning region, which is valuable to help minimize the extra dose to patient. Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines.

Histological Observation of Bone Reaction with Relation to Surface Treatment of Titanium (생체합금 Titanium의 표면처리에 따른 골반응의 변화에 대한 조직학적 관찰)

  • Ahn, Myun-Whan;Choi, Yong-Sug;Ahn, Jong-Chul;Seo, Jae-Sung;Lee, Dong-Chul;Jang, Jae-Hyuk
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.1
    • /
    • pp.116-133
    • /
    • 1996
  • The biocompatibility of the titanium has been estabilished through various experimental studies such as cell culture toxicity test, pyrogen test, mutagen test and others. In order to confirm biocompatibility after fabrication of titanium and to clarify the difference between the bone reaction after insertion of the lathed titanium rods and the bone reaction after insertion of the finished and polished rods, both rods were implanted into the proximal femur of a rabbit. Histologic reactions in the bone were observed according to the ASTM standards at the intervals of 6 weeks, 12 weeks and 26 weeks after implantation. The result were as follows : In 6 weeks after implantation of lathed titanium rods, inflammatory reactions, such as minimal degree infiltration of polymorphonuclear leukocytes and lymphocytes were observed in all cases. This was thought to he caused by surgical trauma. However, inflammatory cell infiltration was not seen after implantation of polished and finished rods in all cases. The cellular infiltration and the histologic reaction of the hone after implantation of lathed group were significantly more pronounced than those after implantation of the finished group. In 12 weeks after implantation of lathed rods, two of four cases revealed a minimal degree of cellular infiltration. No inflammatory cell infiltration was demonstrated after implantation of the finished group. The cellular infiltration and histologic reaction seemed to be more pronounced in the lathed group, but they were not significant statistically. At 26 weeks after implantation of the lathed and finished group, there was no cellular infiltration in both groups. New bone formation was observed up 26 weeks, and no difference between lathed titanium rods and finished titanium rods were apparent. Mild bone necrosis was observed in 1 case out of 11 cases in which lathed titanium rods were implanted. Bone necrosis was not observed in the finished titanium rod group. Fibrosis was observed in both groups, but differences were not significant between the experimental groups. In the lathed titanium rods group and the shorter interval group, inflammatory cell infiltration was significantly higher. Finished titanium rods and longer interval groups had markedly decreased tendences in histologic reaction ratings. As a conclusion, although certificated titanium might be safe to use, difference of biocompatibility were observed depending on the method of surface finish. By identifying biocompatibility as a long-term standardized animal study, we can develop progressed internal fixation device that is safe for human beings.

  • PDF

Contralateral Breast Doses Depending on Treatment Set-up Positions for Left-sided Breast Tangential Irradiation (좌측 유방암 환자의 방사선 치료 시 환자자세에 따른 반대편 유방의 산란선량 측정)

  • Joo, Chan Seong;Park, Su Yeon;Kim, JongSik;Choi, Byeong Gi;Chung, Yoonsun;Park, Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.175-181
    • /
    • 2015
  • Purpose : To evaluate Contralateral Breast Doses with Supine and Prone Positions for tangential Irradiation techniques for left-sided breast Cancer Materials and Methods : We performed measurements for contralateral doses using Human Phantom at each other three plans (conventional technique, Field-in-Field, IMRT, with prescription of 50 Gy/25fx). For the measurement of contralateral doses we used Glass dosimeters on the 4 points of Human Phantom surface (0 mm, 10 mm, 30 mm, 50 mm). For the position check at every measurements, we had taken portal images using EPID and denoted the incident points on the human phantom for checking the constancy of incident points. Results : The contralateral doses in supine position showed a little higher doses than those in prone position. In the planning study, contralateral doses in the prone position increased mean doses of 1.2% to 1.8% at each positions while those in the supine positions showed mean dose decreases of 0.8% to 0.9%. The measurements using glass dosimeters resulted in dose increases (mean: 2.7%, maximum: 4% of the prescribed dose) in the prone position. In addition, the delivery techniques of Field-in-field and IMRT showed mean doses of 3% higher than conventional technique. Conclusion : We evaluated contralateral breast doses depending on different positions of supine and prone for tangential irradiations. For the phantom simulation of set-up variation effects on contralateral dose evaluation, although we used humanoid phantom for planning and measurements comparisons, it would be more or less worse set-up constancy in a real patient. Therefore, more careful selection of determination of patient set-up for the breast tangential irradiation, especially in the left-sided breast, should be considered for unwanted dose increases to left lung and heart. In conclusion, intensive patient monitoring and improved patient set-up verification efforts should be necessary for the application of prone position for tangential irradiation of left-sided breast cancer.

  • PDF