• Title/Summary/Keyword: transmission distribution

Search Result 1,550, Processing Time 0.031 seconds

Evaluation of Modulus of Elasticity of Wood Exposed to Accelerated Weathering Test by Measuring Ultrasonic Transmission Time (촉진 열화 목재의 초음파 전달 시간 측정을 통한 탄성 계수의 평가)

  • Park, Chun-Young;Kim, Gwang-Chul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.3
    • /
    • pp.275-281
    • /
    • 2014
  • In this study, accelerated weathering test was performed with wood, a major material for wooden cultural building. In order to evaluate the deterioration of wood, ultrasonic transmission times were measured to evaluate dynamic modulus of elasticity (MOE), which was verified by determining static MOE using three-point bending test. Ultrasonic transmission time was decreased with an increase in the weathering time levels (0, 500, 1000 hours) while it increased in 1500 and 2000 hours. Distribution of dynamic and static MOE was similar to that of the ultrasonic transmission time measurements. The results mean that the measurement of ultrasonic transmission time was very effective to evaluate MOE of wooden cultural buildings for their preservation and management. This method could be utilized to assess wooden cultural buildings as a way of preserving them in a scientific manner.

An Experimental Study on Multiple ICP & Helicon Source for Oxidation in Semiconductor Process

  • Lee, Jin-Won;Na, Byoung-Keun;An, Sang-Hyuk;Chang, Hong-Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.271-271
    • /
    • 2012
  • Many studies have been investigated on high density plasma source (Electron Cyclotron Resonance, Inductively Coupled Plasma, Helicon plasma) for large area source after It is announced that productivity of plasma process depends on plasma density. In this presentation, we will propose the new concept of the multiple source, which consists of a parallel connection of ICP sources and helicon plasma sources. For plasma uniformity, equivalent power (especially, equivalent current in ICP & Helicon) should distribute on each source. We design power feeding line as coaxial transmission line with same length of ground line in each source for equivalent power distribution. And we confirm the equivalent power distribution with simulation and experimental result. Based on basic study, we develop the plasma source for oxidation in semiconductor process. we will discuss the relationship between the processing parameters (With or WithOut magnet, operating pressure, input power ). In ICP, plasma density uniformity is uniform. In ICP with magnet (or Helicon) plasma density is not uniform. As a result, new design (magnet arrangement and gas distributor and etc..) are needed for uniform plasma density in ICP with magnet and Helicon.

  • PDF

A Study on the Synthesis of Dielectric Constant Potential for Arbitrary Inverse Scattering Pattern Using an Iterative Sampling Method (반복 샘플링법을 사용한 임의 역산란 패턴을 위한 유전율 포텐셜 합성에 관한 연구)

  • 남준석;박의준
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.10
    • /
    • pp.150-158
    • /
    • 2003
  • In the beam pattern synthesis problem using line source, the relationship between source distribution function and beam pattern may be represented by Fourier transform pair. In this paper, a general method to synthesize the line source distribution for a desired lobe-like beam pattern is presented by developing the nonlinear inversion method based on an iterative sampling technique. This method can be applied to the synthesis of continuously distributed dielectric constants satisfying the desired inverse scattering coefficient patterns when illuminating by TE-polarized and TM-polarized plane waves to arbitrary dielectric material. Furthermore this method can also be applied to the synthesis of transmission line with arbitrary reflection coefficient patterns. Some bandstop spatial filter and dispersive transmission line filter are illustrated for generality.

Optimal Coordination of Intermittent Distributed Generation with Probabilistic Power Flow

  • Xing, Haijun;Cheng, Haozhong;Zhang, Yi
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2211-2220
    • /
    • 2015
  • This paper analyzes multiple active management (AM) techniques of active distribution network (ADN), and proposes an optimal coordination model of intermittent distributed generation (IDG) accommodation considering the timing characteristic of load and IDG. The objective of the model is to maximize the daily amount of IDG accommodation under the uncertainties of IDG and load. Various active management techniques such as IDG curtailment, on-load tap changer (OLTC) tap adjusting, voltage regulator (VR) tap adjusting, shunt capacitors compensation and so on are fully considered. Genetic algorithm and Primal-Dual Interior Point Method (PDIPM) is used for the model solving. Point estimate method is used to simulate the uncertainties. Different scenarios are selected for the IDG accommodation capability investigation under different active management schemes. Finally a modified IEEE 123 case is used to testify the proposed accommodation model, the results show that the active management can largely increase the IDG accommodation and penetration.

A Study on the Reliability and Life of the Ravigneaux Planetry Gear Train (라비니오 유성기어의 신뢰성 및 수명에 관한 연구)

  • Kim, T.H.;Kim, H.S.;Yang, S.M.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.10
    • /
    • pp.36-45
    • /
    • 1996
  • The precise estimation of the reliability and life of the Ravigneaux planetary gear train used in an automatic transmission is necessary in order to enable accurate material and geometric properties to reliability distrobution and the number of load cycles at failure. These are critical for the proba- bilistic design of complex planetary gear system as Ravigneaux type particularly during various gear ratios. The Ravigneaux planetary gear train has five gears, such as a forward and a reverse sun gear, a short and a long pinion, and an annulus gear. In this paper, the Ravigneaux gear system is analyzed to figure out the reliablity distribution. i.e. the probability of survival in the system without its overhaul. First, the reliablity method based on the Weibull distribution is used in conjuction with the Palmgren's model to predict both the individual reliabilities of its components and the nimber of load cycles when the system failed. Then using the presented method, the life of the Ravigneaux gear system can be determined. Alwo the different design parameters such as tooth face width, material property, and Weibull exponent are applied and reached to optimal ones. Thus, the precise evaluation of the reliability and life of the Ravigneaux planetary gear train used in an automatic transmission can be effectively carried out.

  • PDF

Security Constrained Economic Dispatch Using Primal Interior Point Method (Primal Interior Point법에 의한 선로 전력조류 제약을 고려한 경제급전)

  • Jeong, Rin-Hak;Jeong, Jae-Gil;Lee, Seung-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.10
    • /
    • pp.480-488
    • /
    • 2001
  • This paper presents a technique that can obtain an optimal solution for the Security-Constrained Economic Dispatch (SCED) problems using the Interior Point Method (IPM) while taking into account of the power flow constraints. The SCED equations are formulated by using only the real power flow equations from the optimal power flow. Then an algorithm is presented that can linearize the SCED equations based on the relationships among generation real power outputs, loads, and transmission losses to obtain the optimal solutions by applying the linear programming (LP) technique. The objective function of the proposed linearization algorithm are formulated based on the fuel cost functions of the power plants. The power balance equations utilize the Incremental Transmission Loss Factor (ITLF) corresponding to the incremental generation outputs and the line constraints equations are linearized based on the Generalized Generation Distribution Factor (GGDF). Finally, the application of the Primal Interior Point Method (PIPM) for solving the optimization problem based on the proposed linearized objective function is presented. The results are compared with the Simplex Method and the promising results ard obtained.

  • PDF

A Study on the Power System Application of High-Tc Superconducting Fault Current Limiter (고온초전도 한류기의 전력계통 적용에 관한 연구)

  • Bae, Hyeong-Thaek;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.115-116
    • /
    • 2006
  • Since the discovery of the high-temperature superconductors, many researches have been performed for the practical applications of superconductivity technologies in various fields. As results, significant progress has been achieved. Especially, Superconducting Fault Current Limiter (SFCL) offers an attractive means to limit fault current in power systems. The SFCLS, in contrast to current limiting reactors or high impedance transformers, are capable of limiting short circuit currents without adding considerable voltage drop and energy loss to power systems during normal operation. Under fault conditions, a resistance is automatically inserted into the power grid to limit the peak short-circuit current by transition from the superconducting state to the normal state, the quench. The advantages, like fail safe operation and quick recovery, make SFCL very attractive, especially for rapidly growing power systems with higher short-circuit capacities. In order to verify the effectiveness of the SFCL, in this paper, the analysis of fault current and voltage stability assessment in a sample distribution system and a transmission system are performed by the PSCAD/EMTDC based simulation method. Through the simulation, the advantage of SFCL application is shown, and the effective parameters of the SFCL are also recommended for both distribution and transmission systems. A resistive type component of SFCL is adopted in the analysis. The simulation results demonstrate not only the effectiveness of the proposed simulation scheme but also SFCL parameter assessment technique.

  • PDF

Safeguard system using distribution line and telecommunication network for controlling aimless behavior in senile elderly patients

  • Yamamoto, Hiromi;Wakamatsu, Hidetoshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.885-890
    • /
    • 1988
  • This is a successive study of the development and application of an electronic safeguard system for elderly men (senile dementia patients) who wander without purpose because of declined mental capability, while retaining their physical ability. The new safeguard system is designed with some additional functions on the basis of the previously developed system. Firstly, alarms are designed not to disturb other patients at night, so that informations about doors from which the patients go out may be transmitted to helpers individually by radio paging system. Secondly, the system hardware can be set up anywhere without laying particular signal transmission cables, provided that there exist AC power distribution lines for the utilization as a transmission line of signals to alarm indicators. Thirdly, it is possible to have a grasp of the whole states of the safeguard systems at the center of operation by monitoring the operational state of each system with a necessary data acquisition according to its instruction through telecommunication network. Thus, each safeguard system can be economically supplied to the special nursing homes and the helpers are ensured more released from physical and psychological burdens so that they can devote themselves to the care of senile elderly men, thereby improving their patients' comfort and human dignity.

  • PDF

Cross-Layer Resource Allocation with Multipath Routing in Wireless Multihop and Multichannel Systems

  • Shin, Bong-Jhin;Choe, Jin-Woo;Kang, Byoung-Ik;Hong, Dae-Hyoung;Park, Young-Suk
    • Journal of Communications and Networks
    • /
    • v.13 no.3
    • /
    • pp.221-231
    • /
    • 2011
  • A joint multipath routing algorithm and channel allocation and scheduling for wireless multihop and multichannel systems is discussed. In packet transmission, distribution of packets to multiroutes makes it possible to reduce the transmission cost of the channels. Cross-layer cooperation of routing, channel allocation, and scheduling is an effective method of packet distribution. As a framework for the cooperation, we propose a multiroute distance vector routing (MDVR) scheme. In the MDVR scheme, the routing table is logically placed in between the routing and link layers, and the table plays the role of a service access point between these two layers. To evaluate the performance of MDVR, simulation is performed in a multichannel, multihop environment. The simulation results show that the MDVR framework can be efficiently implemented in the form of a distributed routing algorithm. It is also shown that in MDVR, the system-wise channel efficiency is almost 25% higher than that in a conventional single-route routing approach.

A Study on the Lightning Overvoltage Analysis and Lightning Surge Protection Methods in Underground Distribution System (지중배전계통의 뇌과전압 해석 및 뇌써지 보호방안에 관한 연구)

  • Kim, Sang-Kuk;Jung, Chae-Kyun;Lee, Jong-Beom;Ha, Dong-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.558-560
    • /
    • 2003
  • The effects of surge arresters for protection of transmission systems against direct lightning strokes have already been investigated using the digital simulation program EMTP. Distribution lines are spanned on a much large area as compared to transmission lines, and therefore, are more often susceptible to lightning strokes. This paper analyzes the overvoltages on underground cable system against direct lightning strokes to the overhead ground wire using the digital simulation. The effects of lightning protection methods, such as lowering the grounding resistance and installing the surge arrester, for preventing overvoltages on underground cable system caused by direct lightning strokes to the overhead ground wire is investigated. Several schemes have been proposed to protect underground cables. This paper summarizes the main results of a study aimed at analysis of lightning overvoltages in variety underground feeders protected by metal-oxide arresters. This study will provide insulation coordination methods for reasonable system design in 22.9kV underground cable system.

  • PDF