• Title/Summary/Keyword: transmission distribution

Search Result 1,550, Processing Time 0.027 seconds

Strain Transmission Ratio of a Distributed Optical Fiber Sensor with a Coating Layer (코팅된 분포형 광섬유 센서의 변형률 전달률)

  • Yoon, S.Y.;Kown, I.B.;Yu, H.S.;Kim, E.
    • Composites Research
    • /
    • v.31 no.6
    • /
    • pp.429-434
    • /
    • 2018
  • We investigate strain transmissions of a surface bonded distributed optical fiber sensor considering strain variation according to positions. We first derive a strain transmission ratio depending on a wavelength of a strain distribution of the host structure from an analysis model. The strain transmission ratio is compared with numerical results obtained from the finite element method using ABAQUS. We find that the analytical results agree well with the numerical results. The strain transmission ratio is a function of a wavelength, i.e. the strain transmission ratio decreases (increases) as the wavelength of the host strain decreases (increases). Therefore, if an arbitrary strain distribution containing various wavelengths is given to a host structure, a distorted strain distribution will be observed in the distributed optical fiber sensor compare to that of the host structure, because each wavelength shows different strain transmission ratio. The strain transmission ratio derived in this study will be useful for accurately identifying the host strain distribution based on the signal of a distributed optical fiber sensor.

Probabilistic Power Flow Studies Incorporating Correlations of PV Generation for Distribution Networks

  • Ren, Zhouyang;Yan, Wei;Zhao, Xia;Zhao, Xueqian;Yu, Juan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.461-470
    • /
    • 2014
  • This paper presents a probabilistic power flow (PPF) analysis method for distribution network incorporating the randomness and correlation of photovoltaic (PV) generation. Based on the multivariate kernel density estimation theory, the probabilistic model of PV generation is proposed without any assumption of theoretical parametric distribution, which can accurately capture not only the randomness but also the correlation of PV resources at adjacent locations. The PPF method is developed by combining the proposed PV model and Monte Carlo technique to evaluate the influence of the randomness and correlation of PV generation on the performance of distribution networks. The historical power output data of three neighboring PV generators in Oregon, USA, and 34-bus/69-bus radial distribution networks are used to demonstrate the correctness, effectiveness, and application of the proposed PV model and PPF method.

The Design Analysis of Distribution Polymer Suspension Insulator (배전용 폴리머 현수애자의 설계해석)

  • Lee, Un-Yong;Cho, Han-Goo;Han, Dong-Hee;Lim, Kee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.66-68
    • /
    • 2001
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission and distribution line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. In this paper, distribution polymer suspension insulator has been designed and investigated electric field distribution by FEM.

  • PDF

Moisture Transfer and Velocity of Moisture Transmission by Wood in Steady State (정상상태(定常狀態)에 있어서 목재(木材)의 습기전달(濕氣傳達)과 투습속도(透濕速度))

  • Lee, Weon Hee
    • Current Research on Agriculture and Life Sciences
    • /
    • v.10
    • /
    • pp.41-47
    • /
    • 1992
  • In general, the behavior of moisture transmission is estimated by vapor permeability or vapor transmission resistance, but its values obtained by experiments do not have great adaptability for practical situations because of changes in the experimental conditions. This fact is why only theoretical discussions have advanced. Thus, the fundamental study of the moisture transmission phenomenon has been treated lightly. Here, as the first step toward the basic research of moisture transmission, the amount of moisture transmission and the moisture distribution in specimens were investigated. The experiment was conducted in a steady state, and the moisture distribution was measured by slicing and weighing the specimens. From the examination of the vapor transmission resistance, the phenomenon of moisture transmission was dealt with devide the moisture transfer on the wood surface and moisture diffusion in wood. The following results were obtained. 1) The phenomenon of moisture transmission should be approached by its division into moisture transfer on the wood surface and moisture diffusion in the wood because the positive values of vapor transmission resistance exist in the extrapolation of thickness 0mm. 2) The distribution of moisture in wood can be illustrated by two straight lines intersecting at the point of nine percent moisture content : namely, diffusion coefficients have two constant values at moisture contents below and above nine percent. The shape of the distribution curve of moisture content is similar irrespective of the wood thickness. On the other hand, when the moisture contents on both sides was more than nine percent, the distribution of the moisture content could be illustrated by one straight lines. 3) The amount of moisture movement is determined by the moisture gradient in wood. 4) Coefficients of the moisture transfer depend on the thickness of the specimens.

  • PDF

A Distributed LT Codes-based Data Transmission Technique for Multicast Services in Vehicular Ad-hoc Networks

  • Zhou, Yuan;Fei, Zesong;Huang, Gaishi;Yang, Ang;Kuang, Jingming
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.4
    • /
    • pp.748-766
    • /
    • 2013
  • In this paper, we consider an infrastructure-vehicle-vehicle (I2V2V) based Vehicle Ad-hoc Networks (VANETs), where one base station multicasts data to d vehicular users with the assistance of r vehicular users. A Distributed Luby Transform (DLT) codes based transmission scheme is proposed over lossy VANETs to reduce transmission latency. Furthermore, focusing on the degree distribution of DLT codes, a Modified Deconvolved Soliton Distribution (MDSD) is designed to further reduce the transmission latency and improve the transmission reliability. We investigate the network behavior of the transmission scheme with MDSD, called MDLT based scheme. Closed-form expressions of the transmission latency of the proposed schemes are derived. Performance simulation results show that DLT based scheme can reduce transmission latency significantly compared with traditional Automatic Repeat Request (ARQ) and Luby Transform (LT) codes based schemes. In contrast to DLT based scheme, the MDLT based scheme can further reduce transmission latency and improve FER performance substantially, when both the source-to-relay and relay-to-sink channels are erasure channels.

Quantitative Evaluation of Dislocation Density in Epitaxial GaAs Layer on Si Using Transmission Electron Microscopy

  • Kim, Kangsik;Lee, Jongyoung;Kim, Hyojin;Lee, Zonghoon
    • Applied Microscopy
    • /
    • v.44 no.2
    • /
    • pp.74-78
    • /
    • 2014
  • Dislocation density and distribution in epitaxial GaAs layer on Si are evaluated quantitatively and effectively using image processing of transmission electron microscopy image. In order to evaluate dislocation density and distribution, three methods are introduced based on line-intercept, line-length measurement and our coding with line-scanning method. Our coding method based on line-scanning is used to detect the dislocations line-by-line effectively by sweeping a thin line with the width of one pixel. The proposed method has advances in the evaluation of dislocation density and distribution. Dislocations can be detected automatically and continuously by a sweeping line in the code. Variation of dislocation density in epitaxial GaAs films can be precisely analyzed along the growth direction on the film.

Condition of Random Distribution of Residual Dispersion Per Span (RDPS) in Optical Transmission Links with Dispersion Management (분산 제어가 적용된 광전송 링크에서 RDPS의 랜덤 분포 조건)

  • Lee, Seong-Real
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.650-652
    • /
    • 2011
  • Condition of random distribution of residual dispersion per span (RDPS) for transmission of 40 Gbps optical signal with good performance through optical transmission links with dispersion management (DM) of random RDPS distribution and optical phase conjugator (OPC) is induced in this paper.

  • PDF

Current Distribution Factor Based Fault Location Algorithms for Double-circuit Transmission Lines (전류분배계수를 사용하는 병행 2회선 송전선로 고장점 표정 알고리즘)

  • Ahn, Yong-Jin;Kang, Sang-Hee;Choi, Myeon-Song;Lee, Seung-Jae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.3
    • /
    • pp.146-152
    • /
    • 2001
  • This paper describes an accurate fault location algorithm based on sequence current distribution factors for a double-circuit transmission system. The proposed method uses the voltage and current collected at only the local end of a single-circuit. This method is virtually independent of the fault resistance and the mutual coupling effect caused by the zero-sequence current of the adjacent parallel circuit and insensitive to the variation of source impedance. The fault distance is determined by solving the forth-order KVL(Kirchhoff's Voltage Law) based distance equation. The zero-sequence current of adjacent circuit is estimated by using a zero-sequence current distribution factor and the zero-sequence current of the self-circuit. Thousands of fault simulation by EMTP have proved the accuracy and effectiveness of the proposed algorithm.

  • PDF

A Study on the Performance of Twin Hull Floating Breakwater (쌍동형 부유식 소파제의 소파성능에 관한 연구)

  • 박노식;엄병섭
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.128-134
    • /
    • 1998
  • This study is carried out the theoretical studies on wave transmission and motions in waves of twin hull type floating breakwaters with the vertical and horizontal plate. The method of calculation is based on the three dimensional singularity distribution method. The results show that wave transmission is affected by heave motion. Twin hull type is designed by the use of the theoretical method and good performance of the developed floating breakwater is confirmed for longer wave period.

  • PDF

Analysis on the relation between electric current and magnetic field near transmission lines (송전선로에서 전류와 자계의 상관관계 분석)

  • Cho, Sung-Bae;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.3-5
    • /
    • 1997
  • The relation between electric current and magnetic field under three overhead transmission lines being operated was studied. It was examined for a difference each other in comparison with calculated value and measured value for current, magnetic field. With magnetic field equations made out, The magnetic field distribution around transmission lines had made to figure out with easy by load electric current value. Additionally, we are going to describe the distribution curve of magnetic exposure volume for KEPCO's T/L.

  • PDF