• Title/Summary/Keyword: transient information

Search Result 715, Processing Time 0.034 seconds

Application of Transient and Frequency Analysis for Detecting Leakage of a Simple Pipeline (누수탐지를 위한 천이류와 주착수분석 적용 연구)

  • Kim, Hyung-Geun;Kim, Hyun-Soo;Lee, Mi-Hyun;Kim, Sang-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1065-1071
    • /
    • 2005
  • Many techniques of leak detection in pipeline systems have developed based on the propagation wave speeds and wave attenuation. In this paper, the transient analysis methodology is used for calculating the wave speed in the plastic pipe and a frequency analysis methodology is developed for leakage detection in water pipe networks. Data acquisition system for pressurized pipeline system were designed md fabricated to obtain high frequency pressure data. The methodology properly handles the unavoidable uncertainties in measurement and modeling error. Based on information from head pressure test data, it provides leak prediction capability from the transient events with leakage.

Quadratic Newton-Raphson Method for DC and Transient Analyses of Electronic Circuits (電子回路의 DC 및 過渡解析을 위한 2次 Newton-Raphson 方法)

  • Jun, Young-Hyun;Lee, Ki-Jun;Park, Song-Bai
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.1
    • /
    • pp.122-128
    • /
    • 1989
  • In this paper we propose a new method for solving a set of nonlinear algebraic equations encountered in the DC and transient analyses of electronic circuits. This method will be called Quadratic Newton-Raphson Method (QNRM), since it is based on the Newton-Raphson Method (NRM) but effectively takes into accoujnt the second order derivative terms in the Taylor series expansion of the nonlinear algebraic equations. The second order terms are approximated by linear terms using a carefully estimated solution at each iteration. Preliminary simulation results show that the QNRM saves the overall computational time significantly in the DC and transient analysis, compared with the conventional NRM.

  • PDF

Large-eddy Simulation of Transient Turbulent Flow in a Pipe (관 내 과도 난류유동에 대한 대형와 모사)

  • Jung, Seo-Yoon;Chung, Yong-Mann M.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.9
    • /
    • pp.720-727
    • /
    • 2008
  • Time delay effects on near-wall turbulent structures are investigated by performing a large-eddy simulation of a transient turbulent flow in a pipe. To elucidate the time delay effects on the near-wall turbulence, we selected the dimensionless acceleration parameter which was used in the previous study. Various turbulent statistics revealed the distinctive features of the delay. It was shown that the dynamic Smagorinsky model is valid to capture the alterations of the turbulence physics well. A dimensionless time for the responses of the flow quantities was introduced to give the detailed information on the delay of the nearwall turbulence. The conditionally-averaged flow fields associated with Reynolds shear stress producing events show that sweep and ejections are closely related to the delays of the turbulence production and the turbulence propagation toward the pipe center. The present study suggested that the enhanced anisotropy of the turbulence in the initial and transient stages would be a challenging problem to standard turbulence models.

Power Cable Ampacity and Influential Factors Analysis under Operation

  • Tong, Qiang;Qi, Jianping;Wang, Yanling;Liang, Likai;Meng, Xiangxing;Zhang, Qiang
    • Journal of Information Processing Systems
    • /
    • v.14 no.5
    • /
    • pp.1136-1149
    • /
    • 2018
  • With the increasing of urban electricity demand, making the most use of the power cable carrying capacity has become an important task in power grid system. Contrary to the rated ampacity obtained under extremely conservative conditions, this paper presents the various steady value of cable ampacity by using the changing surrounding parameters under operation, which is based on cable ampacity calculation equation under the IEC-60287 standard. To some degree, the cable ampacity analysis of actual surroundings improves the transmission capacity of cables. This paper reveals the factors that influence cable ampacity such as insulating layer thickness, allowable long-term conductor temperature, the ambient temperature, soil thermal resistance coefficient, and so on, then gives the class of the influence of these parameters on the ampacity, which plays a great role in accurately calculating the real-time ampacity and improving the utilization rate of cable in the complex external environment condition. Furthermore, the transient thermal rating of the cable is analyzed in this paper, and temperature variation of the conductor under different overload conditions is discussed, which provides effective information for the operation and control of the system.

Analysis of Features and Discriminability of Transient Signals for a Shallow Water Ambient Noise Environment (천해 배경잡음 환경에 적합한 과도신호의 특징 및 변별력 분석)

  • Lee, Jaeil;Kang, Youn Joung;Lee, Chong Hyun;Lee, Seung Woo;Bae, Jinho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.7
    • /
    • pp.209-220
    • /
    • 2014
  • In this paper, we analyze the discriminability of features for the classification of transient signals with an ambient noise in a shallow water. For the classification of the transient signals, robust features for the variance of a noise are required due to a low SNR under a marine environment. In the modelling the ambient noise in shallow water, theoretical noise model, Wenz's observation data from the shallow water, and Yule-walker filter are used. Discrimination of each feature of the transient signals with an additive ambient noise is analyzed by utilizing a Fisher score. As the analysis of a classification accuracy about the transient signals of 24 classes using the selected features with a high discriminability, the features selected in the environment without a noise relatively have a good classification accuracy. From the analyzed results, we finally select a total 16 features out of 28 features. The recognition using the selected features results in the classification accuracy of 92% in SNR 20dB using Multi-class SVM.

Stress Induced Leakage Currents in the Silicon Oxide Insulator with the Nano Structures (나노 구조에서 실리콘 산화 절연막의 스트레스 유기 누설전류)

  • 강창수
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.4
    • /
    • pp.335-340
    • /
    • 2002
  • In this paper, the stress induced leakage currents of thin silicon oxides is investigated in the ULSI implementation with nano structure transistors. The stress and transient currents associated with the on and off time of applied voltage were used to measure the distribution of high voltage stress induced traps in thin silicon oxide films. The stress and transient currents were due to the charging and discharging of traps generated by high stress voltage in the silicon oxides. The transient current was caused by the tunnel charging and discharging of the stress generated traps nearby two interfaces. The stress induced leakage current will affect data retention in electrically erasable programmable read only memories. The oxide current for the thickness dependence of stress current, transient current, and stress induced leakage currents has been measured in oxides with thicknesses between 113.4${\AA}$ and 814${\AA}$, which have the gate area $10^3cm^2$. The stress induced leakage currents will affect data retention and the stress current, transient current is used to estimate to fundamental limitations on oxide thicknesses.

An Analysis of the Transient's Social Behavior in the Radiological Emergency Planning Zone (방사선 비상계획구역에서의 일시거주자의 사회행동 특성 분석)

  • Bang, Sun-Young;Lee, Gab-Bock;Chung, Yang-Geun;Lee, Jae-Eun
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.2
    • /
    • pp.71-78
    • /
    • 2007
  • The purpose of this study is to analyze the social behavior, especially, the evacuation-related social behavior, of the transients in the radiological emergency planning zone(EPZ) of nuclear power plants. So, the meaning and kinds of the evacuation and the significance of the trip generation time(TGT) have been reviewed. The characteristics of the social behavior of the transient around Ulchin, Wolsong and Kori sites was analyzed through field surveys by using the questionnaire. The major findings of this research implications are as follows. First, for securing the safe evacuation, the alternatives to effectively provide the information on the evacuation warning may be prepared. Second, it is necessary to establish the education and training of transient's evacuation. Third, it is needed that the cause and background of the evacuation refusal are identified and the new response plan to secure transient's safety is prepared.

I-PDA Controller Designed by CDM Incorporating FFC for Two-Inertia System

  • Khuakoonrat, Nopnarong;Benjanarasuth, Taworn;Isarakorn, Don;Ngamwiwit, Jongkol;Komine, Noriyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1833-1837
    • /
    • 2004
  • The two-inertia system, which has the torsion vibration, is typically found in several industrial applications. This torsion vibration will effect the quality of the rolled material as well as the stability of the drive system. Thus the speed and torsion vibration of the system have to be properly controlled. This paper, I-PDA controller designed by Coefficient Diagram Method to control a two-inertia system is proposed. The experimental result shows that both of transient and steady state specification can be fulfilled but the transient response still has long rise time. In order to improve the speed of the system response, a phase lag structure of feedforward controller is introduced to I-PDA control system. It is shown that the performance of the I-PDA control system with suitable FFC has shorter rise and settling times, no overshoot and the torsion vibration can be suppressed.

  • PDF

Design of I-PDA Controller Incorporating FFC for Flow Control Systems

  • Cahyadi, A.I.;Khuakoonratt, N.;Benjanarasuth, T.;Ngamwiwit, J.;Komine, N.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1007-1011
    • /
    • 2003
  • In this paper, a design of I-PDA controller by CDM to control a flow process whose structure is first order lag plus a dead time is introduced. The factor of dead time of the process is approximated by second order Pade approximation in order to get a third order system. The simulations show that both of the transient and steady state specifications can be fulfilled. However, the transient response of the I-PDA control system still has long rise time. Then, a feedforward controller (FFC) with two adjustable parameters and one derivative time is introduced into I-PDA control system for improving the speed of the system response. It is shown, from the simulation results, that the performance of the I-PDA control system with suitable FFC has shorter rise time and no overshoot, while settling time remains almost the same. The performance comparison of the proposed control system with the PI control system with and without FFC is also made.

  • PDF

Thermal Model for Power Converters Based on Thermal Impedance

  • Xu, Yang;Chen, Hao;Lv, Sen;Huang, Feifei;Hu, Zhentao
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.1080-1089
    • /
    • 2013
  • In this paper, the superposition principle of a heat sink temperature rise is verified based on the mathematical model of a plate-fin heat sink with two mounted heat sources. According to this, the distributed coupling thermal impedance matrix for a heat sink with multiple devices is present, and the equations for calculating the device transient junction temperatures are given. Then methods to extract the heat sink thermal impedance matrix and to measure the Epoxy Molding Compound (EMC) surface temperature of the power Metal Oxide Semiconductor Field Effect Transistor (MOSFET) instead of the junction temperature or device case temperature are proposed. The new thermal impedance model for the power converters in Switched Reluctance Motor (SRM) drivers is implemented in MATLAB/Simulink. The obtained simulation results are validated with experimental results. Compared with the Finite Element Method (FEM) thermal model and the traditional thermal impedance model, the proposed thermal model can provide a high simulation speed with a high accuracy. Finally, the temperature rise distributions of a power converter with two control strategies, the maximum junction temperature rise, the transient temperature rise characteristics, and the thermal coupling effect are discussed.