• Title/Summary/Keyword: transient identification

Search Result 97, Processing Time 0.022 seconds

A fluid transient analysis for the propellant flow in a monopropellant propulsion system (단일추진제 추진시스템의 과도기유체 해석)

  • Chae J. W.;Han C. Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.173-181
    • /
    • 2005
  • A fluid transient analysis for the propellant flow in a monopropellant propulsion system is conducted using the method of characteristics (MOC). Algebraic simultaneous equations method and Clamor's rule method utilized to drive the compatible and characteristic equations are reviewed to understand MOC more extensively. The identification of fluid transient phenomena of propulsion system of Koreasat 1 is carried out through parametric studies. Also this work describes the reason that the propulsion system of Koreasat 1 has no orifice to control flow transients or to limit the initial hydrazine flow rate for the first-pulse firing.

  • PDF

Optimal design of PID controllers including Smith predictor structure by the model identification (모델 동정에 의한 Smith predictor 구조를 갖는 최적의 PID 제어기 설계)

  • Cho, Joon-Ho;Hwang, Hyung-Soo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.25-32
    • /
    • 2007
  • In this paper, a new method for first order plus dead time(FOPDT) model identification is proposed, which can identity multiple points on a process step response in terms of classification of time response. The process input and output to the test are decomposed into the transient part and the steady-state part. The steady-state part express one FOPDT model and the transient part express variously FOPDT model using least square estimation method. The optimum parameter tuning algorithm for PID controller of the Smith Predictor is proposed through ITAE as performance index. The Simulation results show the validity and improvement of performance for various processes.

Improvement of Steady State Response Using PI+Double Integral Controller (비례적분+이중적분 제어기를 이용한 정상상태 응답 개선)

  • Jung, Gyu Hong
    • Journal of Drive and Control
    • /
    • v.13 no.3
    • /
    • pp.24-31
    • /
    • 2016
  • The performance characteristics of a dynamic control system are evaluated according to the transient and steady-state responses. The transient performance is the controllability of the output for the tracking of the reference or the ability to reduce or reject the effects of unwanted disturbances; alternatively, the steady-state performance is represented by the magnitude of the control error at the steady state. As the effects of the two performances on each other are reciprocal, a controller design that shows a zero steady-state error for the ramp input is uncommon because of the challenge regarding the achievement of an acceptable transient response. This paper proposes a PI+double-integral controller for the elimination of the steady-state error for the ramp input while a sound transient performance is maintained. The control-gain design procedure is described by the second-order response for the step input and the response of the error dynamics for the ramp input. The PI+double-integral controller is designed for the first-order transfer function that is derived from a system identification with the open-loop experiment data of the dc-motor. The simple structure of the proposed controller enables the adoption of a low-end microcontroller for the implementation of a real-time control. The experiment results show that the control performance is as effective as that of the simulation analysis for the operating point of linear system; furthermore, the PI+double-integral controller can be conveniently applied to the control system, which is desirable for the improvement of the steady-state error.

Study on the Parameter Identification for Induction Motors (유도 전동기 파라미터 추정에 관한 연구)

  • 김규식
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.199-202
    • /
    • 2000
  • The accurate identification of the motor parameters in crucially important to achieve high dynamic performance of induction motors. In this paper parameter auto-tuning algorithms for stator(rotor) resistance stator(rotor) leakage inductance mutual inductance and rotor inertia. Stator(rotor) resistance and stator(rotor) leakage inductance are identified based on the stationary coordinate and mutual inductance and rotor resistor on the scalar speed control and the transient motor terminal voltage. To demonstrate the practical significance of our results we present some experimented results.

  • PDF

Single Parameter Fault Identification Technique for DC Motor through Wavelet Analysis and Fuzzy Logic

  • Winston, D.Prince;Saravanan, M.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1049-1055
    • /
    • 2013
  • DC motors are widely used in industries like cement, paper manufacturing, etc., even today. Early fault identification in dc motors significantly improves its life time and reduces power consumption. Many conventional and soft computing techniques for fault identification in DC motors including a recent work using model based analysis with the help of fuzzy logic are available in literature. In this paper fuzzy logic and norm based wavelet analysis of startup transient current are proposed to identify and quantify the armature winding fault and bearing fault in DC motors, respectively. Results obtained by simulation using Matlab and Simulink are presented in this paper to validate the proposed work.

Robustness Analysis of Pulse Response based Identification Methods for First-Order Plus Time-Delay Model (1차 지연시간 모델의 펄스응답기반 식별방식에 대한 강인성 해석)

  • Jin, LiHua;Ryu, Ho-Sun;Kim, Young-Chol
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.83-85
    • /
    • 2007
  • A new approach on identifying a first-order plus time-delay (FOPTD) model using finite--duration pulse inputs has been presented recently [1]. The identification methods are very simple because it is enough to observe only two extremes and the time when they occur in the transient response to pulse input. However, when there is mismatch between actual system and FOPTD model. how sensitive the methods are has not been studied. In this paper, we investigate robustness issue of those identification algorithms in the presence of the model structure mismatch and uncertainties. Through an example we will demonstrate it.

  • PDF

Self-tuning control with improved transient state (초기과도 상태를 개선한 자기 동조 제어 방식)

  • 김운성;배한경;허경무
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.376-381
    • /
    • 1992
  • In this thesis, a self-tuning control method based on Variable Structure System technique for tracking control of Direct-Drive motor is presented. The self-tuning control could not make the tracking error zero in the transient period. This tracking error may be due to disturbances or the error in parameter identification. To overcome this problem, a self-tuning control method based on discrete time VSS technique is presented. The STC based on VSS technique gives good tracking performance of the reference signal in the transient period. The proposed controller is robust to parameter errors and disturbances. The performance of the proposed controller is compared with that of simple STC through digital computer simulation.

  • PDF

THE SENSITIVITY OF STRUCTURAL RESPONSE USING FINITE ELEMENTS IN TIME

  • Park, Sungho;Kim, Seung-Jo
    • Journal of Theoretical and Applied Mechanics
    • /
    • v.3 no.1
    • /
    • pp.66-80
    • /
    • 2002
  • The bilinear formulation proposed earlier by Peters and Izadpanah to develop finite elements in time to solve undamped linear systems, Is extended (and found to be readily amenable) to develop time finite elements to obtain transient responses of both linear and nonlinear, and damped and undamped systems. The formulation Is used in the h-, p- and hp-versions. The resulting linear and nonlinear algebraic equations are differentiated to obtain the first- and second-order sensitivities of the transient response with respect to various system parameters. The present developments were tested on a series of linear and nonlinear examples and were found to yield, when compared with results obtained using other methods, excellent results for both the transient response and Its sensitivity to system parameters. Mostly. the results were obtained using the Legendre polynomials as basis functions, though. in some cases other orthogonal polynomials namely. the Hermite. the Chebyshev, and integrated Legendre polynomials were also employed (but to no great advantage). A key advantage of the time finite element method, and the one often overlooked in its past applications, is the ease In which the sensitivity of the transient response with respect to various system parameters can be obtained. The results of sensitivity analysis can be used for approximate schemes for efficient solution of design optimization problems. Also. the results can be applied to gradient-based parameter identification schemes.

  • PDF

Prediction and Reduction of Transient Vibration of Piping System for a Rotary Compressor (공조용 압축기 배관계의 과도진동 예측 및 저감설계)

  • Ryu, Sang-Mo;Jeong, Weui-Bong;Han, Hyung-Suk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.8
    • /
    • pp.733-740
    • /
    • 2011
  • This paper deals with the process to identify the transient exciting force generated from a rotary compressor. The compressor was assumed to be a rigid body. The equation of motion of a rigid compressor supported by three mounts was derived with 6 degree-of-freedom. The exciting forces at the center of mass of the compressor were estimated from the acceleration data measured at compressor shell. Compressor-pipe system was modeled numerically. The accelerations of compressor and pipe were predicted numerically by using the estimated exciting force. A new shape of pipe model was proposed to reduce the vibration. In the prediction by the method in this paper, the maximum acceleration of the pipe could be reduced by 53.7 % at the steady-state and by 12 % at the transient process. In the real experiments, the maximum acceleration of the pipe was reduced by 54.2 % at steady-state and 14.7 % at the transient process. It was verified that the numerical results showed good agreement with experimental results.

Modeling, Dynamic Analysis and Control Design of Full-Bridge LLC Resonant Converters with Sliding-Mode and PI Control Scheme

  • Zheng, Kai;Zhang, Guodong;Zhou, Dongfang;Li, Jianbing;Yin, Shaofeng
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.766-777
    • /
    • 2018
  • In this paper, a sliding mode and proportional plus integral (SM-PI) control combined with self-sustained phase shift modulation (SSPSM) for LLC resonant converters is presented. The proposed control scheme improves the transient response while preserving good steady-state performance. An averaged large signal model of an LLC converter with the ZVS modulation technique is developed for the SM control design. The sliding surface is obtained based on the input-output linearization concept. A system identification method is adopted to obtain the transform function of the LLC resonant converter, which is used to design the PI control. In order to reduce the inherent chattering problem in the steady state, the combined SM-PI control strategy is derived with fuzzy control, where the SM control is responsive during the transient state while the PI control prevails in the steady state. The combination of SSPSM and the SM-PI control provides ZVS operation, robustness and a fast transient response against step load variations. Simulation and experimental results validate the theoretical analysis and the attractive features of the proposed scheme.