단상(345kV) 주변압기 압력 계전기의 진동절연에 관한 연구 (A Study on the Vibration Reduction of the SPR(sudden pressure relay) in the Single Phase Main Power Transformers(345kV))

  • 박철준;이성욱;최원호;이욱륜;권기영
    • 한국소음진동공학회논문집
    • /
    • 제20권5호
    • /
    • pp.486-491
    • /
    • 2010
  • In this paper, it is identified that high-level vibration of the single phase main power transformers shut down due to the mechanical fault. vibration sources of the SPR in the transformer's are identified and the SPR vibrations are reduced by structural modification. For vibration characteristic identification, vibration signals were measured with an accelerometer when the transformer is driving. These signals are presented in a FFT analysis in order to find the dependency of frequency components on the transformer. From finite element analyses and some experiments, it is also found that resonances occur because the natural frequencies of the SPR exist in usual driving range. To shift the natural frequencies outside the driving range, the SPR is modified by increasing stiffness. It is verified that considerable amounts of vibration are reduced by the structural modification.

X-Ray 진찰용 고전압 공진형 DC-DC 컨버터 설계 (High Voltage Resonant DC-DC Converter Design for X-Ray Imaging)

  • 백종무;주해종;조문택;이충식
    • 한국방사선학회논문지
    • /
    • 제4권4호
    • /
    • pp.11-16
    • /
    • 2010
  • 본 논문은 공진형 인버터로 구성된 X-ray 고전압 발생기와 고주파 고전압 변압기의 운영 시스템을 제안하였다. X선 발생장치는 무소음화와 소형화하였으며, 50[kHz]이상의 구동 주파수로 동작하게 하였고, 일반전원을 사용할 때 발생한 전력으로 인한 노이즈, 조사조건의 저하문제 등의 문제점을 해소하였다. 또한, X선관 전압 제어기와 관전류 제어기 및 고주파 고전압 변압기의 필라멘트 가열용 변압기를 고주파용으로 설계, 제작함으로써 X선 장치의 효율적 운영이 되도록 하였다.

$SF_6$가스절연 변압기 ($SF_6$ Gas Insulated Transformer)

  • 조광제;홍기돈;하영식;조규복;노철웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.304-309
    • /
    • 1991
  • We introduce the trend, of several countries, to the gas insulated transformer recently coming into the spot light by the advantages of less weight, GIS-lization, low noise level and easiness to decrease environmental pollutions, and the insulating gases. the cooling media and the insulating materials used for transformer. Hereinafter, additively the design of proto type $SF_6$ gas insulated transformer (insulation, cooling), which was developed by us(HICO) from 1987. 2 through 1990. 3, the manufacturing processes(leak protection, pressure, drying of main body), the accessories, the protective system, the cooling system, the method and the results of test and the evaluation of economics compared with conventional oil-filled transformer are represented.

  • PDF

변압기 사고 검출을 위한 진동신호 연구 (A Study on the Vibration Signal for Detection of Power Transformer Failure)

  • 김현식;강창구;정찬수;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.493-495
    • /
    • 1995
  • Recently, as power transformer capacity is getting larger, vibration noise of transformer would be large and unexpected failuare of transformer give enormous economic loses, So we aquaire vibration signal, which is maked from transformer windings, core that are airtight out box with in insulation oil, and out box. Also we are fixed rated voltage and changing load current, analyize frequency domain of each vibration signals.

  • PDF

전력용 변압기에서의 초음파 노이즈 (Ultrasonic Noises in Power Transformer)

  • 권동진;정길조;최인혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2305-2307
    • /
    • 1999
  • Partial discharge measurement using a ultrasonic technique allows us to detect degradation of the electrical insulation in a power transformer. However, The ultrasonic measurement studies don't offer a good solution in operating conditions. In this paper, we investigated characteristics of ultrasonic noise caused by a 345kV power transformer under operating conditions. The ultrasonic noises generated by corona in air, vibration of core, pump and fan, etc. An ultrasonic frequency caused by corona in air was appeared 9 and 18[MHz] at the outside wall of the transformer. And a spectra of core vibration was detected below 2.5[kHz]. These spectrum were compared with 20 $\sim$ 200[kHz] of the internal partial discharge in the model transformer.

  • PDF

차량탑재형 HFPD의 개발 (The Development of HFPD System for Mibile-loading Vehicles)

  • 김덕근;임장섭;여인선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.33-37
    • /
    • 2001
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

압전 변압기를 이용한 LCD Backlight 구동에 관한 연구 (A Study on the LCD Backlight Drive using Piezoelectric Transformer)

  • 강태구;이동균;유영한;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.273-277
    • /
    • 1999
  • A cold cathode flourescent lamp for the backlight in the notebook computer requires high input voltage about 1300(V) when it turns on. But once a discharge starts, the input voltage can be dropped by about one-third for continued output. The equivalent impedance also varies from open to several dozens of kilo-ohms. The piezoelectric transformer converts electrical energy into mechanical energy and then converts it back to electrical energy at a high voltage. Its high output voltage, high efficiency and small size are suitable for driving the LCD backlight in the notebook computer. The piezoelectric transformer operates near the resonance frequency and the output waveform is close to sine wave with very little noise. This paper suggests an inverter for LCD backlight of notebook computer using piezoelectric transformer that includes voltage to frequency converter for gate signal which is useful for tracking of variable resonance frequency depending on load impedance.

  • PDF

A Low-Spur CMOS PLL Using Differential Compensation Scheme

  • Yun, Seok-Ju;Kim, Kwi-Dong;Kwon, Jong-Kee
    • ETRI Journal
    • /
    • 제34권4호
    • /
    • pp.518-526
    • /
    • 2012
  • This paper proposes LC voltage-controlled oscillator (VCO) phase-locked loop (PLL) and ring-VCO PLL topologies with low-phase noise. Differential control loops are used for the PLL locking through a symmetrical transformer-resonator or bilaterally controlled varactor pair. A differential compensation mechanism suppresses out-band spurious tones. The prototypes of the proposed PLL are implemented in a CMOS 65-nm or 45-nm process. The measured results of the LC-VCO PLL show operation frequencies of 3.5 GHz to 5.6 GHz, a phase noise of -118 dBc/Hz at a 1 MHz offset, and a spur rejection of 66 dBc, while dissipating 3.2 mA at a 1 V supply. The ring-VCO PLL shows a phase noise of -95 dBc/Hz at a 1 MHz offset, operation frequencies of 1.2 GHz to 2.04 GHz, and a spur rejection of 59 dBc, while dissipating 5.4 mA at a 1.1 V supply.

저소음 변압기용 조립식 철판 방음실 개발 (Development of an Acoustic Enclosure for the Large Low-Noise Transformer)

  • 이준신;이욱륜;손석만;구교선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.87-88
    • /
    • 2007
  • An acoustic total or partial enclosure is widely used to reduce the sound pressure level propagating from a noise source. However, the performance of the acoustic enclosure is decreased by its inherent limitations such as temperature rise or acoustic pressure build-up inside the enclosed acoustic field. In this reason, an acoustic enclosure consisting of a silencer and absobent panels with acoustic resonators is studied to reduce the transmitted noise from a transformer. Large sound-attenuation is expected by applying the enclosure to the large transformers in a substation.

  • PDF