• 제목/요약/키워드: transducer design

검색결과 383건 처리시간 0.024초

Radiation characteristics analysis of Langevin transducer having a rim-fixed circular plate (주위가 고정된 원형 평판을 가진 란주반 트랜스듀서의 방사 특성 해석)

  • Jungsoon Kim;Jiwon Yoon;Moojoon Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • 제43권4호
    • /
    • pp.391-399
    • /
    • 2024
  • In order to analyze the distribution of sound fields radiating from a circular plate vibrated by a Langevin transducer, a theoretical analysis model was derived. The boundary conditions of the driving area and fixed boundary area were appropriately applied to the equation of motion of the vibrating plate, which was derived by L. Rayleigh. By calculating the vibration displacement distributed on the surface of the vibrating plate using the derived analysis model and then calculating the sound field formed by the ultrasonic waves radiating from it, it was confirmed that the radiation characteristics vary significantly depending on the area of the vibrating plate. For comparison, a simulation of the same system was performed using the COMSOL program, a finite element method, and showed good agreement with the theoretical calculation results, confirming the effectiveness of the theoretical analysis model derived in thisstudy. It is expected that the theoretical analysis model derived from this study can be used in the design and development of related devices, such as in the ultrasonic chemistry field.

Flow characteristics at the Impeller Exit of a Centrifugal Pump (원심펌프의 회전차 출구 유동 특성)

  • Hong, Soon-Sam;Kang, Shin-Hyoulg
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.36-44
    • /
    • 2000
  • The flow at the impeller exit is important to validate engineering design and numerical analysis of pumps. We installed axisymmetric collector instead of the volute casing, so there is no interaction between the impeller and casing. A hot-film probe and a high response pressure transducer are used to investigate the flow at impeller exit and vaneless diffuser region for design and off design flow rate. For a single suction centrifugal pump of low specific speed, the flow field such as velocity, flow angle, and total pressure are measured by traversing the probe across the vaneless diffuser. These data can be used for performance prediction, design, and numerical analysis of pumps.

  • PDF

The Design of Broadband Ultrasonic Transducers for Fish Species Identification - Dual Resonance Design of a Ultrasonic Transducer Using a Single Acoustic Matching Layer - (어종식별을 위한 광대역 초음파 변환기의 설계 II - 단일음향정합층을 이용한 이중공진형 변환기의 설계 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • 제34권1호
    • /
    • pp.74-84
    • /
    • 1998
  • A doubly resonant ultrasonic transducer has been designed as an attempt to increase the bandwidth of underwater transducers. The dual resonance conditions were accomplished by attaching a single acoustic matching layer on the front face of a Tonpilz transducer consisted of an aluminum head, a piezoelectric ring, a brass tail and a prestress bolt. A modified Mason's model was used for the performance analysis and the design of transducers, and the constructed transducers were tested experimentally and numerically by changing the impedances and thicknesses of the head, tail and matching layers in the water tank. Two distinct resonance peaks in the transmitting voltage response(TVR) of a developed transducer were observed at 34.3 and 40.4 kHz, respectively, with the difference frequency of 6.1kHz and the center frequency of 37.2kHz. The values of TVR at these frequencies were 136.5 dB re $1\;\muPa/V$ at 34.3 kHz and 136.8 dB re $1\;\muPa/V$ at 40.4 kHz, respectively. Reasonable agreement between the experimental results and the numerical results was achieved. From this result, it is expected that the generation of the distinct resonances at any two desired frequencies can be achieved through the proper choice of the matching layer to provide the impedance transformation between the transducer and the medium.

  • PDF

A Study on the Broadband Microwave Amplifier Design Using Potentially Unstable GaAs FET (Potentially Unstable한 GaAs FET를 이용한 광대역 마이크로파증폭기에 관한 연구)

  • Hong, Jae-Pyo;Cho, Young-Ki;Son, Hyon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제12권1호
    • /
    • pp.19-26
    • /
    • 1987
  • The broadband microwave amplifier in the 3~4GHz frequency range has been designed by using potentially unstable GaAs FET. Input matching network is designed by 14dB available power gain circles which are in the stable region. In order to obtain maximu, transducer power gain, output matching network which is in the stable region can be designed using Fano's bandpass matching network. The measured values of transducer power gain, $S_11$and $S_22$ show close agreements with the theoretical valuse.

  • PDF

Detection of Plethysmogram and its Usefulness (맥파검출과 이의 유효성)

  • 홍승홍
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • 제15권1호
    • /
    • pp.1-4
    • /
    • 1978
  • This paper described the establishment of the basic data for the design of the transducer for the detection of plethysmogram, the structure of pulsimeter utilizing the designed transducer and the clinical usefulness of detected waveform of the optical detection method can be utilized as an information of cardiovascular system as physiological theoretical waveform of aorta, and derivative of plethysmogram by piezo electric elements clearly shows the information of incisura which does not appear at the old age and this makes the measuring of ejection time to be easy. The ejection time of average for 42 persons shows 0.324 $\pm$ 0.027 sec. and this value is in good agreement with the theoretical value, and the possibility of measuring the velocity of pulse conduction has been studied.

  • PDF

Optimal Design of Deep-water 30 kHz Omnidirectional Sonar Transducer using a Coupled FE-BEM (결함형 유한요소-경계요소 기법에 의한 심해저용 30 kHz 전방향성 소나 변환기 최적 설계)

  • Jarng Soon Suck;Choi Heun Ho;Lee Je Hyeong;Ahn Heung Gu
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 한국음향학회 1999년도 학술발표대회 논문집 제18권 2호
    • /
    • pp.275-280
    • /
    • 1999
  • Deep-water sonar transducers of FFR (Free Flooded Ring) type have been designed using a coupled FE-BEM. The proposed sonar transducers are composed of piezoelectric ceramic tubes and structural steel materials for simple fabrication. In order to have an omnidirectional beam pattern around 30 kHz, a conic steel is placed below a piezoelectric tube or a steel disc is placed between two piezoelectric tubes. The dynamics of the sonar transducer is modelled in three dimensions and is analyzed with external electrical excitation conditions. Various results are available such as directivity patterns and transmitting voltage responses. The most optimal structure and dimensions of the steel material were calculated, so that the beam patterns of the sonar transducers had +/- 3 dB omnidirectivity at 30 kHz.

  • PDF

Implementation of IEEE 1451 based Dual CAN Module for Fault Tolerance of In-Vehicle Networking System (차량 네트워크 시스템의 결함 허용을 위한 IEEE 1451 기반 중복 CAN 모듈의 구현)

  • Lee, Jong-Gap;Kim, Man-Ho;Park, Jee-Hun;Lee, Suk;Lee, Kyung-Chang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • 제15권7호
    • /
    • pp.753-759
    • /
    • 2009
  • As many systems depend on electronics in an intelligent vehicle, concern for fault tolerance is growing rapidly. For example, a car with its braking controlled by electronics and no mechanical linkage from brake pedal to calipers of front tires(brake-by-wire system) should be fault tolerant because a failure can come without any warning and its effect is devastating. In general, fault tolerance is usually designed by placing redundant components that duplicate the functions of the original module. In this way a fault can be isolated, and safe operation is guaranteed by replacing the faulty module with its redundant and normal module within a predefined interval. In order to make in-vehicle network fault tolerant, this paper presents the concept and design methodology of an IEEE 1451 based dual CAN module. In addition, feasibility of the dual CAN network was evaluated by implementing the dual CAN module.

MODE CONTROL OF GUIDED WAVE IN MAGNETIC HOLLOW CYLINDER USING ELECTROMAGNETIC ACOUSTIC TRANSDUCER ARRAY

  • FURUSAWA, AKINORI;KOJIMA, FUMIO;MORIKAWA, ATSUSHI
    • Nuclear Engineering and Technology
    • /
    • 제47권2호
    • /
    • pp.196-203
    • /
    • 2015
  • The aim of this work is to demonstrate a method for exciting and receiving torsional and longitudinal mode guided waves with an electromagnetic acoustic transducer (EMAT) ring array. First of all, a three-dimensional guided wave simulator is developed in order to numerically analyze the propagation of the guided wave. The finite difference time domain method is used for the simulator. Second, two guided wave testing systems using an EMAT ring array are provided: one is for torsional mode (T-mode) guided wave and the other is for longitudinal mode (L-mode). The EMATs used in the both systems are the same in design. A method to generate and receive the T- and L-mode guided waves with the same EMAT is proposed. Finally, experimental and numerical results are compared and discussed. The results of experiments and simulation agree well, showing the potential of the EMAT ring array as a mode controllable guided wave transmitter and receiver.

Radial Pulse Wave Detection system for the Korean Medicine (한방용(韓方用) 맥파 검출시스템)

  • Lee, H.J.;Kim, J.W.;Kim, H.O.;Park, Y.B.;Huh, W.
    • Proceedings of the KOSOMBE Conference
    • /
    • 대한의용생체공학회 1991년도 추계학술대회
    • /
    • pp.66-69
    • /
    • 1991
  • This paper describes a design of transducer for non-invasively detecting pressure radial pulse wave in aterial system and a recording system that for the studing the aterial pulse diagnosis of korean traditional medicine. The mechanism of transducer is composed of sensing mechanism, pressure sensor, conditioning amplifier. The variation of radial pulse pressure in the sensing mechanism is converted to the electric signal by piezo-resistive pressure sensor and it converted to the digital signal after preprocessing via A/D converter. The converted signals inputed to the computer as data files and then it display to the monitor for waveform watching and this datas can be used as the aterial pulse diagnosis data. This system effectively detect non-differential radial pulse wave and we conside that if analizing the recorded radial pulse wave, compared each other, it can be helpful in quantify radial pulse wave diagonosis of the Korean traditional medicine.

  • PDF

A study on the multi-point signal detection, using Passive band-pass filter in FBG Hydrophone (FBG(Fiber Bragg Grating) Hydrophone에서 Passive Band-Pass Filter를 사용한 다중점 신호 검출에 관한 연구)

  • Kim, Kyung-Bok;Kwack, Kea-Dal
    • Journal of Sensor Science and Technology
    • /
    • 제9권4호
    • /
    • pp.307-315
    • /
    • 2000
  • To set up the arrays system of FBG(Fiber Bragg Grating) Hydrophone sensor and realize the multi-point signal detection for the wide scope underwater, using WDM(Wavelength Division Multiplexing) method and Passive band-pass filter system, underwater acoustic signal detection of the newly designed two FBG Transducers is successfully experimented. As a result of the experiment, it was possible each signal with different frequent signals is detected for the multi-point up to 1.3KHz in underwater. We can, therefore, prove the possibility on the system design of Hydrophone sensor arrays, using the newly made FBG Transducers.

  • PDF