• Title/Summary/Keyword: total floor space

Search Result 103, Processing Time 0.023 seconds

A Layout Planning Optimization Model for Finishing Work (건축물 마감공사 자재 배치 최적화 모델)

  • Park, Moon-Seo;Yang, Young-Jun;Lee, Hyun-Soo;Han, Sang-Won;Ji, Sae-Hyun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.1
    • /
    • pp.43-52
    • /
    • 2011
  • Unnecessary transportation of resources are one of the major causes that adversely affect construction site work productivity. Therefore, layout related studies have been conducted with efforts to develop management technologies and techniques to minimize the resource transportation made at site-level. However, although the necessity for floor-level layout planning studies has been increasing as buildings have become larger and floors have become more complicated, studies to optimize the transportation of materials inside buildings are currently not being actively conducted. Therefore, in this study, a model was developed using genetic algorithms(GA) that will enable the optimization of the locations of finishing materials on the work-floor. With the established model, the arrangement of diverse materials on complicated floors can be planned and the optimized material layout planning derived from the model can minimize the total material transportation time spent by laborers during their working day. In addition, to calculate travel distances between work sites and materials realistically, the concept of actual travel distances was applied. To identify the applicability of the developed model and compare it with existing methodologies and analyze it, the model was applied to actual high-rise residential complexes.

Analysis of Land Use Characteristics Using GIS DB - A Case Study of Busan Metropolitan City in Korea - (GIS DB를 이용한 토지이용 특성 분석 - 부산광역시 건물 높이 시뮬레이션을 중심으로 -)

  • Min-Kyoung CHUN;Tae-Kyung BAEK
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.3
    • /
    • pp.52-64
    • /
    • 2023
  • As cities continue to develop rapidly, overcrowding, pollution, and urban sanitation problems arise, and the need to separate conflicting uses is emerging. From this perspective, there is no disagreement that urban land use should be planned. Therefore, all activities in land space must be predicted in advance and planned so that land use can be rationally established. This study used the constructed data to compare and analyze the use distribution characteristics of residential, commercial, and industrial areas in Busan Metropolitan City to identify the building area status, total floor area, and floor area ratio by use zone in districts and counties in Busan Metropolitan City. As a result, it was found that the residential area accounted for the largest proportion of the area by use zone at 51%, and that the residential area accounted for the largest proportion at 63% of the total floor area by use zone. And the analysis was conducted using a specialization coefficient that can identify regional characteristics based on land use composition ratio. Because it is difficult to determine the trend of the entire region just by counting the absolute value of the area, the area composition ratio was calculated and compared. Looking at the residential facilities among the specialization coefficients by use area, it is above 1.0 except for Gijang-gun, Sasang-gu, Saha-gu, and Jung-gu. Commercial facilities are over 1.0 except for Gijang-gun, Gangseo-gu, Nam-gu, Sasang-gu, and Saha-gu. Looking at industrial facilities, you can see that the industrial complex distribution area is Gangseo-gu (2.5), Gijang-gun (1.22), Sasang-gu (2.06), and Saha-gu (1.64). In addition, it was found that business facilities and educational welfare facilities were evenly distributed. Land use analysis was conducted through simulation of the current status of building heights according to each elevation in each use area and the height of buildings in each use area. In general, areas over 80m account for more than 43% of Busan City, showing that the distribution of use areas is designated in areas with high altitude due to the influence of topographical conditions.

An Analysis of Characteristics of Literature on the Residential Environments of Korean-Chinese People Residing in China (중국 조선족 거주환경 관련연구의 동향분석)

  • Heo, Seong-Geol;Cho, Won-Seok;Byun, Kyeonghwa
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.17 no.1
    • /
    • pp.105-112
    • /
    • 2015
  • The purpose of this study is to analyze characteristics of literature on the residential environments of Korean-Chinese people residing in China. The number of such studies on residential environment is a total of 123, of which 86 (69.9%) are Korean studies and 37 (30.1%) are Chinese studies. Research has been conducted in China since the 1980s, but from 1990s onward, research was conducted in Korea following the establishment of diplomatic ties between the two nations. More studies related to history, society, and tradition have been conducted in China than Korea because China is a multiracial nation and Korean-Chinese people comprise an ethnic minority. In terms of residential environment, the majority of studies are related to architecture and space and are typically focused on villages and housing. Studies on traditional housing of the Korean-Chinese focus on general characteristics of traditional housing, targeting China's three northeast provinces and the Yanbian Korean Autonomous Prefecture of China. Studies on modern housing of the Korean-Chinese have mainly been conducted in Yanji City in China. The reason for this is that 41% of Yanji City's population is Korean-Chinese, a distinct difference can be seen between Yanji City and other areas regarding changes of modern housing, and ondol (the traditional Korean floor heating system) is commonly found in modern housing there.

Significance of In-Situ Stresses in Stability Analysis of Underground Nuclear Waste Disposal Repository (방사성 폐기물 지하처분장의 안정성 분석에 있어서 암반내 초기응력의 역할과 의미)

  • Choi, Sung-O.
    • Tunnel and Underground Space
    • /
    • v.17 no.1 s.66
    • /
    • pp.26-31
    • /
    • 2007
  • The 11 nuclear power plants have been taking charge of more than 40% of the total electrical power development in Korea. In addition to the existing nuclear power plants at Gori, Wolsung, Youngkwang, etc., the 12 nuclear power plants are expected to be newly established until 2006. So, the 23 nuclear power plants will produce the electric power as much as more than 50% of the national gross production. However the nuclear power plants are inevitably generating the detrimental atomic wastes. Therefore the disposal techniques for the nuclear wastes should be ensured considering a very high safety factor. According to the basic researches in KAERI, the underground disposal repositories are reported to be most favorable for Korea. The KBS-3 disposal system has been strongly suggested by KAERI and this system has a deep tunnel with several disposal boreholes in tunnel floor. The nuclear wastes, which are sealed tightly in a canister, will be disposed in these boreholes. Considering the disposal tunnel in a great depth, the in-situ stress regimes will affect severely the tunnel stability. Consequently the effect of the in-situ stresses on the disposal tunnel and the role of the in-situ stresses in tunnel stability analysis are examined by the numerical studies.

A Study on School Dietitians' Satisfaction with Foodservice Facilities and Utilities in the Chonbuk Area of Korea (전북 지역 학교 급식 영양사의 학교 급식 시설${\cdot}$설비에 대한 만족도 연구)

  • Choi, Hyu-Yeun;Rho, Jeong-Ok
    • The Korean Journal of Food And Nutrition
    • /
    • v.20 no.2
    • /
    • pp.218-225
    • /
    • 2007
  • This study was conducted to investigate the satisfaction of school dietitians with foodservice facilities and utilities in the Chonbuk area of Korea. Self-administered questionnaires were collected from a total of 22 dietitians. Statistical data analysis was completed using the SPSS v. 10.0 program. The results are summarized as follows. Among the 222 school foodservice systems, 68.5% of the schools prepared meals the conventional way and 31.5% prepared them the commissary way. Most of the school foodservice facilities were located on the first floor. Satisfaction with the location of the foodservice facility was not significantly different between the conventional and commissary systems. However, overall dietitian satisfaction with the foodservice facility locations was poor. Approximately 30% of the dietitians responded that one of the most important problems for foodservice management was the limited space and worn-out equipments in the kitchens. For dietitians' satisfaction on the types of facilities present, most schools had constructed dietitian offices, food storage facilities, cafeterias, rest rooms, dressing rooms, and preparation facilities. Yet, the amenities most often missing were storage facilities, preparation facilities, dressing rooms, rest rooms, etc. For overall satisfaction with the status of facilities and utilities, we found no significant differences between dietitians in the conventional(2.89) and commissary foodservice systems(2.86); however, the satisfaction level among the dietitians was poor. Therefore, governmental regulation agencies need to review and approve plans prior to the new construction or extensive remodeling of school foodservice facilities. Finally, content analysis was also conducted regarding the dietitians' opinions on foodservice facilities and utilities.

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.

A Study on the Spatial Image and Visual Preference for Front Gardens of High School (고등학교 전정의 공간 Image와 시각적 선호도 조사에 관한 연구)

  • 진희성;서주환
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.13 no.2
    • /
    • pp.37-70
    • /
    • 1985
  • The purpose of this study is to present objective basic data for environmental design by the quantitative analysis of visual quality emboded in physical environment. For this, as for the front garden of high schools, the spatial image was measured by the S.D. Scale Method, Factor Analysis was proceeded by the principal component analysis and the visual preference was investigated by the Paired Comparision Method. The scale values of plain and unpleasant road surface and external appearance of buildings, which are related to emotions of simpleness fell from straightness and stability, were found to be high. But, except for the road surface of Kyunggi High School, scale values of variables explaining the variation of the quality of materials, level of floor and rythm were generally low. For all green spaces, scale values of variables explaining the degree of pleasantness was found to be generally high. And, those explaining tidiness and characteristics of green spaces were not in the same tendency. But, the green spaces of Youngdong High school can be considered to the space with plenty of visual absorption uniqueness were high. As for the correlation between variables, variables for green spaces(12 and 26) and those for overall view of front garden( 1 and 4) revealed high positive correlation. Also, "order - disorder" and "convenient- incovenient" included in road surface variable can be regarded to have the same meaning since the correlation coefficient between them is very high, 0.7045. Image variables including road surface, external appearance of buildings, green spaces and overall view of front garden showed 91.21~61.08% of total variance. Thus, the remains can be considered to be the error valiance or specific variance. In Fctor I, II and III, main components explaining the road surface image of front gardens are order, hardness, texture, color, gradient and rythm. As for the external appearance of b wilding, variables of color, hardness, stability, peculiality and shape revealed high values of factor load. For all variables, communality was drastically high and ellen values and common variance were found to be very high in Factor I. As for the front gardens, variables explaining volume and peculiarity were found to be the main components of Factor I. In Factor II and III, variables of factor load were tidiness, pleasantness.

  • PDF

A Study on the Reduction effect of Peak Cooling Load on the Sunshade effect of BIPV System (BIPV 시스템의 차양 효과에 따른 피크 냉방부하 절감효과에 관한 연구)

  • Lee, Chung-Sik;Lee, Eung-Jik;Lee, Chul-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.14-20
    • /
    • 2008
  • As the number of buildings that use the transparent permeation materials as the outer wall is on the increase, the coming amount of the light rays is a lot, and thus the increase in the cooling load and the radiant heat of high temperature may cause the residents to discomfort. In order to reduce such influences, this paper analyzed the installation effects of the sunshade BIPV. The inner temperature of the room installed the sunshade BIPV or otherwise was measured, and compared and analyzed the effects of reducing the cooling load by the incoming light rays. The sample space of the third floor of S university installed the sunshade BIPV has two rooms on the same conditions, and for five sunny days selected in August, the researcher measured the air temperature and the temperature of the fittings with closing the windows to minimize the movement of air without operating the coolers. The maximum cooling load measured by the incoming light rays in the room where the sunshade BIPV was not installed was examined as 459.13kcal/h. It can be understood as the effect of reducing the cooling load according to the incoming rays of the room with sunshade BIPV. Even though the effect of cooling load reduction is not so great in a room, the total reduction in cooling room for the 32 rooms installed the sunshade BIPV was estimated to be 40442.27kcal/day, which will be able to bring the maximum reduction effect of 17.1kW in energy and reduce the investment cost owing to the reduction in cooling load when initially designing the building.

Feasibility of UHPC shields in spent fuel vertical concrete cask to resist accidental drop impact

  • P.C. Jia;H. Wu;L.L. Ma;Q. Peng
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4146-4158
    • /
    • 2022
  • Ultra-high performance concrete (UHPC) has been widely utilized in military and civil protective structures to resist intensive loadings attributed to its excellent properties, e.g., high tensile/compressive strength, high dynamic toughness and impact resistance. At present, aiming to improve the defects of the traditional vertical concrete cask (VCC), i.e., the external storage facility of spent fuel, with normal strength concrete (NSC) shield, e.g., heavy weight and difficult to fabricate/transform, the feasibility of UHPC applied in the shield of VCC is numerically examined considering its high radiation and corrosion resistance. Firstly, the finite element (FE) analyses approach and material model parameters of NSC and UHPC are verified based on the 1/3 scaled VCC tip-over test and drop hammer test on UHPC members, respectively. Then, the refined FE model of prototypical VCC is established and utilized to examine its dynamic behaviors and damage distribution in accidental tip-over and end-drop events, in which the various influential factors, e.g., UHPC shield thickness, concrete ground thickness, and sealing methods of steel container are considered. In conclusion, by quantitatively evaluating the safety of VCC in terms of the shield damage and vibrations, it is found that adopting the 300 mm-thick UHPC shield instead of the conventional 650 mm-thick NSC shield can reduce about 1/3 of the total weight of VCC, i.e., about 50 t, and 37% floor space, as well as guarantee the structural integrity of VCC during the accidental drop simultaneously. Besides, based on the parametric analyses, the thickness of concrete ground in the VCC storage site is recommended as less than 500 mm, and the welded connection is recommended for the sealing method of steel containers.

A Study on the Emotional Reaction to the Interior Design - Focusing on the Worship Space in the Church Buildings - (실내공간 구성요소에 의한 감성반응 연구 - 기독교 예배공간 강단부를 중심으로 -)

  • Lee, Hyun-Jeong;Lee, Gyoo-Baek
    • Archives of design research
    • /
    • v.18 no.4 s.62
    • /
    • pp.257-266
    • /
    • 2005
  • The purpose of this study is to investigate the psychological reaction to the image of the worship space in the church buildings and to quantify its contribution of the stimulation elements causing such reaction, and finally to suggest basic data for realizing emotional worship space of the church architecture. For this, 143 christians were surveyed to analyze the relationship between 23 emotional expressions extracted from the worship space and 32 images of the worship space. The combined data was described with the two dimensional dispersion using the quantification theory III. The analysis found out that 'simplicity-complexity' of the image consisted of the horizontal axis (the x-axis) and 'creativity' of the image the vertical axis(the y-axis). In addition, to extract the causal relationship between the value of emotional reaction and its stimulation elements quantitatively, the author indicated 4 emotional word groups such as simple, sublime for x-axis and typical creative for y-axis based on its similarity by the cluster analysis, The quantification theory I was also used with total value of equivalent emotional words as the standard variance and the emotional stimulation elements of the worship space as the independent variance. 9 specific examples of the emotional stimulation elements were selected including colors and shapes of the wall and the ceiling, shapes and finish of the floor materials, window shapes, and the use of the symbolic elements. Furthermore, 31 subcategories were also chosen to analyse their contribution on the emotional reaction. As a result, the color and finish of the wall found to be the most effective element on the subjects' emotional reaction, while the symbolic elements and the color of the wall found to be the least effective. It is estimated that the present study would be helpful to increase the emotional satisfaction of the users and to approach a spatial design through satisfying the types and purposes of the space.

  • PDF