임플란트 보철 치료에서 지대주 선택시 고려사항과 임상적 적용 (Considerations and clinical appliances of various abutments in implant prostheses)

  • 박성우;김선재;장재승
    • 대한치과의사협회지
    • /
    • 제54권3호
    • /
    • pp.191-197
    • /
    • 2016
  • In the past, restoration of implant crown, ready-made abutment produced by implant manufacturer could only be used. Using straight, angled abutment, there was a limit in adaptation multiple implants. Recently, with the development of implant and CAD/CAM technology, CAD/CAM customized abutment use has become possible which is different from the past when restoration was possible with only prefabricated abutment. Not only it makes emergence profile possible which is similar to natural teeth, but also it makes insertion path possible on CAD in multiple implant restorations. However, on anterior teeth which dental esthetics is very important, another restorations which are formed with natural colored gingiva area could be required. Titanium-based zirconia prostheses which have titanium connection and zirconia structure from 1mm above fixture platform are alternative. Therefore, the purpose of this review is to analyze the characteristics, advantages and disadvantages of the abutment which is used in multiple implant restorations, and to choose right abutment when clinical trials.

  • PDF

자기공명영상이 인체에 미치는 영향 : 치아임플란트 재료에 따른 차이 분석 (Effects of Magnetic Resonance Imaging on the Human Body : Analysis of differences according to Dental Implant Material)

  • 최대연;김동현
    • 한국방사선학회논문지
    • /
    • 제12권4호
    • /
    • pp.481-489
    • /
    • 2018
  • Brain MRI 검사에서는 영상을 얻기 위해 RF Pulse를 인체에 조사하게 되는데 이때 조사된 RF Pulse 에너지의 상당부분은 우리 몸에 그대로 흡수되게 되고 이로 인해 인체의 온도가 상승하게 되는데 노출정도에 따라 인체에 영향을 주게 된다. 그리고 같은 RF Pulse 에너지를 주었더라도 인체에 금속이 삽입되었다면 금속으로 인한 전자파 전도도가 증가하기 때문에 SAR가 증가하고 체온도 변화하게 된다. 이에 Brain MRI검사 시 치아 임플란트의 재료에 따라 발생되는 두부 전체의 SAR와 온도의 변화를 비교 분석하고자 한다. 실험은 인체 두부모델에 1.5Tesla MRI장비에서 발생되는 64MHz RF Pulse 주파수, 3.0Tesla MRI장비에서 발생되는 128MHz RF Pulse 주파수를 조사한 뒤 치아 임플란트 재료를 Titanium과 $Al_2O_3$로 변화시킨 경우 두부 전체의 SAR와 온도 변화를 알아본다. 치아 임플란트 재료의 변화에서 Titanium을 사용하였을 때, 두부 전체의 SAR와 온도는 높게 나타났다. 하지만 $Al_2O_3$을 사용하였을 때, Titanium보다 두부 전체의 SAR와 온도는 낮게 나타났다. 치아 임플란트의 재료는 금속의 비중이 작은 경금속이면서 전기적 도체인 Titanium과 비교했을 때 전기전도도가 낮은 전기적 부도체인 $Al_2O_3$에서 두부 전체의 SAR와 온도는 낮게 나타났다. 치아 임플란트 재료가 Titanium 일 경우 SAR의 최대값은 제한치보다 월등히 높기 때문에 향후 Titanium의 치아 임플란트 재료를 삽입한 환자가 Brain MRI 검사를 할 경우 환자의 생물학적 영향과 관련된 연구가 필요할 것이다. 또한, 치아 임플란트 시술 시 Titanium보다는 $Al_2O_3$ 재질의 치아 임플란트를 사용하는 것이 Brain MRI 검사에서 인체 두부 전체의 SAR와 온도를 감소시키는 방안이라는 점을 발견할 수 있었다.

Finite element study on the effect of abutment length and material on implant bone interface against dynamic loading

  • Mishra, Manish;Ozawa, Shogo;Masuda, Tatsuhiko;Yoshioka, Fumi;Tanaka, Yoshinobu
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권3호
    • /
    • pp.140-144
    • /
    • 2011
  • PURPOSE. Finite element study on the effect of abutment length and material on implant bone interface against dynamic loading. MATERIALS AND METHODS. Two dimensional finite element models of cylinderical implant, abutments and bone made by titanium or polyoxymethylene were simulated with the aid of Marc/Mentat software. Each model represented bone, implant and titanium or polyoxymethylene abutment. Model 1: Implant with 3 mm titanium abutment, Model 2: Implant with 2 mm polyoxymethylene resilient material abutment, Model 3: Implant with 3 mm polyoxymethylene resilient material abutment and Model 4: Implant with 4 mm polyoxymethylene resilient material abutment. A vertical load of 11 N was applied with a frequency of 2 cycles/sec. The stress distribution pattern and displacement at the junction of cortical bone and implant was recorded. RESULTS. When Model 2, 3 and 4 are compared with Model 1, they showed narrowing of stress distribution pattern in the cortical bone as the height of the polyoxymethylene resilient material abutment increases. Model 2, 3 and 4 showed slightly less but similar displacement when compared to Model 1. CONCLUSION. Within the limitation of this study, we conclude that introduction of different height resilient material abutment with different heights i.e. 2 mm, 3 mm and 4 mm polyoxymethylene, does not bring about significant change in stress distribution pattern and displacement as compared to 3 mm Ti abutment. Clinically, with the application of resilient material abutment there is no significant change in stress distribution around implant-bone interface.

Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections

  • Siadat, Hakimeh;Beyabanaki, Elaheh;Mousavi, Niloufar;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.271-277
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to evaluate the effect of implant connection design (external vs. internal) on the fit discrepancy and torque loss of zirconia and titanium abutments. MATERIALS AND METHODS. Two regular platform dental implants, one with external connection ($Br{\aa}nemark$, Nobel Biocare AB) and the other with internal connection (Noble Replace, Nobel Biocare AB), were selected. Seven titanium and seven customized zirconia abutments were used for each connection design. Measurements of geometry, marginal discrepancy, and rotational freedom were done using video measuring machine. To measure the torque loss, each abutment was torqued to 35 Ncm and then opened by means of a digital torque wrench. Data were analyzed with two-way ANOVA and t-test at ${\alpha}=0.05$ of significance. RESULTS. There were significant differences in the geometrical measurements and rotational freedom between abutments of two connection groups (P<.001). Also, the results showed significant differences between titanium abutments of internal and external connection implants in terms of rotational freedom (P<.001). Not only customized internal abutments but also customized external abutments did not have the exact geometry of prefabricated abutments (P<.001). However, neither connection type (P=.15) nor abutment material (P=.38) affected torque loss. CONCLUSION. Abutments with internal connection showed less rotational freedom. However, better marginal fit was observed in externally connected abutments. Also, customized abutments with either connection could not duplicate the exact geometry of their corresponding prefabricated abutment. However, neither abutment connection nor material affected torque loss values.

Pulsed Nd : YAG 레이저를 조사한 임플란트를 가토복강내에 이식시 주위조직에 미치는 영향 (SOFT TISSUE RESPONSE TO THE PULSED Nd : YAG LASED DENTAL IMPLANTS IN THE RABBIT ABDOMINAL WALL)

  • 전중현;이호용
    • 대한치과보철학회지
    • /
    • 제34권4호
    • /
    • pp.800-815
    • /
    • 1996
  • Pulsed Nd : YAG laser has been used to treat various soft tissue lesions. However, there have been warnings of using laser to treat peri-implantitis because the laser can alter the surface of implant and can rise its temperature so that it might be harmful to implant itself and its surrounding tissue. However, the study in vivo has not been done yet. The purpose of this study was to evaluate the biocompatibility to the pulsed Nd:YAG lased dental implant. 16 HA coated implants and 16 titanium plasma sprayed implants were used. They were divided 4 groups as unlased control, 0.3 watt, 1.0 watt and 2.0 watt lased groups after lasing. And they were implanted in the peritonial walls of 12 rabbits. The rabbits were sacrificed 6 weeks after implantation and the LM and EM specimems were made. 1. In the unlased implant group, both HA coated and titanium plasma sprayed implants were surrounded by fibroblasts and collagen fibers. No macrophages and inflammatory cells were seen. 2. In HA coated implants 0.3 watt, 1.0 watt lased group had a little inflammation, but in 2.0 watt lased group had scattered macrophages, a significantly larger number of chronic imflammatory cells were seen. 3. In titanium plasma sprayed implant 0.3 watt, 1.0 watt lased group had a little inflammation, but in 2.0 watt group had severe inflammation as in the conditions of HA coated group. 4. The inflammatory reaction of both lased HA coated and titanium plasma sprayed implant groups increased as the increase of the power of the laser.

  • PDF

Effect of different surface treatments on the shear bond strength of luting cements used with implant-supported prosthesis: An in vitro study

  • Degirmenci, Kubra;Saridag, Serkan
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권2호
    • /
    • pp.75-82
    • /
    • 2020
  • PURPOSE. The aim of this study was to investigate the shear bond strength of luting cements used with implant retained restorations on to titanium specimens after different surface treatments. MATERIALS AND METHODS. One hundred twenty disc shaped specimens were used. They were divided into three groups considering the surface treatments (no treatment, sandblasting, and oxygen plasma treatment). Water contact angle of specimens were determined. The specimens were further divided into four subgroups (n=10) according to applied cement types: polycarboxylate cement (Adhesor Carbofine-AC), temporary zinc oxide free cement (Temporary CementZOC), non eugenol provisional cement for implant retained prosthesis (Premier Implant Cement-PI), and non eugenol acrylic-urethane polymer based provisional cement for implant luting (Cem Implant Cement-CI). Shear bond strength values were evaluated. Two-way ANOVA test and Regression analysis were used to statistical analyze the results. RESULTS. Overall shear bond strength values of luting cements defined in sandblasting groups were considerably higher than other surfaces (P<.05). The cements can be ranked as AC > CI > PI > ZOC according to shear bond strength values for all surface treatment groups (P<.05). Water contact angles of surface treatments (control, sandblasting, and plasma treatment group) were 76.17° ± 3.99, 110.45° ± 1.41, and 73.80° ± 4.79, respectively. Regression analysis revealed that correlation between the contact angle of different surfaces and shear bond strength was not strong (P>.05). CONCLUSION. The retentive strength findings of all luting cements were higher in sandblasting and oxygen plasma groups than in control groups. Oxygen plasma treatment can improve the adhesion ability of titanium surfaces without any mechanical damage to titanium structure.

Three-Dimensional Pre-Bent Titanium Implant for Concomitant Orbital Floor and Medial Wall Fractures in an East Asian Population

  • Lee, Kyung Min;Park, Ji Ung;Kwon, Sung Tack;Kim, Suk Wha;Jeong, Eui Cheol
    • Archives of Plastic Surgery
    • /
    • 제41권5호
    • /
    • pp.480-485
    • /
    • 2014
  • Background The objective of this article is to evaluate clinical outcomes of combined orbital floor and medial wall fracture repair using a three-dimensional pre-bent titanium implant in an East Asian population. Methods Clinical and radiologic data were analyzed for 11 patients with concomitant orbital floor and medial wall fractures. A combined transcaruncular and inferior fornix approach with lateral canthotomy was used for the exposure of fractures. An appropriate three-dimensional preformed titanium implant was selected and inserted according to the characteristics of a given defect. Results Follow-up time ranged from 2 to 6 months (median, 4.07 months). All patients had a successful treatment outcome without any complications. Clinically significant enophthalmos was not observed after treatment. Conclusions Three-dimensional pre-bent titanium implants are appropriate for use in the East Asian population, with a high success rate of anatomic restoration of the orbital volume and prevention of enophthalmos in combined orbital floor and medial wall fracture cases.

Effects of various prophylactic procedures on titanium surfaces and biofilm formation

  • Di Salle, Anna;Spagnuolo, Gianrico;Conte, Raffaele;Procino, Alfredo;Peluso, Gianfranco;Rengo, Carlo
    • Journal of Periodontal and Implant Science
    • /
    • 제48권6호
    • /
    • pp.373-382
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the effects of various prophylactic treatments of titanium implants on bacterial biofilm formation, correlating surface modifications with the biofilms produced by Pseudomonas aeruginosa PAO1, Staphylococcus aureus, and bacteria isolated from saliva. Methods: Pure titanium disks were treated with various prophylactic procedures, and atomic force microscopy (AFM) was used to determine the degree to which surface roughness was modified. To evaluate antibiofilm activity, we used P. aeruginosa PAO1, S. aureus, and saliva-isolated Streptococcus spp., Bacteroides fragilis, and Staphylococcus epidermidis. Results: AFM showed that the surface roughness increased after using the air-polishing device and ultrasonic scaler, while a significant reduction was observed after using a curette or polishing with Detartrine ZTM (DZ) abrasive paste. In addition, we only observed a significant (P<0.01) reduction in biofilm formation on the DZ-treated implant surfaces. Conclusion: In this study, both AFM and antibiofilm analyses indicated that using DZ abrasive paste could be considered as the prophylactic procedure of choice for managing peri-implant lesions and for therapy-resistant cases of periodontitis.

질소이온주입에 따른 생체안전성 티타늄 임플란트의 마모특성 (Wear Properties of Biocompatible Ti Implant due to Nitrogen Ion Implantation)

  • 최종운;손선희;변응선;정용수
    • 한국안전학회지
    • /
    • 제14권4호
    • /
    • pp.126-134
    • /
    • 1999
  • In this study, plasma source ion implantation was used to improve the wear properties of biocompatible titanium implant. In order to observe the effect of ion energy and dose on wear property of titanium implant, pin-on-disk type wear tests in Hank's solution were carried out. The friction coefficient of ion implanted specimens were increased from 0.47 to 0.65 under high energy and ion dose conditions. As increasing ion energy and ion dose, the amount of wear was reduced.

  • PDF

레이저 처리후 임프란트 표면 변화에 관한 연구 (The Evaluation of the atomic composition and the surface roughness of Titanium Implants following Various Laser treatment with air-powder abrasive)

  • 김태정;임성빈;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제32권3호
    • /
    • pp.615-630
    • /
    • 2002
  • Various long-term studies have shown that titanium implants as abutments for different types of prostheses have become a predictable adjunct in the treatment of partially or fully edentulous patients. The continuous exposure of dental implants to the oral cavity with all its possible contaminants creates a problem. A lack of attachment, together with or caused by bacterial insult, may lead to peri-implantitis and eventual implant failure. Removal of plaque and calculus deposits from dental titanium implants with procedures and instruments originally made for cleaning natural teeth or roots may cause major alterations of the delicate titanium oxide layer. Therefore, the ultimate goal of a cleaning procedure should be to remove the contaminants and restore the elemental composition of the surface oxide without changing the surface topography and harming the surrounding tissues. Among many chemical and mechanical procedure, air-powder abrasive have been known to be most effective for cleaning and detoxification of implant surface. Most of published studies show that the dental laser may be useful in the treatment of pen-implantitis. $CO_2$ laser and Soft Diode laser were reported to kill bacteria of implant surface. The purpose of this study was to obtain clinical guide by application these laser to implant surface by means of Non-contact Surface profilometer and X-ray photoelectron spectroscopy(XPS) with respect to surface roughness and atomic composition. Experimental rough pure titanium cylinder models were fabricated. All of them was air-powder abraded for 1 minute and they were named control group. And then, the $CO_2$ laser treatment under dry, hydrogen peroxide and wet condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of the control models. The results were as follows: 1. Mean Surface roughness(Ra) of all experimental group was decreased than that of control group. But it wasn't statistically significant. 2. XPS analysis showed that in the all experimental group, titanium level were decreased, when compared with control group. 3. XPS analysis showed that the level of oxygen in the experimental group 1, 3($CO_2$ laser treatment under dry and wet condition) and 4(Soft Diode laser was used under toluidine blue O solution) were decreased, when compared with control group. 4. XPS analysis showed that the atomic composition of experimental group 2($CO_2$ laser treatment under hydrogen peroxide) was to be closest to that of control group than the other experimental group. From the result of this study, this may be concluded. Following air-powder abrasive treatment, the $CO_2$ laser in safe d-pulse mode and the Soft Diode laser used with photosensitizer would not change rough titanium surface roughness. Especially, $CO_2$ laser treatment under hydrogen peroxide gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.