Considerations and clinical appliances of various abutments in implant prostheses

임플란트 보철 치료에서 지대주 선택시 고려사항과 임상적 적용

  • Park, Sungwoo (Department of Prosthodontics, Gangnam Severance Dental Hospital) ;
  • Kim, Sunjai (Department of Prosthodontics, Gangnam Severance Dental Hospital) ;
  • Chang, Jae-Seung (Department of Prosthodontics, Gangnam Severance Dental Hospital)
  • 박성우 (강남세브란스 치과병원 치과보철과) ;
  • 김선재 (강남세브란스 치과병원 치과보철과) ;
  • 장재승 (강남세브란스 치과병원 치과보철과)
  • Received : 2016.01.22
  • Accepted : 2016.02.22
  • Published : 2016.03.01

Abstract

In the past, restoration of implant crown, ready-made abutment produced by implant manufacturer could only be used. Using straight, angled abutment, there was a limit in adaptation multiple implants. Recently, with the development of implant and CAD/CAM technology, CAD/CAM customized abutment use has become possible which is different from the past when restoration was possible with only prefabricated abutment. Not only it makes emergence profile possible which is similar to natural teeth, but also it makes insertion path possible on CAD in multiple implant restorations. However, on anterior teeth which dental esthetics is very important, another restorations which are formed with natural colored gingiva area could be required. Titanium-based zirconia prostheses which have titanium connection and zirconia structure from 1mm above fixture platform are alternative. Therefore, the purpose of this review is to analyze the characteristics, advantages and disadvantages of the abutment which is used in multiple implant restorations, and to choose right abutment when clinical trials.

Keywords

References

  1. Reeves WG. Restorative margin placement and periodontal health. J Prosthet Dent. 1991; 66: 733-736. https://doi.org/10.1016/0022-3913(91)90405-L
  2. Sumi T, Braian M, Shimada A, Shibata N, Takeshita K, Vandeweghe S, Coelho PG, Wennerberg A, Jimbo R. Characteristics of implant-CAD/CAM abutment connections of two different internal connection systems. J Oral Rehabil. 2012;39:391-8. https://doi.org/10.1111/j.1365-2842.2011.02273.x
  3. Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials:20(1999);1-25 https://doi.org/10.1016/S0142-9612(98)00010-6
  4. 장재승, 김선재. CAD/CAM으로 제작한 점막하 지르코니아 임플란트 보철 수복 증례; 대한치과보철학회지 52권 4호, 2014
  5. Carr A, Brunski J, Labishak J, et al. Preload comparison between as received and cast to implant cylinders. J Dent Res. 1993; 27(Suppl 1): 190-195.
  6. 김형섭. CAD/CAM 시스템을 이용한 custom abutment의 제작; 대한치과의사협회지 제50권 3 호, 2012
  7. Canullo L, Penarrocha D, Micarelli C, et al. Hard tissue response to argon plasma cleaning/sterilisation of customised titanium abutments versus 5-second steam cleaning: results of a 2-year post-loading followup from an explanatory randomised controlled trial in periodontally healthy patients. Eur J Oral Implantol. 2013; 6: 251-260.
  8. Sawase T, Wennerberg A, Hallgren C, et al. Chemical and topographical surface analysis of five different implant abutments. Clin Oral Implants Res. 2000; 11: 44-50. https://doi.org/10.1034/j.1600-0501.2000.011001044.x
  9. Ronald E. Jung, Irena Sailer. In vitro color changes of soft tissues caused by restorative materials. Int J Periodontics Res Dent 2004; 3: 251-257
  10. Leutert CR, Stawarczyk B, Truninger TC, Hammerle CH, Sailer I. Bending moments and types of failure of zirconia and titanium abutments with internal implant-abutment connections: a laboratory study. Int J Oral Maxillofac Implants. 2012; 27:505-12.
  11. Wood MR, Vermilyea SG; Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics. A review of selected dental literature on evidence-based treatment planning for dental implants: report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics. J Prosthet Dent 2004;92:447-62.