• Title/Summary/Keyword: time-switching

Search Result 1,904, Processing Time 0.024 seconds

An Optimal Determination of Subband-Frame Size and Mode Switching Level for Adaptive OFDM-TDD System (시분할 듀플렉싱 기반의 적응 직교 주파수 분할 다중 접속 시스템에서 부대역-프레임 크기와 모드 변환점의 최적 결정 기법)

  • Shin Kil-Ho;Lee Chang-Suk;Kim Jung-Gon;Kim Hyung-Myung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.6C
    • /
    • pp.512-522
    • /
    • 2005
  • In this paper, an optimal determination method of the subband-frame size and mode-switching level is proposed for adaptive OFDM-TDD systems in frequency-selective time-varying channels. The optimization problem considering frequency selectivity. user's mobility, and the signaling overhead caused by the mode change information is formulated in the maximum spectral efficiency sense satisfying the target BER. Assuming that subband-frame size is given, the mode-switching level is first optimized so that the spectral efficiency can be maximized satisfying the target BER. The subband-frame size among candidates is then determined, which maximizes the spectral efficiency. Simulation results show that the proposed scheme outperforms conventional schemes, in terms of the spectral efficiency and the BER.

Time Optimal Control of Nuclear Reactor with Constraint on Power Overshoot (Overshoot에 구속조건을 갖는 원자여의 시간최적제어)

  • 곽은호
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.12 no.4
    • /
    • pp.15-20
    • /
    • 1975
  • The power overshoot is rises in the output during the transient period when the output of nuclear reactor is increased from the initial state to the desired target state and certain amount of constraint on power level is of primary importance for safety control of nuclear reactor. Therefore, the maximum principle is applied to this process control in transfering its power from the initial state(no, co) to the final target state(2no, 2co or 1.5no, 1.5co), adjusting the reactivity so that its overshoot is limited within the allowable constraint required. In this case, the switching points, switching times, optimal lima and optimal control reactivity are calculated.

  • PDF

High Performance Liquid Chromatographic Analysis of a New Proton Pump Inhibitor KR60436 and Its Active Metabolite O-Demethyl-KR60436 in Rat Plasma Samples Using Column-Switching

  • Lee, Hyun-Mee;Lee, Hee-Yong;Choi, Joong-Kwon;Lee, Hye-Suk
    • Archives of Pharmacal Research
    • /
    • v.24 no.3
    • /
    • pp.207-210
    • /
    • 2001
  • A fully automated high performance liquid chromatography with column-switching was developed for the simultaneous determination of KR60436, a new reversible proton pump inhibitor, and its active metabolite O-Demethyl-KR60436 from rat plasma samples. Plasma sample (50$\mu$l) was directly introduced onto a Capcell Pak MF Ph-1 column ($10{\times}4$ mm I.D.) where primary separation was occurred to remove proteins and concentrate target Substances Using acetonitrile-Potassium Phosphate (PH 7, 0.1 M) (2 : 8, v/v). The drug molecules eluted from MF Ph-1 column were focused in an intermediate column ($10{\times}2$ I.D.) by the valve switching step. The substances enriched in intermediate column were eluted and separated on a Vydac 218MR53 column ($250{\times}3.2$ I.D.) using acetonitrilepotassium phosphate (pH 7, 0.02 M) (47:53, v/v) at a flow rate of 0.5 ml/min when the valve status was switched back to A position. The method showed excellent sensitivity (detection limit of 2 ng/ml) with small volume of samples ($50{\mu}$l), good precision and accuracy, and speed (total analysis time 24 min) without any loss in chromatographic efficiency. The response was linear ($r^2{\geq}0.797$) over the concentration range of 5-500 ng/ml.

  • PDF

The Operational Characteristics of High-speed Interrupter by Fault Types (고장 유형별 고속 인터럽터의 동작 특성)

  • Jeong, In-Sung;Choi, Hyo-Sang;Jung, Byung-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.278-283
    • /
    • 2013
  • With the increasing power demands, size of the fault current in electrical grids is steadily increasing, and it exceeds the breaking capacity of circuit breakers. To effectively cope with these problems, a high-speed interrupter was suggested. The high-speed interrupter provides fault current with a bypass to a fault current limiter in case of accidents and consequently, fault current can be restricted. In this study, behavioral characteristics of high-speed interrupter were analyzed by accident types occurred in a distribution system. When accidents occurred, a and b contact of the high-speed interrupter were turned-off and then, turned-on. Accordingly, fault current flowed to the circuit connected to a current limiting element, and the fault current limiter restricted fault current to within a half-cycle. Nevertheless, the behavior of the high-speed interrupter was slowed down by a switching surge. As a result, fault current was confirmed to be restricted not to within the anticipated half-cycle, but to after a half-cycle. Moreover, the behavioral characteristics of the high-speed interrupter changed not only by accident types, but by behaviors of R, S, and T phases. This was due to the errors in stroke lengths of the high-speed interrupters, which resulted in a slight time discrepancy among three interrupters. In addition, the switching behaviors of the b and a contact were confirmed not to have coincided due to the switching surge; b contact behaved first and a contact followed. because of this, accuracy of stroke length and switching surges through the solenoid suction increases may be necessary to resolve.

25 kW, 300 kHz High Step-Up Soft-Switching Converter for Next-Generation Fuel Cell Vehicles (차세대 연료전지 자동차용 25kW, 300kHz 고승압 소프트 스위칭 컨버터)

  • Kim, Sunju;Tran, Hai Ngoc;Kim, Jinyoung;Kieu, Huu-Phuc;Choi, Sewan;Park, Jun-Sung;Yoon, Hye-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.6
    • /
    • pp.404-410
    • /
    • 2021
  • This paper proposes a high step-up converter with zero-voltage transition (ZVT) cell for fuel cell electric vehicle. The proposed converter applies a ZVT cell to a dual floating output boost converter (DFOBC) so that not only the main switch but also the ZVT switch can achieve full-range soft switching. The current rating of the ZVT switch is 17% of the main switch. The proposed converter has high reliability in that no timing issue occurs. Therefore, online calculation is not required. The minimum turn-on time of the ZVT switch that guarantees soft switching at all loads and input/output voltage is obtained by analysis. In addition, the proposed DFOBC allows the use of a 650 V device even at 800 V output and has the advantage of being able to boost the voltage by 3.5 times with 0.56 duty. Planar coupled inductor with PCB winding was successfully implemented with the converter operated at 300 kHz. The 25 kW prototype achieves peak efficiency of 99% and power density of 63 kW/L.

AN INVESTIGATION OF THE KOREAN GENERAL INSURANCE INDUSTRY: EVIDENCE OF STRUCTURAL CHANGES AND IMPACT OF MACRO-ECONOMIC FACTORS ON LOSS RATIOS

  • Thompson, Ephraim Kwashie;Kim, So-Yeun
    • East Asian mathematical journal
    • /
    • v.38 no.5
    • /
    • pp.617-641
    • /
    • 2022
  • In this study, we first present a brief overview of the Korean general insurance market. We then explore the characteristics of the loss ratios of the Korean general insurance industry and apply Markov regime-switching methodology to model the loss ratios of these insurance companies by line of business based on changes in economic regimes. This study applies a number of confirmatory tests such as Zivot-Andrews test (2002), the Chow (1960) test and the Bai and Perron (1998) to confirm the presence of structural breaks in the time series of the loss ratios by line of business. Then, we employ Markov regime-switching methodology to model these loss ratios. We find empirical evidence that the loss ratios reported by insurance companies in Korea is characterized by two distinct regimes; a regime with high volatility and a regime with low volatility, except for vehicle insurance. Our analyses suggest that macro-economic conditions have significant explanatory effect on loss ratios but the direction of effect differs based on the line of business and the regime. Unlike previous studies that have applied linear regressions or divided the samples into different periods and then apply linear regressions to model loss ratios, we argue for the application of Markov regime-switching methodology, which are able to automatically distinguish the different regimes that may be associated with the movements of loss ratios based on differing economic conditions and regulatory upheavals. This study provides a more in depth understanding of loss ratios in the general insurance industry and will be of value to insurance practitioners in modelling the loss ratios associated with their businesses to aid in their decision making. The results may also provide a basis for further studies in other markets apart from Korea as well as for shaping policy decisions related to loss ratios.

A Constant Time Algorithm for Deterministic Finite Automata Problem on a Reconfigurable Mesh (재구성 가능한 메쉬에서 결정적 유한 자동장치 문제에 대한 상수시간 알고리즘)

  • Kim, Yeong-Hak
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.11
    • /
    • pp.2946-2953
    • /
    • 1999
  • Finite automation is a mathematical model to represent a system with discrete inputs and outputs. Finite automata are a useful tool for solving problems such as text editor, lexical analyzer, and switching circuit. In this paper, given a deterministic finite automaton of an input string of length n and m states, we propose a constant time parallel algorithm that represents the transition states of finite automata and determines the acceptance of an input string on a reconfigurable mesh of size [nm/2]$\times$2m.

  • PDF

Fault Tolerant Control with Variable Time Weight (가변시간비중을 갖는 내고장성 제어)

  • Hee Gyoo Lee;Zeungnam Bien
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.29B no.4
    • /
    • pp.22-30
    • /
    • 1992
  • A redundant control scheme which can maintain its tracking capability in the case of a controller failure is proposed for the industrial applications which need high reliability with fault-tolerance. It consists of two identical controllers and a switching mechanism which includes failure detection and reconfiguration algorithm. The new detection method against controller failure using fuzzy logic enables the detection of controller failures without failure assumptions through the instability of the failed controller. The failed controller is smoothly removed from the control loop by reducing time weight of the failed controller.

  • PDF

STABILIZATION OF SWITCHED SYSTEMS WITH UNCONTROLLABLE SUBSYSTEMS

  • Zhu, Yanli;Sun, Yuangong
    • Journal of applied mathematics & informatics
    • /
    • v.31 no.5_6
    • /
    • pp.895-906
    • /
    • 2013
  • In this paper, we study the stabilization problem of switched systems with both controllable and uncontrollable subsystems. By using an average dwell time approach, we first establish a sufficient condition such that the switched system is exponentially stabilizable under appropriate switching signals. We also extend this result to the switched system with nonlinear impulse effects and disturbances. Numerical examples are given to illustrate the theoretical results.

Digital Control of Phase-Shifted Full-Bridge PWM Converter

  • Lim, Jeong-Gyu;Chung, Se-Kyo
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.201-209
    • /
    • 2008
  • This paper presents the modeling and design of a digital controller for a phase-shifted full-bridge converter (PSFBC) in a discrete-time domain. The discretized PSFBC model is first derived and then analyzed considering the sampling effect and the system parameters. Based on this model, the digital controller is directly designed in a discrete-time domain. The simulation and experimental results are provided to show the validity of the proposed modeling and controller design.