• 제목/요약/키워드: time-interval signal

검색결과 302건 처리시간 0.028초

Multivariate EWMA Control Chart for Means of Multiple Quality Variableswith Two Sampling Intervals

  • Chang, Duk-Joon;Heo, Sunyeong
    • 통합자연과학논문집
    • /
    • 제5권3호
    • /
    • pp.151-156
    • /
    • 2012
  • Because of the equivalence between control chart procedures and hypothesis testing, we propose to use likelihood ratio test (LRT) statistic $Z_i^2$ as the multivariate control statistic for simultaneous monitoring means of the multivariate normal process. Properties and comparisons of the proposed control charts are explored and conducted for matched fixed sampling interval (FSI) and variable sampling interval (VSI) with two sampling interval charts. The result of numerical comparisons shows that EWMA chart with two sampling interval procedure is more efficient than the corresponding FSI chart for small or moderate changes. When large shift of the process has occurred, we also found that Shewhart chart is more efficient than EWMA chart.

호흡-바이오피드백 앱 개발을 위한 PPG기반의 호흡 추정 알고리즘 (Breathing Information Extraction Algorithm from PPG Signal for the Development of Respiratory Biofeedback App)

  • 최병훈
    • 전기학회논문지
    • /
    • 제67권6호
    • /
    • pp.794-798
    • /
    • 2018
  • There is a growing need for a care system that can continuously monitor, manage and effectively relieve stress for modern people. In recent years, mobile healthcare devices capable of measuring heart rate have become popular, and many stress monitoring techniques using heart rate variability analysis have been actively proposed and commercialized. In addition, respiratory biofeedback methods are used to provide stress relieving services in environments using mobile healthcare devices. In this case, breathing information should be measured well to assess whether the user is doing well in biofeedback training. In this study, we extracted the heart beat interval signal from the PPG and used the oscillator based notch filter based on the IIR band pass filter to track the strongest frequency in the heart beat interval signal. The respiration signal was then estimated by filtering the heart beat interval signal with this frequency as the center frequency. Experimental results showed that the number of breathing could be measured accurately when the subject was guided to take a deep breath. Also, in the timeing measurement of inspiration and expiration, a time delay of about 1 second occurred. It is expected that this will provide a respiratory biofeedback service that can assess whether or not breathing exercise are performed well.

거리 측정 시스템의 정밀도 향상을 위한 카운터 회로의 설계 (Design of Counter Circuit for Improving Precision in Distance Measuring System)

  • 최진호
    • 한국정보통신학회논문지
    • /
    • 제24권7호
    • /
    • pp.885-890
    • /
    • 2020
  • 거리측정 시스템에서 사용되는 시간-디지털 변환회로는 시작신호와 멈춤신호 사이의 시간 간격을 이용하여 거리를 측정한다. 응답속도를 고려한 시간 간격은 일반적으로 카운터 회로를 이용하여 디지털 정보로 변환한다. 그러므로 정밀도 향상을 위해서는 높은 주파수의 클록 신호가 요구되며, 미세 거리의 측정을 위해서도 높은 주파수의 클록 신호가 필요하다. 본 논문에서는 동일한 주파수를 사용하면서도 거리 측정의 정밀도를 높이기 위한 카운터 회로를 설계하였다. 회로의 설계는 0.18㎛ CMOS 공정을 이용하였으며, 설계된 회로의 동작은 HSPICE 시뮬레이션을 통하여 확인하였다. 시뮬레이션 결과 일반적인 카운터 회로를 사용한 경우에 비해 4배의 향상된 정밀도를 얻을 수 있었다.

심자도 신호획득을 위한 실시간 256-채널 12-bit 1ks/s 하드웨어 (Real-time 256-channel 12-bit 1ks/s Hardware for MCG Signal Acquisition)

  • 유재택
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권11호
    • /
    • pp.643-649
    • /
    • 2005
  • A heart diagnosis system adopts Superconducting Quantum Interface Device(SQUD) sensors for precise MCG(MagnetoCardioGram) signal acquisitions. Such system needs to deal with hundreds of sensors, requiring fast signal sampling md precise analog-to-digital conversions(ADC). Our development of hardware board, processing 64-channel 12-bit in 1 ks/s speed, is built by using 8-channel ADC chips, 8-bit microprocessors, SPI interfaces, and specially designed parallel data transfers between microprocessors to meet the 1ks/s, i.e. 1 mili-second sampling interval. We extend the design into 256-channel hardware and analyze the speed .using the measured data from the 64-channel hardware. Since our design exploits full parallel processing, Assembly level coding, and NOP(No Operation) instruction for timing control, the design provides expandability and lowest system timing margin. Our result concludes that the data collection with 256-channel analog input signals can be done in 201.5us time-interval which is much shorter than the required 1 mili-second period.

A New Prediction Method for Scintillation Expression

  • Chutchavong, Vanvisa;Nakasuwan, Jintana;Sangaroon, Ornlarp;Jenchitrapongvej, Kanok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2082-2086
    • /
    • 2003
  • This paper presents the analysis of satellite received signal by focus on the new prediction method for amplitude scintillation expression. A predict method based in the relationship of standard deviation values and the peak to peak values of amplitude scintillation in various of time period and various of sampling rate of signal variation. The principal techniques finding, the proper sampling rate and time interval, for the best expression method. The experiment has been performed in Bangkok of Thailand, at King Mongkut's Institute of Technology, Ladkrabang, data collected in C-Band and Ku-Band on high elevation angles. The result of analysis shows the relationship between two methods is given by ${\sigma}_x={\alpha}(P-P)+{\beta}$. The value of ${\alpha}$ depends on sampling rate by closely with three-minute maximum time interval.

  • PDF

송신 신호의 도달 시간차(TDOA)를 이용한 위치 측정 시스템의 구현 (Position Measuring System Design using Time Difference of Arrival)

  • 김동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.394-397
    • /
    • 2001
  • There are several methods of measuring position. For example GPS, AOA, TDOA and using radio camera. In this Paper I used TDOA method in position measuring system. TDOA method uses arrival time difference. In position measuring system, three transfers which is placed in different position transfer signal to receiver in fixed time interval and receiver records arrival time of signal. Because receiver knows idle signal's arrival time, receiver can calculate the difference of the signal's arrival time between idle and real. When we obtain time difference we can know the receiver position by Newton Raphson method.

  • PDF

Intelligent Traffic Light using Fuzzy Neural Network

  • Park, Myeong-Bok;You-Sik, Hong
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제3권1호
    • /
    • pp.66-71
    • /
    • 2003
  • In the past, when there were few vehicles on the road, the T.O.D.(Time of Day) traffic signal worked very well. The T.O.D. signal operates on a preset signal cycling which cycles on the basis of the average number of average passenger cars in the memory device of an electric signal unit. Today, with increasing traffic and congested roads, the conventional traffic light creates startup-delay time and end lag time so that thirty to forty-five percent efficiency in traffic handling is lost, as well as adding to fuel costs. To solve this problem, this paper proposes a new concept of optimal green time algorithm, which reduces average vehicle waiting time while improving average vehicle speed using fuzzy rules and neural networks. Through computer simulation, this method has been proven to be much more efficient than fixed time interval signals. Fuzzy Neural Network will consistanly improve average waiting time, vehicle speed, and fuel consumption.

국소 극대-극소점 간의 간격정보를 이용한 시간영역에서의 음성인식을 위한 파라미터 추출 방법 (A Time-Domain Parameter Extraction Method for Speech Recognition using the Local Peak-to-Peak Interval Information)

  • 임재열;김형일;안수길
    • 전자공학회논문지B
    • /
    • 제31B권2호
    • /
    • pp.28-34
    • /
    • 1994
  • In this paper, a new time-domain parameter extraction method for speech recognition is proposed. The suggested emthod is based on the fact that the local peak-to-peak interval, i.e., the interval between maxima and minima of speech waveform is closely related to the frequency component of the speech signal. The parameterization is achieved by a sort of filter bank technique in the time domain. To test the proposed parameter extraction emthod, an isolated word recognizer based on Vector Quantization and Hidden Markov Model was constructed. As a test material, 22 words spoken by ten males were used and the recognition rate of 92.9% was obtained. This result leads to the conclusion that the new parameter extraction method can be used for speech recognition system. Since the proposed method is processed in the time domain, the real-time parameter extraction can be implemented in the class of personal computer equipped onlu with an A/D converter without any DSP board.

  • PDF

퍼지 트랜지션 시간 페트리 네트의 이산 사건 시스템에 응용 (Application of Fuzzy Transition Timed Petri Net for Discrete Event Dynamic Systems)

  • 모영승;김진권;김정철;탁상아;황형수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.364-364
    • /
    • 2000
  • Timed Petri Net(TPN) is one of methods to model and to analyze Discrete Event Dynamic Systems(DEDSs) with real time values. It has two time values, earliest firing time ($\alpha$$_{i}$) and latest firing time ($\beta$$_{I}$) for the each transition. A transition of TPN is fired at arbitrary time of time interval ($\alpha$$_{I}$, $\beta$$_{i}$). Uncertainty of firing time gives difficulty to analyze and estimate a modeled system. In this paper, we proposed the Fuzzy Transition Timed Petri Net(FTTPN) with fuzzy theory to determine the optimal transition time (${\gamma}$$_{i}$). The transition firing time (${\gamma}$$_{i}$) of FTTPN is determined from fuzzy controller which is modeled with information of state transition. Each of the traffic signal controllers are modeled using the proposed method and timed petri net. And its Performance is evaluated by simulation of traffic signal controller. controller.

  • PDF

Design of the Variable Sampling Rates X-chart with Average Time to Signal Adjusted by the Sampling Cost

  • Park, Chang-Soon;Song, Moon-Sup
    • Journal of the Korean Statistical Society
    • /
    • 제26권2호
    • /
    • pp.181-198
    • /
    • 1997
  • The variable sampling rates scheme is proposed by taking random sample size and sampling interval during the process. The performance of the scheme is measured in terms of the average time to signal adjusted by teh sampling cost when the process is out of control. This measurement evaluates the effectiveness of the scheme in terms of the cost incurred due to nonconformation as well as sampling. The variable sampling rates scheme is shown to be effective especially for small and moderate shifts of the mean when compared to the standard scheme.

  • PDF