• Title/Summary/Keyword: threshold effect

Search Result 1,518, Processing Time 0.029 seconds

A STUDY ON THE HEAT GENERATION OF BONE DRILLING BURS ACCORDING TO IRRIGATION DURING IMPLANTATION OF DENIAL IMPLANT (치과 임플랜트 식립시 관주에 따른 골 천공 기구의 열 발생에 관한 연구)

  • Moon, Eun-Soo;Lim, Heun-Song;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.433-453
    • /
    • 1999
  • There are a lot of elements affecting the success of implant prosthesis. The quality of surgical procedure is considered as one of the key factors. To avoid the excess heat generation is an important element of successful osseointegration and it can be achieved by using a gentle surgical technique with a sharp instrument in bone drilling. This study was performed to measure and analyze comparatively the heat transmitted to sur-rounding bone at a distance of 0.5mm from the periphery of the drill hole in each drilling stage. The results were as follows. In standard system, the temperature of surrounding bone tissue ranged from $29.2^{\circ}C\;to\;48.3^{\circ}C$ with irrigation and from $34.6^{\circ}C\;to\;84.3^{\circ}C$ without irrigation. And in wide system, the temperature of surrounding bone tissue ranged from $29.5^{\circ}C\;to\;52.5^{\circ}C$ with irrigation and from $34.8^{\circ}C\;to\;87.8^{\circ}C$ without irrigation. And the temperature ranges exceeded the threshold without irrigation, while showing less than the threshold by the cooling effect of irrigation. In comparing standard system with wide system, although there was no significant difference, ${\phi}4.3mm$ pilot and ${\phi}4.3mm$ twist drill of wide system showed high value and wide system showed slightly high elevation of temperature in all depth in fixture installation. In the finite element analysis, the calculated value by the Fourier's cooling law were applied to the bone drilling surface. And through analysis using different irrigation temperatures at $28^{\circ}C,\;15^{\circ}C\;and\;5^{\circ}C$, and according to the time. The result was that the cooling water at least below $15^{\circ}C$ was required to maintain the temperature of surrounding bone less than threshold in bone drilling, the cooling water below $5^{\circ}C$ was required to gain more sufficient cooling effect, and cooling over 5 seconds was needed after bone drilling for sufficient effect.

  • PDF

Optically Controlled Silicon MESFET Modeling Considering Diffusion Process

  • Chattopadhyay, S.N.;Motoyama, N.;Rudra, A.;Sharma, A.;Sriram, S.;Overton, C.B.;Pandey, P.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.3
    • /
    • pp.196-208
    • /
    • 2007
  • An analytical model is proposed for an optically controlled Metal Semiconductor Field Effect Transistor (MESFET), known as Optical Field Effect Transistor (OPFET) considering the diffusion fabrication process. The electrical parameters such as threshold voltage, drain-source current, gate capacitances and switching response have been determined for the dark and various illuminated conditions. The Photovoltaic effect due to photogenerated carriers under illumination is shown to modulate the channel cross-section, which in turn significantly changes the threshold voltage, drainsource current, the gate capacitances and the device switching speed. The threshold voltage $V_T$ is reduced under optical illumination condition, which leads the device to change the device property from enhancement mode to depletion mode depending on photon impurity flux density. The resulting I-V characteristics show that the drain-source current IDS for different gate-source voltage $V_{gs}$ is significantly increased with optical illumination for photon flux densities of ${\Phi}=10^{15}\;and\;10^{17}/cm^2s$ compared to the dark condition. Further more, the drain-source current as a function of drain-source voltage $V_{DS}$ is evaluated to find the I-V characteristics for various pinch-off voltages $V_P$ for optimization of impurity flux density $Q_{Diff}$ by diffusion process. The resulting I-V characteristics also show that the diffusion process introduces less process-induced damage compared to ion implantation, which suffers from current reduction due to a large number of defects introduced by the ion implantation process. Further the results show significant increase in gate-source capacitance $C_{gs}$ and gate-drain capacitance $C_{gd}$ for optical illuminations, where the photo-induced voltage has a significant role on gate capacitances. The switching time ${\tau}$ of the OPFET device is computed for dark and illumination conditions. The switching time ${\tau}$ is greatly reduced by optical illumination and is also a function of device active layer thickness and corresponding impurity flux density $Q_{Diff}$. Thus it is shown that the diffusion process shows great potential for improvement of optoelectronic devices in quantum efficiency and other performance areas.

The effect of applying a head-weight device on cervical angle and pain of neck muscles

  • Kim, Jin-Hong;Kim, Jong-Gun;Do, Kwang-Sun;Yim, Jongeun
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.2
    • /
    • pp.101-105
    • /
    • 2016
  • Objective: The purpose of this study was to measure the change in pain threshold of levator scapular muscle, carniovertebral angle, and head position angle when applying a head-weight device on healthy adult. Design: Cross-sectional study. Methods: This study was conducted with 21 healthy adult male and female who voluntarily agreed to participate in this study after being informed of the purpose and method of this study. After measuring the cervical angle and pain threshold of levator scapular muscle, subject was instructed to walk for 5 minutes on a treadmill at a speed of less than 5 km/h while wearing after wearing head-weight device of 0.5 kg. Then, cervical spine angle and pain threshold of levator scapula muscle were re-measured. Measurement of cervical spine angle was conducted with photo by using the Bluebeam Revu software and the pain pressure thresholds (PPTs) were measured using an electronic algometer over potential trigger points on the body. Results: The results cervical angle showed a significant change, from $49.62^{\circ}$ to $52.10^{\circ}$ (p<0.05). PPT showed a significant change, from 30.71 to 36.89 (p<0.05). Conclusions: These findings suggest that applying head-weight device has a positive influence on increasing cervical angle and reducing pain when applied as a therapeutic intervention method of forward head posture.

Effect of Environmental Factors on the Determination of the Ecotoxicological Threshold Concentration of Cu in Soil Pore Water through Biotic Ligand Model and Species Sensitivity Distribution (Biotic ligand model과 종 민감도 분포를 이용한 토양 공극수 내 Cu의 생태독성학적 허용농도 결정에 미치는 환경인자의 영향)

  • Yu, Gihyeon;An, Jinsung;Jeong, Buyun;Nam, Kyoungphile
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.1
    • /
    • pp.49-58
    • /
    • 2017
  • Biotic ligand model (BLM) and species sensitivity distribution (SSD) were used to determine the site-specific Cu threshold concentration (5% hazardous concentration; HC5) in soil pore water. Model parameters for Cu-BLM were collected for six plants, one collembola, and two earthworms from published literatures. Half maximal effective concentration ($EC_{50}\{Cu^{2+}\}$), expressed as $Cu^{2+}$ activity, was calculated based on activities of major cations and the collected Cu-BLM parameters. The $EC_{50}\{Cu^{2+}\}$ varied from 2 nM to $251{\mu}M$ according to the variation in environmental factors of soil pore water (pH, major cation/anion concentrations) and the type of species. Hazardous activity for 5% (HA5) and HC5 calculated from SSD varied from 0.076 to $0.4{\mu}g/L$ and 0.4 to $83.4{\mu}g/L$, respectively. HA5 and HC5 significantly decreased with the increase in pH in the region with pH less than 7 due to the decrease in competition with $H^+$ and $Cu^{2+}$. In the region with pH more than 7, HC5 increased with the increase in pH due to the formation of complexes of Cu with inorganic ligands. In the presence of dissolved organic carbon (DOC), Cu and DOC form a complex, which decreases $Cu^{2+}$ activity in soil pore water, resulting in up to 292-fold increase in HC5 from 0.48 to $140{\mu}g/L$.

Analysis of the Drain Current in Nonuniformly Doped Channel(NUDC) MOSFET's due to Pocket Ion Implantation (포켓 이온주입으로 비균질 채널도핑을 갖는 MOSFET소자의 드레인 전류 해석)

  • Koo, Hoe-Woo;Park, Joo-Seog;Lee, Kie-Young
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.9
    • /
    • pp.21-30
    • /
    • 1999
  • Halo pocket implantation in MOSFETs, which is known to be an efficient method to provent the punchthrough and threshold voltage roll-off phenomena, decreases the drain current of MOSFET devices. Although the decrease of the drain current in halo structure MOSFET is usually explained in terms of the increase of the threshold voltage, more decrease in the drain current than is predicted by the increased threshold voltage has experimentally been observed. In this work, the effect of halo doping profile on the drain current degradation is investigated in terms of the field distribution along the channel. Effective mobility model of the halo MOSFETs due to pocket implantation is presented and the degradation of the mobility is shown to be effective in the further decrease of the drain current. Present model is shown to be in good agreement with experimental results.

  • PDF

The Effect of Fatigue Fracture in shot peening Marine structural steel at stress ratio (쇼트피닝 가공된 해양구조용강의 피로파괴에 미치는 응력비의 영향)

  • Park, Kyoung-Dong;Han, Kun-Mo;Jin, Young-Beom
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.138-144
    • /
    • 2003
  • Rencentely, the request for the light weight is more incresed in the area of industrial environment and machinery and consistent effort is needed to accomplish high strength of material for the direction of light weight. we got the following characteristic from crack growth test carried out in the range of stress ration of 0.1, 0.3 and 0.6 by means of opening mode displacement. At the content stress ratio, the threshold stress intensity factor crack range ${\Delta}K_{th}$in the early stage of fatigue crack growth (Region I) and dtress intensity factor range ${\Delta}K$ in the stable of fatigue crack growth (Region II) with an increase in ${\Delta}K$. Fatigue life shows more improvement in the Shot-peened material than in the Un-peening material. And compressive residual stress of surface on the Shot peening processed operate resistance force of fatigue. So we can obtain fallowings. (1) The fatigue crack growth rate on stage II is conspicuous with the size of compressive residual stress and is depend on Paris equation. (2) Although the maxium compressive residual stress is deeply and widely formed from surface, fatigue life does not improve than when maxium compressive residual stress is formed in surface. (3) The threshold stress intensity factor range is increased with increasing compressive residual stress.

  • PDF

The Changes in the Electrical Stimulation Induced Pain Threshold and Skin Temperatures According to Methods of Cold Application (냉(cold)적용 방법에 따른 동통 역치 및 피부 온도의 변화)

  • Kim, Suhn-Yeop;Ryu, I-Hwa;Park, Eun-Haw;Bae, Hye-Jin
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.3
    • /
    • pp.25-34
    • /
    • 1996
  • The purpose of this experimental study was conducted to examine the most effective modality between two methods of cold application(ice pack and cold spray), the most effective length of time for the application and the continuing effect after each type of cold application. Sixty students were assigned randomly to each of two cold application methods; (a) ice pack, (2) cold spray. Each methods was applied to the posterior surface of right forearm with subject in the sitting position. Skin temperature and the electrical stimulation induced pain threshold were measured before each application and every five degree ($^{\circ}C$) decline point after ice pack application. They were also measured point of minimum skin temperature after cold spray application. The results of this study are as follows; 1. Skin temperatures according to the cold spray application decreased to a range of $4.2^{\circ}C{\sim}9.2^{\circ}C$(male, p<0.001), $3.6^{\circ}C{\sim}7.6^{\circ}C$(female, p<0.001). 2. Pain threshold according to the cold spray application increased to a range of $0.6mA{\sim}1.9mA$(male, p<0.01), $1.2mA{\sim}3.86mA$(female, p>0.05).

  • PDF

N-methyl-D-aspartate (NMDA) and Non-NMDA Receptors are Involved in the Production and Maintenance of Nociceptive Responses by Intraplantar Injection of Bee Venom and Melittin in the Rat

  • Kim, Jae-Hwa;Shin, Hong-Kee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.9 no.3
    • /
    • pp.179-186
    • /
    • 2005
  • Whole bee venom (WBV) and its major component, melittin, have been reported to induce long-lasting spontaneous flinchings and hyperalgesia. The current study was designed to elucidate the peripheral and spinal mechanisms of N-methyl-D-aspartate (NMDA) and non-NMDA receptors by which intraplantar (i.pl.) injection of WBV and melittin induced nociceptive responses. Changes in mechanical threshold and flinching behaviors were measured after the injection of WBV (0.04 mg or 0.1 mg/paw) and melittin (0.02 mg or 0.05 mg/paw) into the mid-plantar area of a rat hindpaw. MK-801 and CNQX (6-cyano-7-nitroquinoxaline-2,3-dione disodium) were administered intrathecally (i.t. $10{\mu}g$) or i.pl.($15{\mu}g$) 15 min before or i.t. 60 min after i.pl. WBV and melittin injection. Intrathecal pre- and postadministration of MK-801 and CNQX significantly attenuated the ability of high dose WBV and melittin to reduce paw withdrawal threshold (PWT). In the rat injected with low dose, but not high dose, of WBV and melittin, i.pl. injection of MK-801 effectively suppressed the decrease of PWTs only at the later time-points, but the inhibitory effect of CNQX (i.pl.) was significant at all time-point after the injection of low dose melittin. High dose WBV- and melittin-induced spontaneous flinchings were significantly suppressed by i.t. administration of MK-801 and CNQX, and low dose WBV- and melittin-induced flinchings were significantly reduced only by intraplantarly administered CNQX, but not by MK-801. These experimental flinchings suggest that spinal, and partial peripheral mechanisms of NMDA and non-NMDA receptors are involved in the development and maintenance of WBV- and melittin-induced nociceptive responses.

Fabrication of deflector integrated laser diodes and light deflection (광 편향기 집적 레이저 다이오드의 제작 및 광의 편향)

  • 김강호;권오기;김종회;김현수;심은덕;오광룡;김석원
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.2
    • /
    • pp.171-176
    • /
    • 2004
  • A light deflector integrated laser diode(LD) was fabricated and the characteristics of LD and ourput beam deflection as a function of deflector injection current were measured. To integrate the deflector with LD, a passive waveguide was integrated with the LD and a triangular-type light deflector was fabricated on the upper clad of the passive waveguide section. Light deflection from the fabricated light deflector is controlled by the effective refractive index variation induced by carrier injection. To characterize the effect of the deflector injection current, threshold current, slope efficiency, and output beam spectrum were measured as a function of deflector injection current. From these measured data, the increment in the threshold current and the decrement of the slope efficiency were observed. However, the output beam spectrum was not affected by the deflector. The Beam Propagation Method(BPM) was used to simulate the proposed device and the light deflection was measured by the far-field pattern of the output beam as a function of the deflector injection current. In the fabricated deflector integrated LD, the deflection angle of 1.9$^{\circ}$ at the injection current of 15 ㎃ was obtained.

The Effects of Related Factors on Quality of Life for the Elderly (노인의 삶의 질 관련요인 분석)

  • Kang, Lee-Ju
    • Journal of Families and Better Life
    • /
    • v.26 no.5
    • /
    • pp.129-142
    • /
    • 2008
  • This study examines how economic and psychological characteristics affect the quality of life (QoL) of elderly individuals age 60 and older, who live in the Seoul-metropolitan area. Relationships among socio-demographic status, economic conditions, psychological characteristics, family life, health status, and QoL are examined by t-test and ANOVA(Duncan's test as post hoc multiple comparisons), and the multiple regression analysis is used to estimate QoL determinants in the elderly. The major findings of the study are as follows. First, younger age, higher education levels, better health status, harmonious family relations, higher levels of household income, lower levels of loneliness, and higher self-esteems are related to higher QoL levels. Second, the impacts of factors on QoL are differentiated according to tercile groups that divide monthly allowance of respondents into three categories: below normal (threshold amount below 21MW), near normal (threshold amount between 21MW and 35MW), and above normal (threshold amount above 35MW). For each tercile group, poor health status or higher loneliness have negative effects on QoL, while harmonious family relationship has a positive effect. For the below-normal group, years of education or self-esteem have positive effects, while age or retirement status have negative effects when controlling for other factors. For the near-normal group, being married, or perceived financial insecurity create lower QoL levels, while higher self-esteem increases QoL levels. For the above-normal group, being widowed, employed, or retired have positive effects on QoL, when controlling for other variables. Third, even among elderly with high allowances, the effects of health status and family relationship are significant determinants that explain QoL levels. This result suggests that, for te elderly, poor health status and poor family relationships severely decrease QoL in later life, regardless of economic condition.