Application of the Robust Control Theory to the Dynamic Voltage Restorer

  • Y. Chun;Kim, J.;J. Jeon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.38.2-38
    • /
    • 2001
  • Recent trend of increasing automated factories needs supply of high quality power from the utilities. Among the items of the power quality, voltage sag can be compensated by Dynamic Voltage Restorer(DVR). The key feature of the DVR is high response with less transient period to recover from the voltage sag due to the lightning or line-to-ground faults. In this paper we report that H controller is very premising for the practical application to the controller of DVR. Experiment al results shown in this paper was obtained by applying the control algorithm to 20 kVA DVR system. The experimental set consist s of IGBT - based three phase inverter and the TMS320C32- 60 DSP used for main processor of the control board. T$\infty$ simulate the 50% voltage ...

  • PDF

Fault Diagnosis for 3-Phase Diode Rectifier using Harmonic Ripples of DC Link Voltage (직류단 전압의 고조파 맥동 검출을 이용한 3상 다이오드 정류기의 고장 진단)

  • Park, Je-Wook;Baek, Seong-Won;Kim, Jang-Mok;Lee, Dong-Choon;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.457-465
    • /
    • 2011
  • The fault analysis and detecting algorithm for a 3 phase diode rectifier is proposed. The 3 phase dioderectifier is used for the AC power rectifier of the PWM inverter. The input power or diode faults cause theripples of the DC voltage, degradation of the control performance and life shortening of the DC link capacitor.In this paper, the ripple of the DC voltage is mathematically analyzed for the earth fault of input power andopen circuit fault of the diode, respectively. The fault detection and type of fault can be obtained by comparingthe average DC voltage and the instant DC voltage which is sampled with 6 times of grid frequency. Theproposed method can be easily applicable and doesn't require additional circuit. The experimental and simulationresults are presented to verify the validity of the proposed method.

Harmonic and Torque Ripple Reduction of Electric Propulsion System using 12-Pulse Diode Rectifier by Auxiliary Supply (보조 전원을 이용한 12 펄스 다이오드 정류기를 사용하는 추진시스템의 고조파 및 토크 리플 저감)

  • Kim, Jong-Su;Seo, Dong-Hoan;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.1
    • /
    • pp.66-70
    • /
    • 2013
  • The input current of three phase rectifier which is mainly used in the propulsion system of the electric propulsion ship includes a variety of low order harmonics. To reduce these harmonics, the power conversion system, used in the large vessels which high power is required, is currently used the rectifiers of 12-pulse output, but it still has a problem that occurs $12{\pm}1$ harmonics. Also, in the case of the direct torque control technique which is widely used for the speed and torque control, the torque ripple is severe and the input current of motor has greatly included harmonics by the switching of the inverter. In order to reduce harmonics and improve the performance of torque control, this paper presents that the auxiliary supply assisted into the 12-pulse rectifier of the electric propulsion system using direct torque control technique. We confirm the validity of the proposed method through the simulation under the environment of a real vessel system.

Design of the Robust Active Power Filter under the Unbalanced and Distorted Source Voltages in Three-phase Four-wire Systems (전원전압의 불평형 및 왜곡에 강인한 3상 4선식 전력용 능동 필터의 설계)

  • Min Joon-Ki;Kim HyoSung;Choi Jaeho;Kim Kyung-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.420-429
    • /
    • 2004
  • This paper proposes a novel current control strategy on active power filters using PQR instantaneous power theory which can compensate the line current harmonics and the neutral line current under the unbalanced and/or distorted source conditions in three-phase four-wire systems. The characteristics of the inverter ac filters are analyzed and a novel digital controller are proposed to overcome the inherent time delay problem in digital controllers with designed control gain in this paper. The proposed current control method is based on a sinusoidal PWM for fully-digital implementation compared with a conventional hysteresis PWM. PSiM simulation results verify the good performance of the proposed current control strategy on shunt type APFs.

A Study on the Implementation of Inverter Systems for Regenerated Power Control (회생전력 제어용 인버터 시스템의 구현에 관한 연구)

  • 金 敬 源;徐 永 泯;洪 淳 瓚
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.205-213
    • /
    • 2002
  • This paper deals with the implementation of three-phase VSI systems which can control the power regenerated from DC bus line to AC supply. The overall system consists of the line-to-line voltage and line current sensors, an actual power calculator using d-q transformation method, a complex power controller with PI control scheme, a gating signal generator for modified q-conduction mode, a DPLL for frequency followup, and Power circuits. Control board is constructed by using a 32-bit DSP TMS32C32, two EFLDs , six ADCs, and a DAC. To verify the performance of the proposed system, we designed and constructed the propotype with the power rating of 5kVA at AC 220V. Experimental results show that the regenerated active power is well controlled to its command vague and the regenerated reactive power still remained at nearly zero through all operating modes.

MPPT Control of PV Water Pumping Using BLDC Motor-Inverter (BLDC 모터용 인버터를 이용한 PV 양수펌프의 MPPT 제어)

  • 김성남;백승길;조정민;이승환;오봉환;이훈구;한경희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.498-505
    • /
    • 2001
  • This paper shows how to design a global control of water pumping system using PV array, and tracked maximum power point of PV array only the inverter using the vector control of BLDC motor, and finding the relationships among the DC magnitudes and AC ones in order to omit the DC/DC converter. Conventional MPPT controller was unstable of reason of the ripple-current of DC link in three-phase invertor. Thus, in this paper the control algorithm of BLDC motor using $i_qs$ current is composed to improve the insecurity of conventional MPPT controller To prove the excellence of the proposed method, the contents of this paper is analyzed by means of simulation and testing for the results applying the method that J. A Domfnguez had applied to asynchronous motor to BLDC motor and that of the proposed method in this paper.

  • PDF

Wind Energy Interface to Grid with Load Compensation by Diode Clamped Multilevel Inverters

  • Samuel, Paulson;Naik, M. Kishore;Gupta, Rajesh;Chandra, Dinesh
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.271-281
    • /
    • 2014
  • Fluctuating wind conditions necessitate the use of a variable speed wind turbine (VSWT) with a AC/DC/AC converter scheme in order to harvest the maximum power from the wind and to decouple the synchronous generator voltage and frequency from the grid voltage and frequency. In this paper, a combination of a three phase diode bridge rectifier (DBR) and a modified topology of the diode clamped multilevel inverter (DCMLI) has been considered as an AC/DC/AC converter. A control strategy has been proposed for the DCMLI to achieve the objective of grid interface of a wind power system together with local load compensation. A novel fixed frequency current control method is proposed for the DCMLI based on the level shifted multi carrier PWM for achieving the required control objectives with equal and uniform switching frequency operation for better control and thermal management with the modified DCMLI. The condition of the controller gain is derived to ensure the operation of the DCMLI at the fixed frequency of the carrier. The converter current injected into the distribution grid is controlled in accordance with the wind power availability. In addition, load compensation is performed as an added facility in order to free the source currents being fed from the grid of harmonic distortion, unbalance and a low power factor even though the load may be unbalanced, non-linear and of a poor power factor. The results are validated using PSCAD/EMTDC simulation studies.

Analysis of Synchronous Rectification Discontinuous PWM for SiC MOSFET Three Phase Inverters

  • Dai, Peng;Shi, Congcong;Zhang, Lei;Zhang, Jiahang
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1336-1346
    • /
    • 2018
  • Wide band gap semiconductor devices such as SiC MOSFETs are becoming the preferred devices for high frequency and high power density converters due to their excellent performances. However, the proportion of the switching loss that accounts for the whole inverter loss is growing along with an increase of the switching frequency. In view of the third quadrant working characteristics of a SiC MOSFET, synchronous rectification discontinuous pulse-width modulation is proposed (SRDPWM) to further reduce system losses. The SRDPWM has been analyzed in detail. Based on a frequency domain mathematical model, a quantitative mathematical analysis of the harmonic characteristic is conducted by double Fourier transform. Meanwhile, a switching loss model and a conduction loss model of inverter for SRDPWM have been built. Simulation and experimental results verify the result of the harmonic analysis of the double Fourier analysis and the accuracy of the loss models. The efficiencies of the SRDPWM and the SVPWM are compared. The result indicates that the SRDPWM has fewer losses and a higher efficiency than the SVPWM under high switching frequency and light load conditions as a result of the reduced number of switching transitions. In addition, the SRDPWM is more suitable for SiC MOSFET converters.

Effects of Contrast Improvement on High Voltage Rectification Type of X-ray Diagnostic Apparatus (X선 진단장치의 고압정류방식이 대조도 향상에 미치는 영향)

  • Lee, Hoo-Min;Yoon, Joon;Kim, Hyun-Ju
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.187-193
    • /
    • 2014
  • The purpose of this study was to analyze the effect on the selectivity on of high-voltage rectification device that measured the performance of the grid, and the contrast improvement ability (K factor) by measuring the scattered radiation content of the transmitted X-rays. The scattered radiation generated when the X-ray flux comes from the diagnostic X-ray generator that passes through an object. Targeting four different rectifications of X-ray generators, the mean value of the tube voltage and the tube current was measured in order to maximize the accuracy of the generating power dose within the same exposure condition. Using fluorescence meter, the content of the scattered rays that are transmitted through the acrylic was measured depending on the grid usage. When grid is not used, the content of the scattered rays was the lowest (34.158%) with the single-phase rectifier, was increased with the inverter rectifier (37.043%) and the three-phase 24-peak rectification method (37.447%). The difference of the scattered radiation content of each device was significant from the lowest 0.404% to the highest 3.289% while using 8:1 grid, the content of the scattered ray was the lowest with the single content of the scattered ray was the lowest with the single-phase rectifier (18.258%), was increased with the rectifier (25.502%) and the 24-peaks rectification (24.217%). Furthermore, there was difference up to content 7.244% to the lowest content 1.285% within three-phase 24-peaks rectification, inverter rectifications, and single-phase rectifier depending on the selectivity of the grid. Drawn from the statistical analysis, there was a similar relationship between the contrast improvement factor and the K factor. As a result, the grid selectivity and the contrast were increased within the single-phase rectifier rather than the constant voltage rectifier.

A PI Control Algorithm with Zero Static Misadjustment for Tracking the Harmonic Current of Three-Level APFs

  • He, Yingjie;Liu, Jinjun;Wang, Zhaoan;Zou, Yunping
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.175-182
    • /
    • 2014
  • Tracking harmonic current quickly and precisely is one of the keys to designing active power filters (APF). In the past, the current state feedback decoupling PI control was an effective means for three-phase systems in the current control of constant voltage constant frequency inverters and high frequency PWM reversible rectifiers. This paper analyzes in detail the limitation of the conventional PI conditioner in the APF application field and presents a novel PI control method. Canceling the delay of one sampling period and the misadjustment for tracking the harmonic current is the key problem of this PI control. In this PI control, the predictive output current value is obtained by a state observer. The delay of one sampling period is remedied in this digital control system by the state observer. The predictive harmonic command current value is obtained by a repetitive predictor synchronously. The repetitive predictor can achieve better predictions of the harmonic current. By this means, the misadjustment of the conventional PI control for tracking the harmonic current is cancelled. The experiment results with a three-level NPC APF indicate that the steady-state accuracy and dynamic response of this method are satisfying when the proposed control scheme is implemented.