Abstract
This paper deals with the implementation of three-phase VSI systems which can control the power regenerated from DC bus line to AC supply. The overall system consists of the line-to-line voltage and line current sensors, an actual power calculator using d-q transformation method, a complex power controller with PI control scheme, a gating signal generator for modified q-conduction mode, a DPLL for frequency followup, and Power circuits. Control board is constructed by using a 32-bit DSP TMS32C32, two EFLDs , six ADCs, and a DAC. To verify the performance of the proposed system, we designed and constructed the propotype with the power rating of 5kVA at AC 220V. Experimental results show that the regenerated active power is well controlled to its command vague and the regenerated reactive power still remained at nearly zero through all operating modes.
본 논문에서는 직류모선에서 교류모선으로 회생되는 전력을 제어할 수 있는 3상 전압원 인버터 시스템을 구현하였다. 전체 시스템은 선간접압 및 선전류용 센서, d-q 변환방식을 사용한 실제전력 연산기. PI제어기법을 적용한 복소전력 제어기, 수정 q도통방식을 구현하기 위한 게이팅신호 생성기, 주파수를 추종하기 위한 DPLL과 전력회로로 구성된다. 제어보드는 32비트 DSP인 TMS32C32, EFLD 2개, ACD 6개와 DAC로 구성하였다. 제안한 시스템의 성능을 검증하기 위해 교류 220V에서 5kVA 전력용량인 축소모델을 설계, 제작하였다. 실험결과, 회생 유효전력은 명령값으로 잘 제어되며 회생 무효전력은 운전동안 내내 거의 0의 값을 유지함을 확인하였다.