• Title/Summary/Keyword: three-electrode system

Search Result 194, Processing Time 0.032 seconds

Manufacturing of Micro-needle Using Micro-EDM Process (마이크로 EDM공정을 이용한 마이크로 바늘의 제조)

  • Lee, Choon-Mee;Kwon, Won Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.3
    • /
    • pp.285-291
    • /
    • 2017
  • Micro-needles are used as transferring devices for sampling of tiny constitute substances from biological bodies. Typically, nickel is used as a coating to improve the rigidity of micro-needles. This study introduces the methodology to manufacture a WC needle with very high hardness and toughness. Micro-EDM technology was used to manufacture micro-needles with holes $130{\mu}m$ in diameter and $2300{\mu}m$ in length. A micro-needle was aligned to the micro-EDM electrode using a custom two degree-of-freedom alignment system. A three-step manufacturing technique was developed to drill a micro-hole using a WC electrode. In the first process, an electrode $105{\mu}m$ in diameter was used to make a hole. Electrodes of 90 and $105{\mu}m$ diameters were used in the second and third process, respectively. Consequently, a WC micro-needle with an inner hole of $135{\mu}m$ diameter, length of $2300{\mu}m$, and outer diameter of $300{\mu}m$ was developed.

The Charecteristics of Superposed Discharge Type Ozonizing System Considering the Change of Temperature of. the Supplied Gas (원료가스의 온도변화를 고려한 중첩방전형 오존발생장치의 특성)

  • Lee, Sang-Keun;Song, Hyun-Jig;Chun, Byung-Joon;Kim, Yeong-Hun;Kim, Sang-Gu;Park, Won-Zoo;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1705-1707
    • /
    • 1998
  • In this paper, a superposed discharge type ozonizer was designed and manufactured. The ozonizer is equipped with three electrodes : central electrode, internal electrode and external electrode, and it consists of two gaps. The ozone is generated by superposing silent discharge, which are respectively generated betweens two gaps. This paper describes the following two characteristics : (1) 'the characteristics of discharge with variation with output voltage of AC High Voltage source, quantity of the supplied gas and discharge voltage (2) the characteristics of ozone discharge power, temperature of the supplied gas.

  • PDF

Diagnosis of Trace Toxic Uranium Ions in Organic Liver Cell

  • Ly, Suw Young;Pack, Eun Chul;Choi, Dal Woong
    • Toxicological Research
    • /
    • v.30 no.2
    • /
    • pp.117-120
    • /
    • 2014
  • Uranium is toxic and radioactive traces of it can be found in natural water and soils. High concentrations of it in biological systems cause genetic disorders and diseases. For the in vivo diagnosis, micro and nano range detection limits are required. Here, an electrochemical assay for trace toxic uranium was searched using stripping voltammetry. Renewable and simplified graphite pencils electrode (PE) was used in a three-electrode cell system. Seawater was used instead of an electrolyte solution. This setup can yield good results and the detection limit was attained to be at $10{\mu}gL^{-1}$. The developed skill can be applied to organic liver cell.

Positioning of Partial Discharge in Insulation Oil (유중 부분방전의 위치 추정)

  • Kil, Gyung-Suk;Park, Dae-Won;Jang, Un-Yong;Seo, Dong-Hoan;Park, Hee-Chul
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1861-1867
    • /
    • 2010
  • This paper described the positioning algorithm of partial discharge in insulation oil by acoustic method for the application of an on-line diagnosis in oil-immersed transformers. In the experiment, five AE sensors having the resonant frequency of 150 kHz were used, and a signal conditioner was fabricated. A needle-plane electrode system which is composed of a needle with a curvature radius of $10{\mu}m$ and a plane electrode with a diameter of 60 mm was installed to simulate partial discharges in insulation oil. From the time difference of arrival (TOA) of acoustic signal, we calculated the location of partial discharge in insulation oil. In the experiment, an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the experimental results, the positioning error of PD calculated by three AE sensors was within 4%.

  • PDF

New PDP cell designs for high luminous efficiency and radiation transport model in PDP

  • Yang, Sung-Soo;Shin, Seung-Won;Kim, Hyun-Chul;Lee, Jae-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.590-593
    • /
    • 2002
  • Using two- and three-dimensional fluid simulation codes, we have suggested several new plasma display panel (PDP) cell structures that have high luminous efficiency compared with conventional structure. To improve the luminance and discharge efficiency, we utilize long discharge path, lower electric field region, and reduction of power consumption by adding one auxiliary electrode or reducing the electrode area. Consequently, luminous efficiency increases about 1.8 times. Furthermore for the resonance radiation trapping effect in PDP system, we have described a self-consistent radiation transport model coupled with fluid simulation using modified Holstein's equation.

  • PDF

Recognition of Partial Discharge Patterns (부분방전 패턴의 인식)

  • 이준호;이진우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.2
    • /
    • pp.8-17
    • /
    • 2000
  • In this work, two approaches were proposed for the recognition of partial discharge patterns. The first approach was neural network with backpropagation algorithm, and the second approach was angle calculation between t재 operator vectors. PD signals were detected using three electrode systems; IEC(b), needle-plane and CIGRE method II electrode system. Both of neural network and angle comparison method showed good recognition performance for the patterns similar to the trained patterns. And the number of operators to be used had a great influence on the recognition performance to the untrained patterns.

  • PDF

Performance Investigation of a Continuously Variable ER Damper for Passenger Vehicles (승용차용 연속가변 ER댐퍼의 성능연구)

  • Kim, K.S.;Chang, E.;Choi, S.B.;Cheong, C.C.;Suh, M.S.;Yeo, M.S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.6
    • /
    • pp.69-77
    • /
    • 1995
  • This paper presents performance investigation of a continuously variable ER(Electro-Rheological) damper for passenger vehicles. A dynamic model of the damper is formulated by incorporating electric field-dependent Bingham properties of the ER fluid. The Bingham properties are experimentally obtained through Couette type electroviscous measurement with respect to two different particle concentrations. The governing equation of the hydraulic model treating three components of fluid resistances;electrode duct flow, check valve flow and piston gap flow, is achieved via the bond graph method. A prototype ER damper is then designed and manufactured on the basis of parameter analysis. The damping forces of the system are experimentally evaluated by changing the intensity of the electric field, the particle concentration and the electrode gap.

  • PDF

Characteristics of Surface Flashover on Partially Immersed of Spacer in Liquid Nitrogen (액체질소 중에서 spacer의 부분적 침적에 대한 연면 방전특성)

  • 김영석;이병성;백승명;정종만;정순용;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.2
    • /
    • pp.177-182
    • /
    • 2000
  • Composite insulation system of liquid nitrogen and solid spacer is widely applied in high temperature superconduction power machine. This study has three step procedure. As follow, first step is composition of parallel deposited electrode and vertically deposited electrode along the direction of immersion in liquid nitrogen(LN2). Second step is investigation into surface flashover voltage of solid spacer under partially immersed in LN2, and last step is comparison the result of this research with that of fully immersed in LN2 and at cryogenic temperature gaseous nitrogen(GN2). This result presented that surface flashover voltage along solid spacer half immersed in LN2 was almost the same as that of fully immersed spacer when the thickness of spacer(t) was t<10mm. In the case of t> 10mm, however, spacer flashover voltage was equal to that obtained in GN2 at cryogenic temperature. And the immersed direction functions as role of deciding the difference of surface flashover voltage.

  • PDF

Electrochemical Properties of Spinel $LiMn_2O_4$Synthesized at Various Sintering Condition (열처리 조건에 따른 스피넬 $LiMn_2O_4$의 전기 화학적 특성)

  • 한태희;박종광;한병성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.12 no.1
    • /
    • pp.50-55
    • /
    • 1999
  • We have investigated the $LiMn_2O_4$system as an cathode material for lithium rechargeable batteries. $LiMn_2O_4$spinel oxides have been synthesized by a solid state methode. We varied sintering time at a fixed sintering temperature of 75$0^{\circ}C$. In order to investigate the electrochemical properties of prepared $LiMn_2O_4$we assembled three-electrode cells using the working electrode as active material and Li metal as the counter and reference electrodes. The electrolyte was 1 M LiPE$_{6}$-EC:DEC(1:1 by volume). The particle size of sample synthesized at 75$0^{\circ}C$ ranged about 60$\mu m$. The discharge capacity of a cell involving spinel $LiMn_2O_4$ increased with increasing sintering time.e.

  • PDF

A Study on the circuit design and measurement method for the measurement of active points on skin (피부 활성점 측정을 위한 회로설계 및 측정방법연구)

  • Kim, Min Soo;Cho, Young Chang
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.713-718
    • /
    • 2020
  • The method of measuring skin active points is a technique for obtaining a lot of biometric information because it is measured with convenience, low cost and non-invasive methods. In this paper, we used in a three electrode measure method that has the advantage of measuring the impedance of the APs under the skin. The impedance measuring method is well illustrated by a simple model of an equivalent electrical circuit that correlates well with experimental results. The characteristic frequencies of APs are about 15-30HZ higher than that of surrounding skin and the values of measured reactance are about 35-77KΩ smaller. This technology analyzed accurately and objectively the reactance and characteristic frequency of APs and the surrounding skin using a non-invasive measuring system.