• 제목/요약/키워드: three unit bridge restorations

검색결과 8건 처리시간 0.022초

Knitted Glass Fabric 강화 복합레진을 사용한 고정성 치과보철물에 대한 적용성 평가 (A FEASIBILITY STUDY ON THE APPLICATION OF THE KNITTED GLASS FABRIC COMPOSITES TO FIXED PROSTHODONTIC RESTORATION IN DENTISTRY)

  • 정재민;이규복;조광헌
    • 대한치과보철학회지
    • /
    • 제40권5호
    • /
    • pp.429-440
    • /
    • 2002
  • Current dental restorations present a relatively weak resistance to fracture. Owing to their unique mechanical properties, fibre-reinforced polymers are now being considered. Unidirectional or woven continuous fibres, made of glass, polyethylene, carbon or Kevlar, have been evaluated. This study focused on the use of glass fibre knitted fabrics to reinforce acrylate resins, in order to investigate the possibility to construct single crowns as well as three unit bridges. Some points affecting the final composite system were tested ; 1) static strength, with focus on the stress transfer under a occlusal contact point ; 2) modelling of a three nit bridge ; 3) fatigue strength as a posterior three unit bridge material. The study demonstrated that knitted fabric reinforcements are showing an interesting compromise between stiffness, static strength for single crown. For three unit bridge applications in the posterior arch, however knitted glass fabric reinforcements were not strong enough in fatigue An additional reinforcement in the posterior arch fixed partial denture design was recommended.

Maryland Bridge의 적용분포 및 결합실패에 관한 임상적 연구(I) (A Clinical Study on the Distribution and The Bond Failure of Etched(Maryland) Bridge: A Preliminary Report of 135 Cases)

  • 양재호
    • 대한치과의사협회지
    • /
    • 제25권6호통권217호
    • /
    • pp.578-587
    • /
    • 1987
  • The purpose of this was to examine the distribution and the bond failure of the acidetched ceramometal retainer (Maryland Bridge). 126 subjects who treated by faculty and residents of Department of Prosthodontics, Seoul National University Hospital from Dec. 1982 to Dec. 1986 were selected for this study. From the foregoing study author obtained the following conclusions. 1. A total of 135 restorations were placed in the mouths of patients ranging in age from 11 to 70 years (Man 62, woman 64) 2. Most restorations were applied to replace anterior teeth. 3. It was found that of the total number of bridges constructed 59.3 percent were the three-unit type. 4. Replacing one tooth missing was the most frequent cases(74.1 percent). 5. Of the total number of cases, 10.4percent showed bond failure. 6. The bond failure, author suggest, be due to one or more of mis-fit of framework, occlusion, material in itself, faulty case selection and lack of technique.

  • PDF

MARYLAND BRIDGE의 적용분포 및 결합실패에 관한 임상적 연구(I) (A CLINICAL STUDY ON THE DISTRIBUTION AND THE BOND FAILURE OF ETCHED (MARYLAND) BRIDGE: A PRELIMINARY REPORT OF 135 CASES)

  • 양재호
    • 대한치과보철학회지
    • /
    • 제24권1호
    • /
    • pp.7-16
    • /
    • 1986
  • The purpose of this study was to examine the distribution and the bond failure of the acid-etched ceramometal retainer (Maryland Bridge). 126 subjects who treated by faculty and residents of Department of Prosthodontics, Seoul National University Hospital from Dec. 1982 to Dec. 1986 were selected for this study. From the foregoing study author obtained the following conclusions. 1. A total of 135 restorations were placed in the mouths of patients ranging in age from 11 to 10 years (man 62, woman 64). 2. Most restorations were applied to replace anterior teeth. 3. It was found that of the total number of bridges constructed 59.3 percent were the three-unit type. 4. Replacing one tooth mining was the most frequent cases (74.1 percent). 5. Of the total number of cases, 10.4 percent stowed bond failure. 6. The bond failure, author suggest, be due to one or more of mis-fit of framework, occlusion, material in itself, faulty case selection and lack of technique.

  • PDF

보철물 조건에 따른 Periotest수치의 실험적 평가 (IN VITRO EVALUATION OF PERIOTEST VALUES UNDER VARIOUS CONDITIONS OF PROSTHESES)

  • 한중석
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.793-800
    • /
    • 1997
  • Periotest(Siemens, Germany) has been used to test mobility of the implants clinically, however the effects of target materials and connection methods on the PTVs(Periotest Values) have not been evaluated. Periotest has been regarded as a reliable and objective tool to test implant and natural teeth mobility clinically, however this instrument showed different PTVs under various test conditions. This in vitro study was designed to compare PTVs of different veneering materials and prosthodontic designs (single and bridge restorations). To compare the effects of veneering materials on PTVs, 1 mm thickness of five different testing materials (porcelain, type III gold alloy, pure titanium, composite resin, acrylic resin) were placed on the resin block. Three full length of 13 mm Mark II implant fixtures were embedded into autopolymerizing resin block to fabricate single and bridge restorations. To evaluate effects of the connection method in single restorations, PTVs of screw retained(UCLA type) and cementation type(Cera-One system) were compared. Finally, to test reliability of PTVs of the final restorations, screw retained three unit short span PFM bridges were fabricated on the standard and Estheti-Cone abutments. All testing components were tightened with torque controller and PTVs of all specimens were measured 15 times for statistical analysis with SAS program. Following conclusions were made within the limit of this in vitro study. 1. PTVs of type III gold alloy, grade II titanium, composite resin veneering materials showed no significant differences, however acrylic resin and porcelain showed significant differences (P<0.05). 2. Single tooth restorations showed consistent PTVs as long as proper torque force was applied. 3. PTVs of bridge type prostheses was inconsistent regardless of abutment types. 4. PTVs of the prostheses showed higher scores and standard deviations than those of abutments regardless types of connection (P<0.05).

  • PDF

Occlusal rehabilitation of posterior fixed prostheses: A clinical report

  • Yeo In-Sung;Yang Jae-Ho
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.313-318
    • /
    • 2001
  • Masticatory function is more important than esthetics in posterior fixed restoration. The usual technique-mounting the casts on a semi-adjustable articulator, etc. -cannot make all patients satisfied with their restorations. For example, functionally generated path technique can be an easier and more satisfactory method in the restoration of group function. These clinical reports describe various approaches for occlusal restoration of relatively simple posterior fixed protheses according to patients occlusal patterns. The 3-unit bridge restoration is one of the most popular treatment options in prosthodontics. Because dentists have much experiences of it, they restore a missing span of one tooth mechanically, that is, without special consideration. While esthetics is important in making an anterior 3-unit fixed prostheses, mastication is more focused on in posterior 3-unit bridge restoration. Many dentists are concerned about various aspects in esthetics, such as morphology of the tooth, value, chroma, hue, translucency, surface texture, etc. But they do not usually consider various methods to restore occlusion. They treat one-tooth-missing area in a similar way in spite of patients having variety of occlusal patterns. Three cases are presented here in 3 or 4-unit bridge restoration. They show some methods to restore patients' occlusal patterns.

  • PDF

CAD/CAM 밀링 시스템을 활용한 단일 치관과 3본 교의치의 3D 적합도 평가 (Three-dimensional evaluation of the internal adaptation of single and three-unit fixed dental restoration by CAD/CAM milling system)

  • 김소리;김총명;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.35-42
    • /
    • 2017
  • Purpose: The purpose of this paper was to evaluate the occurrence of errors regarding adaptation by conducting a three-dimensional assessment comparing the bridge type dental restoration after the cutting process, which has multiple abutments, with a single type dental restoration. Methods: By using ten identical files obtained by scanning the master model, thirty designs were created consisting of ten maxillary right first premolars and ten maxillary right first molars with single crown abutments, along with ten bridge designs with the identical abutment. A 5-axis milling machine was used to produce the design file. The produced denture prostheses were scanned using a silicone replica for a STL file. An evaluation was conducted using 3D analysis software on the master model and each of the thirty data files. Results: The RMS value of the pre-molar (14) was $38.4{\pm}4{\mu}m$ for single and $54.7{\pm}6{\mu}m$ for bridge abutment; therefore, a statistically significant difference was observed for single and bridge designs although both shared the same abutment form (P<.05). Also, the RMS value of the molar (16) was $47.6{\pm}2{\mu}m$ and $56.6{\pm}5{\mu}m$ for the single and bridge designs, respectively, thereby presenting a statistically significant difference (P<.05). Conclusion: As a result, dental prosthesis fabricated using the single method presented better internal adaptation outcomes.

FRACTURE STRENGTH AND MARGINAL FIT OF IN-CERAM, COPY-MILLED IN-CERAM, AND IPS EMPRESS 2 ALL-CERAMIC BRIDGES

  • Hwang Jung-Won;Yang Jae-Ho;Lee Sun-Hyung
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.641-658
    • /
    • 2001
  • All-ceramic restorations have become an attractive alternative to porcelain-fused-to-metal crowns. In-Ceram, and more recently IPS Empress 2 were introduced as a new all-ceramic system for single crowns and 3-unit fixed partial dentures. But their strength and marginal fit are still an important issue. This study evaluated the fracture resistance and marginal fit of three systems of 3 unit all-ceramic bridge fabricated on prepared maxillary anterior resin teeth in vitro. The 3 all-ceramic bridge systems were: (1) a glass-infiltrated, sintered alumina system (In-Ceram) fabricated conventionally, (2) the same system with copy-milled alumina cores (copy-milled In-Ceram), (3) a heat pressed, lithium disilicate reinforced glass-ceramic system (IPS Empress 2). Ten bridges of each system with standardized design of framework were fabricated. All specimens of each system were compressed at $55^{\circ}$ at the palatal surface of pontic until catastrophic fracture occurred. Another seven bridges of each system were fabricated with standard method. All of the bridge-die complexes were embedded in epoxy resin and sectioned buccolingually and mesiodistally. The absolute marginal discrepancy was measured with stereomicroscope at ${\times}50$ power. The following results were obtained: 1. There was no significant difference in the fracture strength among the 3 systems studied. 2. The Weibull modulus of copy-milled In-Ceram was higher than that of In-Ceram and IPS Empress 2 bridges. 3. Copy-milled In-Ceram($112{\mu}m$) exhibited significantly greater marginal discrepancy than In Ceram ($97{\mu}m$), and IPS Empress 2 ($94{\mu}m$) at P=0.05. 4. The lingual surfaces of the ceramic crowns showed smaller marginal discrepancies than mesial and distal points. There was no significant difference between teeth (incisor, canine) at P=0.05. 5. All-ceramic bridges of three systems appeared to exhibit sufficient initial strength and accept able marginal fit values to allow clinical application.

  • PDF

Glass fiber 강화 복합레진을 사용한 3본 고정성 국소의치의 개념 설계 연구 (Conceptual Design of the Three Unit Fixed Partial Denture with Glass Fiber Reinforced Hybrid Composites)

  • 나경희;이규복;조광헌
    • 구강회복응용과학지
    • /
    • 제18권3호
    • /
    • pp.145-155
    • /
    • 2002
  • 본 연구에서는 knitted glass fabric 강화 레진에 대한 치과보철소재로서의 적용가능성을 평가하기 위한 목적으로, 가장 높은 수준의 교합하중이 작용하게 되는 구치부 3본 고정성국소의치에 이 재료를 사용하는 경우에 대해 해석을 수행하였다. 우선 구치부3본 고정성국소의치에 대해 knitted glass fabric 강화 레진을 적용한 두 가지 설계 개념을 상정하였고, 각 설계형상에 대한 유한요소해석을 하였다. 강도 평가를 위해서75N의 생리적인 반복 수직 교합 하중 조건을 부여, 보철물에 유도되는 국소응력을 피로강도측면에서 고찰하였다. 각각의 설계에는 knitted glass fabric을 모재로 하고 보강재로 unidirectional 형의 glass 복합재가 사용되었다. 본 연구에서 개념설계 된 두 가지의 3본 고정성국소의치는 수직 교합 하중 75N 에 대해 충분한 강성과 강도를 가진 것으로 분석되었다. 가공치와 knitted caps사이의 연결 부위에서 국소적인 응력 집중이 관찰되었으나 그 크기는 재료의 피로강도 범위 이내였으며 국소적인 설계변경을 통하여 응력분포를 더욱 개선할 수 있을 것으로 추정하였다. 본 연구를 통해 knitted glass fabric 은 새로운 치과 보철 소재로서의 그 가능성이 기대된다.