• Title/Summary/Keyword: three phase transformer

Search Result 224, Processing Time 0.034 seconds

Study of Deterioration Improvement of Power Fuse (전력퓨즈의 열화현상 개선에 관한 연구)

  • Song, Jae-Ki;Kim, Hwan-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3827-3831
    • /
    • 2014
  • This paper aims to solve the problem deterioration of power fuses. The deterioration of a power fuse is a cause of failure misoperation by a normal current flowing reduplicatively to fuse the element. An extension survey of a load feature rerating power fuse examined the power fuse deterioration removal, the cause of the deterioration of the power fuse, the front-after, and the thermal variation of the inside transformer room electric power equipment. The transformer showed an average improvement of $6[^{\circ}C]$. The temperature of the electrical line showed $7{\sim}8[^{\circ}C]$ improvement. The static condenser and direct reactor was $2{\sim}3[^{\circ}C]$ high-state maintenance the temperature and equipment syntonization relationship. In the subject of study $0.5{\sim}1.0[^{\circ}C]$ stabilizing three phase power fuse temperature differential was. Suggestion in the transformer room environment power equipment between the cause temperature happen elimination to deterioration of power fuse and temperature rise control.

A 3-phase step-down voltage regulator using AC choppers (교류쵸퍼를 사용한 3상 강압형 전압제어장치)

  • Ryoo, Hong-Je;Kim, Jong-Soo;Rim, Geun-Hie;Kim, Deuk-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1075-1077
    • /
    • 2002
  • This paper describes a three-phase step-down AC voltage regulator using AC chopper and auxiliary transformer which is series connected with main input. It has many advantages such as fast voltage control, high efficiency and low THD. The operation principle and PWM method of the proposed regulator are described. Experimental results show that it can be used as step-down AC voltage regulator for power saving purpose very efficiently.

  • PDF

A Study of phase controlled rectifier design of excitation system for thermal power plant (화력발전소 여자시스템 위상제어 정류기 설계에 관한 연구)

  • Lee, J.H.;Ryu, H.S.;Lim, I.H.;Song, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1015-1017
    • /
    • 2002
  • This is the study on static excitation system of synchronous generator of large capacity in new model, which was developed by KEPRI using triple redundant digital method, associate three bridges of thyristor phase controlled rectifier. This paper will discuss the design conception and the application results of system which includes the power control devices(thyristors, GTO) and power excitation potential transformer. The multi-paralleling thyristor bridge converters of N+1 method have firing circuit. The initial product manufactured by proposed design in the study is in commercial operation, completing installation and commissioning in 400MW Thermal Power Plant. The performance test is done in practical technique.

  • PDF

Test results of small scale changeover system using in neutral section for AC feeding system (축소형 교류급전시스템 절연구간 자동절체장치 성능시험)

  • Jang, Dong-Uk;Han, Moon-Seob
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.948-953
    • /
    • 2011
  • In AC railway feeding system, three phase received from the network is changed to two phase power sources with different phases. The main circuit breaker installed train is automatically open by track signal when the train passes the neutral section. In order to continuously supply power source to train, the changeover system was used in Japan. Therefore, the train is able to operate under powering condition when it was passing through the neutral section. We investigated the control method to reduce the inrush current flowing main transformer in train. To examine the inrush current and operate the static semiconductor switch such as thyristor, we manufactured the small scale the changeover system and carried out performance tests.

  • PDF

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.822-828
    • /
    • 2001
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings. Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other. This may result in wiring failure of the neutral conductor and overloading of the distribution transformer. In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed [6]. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions. The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system. This remedies overloading and power loss of the system. The experimental results on a prototype validate the proposed control approach.

  • PDF

A Study on the Characteristics of Inverter Type X-Ray Genertator (보급형 인버터식 X선발생장치의 특성에 관한 연구)

  • 박수강
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.26-29
    • /
    • 2000
  • The conventional types of X-ray generators were bulky in physical size and heavy in weight and the control accuracies of the output voltages were not always satisfacotry. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing power semiconducot devices. To decreasing the volume and the weight of high voltage transformer and to stabilize ripple. In this paper the newly developed x-ray generator in a low cost using duty modulation PWM inverter. This system verify improved performance by stabilize ripple of X-ray tube voltage and compared the reproducibility linearity and dose in single phase three phase and PSU.

  • PDF

An Evaluation of Large Scale Distribution system Unbalance (3상 조류계산에 의한 대규모 배전계통의 불평형상태 평가)

  • 송현선
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.86-93
    • /
    • 1999
  • It is necessary to calculate the system's factor for reasonable operation and security enhancerrent of large scale distribution system This paper presents an effective three phase load flow calculation for distribution system unbalance evaluation. It takes into account an untranspoed transmission line, the core loss as a functioo of voltage on the serondary side of the transformer, and a generator unbalance mxle1 which is also suitable for a salient pole machine. The load flow algorithm is used Newton-RaiDson method of load flow equations in bus phase voltage.oltage.

  • PDF

The Effect on Patient Dose Reduction with Improvement of the Output Characteristics for Inverter Type X-ray Generator (인버터식 X선발생장치의 출력특성개선이 환자피폭선량 경감에 미치는 효과)

  • Roh, Mo-Eun;Lee, Seong-Kil;Kim, Young-Keun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.27-32
    • /
    • 2011
  • The conventional types of X-ray generators were bulky in physical size and heavy in weight, and the control accuracies of the output voltages were not always satisfactory. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing power semiconductor devices. To decreasing the volume and the weight of high voltage transformer, and to stabilize ripple. In this paper, the newly developed x-ray generator in a low cost using duty modulation PWM inverter. This system verify improved performance by stabilize ripple of X-ray tube voltage and compared the reproducibility, linearity and dose in single phase, three phase and PSU.

  • PDF

An Active Feedforward Compensation for a Current Harmonics Reduction in Three-phase Grid-connected Inverters (3상 계통 연계형 인버터에서의 전류 고조파 감쇄를 위한 능동형 피드포워드 보상 기법)

  • Park, Byong-Jun;Kim, Rae-Young;Choi, Ki-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • This paper proposes a current harmonic compensation method for the grid-connected inverter, especially caused by the grid impedance. Grid impedance causes low order harmonics in the grid current and deteriorates power quality. This paper analyzes the negative impact of the grid impedance, and proposes an active feedforward compensation method. Proposing method verified through simulation and experiment with 3-phase 1.5kW voltage source inverter prototype.

A Study On High Power Factor Sine Pulse Type Power Supply For Atmospheric Pressure Plasma Cleaning System with 3-Phase PFC Boost Converter (3상 PFC 부스트 컨버터를 채용한 상압플라즈마 세정기용 고역률 정형파 펄스 출력형 전원장치에 관한 연구)

  • Han, Hee-Min;Kim, Min-Young;Seo, Kwang-Duk;Kim, Joohn-Sheok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.72-81
    • /
    • 2009
  • This paper presents quasi-resonant type high power factor ac power supply for atmospheric pressure plasma cleaning system adopting three phase PFC boost converter and it's control method. The presented ac power supply consists of single phase H-bridge inverter, step-up transformer for generating high voltage and three phase PFC boost converter for high power factor on source utility. Unlikely to the traditional LC resonant converter, the propose one has an inductor inside only. A single resonant takes place through the inside inductor and the capacitor from the plasma load modeled into two series capacitor and one resistance. The quasi-resonant can be achieved by cutting the switching signal when the load current decrease to zero. To obtain power control ability, the propose converter controlled by two control schemes. One is the changing output pulse period scheme in the manner of PFM(Pulse Frequency Modulation) control. On the other, to provide more higher power to load, the DC rail voltage is directly controlled by the 3-phase PFC boost converter. The significant merits of the proposed converter are the uniform power providing capability for high quality plasma generation and low reactive power in AC and DC side. The proposed work is verified through digital simulation and experimental implementation.