• Title/Summary/Keyword: thickness of wall

Search Result 1,571, Processing Time 0.028 seconds

The Effects of Lift-Off from Wall Thinning Signal in Pulsed Eddy Current Testing

  • Park, Duck-Gun;Angani, C.S.;Kishore, M.B.;Kim, C.G.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.17 no.4
    • /
    • pp.298-301
    • /
    • 2012
  • In order to know the effect of surface irregularity in the detection of local wall thinning of pipeline using pulsed eddy current (PEC), the lift-off effects on PEC signal have been investigated. Three kinds of parameters in the PEC signal, which is "peak amplitude", "time to peak amplitude" and "time to zero crossing" are analyzed to separate the lift-off effects in the PEC signal. The distance from sensor to the bottom of sample which is the total thickness of combined insulator and sample is kept constant. The magnitude of the differential peak amplitude is increased with increasing sample thickness, the time to peak amplitude is increased with increasing the sample thickness. To determine the effect of lift-off, a number of balanced transient responses combining wall thinning locations and lift-off distances were plotted.

A study on the process of tube end spinning by the upper bound method and the finite element method (상계해법과 유한요소법을 이용한 스피닝공정 해석에 관한 연구)

  • 김전형;홍성인;이정환;이영선
    • Transactions of Materials Processing
    • /
    • v.6 no.6
    • /
    • pp.517-526
    • /
    • 1997
  • The purpose of this study is to investigate changes in the wall thickness of tube sinking and working forces by the upper bound method and ABAQUS code. The independent variables are ; workpiece material, original wall thickness of tube, die angle, friction, and reduction of diameter. The results indicate that these five variables are factors of the increase in wall-thickness and working forces. Three variables, a inner tube wall angle and two angles of the velocity discontinuous surfaces, are optimized in this proposed velocity field by the upper bound method. In this method, we can estimate the working forces and final tube thicknesses similar to actual forming process. Optimum process variables which are obtained by upper bound method are used in ABAQUS pre-model.

  • PDF

Current Density and Thickness Effects on Magnetic Properties of Electrodeposited CoPt Magnetic Films

  • Kim, Hyeon Soo;Jeong, Soon Young;Suh, Su Jeong
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.417-421
    • /
    • 2013
  • The dominant magnetization reversal behavior of electrodeposited CoPt samples with various thicknesses deposited at different current densities was the domain wall motion by means of wall pinning. The magnetic interaction mechanism was dipolar interaction for all samples. The dipolar interaction strength was significantly affected by the sample thickness rather than by the current density, while the magnetic properties were closely related to the current density.

A Performance Equation of Bath Tubs (욕조의 보온성능연구)

  • Lee, Byung-Ho;Suh, Jung-Il
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.10 no.1
    • /
    • pp.1-11
    • /
    • 1981
  • In this paper, a new performance equation of bath tubs has been derived, which is very characteristically illuminating and in good agreement with experiments : $$T=T_{\infty}+(T_0-T_{\infty})e-\frac{k(A'_f+A_0)}{Mc_{P{\Delta}x}t$$, where $T_{\infty}$ is the temperature of the bathroom, $T_0$ that of the bathwater at t=0, k the overall heat conductivity of the tub- wall, $A'_f$ the equivalent surface area to the wall, $A_0$ the submerged area of the tub-wall, M mass of the bath-water, $C_p$ the specific heat of the bathwater and ${\Delta}x$ the thickness of the tub-wall. Here the equivalent-free surface area is written as $$A'_f=mA_f,\;m=const.(1-{\phi})^{0.88}$$ : where m is a numerical factor which is determined by a simple experiment and some calculation, {\phi}$ the relative humidity and $A_f$ the real free-surface area. From this study, it has been clarified that cooling of bath-water is mainly due to mass-transfer through evaporation from the free surface and conductive heat loss through the tub-wall is minor, which rather gaily mock at common sense. The effect of keeping bathwater warn by increase of the tub-wall thickness is also analyzed by a new idea of the thickness gain factor.

  • PDF

Bending and Shear Capacity of Reinforced Concrete Protective Wall (휨과 전단을 고려한 철근콘크리트 방호벽 성능에 관한 연구)

  • Young Beom Kwon;Jong Yil Park
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.44-51
    • /
    • 2023
  • With the recent increase in gas energy use, risk management for explosion accidents has been emphasized. Protective walls can be used to reduce damage from explosions. The KOSHA GUIDE D-65-2018 suggests the minimum thickness and height of protective walls, minimum reinforcement diameter, and maximum spacing of reinforcements for the structural safety of the protective walls. However, no related evidence has been presented. In this study, the blast load carrying capacity of the protective wall was analyzed by the pressure-impulse diagrams while changing the yield strength of the reinforcement, concrete compressive strength, reinforcement ratio, protective wall height, and thickness, to check the adequacy of the KOSHA GUIDE. Results show that failure may occur even with design based on the criteria presented by KOSHA GUIDE. In order to achieve structural safety of protective walls, additional criteria for minimum reinforcement yield strength and maximum height of protective wall are suggested for inclusion in KOSHA GUIDE. Moreover, the existing value for minimum reinforcement ratio and the thickness of the protective wall should be increased.

SHIELD DESIGN OF CONCRETE WALL BETWEEN DECAY TANK ROOM AND PRIMARY PUMP ROOM IN TRIGA FACILITY

  • Khan, M J H;Rahman, M;Ahmed, F U;Bhuiyan, S I;Haque, A;Zulquarnain, A
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.190-193
    • /
    • 2007
  • The objective of this study is to recommend the radiation protection design parameters from the shielding point of view for concrete wall between the decay tank room and the primary pump room in TRIGA Mark-II Research Reactor Facility. The shield design for this concrete wall has been performed with the help of Point-kernel Shielding Code Micro-Shield 5.05 and this design was also validated based on the measured dose rate values with Radiation Survey Meter (G-M Counter) considering the ICRP-60 (1990) recommendations for occupational dose rate limit ($10{\mu}Sv/hr$). The recommended shield design parameters are: (i) thickness of 114.3 cm Ilmenite-Magnetite Concrete (IMC) or 129.54 cm Ordinary Reinforced Concrete (ORC) for concrete wall A (ii) thickness of 66.04 cm Ilmenite-Magnetite Concrete (IMC) or 78.74 cm Ordinary Reinforced Concrete (ORC) for concrete wall B and (iii) door thickness of 3.175 cm Mild Steel (MS) on the entrance of decay tank room. In shielding efficiency analysis, the use of I-M concrete in the design of this concrete wall shows that it reduced the dose rate by a factor of at least 3.52 times approximately compared to ordinary reinforced concrete.

Round Robin Test for Reliability Evaluation of Ultrasonic Thickness Measurement Results in Nuclear Power Plant Pipelines (원전감육배관 UT 두께측정 결과의 신뢰도 평가를 위한 다자비교시험)

  • Lee, Seung-Joon;Yi, Won-Geun;Lee, Joon-Hyun;Lee, Sung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1702-1707
    • /
    • 2007
  • The reduction of pipe-thickness induced by flow accelerated corrosion (FAC) is one of the most serious problems on the maintenance of piping system in nuclear power plants (NNP). If the thickness of a pipe component is reduced below the critical level, it cannot sustain pressure and consequently results in leakage or rupture. For this reason, wall thinning by FAC has been inspected in secondary side piping systems in NPPs. In this research Round Robin Test (RRT) was conducted to verify confidence of wall thinning measurement system in NPP. 12 inspectors from 3 companies participated and 23 specimens were used according to standard practice in RRT. The gage R&R analysis was introduced in regard to repeatability and reproducibility that are affected to measurement system errors. Confidence intervals of thickness measurement system were obtained.

  • PDF

TWO-DIMENSIONAL STAGNATION FLOW TOWARD A PLANE WALL COATED WITH MAGNETIC FLUID OF UNIFORM THICKNESS (균일 두께의 자성유체 피막이 있는 평면 벽을 향하는 2차원 정체 유동)

  • Ko, Hyung-Jong;Kim, Kyoung-Hoon;Kim, Se-Woong
    • Journal of computational fluids engineering
    • /
    • v.12 no.4
    • /
    • pp.20-27
    • /
    • 2007
  • Two-dimensional stagnation flow toward a plane wall coated with magnetic fluid of uniform thickness is investigated. The flow field is represented as a similarity solution of the Navier-Stokes equation for this incompressible laminar flow. The resulting third order ordinary differential equation is solved numerically by using the shooting method and by determining two shooting parameters so as to satisfy the boundary and interface conditions. Features of the flow including streamline patterns are investigated for the varying values of density ratio, viscosity ratio, and Reynolds number. An adverse flow with double eddy pair in magnetic fluid region is found to emerge as the Reynolds number becomes higher than a threshold value. The results for the interface velocity, interface and wall shear stress, and boundary layer and displacement thickness are also presented.

Parametric study on the lateral strength of URM wall, retrofitted using ECC mortar

  • Niasar, Alireza Namayandeh;Alaee, Farshid Jandaghi;Zamani, Sohail Majid
    • Earthquakes and Structures
    • /
    • v.18 no.4
    • /
    • pp.451-466
    • /
    • 2020
  • In this paper, the effect of Engineered Cementitious Composites (ECC) on the lateral strength of a bearing unreinforced Masonry (URM) wall, was experimentally and numerically investigated. Two half scale solid walls were constructed and were tested under quasi-static lateral loading. The first specimen was an un-retrofitted masonry wall (reference wall) while the second one was retrofitted by ECC mortar connected to the wall foundation via steel rebar dowels. The effect of pre-compression level, ECC layer thickness and one or double-side retrofitting on the URM wall lateral strength was numerically investigated. The validation of the numerical model was carried out from the experimental results. The results indicated that the application of ECC layer increases the wall lateral strength and the level of increment depends on the above mentioned parameters. Increasing pre-compression levels and the lack of connection between the ECC layer and the wall foundation reduces the influence of the ECC mortar on the wall lateral strength. In addition, the wall failure mode changes from flexure to the toe-crashing behavior. Furthermore, in the case of ECC layer connected to the wall foundation, the ECC layer thickness and double-side retrofitting showed a significant effect on the wall lateral strength. Finally, a simple method for estimating the lateral strength of retrofitted masonry walls is presented. The results of this method is in good agreement with the numerical results.

AXISYMMETRIC STAGNATION FLOW NEAR A PLANE WALL COATED WITH A MAGNETIC FLUID OF UNIFORM THICKNESS (균일 두께로 자성유체가 피막된 평면 벽 주의의 축대칭 정체 유동)

  • Ko, Hyung-Jong;Kim, Kyoung-Hoon;Kim, Se-Woong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.10a
    • /
    • pp.39-44
    • /
    • 2007
  • A similarity solution of the Navier-Stokes equation for the axisymmetric stagnation flow near a plane wall coated with a magnetic fluid of uniform thickness is constructed. The shape functions representing the flow in two (magnetic and normal) fluid layer are determined from a third order boundary value problem, which is solved by the Runge-Kutta method with two shooting parameters. Features of the flow including streamline pattern and interface velocity are investigated for the varying values of density ratio, viscosity ratio, and Reynolds number. The results for the interface and wall shear stress, boundary layer and displacement thickness are also presented.

  • PDF