DOI QR코드

DOI QR Code

Parametric study on the lateral strength of URM wall, retrofitted using ECC mortar

  • Received : 2019.09.12
  • Accepted : 2020.01.18
  • Published : 2020.04.25

Abstract

In this paper, the effect of Engineered Cementitious Composites (ECC) on the lateral strength of a bearing unreinforced Masonry (URM) wall, was experimentally and numerically investigated. Two half scale solid walls were constructed and were tested under quasi-static lateral loading. The first specimen was an un-retrofitted masonry wall (reference wall) while the second one was retrofitted by ECC mortar connected to the wall foundation via steel rebar dowels. The effect of pre-compression level, ECC layer thickness and one or double-side retrofitting on the URM wall lateral strength was numerically investigated. The validation of the numerical model was carried out from the experimental results. The results indicated that the application of ECC layer increases the wall lateral strength and the level of increment depends on the above mentioned parameters. Increasing pre-compression levels and the lack of connection between the ECC layer and the wall foundation reduces the influence of the ECC mortar on the wall lateral strength. In addition, the wall failure mode changes from flexure to the toe-crashing behavior. Furthermore, in the case of ECC layer connected to the wall foundation, the ECC layer thickness and double-side retrofitting showed a significant effect on the wall lateral strength. Finally, a simple method for estimating the lateral strength of retrofitted masonry walls is presented. The results of this method is in good agreement with the numerical results.

Keywords

Acknowledgement

The authors acknowledge the assistance of laboratory staff of material and structural engineering departments of Building and Housing Research Center (B.H.R.C), Tehran, Iran. The authors also like to thank Mr. Mansoor Jamee for his help in carrying out the experiments.

References

  1. ABAQUS (2013), "Online documentation", SIMULIA Inc.
  2. ACI 318-08 (2008), "Building code requirements for structural concrete and commentary", American Concrete Institute.
  3. ACI/440.7R. (2010), "Guide for the design and construction of externally bonded fiber-reinforced polymer systems for strengthening un-reinforced masonry structures", American concrete institute (ACI).
  4. AL-Gemeel, A. and Zhuge, Y. (2018), "Experimental investigation of textile reinforced engineered cementitious composite (ECC) for square concrete column confinement", Construct. Build. Mat., 174(20), 594-602. https://doi.org/10.1016/j.conbuildmat.2018.04.161.
  5. ASCE/41-17 (2017), "Seismic evaluation and retrofit of existing buildings", Reston, Virginia, 20191-4382: American Society of Civil Engineers.
  6. ASTM-C1314-16 (2016), "Standard test method for compressive strength of masonry prisms", West Conshohocken.
  7. ASTM-C270-07 (2007), "Standard specification for mortar for unit masonry", West Conshohocken.
  8. ASTM-C469-14 (2002), "Standard test method for static modulus of elasticity and poisson's ratio of concrete in compression", West Conshohocken.
  9. ASTM-C67-14 (2014), "Standard test methods for sampling and testing brick and structural clay tile", West Conshohocken.
  10. ATC 24 (1992), "Guidelines for cyclic seismic testing of components of steel structures", Applied Technology Council, Redwood City.
  11. Basilio, I., Fedele, R., Lourenco, P.B. and Milani, G. (2014), "Assessment of curved FRP-reinforced masonry prisms: experiments and modeling", Construct. Build. Mat., 51, 492-505. https://doi.org/10.1016/j.conbuildmat.2013.11.011.
  12. Bernat-Maso, E., Gil, L. and Roca, P. (2015), "Numerical analysis of the load-bearing capacity of brick masonry walls strengthened with textile reinforced mortar and subjected to eccentric compressive loading", Eng. Struct., 91, 96-111. https://doi.org/10.1016/j.engstruct.2015.02.032.
  13. Bertolesi, E., Carozzi, F.G., Milani, G. and Poggi, C. (2014), "Numerical modeling of Fabric Reinforce Cementitious Matrix composites (FRCM) in tension", Construct. Build. Mat., 70, 531-548. https://doi.org/10.1016/j.conbuildmat.2014.08.006.
  14. Bilgin, H. and Huta, E. (2018), "Earthquake performance assessment of low and mid-rise buildings: Emphasis on URM buildings in Albania", Earthq. Struct., 14(6), 599-614. https://doi.org/10.12989/eas.2018.14.6.000.
  15. Bolhassani, M., Hamid, A., Lau, A. and Moon, F. (2015), "Simplified micro modeling of partially grouted masonry assemblages", Construct. Build. Mat., 83, 159-73. https://doi.org/10.1016/j.conbuildmat.2015.03.021.
  16. Carozzi, F., Milani, G. and Poggi, C. (2014), "Mechanical properties and numerical modeling of Fabric Reinforced Cementitious Matrix (FRCM) systems for strengthening of masonry structures", Compos. Struct., 107, 711-725. https://doi.org/10.1016/j.compstruct.2013.08.026.
  17. Carozzi, F.G., Poggi, C., Bertolesi, E. and Milani, G. (2018), "Ancient masonry arches and vaults strengthened with TRM, SRG and FRP composites: Experimental evaluation", Compos. Struct., 187(1), 466-480. https://doi.org/10.1016/j.compstruct.2017.12.075.
  18. Darbhanzi, A., Marefat, M.S., Khanmohammadi, M., Moradimanesh, A. and Zare, H. (2018), "Seismic performance of retrofitted URM walls with diagonal and vertical steel strips", Earthq. Struct., 14(5), 449-458. https://doi.org/10.12989/eas.2018.14.5.449.
  19. Dehghani, A., Fischer, G. and Alahi, F.N. (2015), "Strengthening masonry infill panels using engineered cementitious composites", Mat. Struct., 48(1-2), 185-204. https://doi.org/10.1617/s11527-013-0176-4.
  20. Deng, M. and Yang, S. (2018), "Cyclic testing of unreinforced masonry walls retrofitted with engineered cementitious composites", Construct. Build. Mat., 177, 395-408. https://doi.org/10.1016/j.conbuildmat.2018.05.132.
  21. Dolatshahi, K.M. (2012), "Computational, analytical and experimental modeling of masonry structures", State Univ. New York at Buffalo.
  22. ElGawady, M., Lestuzzi, P. and Badoux, M. (2007), "Static cyclic response of masonry walls retrofitted with fiber-reinforced polymers", J. Compos. Construct, 11(1), 50-61. https://doi.org/10.1061/(ASCE)1090-0268(2007)11:1(50).
  23. EN-12390-3 (2009), "Testing hardened concrete - part 3: compressive strength of test specimens", European Committee for Standardization, Brussels, Belgium:
  24. EN 1052-3 (2007), "Methods of test for masonry, Part 3: determination of initial shear strength", European Standard.
  25. FEMA-F.461 (2007), "Interim protocols for determining seismic performance characteristics of structural and nonstructural components through laboratory testing", Federal Emergency Management Agency, Redwood City.
  26. Ghiassi, B., Soltani, M. and Tasnimi, A. (2011), "Seismic evaluation of masonry structures strengthened with reinforced concrete layers", J. Struct. Eng., 138(6), 729-743. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000513.
  27. Hung, C. and Chen, Y. (2016), "Innovative ECC jacketing for retrofitting shear-deficient RC members", Construct. Build. Mat., 111(15), 408-418. https://doi.org/10.1016/j.conbuildmrat.2016.02.077.
  28. Ismail, N., El-Maaddawy, T. and Khattak, N. (2018), "Quasi-static in-plane testing of FRCM strengthened non-ductile reinforced concrete frames with masonry infills", Construction and building materials, 186, 1286-1298. https://doi.org/10.1016/j.conbuildmat.2018.07.230
  29. ISO-16670:2003 (2003), "Timber structures - joints made with mechanical fasteners - quasi-static reversed cyclic test method", ISO 14443, International Organization for Standardization Geneva, Switzerland.
  30. JSCE2008 (2008), "Recommendation for design and construction of high performance fiber reinforced cement composites with multiple fine cracks", Jpn. Soc. Civ. Eng.
  31. Kadam, S., Singh, Y. and Li, B. (2014), "Strengthening of unreinforced masonry using welded wire mesh and micro-concrete-Behaviour under in-plane action", Construct. Build. Mat., 54(15), 247-257. https://doi.org/10.1016/j.conbuildmat.2013.12.033.
  32. Kesner, K. and Billington, S.L. (2004), "Tension, compression and cyclic testing of engineered cementitious composite materials", MCEER.
  33. Kota, S.K., Rama, J.S. and Murthy, A.R. (2019), "Strengthening RC frames subjected to lateral load with Ultra High-Performance fiber reinforced concrete using damage plasticity model", Earthq. Struct., 17(2), 221-232. https://doi.org/10.12989/eas.2019.17.2.221.
  34. Krawinkler, H. (2009), "Loading histories for cyclic tests in support of performance assessment of structural components", In the 3rd International Conference on Advances in Experimental Structural Engineering, San Francisco. U.S.A.
  35. Kyriakides, M.A. and Billington, S.L. (2014), "Behavior of unreinforced masonry prisms and beams retrofitted with engineered cementitious composites", Mat. Struct., 47(9), 1573-1587. https://doi.org/10.1617/s11527-013-0138-x.
  36. Liang, X. and Xing, P. (2018), "Seismic behavior of fiber reinforced cementitious composites coupling beams with conventional reinforcement", Earthq. Struct., 14(3), 261-271. https://doi.org/10.12989/eas.2018.14.3.261.
  37. Lin, Y., Lawley, D., Wotherspoon, L. and Ingham, J. (2016), "Out-of-plane testing of unreinforced masonry walls strengthened using ECC shotcrete", Struct., 7, 33-42. https://doi.org/10.1016/j.istruc.2016.04.005.
  38. Lin, Y., Wotherspoon, L., Scott, A. and Ingham, J. (2014), "In-plane strengthening of clay brick unreinforced masonry wallettes using ECC shotcrete", Eng. Struct., 66(1), 57-65. https://doi.org/10.1016/j.engstruct.2014.01.043.
  39. Lourenco, P.J. (1997), "Computational strategies for masonry structures", Master Thesis, Delft University of Technology, Portugal.
  40. Luccioni, B. and Rougier, V. (2011), "In-plane retrofitting of masonry panels with fibre reinforced composite materials", Construct. Build. Mat., 25(4), 1772-1788. https://doi.org/10.1016/j.conbuildmat.2010.11.088.
  41. Maalej, M. and Leong, K. (2005), "Engineered cementitious composites for effective FRP-strengthening of RC beams", Compos. Sci. Technol., 65(7-8), 1120-8. https://doi.org/10.1016/j.compscitech.2004.11.007.
  42. Maalej, M., Lin, V., Nguyen, M. and Quek, S. (2010), "Engineered cementitious composites for effective strengthening of unreinforced masonry walls", Eng. Struct., 32(8), 2432-2439. https://doi.org/10.1016/j.engstruct.2010.04.017.
  43. Maso, E.B., Escrig, C., Chrysl, A.A. and Lluis, G. (2014), "Experimental assessment of textile reinforced sprayed mortar strengthening system for brickwork wallettes", Construct. Build. Mat., 50, 226-236. https://doi.org/10.1016/j.conbuildmat.2013.09.031.
  44. Milani, G., Milani, E. and Tralli, A. (2009), "Upper Bound limit analysis model for FRP-reinforced masonry curved structures. Part I: Unreinforced masonry failure surfaces", Comput. Struct., 87(23-24), 1516-1533. https://doi.org/10.1016/j.compstruc.r2009.07.007.
  45. Nezhad, R., Kabir, M. and Banazadeh, M. (2016), "Shaking table test of fibre reinforced masonry walls under out-of-plane loading", Construct. Build. Mat., 120, 89-103. https://doi.org/10.1016/j.conbuildmat.2016.05.097.
  46. Popa, V., Pascu, R., Papurcu, A. and Albota, E. (2016), "Retrofitting of squat masonry walls by FRP grids bonded by cement-based mortar", Earthq. Struct., 10(1), 125-139. https://doi.org/10.12989/eas.2016.10.1.125.
  47. Singh, S., Patil, R. and Munjal, P. (2017), "Study of flexural response of engineered cementitious composite faced masonry structures", Eng. Struct., 150(1), 786-802. https://doi.org/10.1016/j.engstruct.2017.07.089.
  48. Triantafillou, T. (2011), "Innovative textile-based composites for strengthening and seismic retrofitting of concrete and masonry structures", In Advances in FRP composites in civil engineering; springer, Berlin, Heidelberg, 3-12.
  49. Ural, A. (2013), "19th May 2011 Simav (Kutahya) earthquake and response of masonry Halil Aga Mosque", Earthq. Struct., 4(6), 671-683. https://doi.org/10.12989/eas.2013.4.6.671.
  50. Vanin, A. and Foraboschi, P. (2012), "In-plane behavior of perforated brick masonry walls", Mat. Struct., 45(7), 1019-1034. https://doi.org/10.1617/s11527-011-9814-x.
  51. Yardim, Y. and Lalaj, O. (2016), "Shear strengthening of unreinforced masonry wall with different fiber reinforced mortar jacketing", Construct. Build. Mat., 102, 149-154. https://doi.org/10.1016/j.conbuildmat.2015.10.095.