• Title/Summary/Keyword: thermoelectric device

검색결과 105건 처리시간 0.022초

석탄 노즐내 미분탄 분리장치의 입자 분리 효과에 관한 실험적 연구 (An Experimental Study on the Separating Effect of Pulverized Coal at Coal Nozzle with Coal Separator)

  • 김혁제;송시홍;이건명;김상현;이익형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.764-769
    • /
    • 2001
  • Recently, according to increase in the requirement of electric power, a thermoelectric power plant equipped with pulverized coal combustion system is highly valued, because coal has abundant deposits and a low price compared with others. For efficient use of coal fuel, most of plant makers are studying to improve combustion performance and flame stability, and reduce pollutant emission. One of these studies is how to control the profile of particle injection and velocity dependant on coal nozzle. Basically, a mixed flow of gas and particle in coal nozzle is required to have appropriate injection and concentration distribution at exit to achieve flame stability and low pollutant, but it is very difficult to obtain that without help of a coal separating device within nozzle. In this study, each distribution of air and coal flow rate is measured for the coal nozzle with coal separator developed by us. The coal concentration at exit is various according to inlet swirl values and positions of coal separator. Also pressure drop is measured for various operating conditions of this nozzle. From these results, we can find the separation characteristic of new developed coal separator, and select proper operation range of coal nozzle. When this coal nozzle is applied to actual plant, these investigations will be very useful to confirm the shape of coal separator to have efficient particle injection.

  • PDF

고전력 활선 XLPE 케이블의 열화를 측정하기 위한 판정기준의 적용 및 절연상태 판정 (Application of Judgement Criteria to Measure Deterioration and to Judge Insulation Resistance in High-Power Live XLPE Cables)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권2호
    • /
    • pp.239-244
    • /
    • 2017
  • 전력 수요는 매년 증가추세에 있으며, 이에 따라 발전소에서 동작하는 모든 장비들과 대용량의 장거리 전력수송을 위한 장비들은 신뢰할 수 있는 수준에서 완전한 상태로 동작하여야 한다. 발전소에서 생산한 고전압 전력을 전달하기 위해 사용하는 케이블은 주로 6.6 kV XLPE 케이블(또는 CV케이블)이다. 제작 기술, 설치환경 및 사용조건에 다르겠지만, 케이블은 동작함과 동시에 열화과정이 진행된다. 접속재의 경우, 제조 결함이나 공사 결함이 있는 경우 대체로 동작 후 약 3 년 내에 고장을 일으키며, 그렇지 않는 경우 수명이 20-30 년을 지속하는 경우가 많다. 우리는 케이블의 열화 상태를 감시하기 위한 장비를 개발하여 충남 태안의 한국서부발전주식회사(Korea Western Power Co. Ltd.)에 설치하였다. 우리는 이 논문에서 케이블의 열화 판정의 기준을 설정하고, 기준에 따른 열화정도를 판정하고, 케이블의 대체여부를 결정함으로써 발전소에서 설치된 활선 케이블의 동작 상태를 감시한 결과와 케이블을 구성하고 있는 절연체와 방식층이 절연저항 특성에 미치는 영향 및 케이블의 동작에 미치는 영향을 연구한 결과를 제시한다.

Evaluation of a betavoltaic energy converter supporting scalable modular structure

  • Kang, Taewook;Kim, Jinjoo;Park, Seongmo;Son, Kwangjae;Park, Kyunghwan;Lee, Jaejin;Kang, Sungweon;Choi, Byoung-Gun
    • ETRI Journal
    • /
    • 제41권2호
    • /
    • pp.254-261
    • /
    • 2019
  • Distinct from conventional energy-harvesting (EH) technologies, such as the use of photovoltaic, piezoelectric, and thermoelectric effects, betavoltaic energy conversion can consistently generate uniform electric power, independent of environmental variations, and provide a constant output of high DC voltage, even under conditions of ultra-low-power EH. It can also dramatically reduce the energy loss incurred in the processes of voltage boosting and regulation. This study realized betavoltaic cells comprised of p-i-n junctions based on silicon carbide, fabricated through a customized semiconductor recipe, and a Ni foil plated with a Ni-63 radioisotope. The betavoltaic energy converter (BEC) includes an array of 16 parallel-connected betavoltaic cells. Experimental results demonstrate that the series and parallel connections of two BECs result in an open-circuit voltage $V_{oc}$ of 3.06 V with a short-circuit current $I_{sc}$ of 48.5 nA, and a $V_{oc}$ of 1.50 V with an $I_{sc}$ of 92.6 nA, respectively. The capacitor charging efficiency in terms of the current generated from the two series-connected BECs was measured to be approximately 90.7%.

바이오 시료의 적정온도 사이클 유지를 위한 채널형 히트싱크에 대한 실험적 연구 (Experimental Study on the Channel Type Heat Sink to Maintain Proper Temperature Cycle of Bio-Sample)

  • 황정규;박상희
    • 한국산업융합학회 논문집
    • /
    • 제26권1호
    • /
    • pp.183-191
    • /
    • 2023
  • This study was conducted experimentally to investigate the surface temperature of the heat sink, the air temperature in the flow channel and the sample temperature by changing the channel number of channel type heat sink and the air flow rate when heating and cooling the bio sample. The target temperature of the sample was 15℃ or less as the minimum value and 82℃ or more as the maximum value. In this study, the channel number of the heat sink(N = 1, 2, 4, 5, 10) and the air flow rate(Q=25, 42, 54m3/min) were varied. The bio sample was replaced with water, and the volume of water is 4mL. The size of the heat sink is 80x73x150mm and the material is aluminum. When cooling the sample, the surface temperature, the air temperature and the sample temperature were highly dependent on the number of channels and the flow rate. However, when the sample is heated, the surface temperature, air temperature and sample temperature do not depend on the number of channels and the flow rate. It was found that the conditions for satisfying the minimum temperature of 15℃ or less when cooling the sample were the number of channels N≥5 and the flow rate Q≥42m3/min. When heating the sample, the conditions to satisfy the maximum temperature of 82℃ or more are the number of channels N≤5 and the air flow rate Q≤42m3/min.

화력발전소 고전력 케이블의 누설 전류 측정 데이터의 표준 편차값을 사용한 절연감시 데이터 분석 (Analysis of Monitored Insulation Data Using Standard Deviation of Leakage Current Data in High-Power Cables at a Thermoelectric Power Station)

  • 김보경;엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권2호
    • /
    • pp.245-250
    • /
    • 2017
  • 케이블은 설치하여 동작함과 동시에 열화과정이 진행된다. 고압전력케이블 시스템에 있어, 케이블의 절연층 및 방식층의 절연상태뿐만 아니라 케이블을 연결하는 단말부 및 접속부의 절연상태도 함께 감시하여야 케이블 시스템의 절연상태를 종합 관리할 수 있다. 케이블 시스템(케이블 자체 및 접속재)의 상태가 계속 나빠지는 경우, XLPE의 절연 파괴현상으로 인한 화재가 발생한다. 우리는 케이블시스템의 절연 상태를 감시하기 위한 장비를 개발하여 충남 태안의 한국 서부발전주식회사(Korea Western Power Co. Ltd.)에 설치하였다. 이 논문에서, 이 장비를 사용하여 케이블에 흐르는 누설전류를 추출하여 누설전류의 표준편차를 계산하여 분석한 결과를 제시한다. 정해진 누설 전류의 표준 편차값이 기준값 미만이면 안전하지만. 그 이상이면 케이블시스템의 단말부 및 접속부의 절연상태가 나쁜 것으로 판단하고, 새로운 케이블시스템의 단말부 및 접속부로 대체함으로써 전력공급 중단으로 인한 전력설비의 중단사고를 미연에 방지할 수 있다.