• 제목/요약/키워드: thermo sensor

검색결과 65건 처리시간 0.02초

Fiber-Optic Temperature Sensor Based on Single Mode Fused Fiber Coupler

  • Kim, Kwang-Taek;Park, Kiu-Ha
    • Journal of the Optical Society of Korea
    • /
    • 제12권3호
    • /
    • pp.152-156
    • /
    • 2008
  • This paper reports a fiber-optic temperature sensor using a single mode fused fiber coupler incorporating a thermo-optic external medium. The spectral transmission was altered by changing the refractive index of the external thermo-optic medium. A theoretical and experimental investigation was carried out with the aim of achieving high sensitivity. The measured sensitivity for the environmental temperature was as high as -1.5 $nm/^{\circ}C$.

Measurement of Thermo-Optic Coefficient of a Liquid Using a Cascade of Two Different Fiber Bragg Gratings

  • Kim, Kwang Taek;Kim, In Soo
    • 센서학회지
    • /
    • 제22권2호
    • /
    • pp.95-99
    • /
    • 2013
  • We proposed and demonstrated a fiber optic sensor for detecting the thermo-optic coefficient of a liquid, based on a cascade of two different FBGs. One of the two FBGs was etched, and its cladding was removed, for evanescent wave coupling with an external liquid. The Bragg wavelength of the non-etched FBG was used as a reference for the temperature of the surrounding liquid. The refractive index (RI) and thermo-optic (T-O) coefficient of a liquid can be detected from the difference between the Bragg wavelengths of the two FBGs, and the variation of the difference in accordance with temperature.

Development and Evaluation of Non-Hydrous Skin Analogue Liquid Crystal using Thermo-Sensitivity Smart Sensor

  • Yoo, Kwang-Ho;Hong, Jae-Hwa;Eun, So-Hee;Jeong, Tae-Hwa;Jeong, Kwan-Young
    • 한국응용과학기술학회지
    • /
    • 제31권3호
    • /
    • pp.367-374
    • /
    • 2014
  • In this study, skin permeation enhancement was confirmed by designing it to have a structure and composition similarity to the intercellular lipids that improve miscibility with skin by cross-linked lipids poloxamer. The cross-linked lipids poloxamer was synthesized and analyzed by 1H NMR that structure dose had conjugated pluronic with ceramide3. Active component is released by modification of liquid crystal structure because PPO part, large-scale molecule block of pluronic, has hydrophobic nature at skin temperature of $35^{\circ}C$. Conjugated pluronic with ceramide3 was synthesized using Pluronic F127 and p-NPC (4-nitrophenyl chloroformate) at room temperature yielded 89%. Pluronic(Ceramide 3-conjugated Pluronic) was synthesized by reaction of p-NP-Pluronic with Ceramide3 and DMAP. The yield was 51%. This cross-linked lipids poloxamer was blended and dissolved at isotropic state with skin surface lipids, phospholipid, ceramide, cholesterol and anhydrous additive solvent. Next step was preceded by ${\alpha}$-Transition at low temperature for making the structure of Meso-Phase Lamella, and non-hydrous skin analogue liquid crystal using thermo-sensitivity smart sensor, lamellar liquid crystal structure through aging time. For confirmation of conjugation thermo-sensitivity smart sensor and non-hydrous skin analogue liquid crystal, structural observation and stability test were performed using XRD(Xray Diffraction), DSC(Differential Scanning Calorimetry), PM (Polarized Microscope) And C-SEM (Cryo-Scanning Electron Microscope). Thermo-sensitivity observation by Franz cell revealed that synthesized smart sensor shown skin permeation effect over 75% than normal liquid crystal. Furthermore, normal non-hydrous skin analogue liquid crystal that not applied smart sensor shown similar results below $35^{\circ}C$ of skin temperature, but its effects has increased more than 30% above $35^{\circ}C$.

고응답 열식 질량공기유량센서의 제작 및 열거동 특성 (Micro-Fabrication and Thermal Characteristics of a Thermal Mass Air Flow Sensor for Real-time Applications)

  • 박병규;이준식
    • 대한기계학회논문집B
    • /
    • 제32권7호
    • /
    • pp.542-548
    • /
    • 2008
  • A thermal mass air flow sensor (MAFS), which consists of a micro-heater and thermo-resistive sensors on the silicon-nitride ($Si_3N_4$) thin membrane structure, is micro-fabricated by MEMS processes. Two thermo-resistive temperature sensors are located at $100{\mu}m$ upstream and downstream from the micro-heater respectively. The thermal characteristics are measured to find the best measurement indicator. The micro-heater is operated under constant power condition, and four flow indicators are investigated. The normalized temperature indicator shows good physical meaning and is easy to use in practice. It is found that the configurations and heating power of thermal-resistive elements are the dominant factors to determine the range of the flow measurement in the MAFS with higher sensitivity and accuracy.

Thermo-optic Effects of Bragg Grating Optical Temperature Sensor

  • Ahn, Kook-Chan;Lee, Sang-Mae;Lee, Gwang-Seok;Park, Seung-Bum
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제3권2호
    • /
    • pp.24-30
    • /
    • 2002
  • This paper demonstrates a comparison of linear and nonlinear analyses for thermo-optic effects of optical temperature sensor based on the etched silica-based planar waveguide Bragg grating. Topics include theoretical analyses and experiment of the etched planar waveguide Bragg grating optical temperature sensor. Theoretical models with nonlinear than linear temperature effect for the grating response based on waveguide and plate deformation theories agree with experiments to within acceptable tolerance.

식각된 열확산 코어 광섬유를 이용한 고감도 온도 센서 (Highly sensitive temperature sensor based on etched fiber with thermally expanded core)

  • 김광택;송현석;신은수;홍기범
    • 센서학회지
    • /
    • 제15권4호
    • /
    • pp.263-268
    • /
    • 2006
  • We have demonstrated a highly sensitive temperature sensor using an etched single mode fiber with a thermally expanded core region. Large core size of thermally expanded core facilitates access to evanescent wave by the wet etching. The etched region was surrounded by a low dispersive external medium with high thermo-optic coefficient. Due to the large difference between the dispersion property of the fiber and that of the external medium, the device reveals a cut-off properties at spectral region. The cut-off wavelength was shifted by the variations of the environmental temperatures because of thermo-optic effect of the external medium. The sensitivity of the fabricated device was found to be $45nm/^{\circ}C$.

광 온도센서의 열전.광 효과 (Thermo-optic Effects of Optical Temperature Sensor)

  • 이광석;김현덕
    • 한국정보통신학회논문지
    • /
    • 제10권11호
    • /
    • pp.2049-2054
    • /
    • 2006
  • 본 연구는 에칭된 실리카 기반의 평면 도파로 Bragg grating에 기반한 광 온도센서의 열전 광 효과에 대한 선형 및 비선형 해석에 대하여 제시하였다. 또한, 에칭된 평면 도파로 Bragg grating 광 온도센서의 이론적인 해석과 실험을 행하고 그 결과를 나타내었다. 도파로에 기반한 grating응답에 대하여 선형 온도 효과보다 비선형의 이론적 모델과 plate deformation이론이 허용오차 범위 내에서의 실험치와 일치함을 알 수 있었다.

Thermo-tracer를 이용한 온실의 열환경 분석 (Thermal environment analysis of greenhouse using Thermo-tracer)

  • 이석건;이종원;이현우;김란숙
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.230-236
    • /
    • 1998
  • Thermal environment of greenhouse was investigated by thermo-tracer in this study. The Thermo-tracer is a high-sensitivity infrared thermometer of non-contact type. The infrared energy emitted from the measured object is converted into an electrical signal by the detector(HgCdTe) and display as a color or black & white thermal image by way of optical scanning, The experiment was conducted for Venlo-type greenhouse with pad & fan system. The temperature difference between measured by Thermo-trace and measured by HOBO sensor is maximum 0.8$^{\circ}C$. Thermo-trace is possible to use for the thermal environment analysis and diagnosis of a cooling and heating system of greenhouse.

  • PDF

측면 연마 광섬유와 결합된 상부 도파로의 클래딩을 이용한 편광 무의존 온도센서 (Polarization-independent temperature sensor using cladding layers of the overlay waveguide coupled with a side-polished fiber)

  • 손경락;김광택;송재원
    • 한국광학회지
    • /
    • 제13권6호
    • /
    • pp.467-472
    • /
    • 2002
  • 본 논문에서는 측면연마 광섬유 결합기 구조에서 평면 도파로의 상부와 하부 클래딩의 열광학 효과를 이용하여 온도를 측정할 수 있는 편광 무의존 온도 센서를 제안하고 있다. 평면 도파로는 170$\mu\textrm{m}$ 두께의 현미경용 덮게 유리를 적용함으로서 급격한 온도 변화에 대해 도파로의 변형이 발생하지 않고, 비대칭적 평면 도파로 구조로 인한 편광 의존 손실을 최소화하기 시킬 수 있는 장점을 가진다. 제작된 소자의 편광 의존 손실은 0.3dB 이하로 측정되었다. 피측정체의 온도는 센서의 결합 파장 이동으로부터 계측되어진다. 평면 도파로의 상부와 하부 클래딩의 열광학 계수에 따른 온도 센서의 온도 민감도를 측정하였고, 상ㆍ하부 클래딩의 열광학 계수 변화로 온도 민감도를 제어할 수 있음을 보였다.

Thermo-optic Characteristics of Micro-structured Optical Fiber Infiltrated with Mixture Liquids

  • Wang, Ran;Wang, Yuye;Miao, Yinping;Lu, Ying;Luan, Nannan;Hao, Congjing;Duan, Liangcheng;Yuan, Cai;Yao, Jianquan
    • Journal of the Optical Society of Korea
    • /
    • 제17권3호
    • /
    • pp.231-236
    • /
    • 2013
  • We present both theoretically and experimentally the thermo-optic characteristics of micro-structured optical fiber (MOF) filled with mixed liquid. The performance of MOF depends on the efficient interaction between the fundamental mode of the transmitted light wave and the tunable thermo-optic materials in the cladding. The numerical simulation indicates that the confinement loss of MOF presents higher temperature dependence with higher air-filling ratios $d/{\Lambda}$, longer incident wavelength and fewer air holes in the cladding. For the 4cm liquid-filled grapefruit MOF, we demonstrate from experiments that different proportions of solutions lead to tunable temperature sensitive ranges. The insertion loss and the extinction ratio are 3~4 dB and approximate 20 dB, respectively. The proposed liquid-filling MOF will be developed as thermo-optic sensor, attenuator or optical switch with the advantages of simple structure, compact configuration and easy fabrication.