• 제목/요약/키워드: thermistor

검색결과 220건 처리시간 0.024초

RF/DC 마그네트론 스퍼터법을 이용한 $BaTiO_3$계 세라믹 박막의 제조와 PTC특성 (Preparation and PTC properties of thin films $BaTiO_3$ ceramic system using RF/DC magnetron sputtering method)

  • 박춘배;송민종;김태완;강도열
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권1호
    • /
    • pp.77-82
    • /
    • 1995
  • PTCR(Positive Temperature Coefficient of Resistivity) thermistor in thin film BaTiO$_{3}$ system was prepared by using radio frequency(13.56 MHz) and DC magnetron sputter equipment. Polycrystalline, surface structure, and R-T(Resistivity-Temperature) characteristics of the specimens were measured by X-ray diffraction(D-Max3, Rigaku, Japan), SEM(Scanning Electron Microscopy: M.JSM84 01, Japan), and insulation resistance measuring system (Keithley 719), respectively. Thin films characteristics of the thermistor showed different properties depending on the substrate even with the same sputtering condition. The thin film formed on the A1$_{2}$O$_{3}$ substrate showed a good crystalline and a low resistivity at below curie point. However, the thin films prepared on slide glass and Si wafer were amorphous. The thicknesses of the three samples prepared under the same process conditions were 700[.angs.], 637.75[.angs.], and 715[.angs.], respectively.

  • PDF

Ca 첨가가 PTCR 써미스터의 전기적 특성에 미치는 영향 (The Effects of Ca Addition on Electrical Properties of PTCR Thermistor)

  • 김병수;김종택;김철수;김용혁;이덕출
    • 한국전기전자재료학회논문지
    • /
    • 제11권2호
    • /
    • pp.121-127
    • /
    • 1998
  • In this paper, to develop PTCR(Positive Temperature Coefficient of Resistance) thermistor with high withstanding voltage, Ca were added to. the compositions of $(Ba_{0.9165-X}-Sr_{0.08}-Ca_X-Y_{0.0035})TiO_3+MnO_2$ 0.02wt%+$SiO_2$ 0.5wt%. the effects of Ca additions were researched according the increasing of Ca from 0[mol%] to 20[mol%], and the electrical properties were investigated. As increasing Ca additions from 0[mol%] to 20[mol%], the grain size of the specimens was reduced from 11.1[${\mu}m$] to 6.15[${\mu}m$], and also the sintered density was reduced from 5.43[$g/cm^3$] to 5.05[$g/cm^3$] and their the breakdown voltages were increased from 163[V/mm] to 232[V/mm]. It is shown that the breakdown voltage was increased with amount of Ca additions.

  • PDF

광도전성저항을 이용한 열선유속계의 하드웨어적 온도보상에 관한 연구 (Hardware temperature compensation technique for hot-wire anemometer by using photoconductive cell)

  • 이신표;고상근
    • 대한기계학회논문집B
    • /
    • 제20권11호
    • /
    • pp.3666-3675
    • /
    • 1996
  • A new hardware temperature compensation method for hot-wire anemometer is investigated and an analog compensating circuit is proposed in this article. A photoconductive cell is introduced here as a variable resistor in the anemometer bridge and the linearized output of a thermistor is used to monitor the input of the photoconductive cell. In contrast with the conventional method, any type of temperature sensor can be used for compensation if once the output of thermometer varies linearly with temperature. So the present technique can diversify the compensating means from a conventional passive compensating resistance to currently available thermometers. Because the resistance of a photoconductive cell can be set precisely by adopting a stabilizing circuit whose operation is based on the integration function of the operational amplifier, the accuracy of compensation can be enhanced. As an example of linearized thermometer, thermistor sensor whose output is linearized by a series resistor was used to monitor the fluid temperature variation. Validation experiment is conducted in the temperature ranged from 30 deg. C to 60 deg. C and the velocity up to 40 m/s. It is found that the present technique can be adopted as a compensating circuit for anemometer and hot-wire type airflow meter.

Thermal Property Measurement of Swine Atrium

  • ;김지연
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권5호
    • /
    • pp.343-347
    • /
    • 2008
  • Thermal conductivity, thermal diffusivity were measured in the atrium of a swine heart. Radiofrequency (RF) catheter ablation in an atrium has rapidly emerged at the treatment of symptomatic reentrant arrhythmia associated with accessory pathway or Atrioventricular (AV) node conduction. The thermal properties of an atrium are definitely necessary for these treatments because, in thermal treatments, conductivity and diffusivity are significant factors in the relationship between the applied RF power and the resulting atrium temperature rise. Thermal properties were measured using a self-heated thermistor probe. Thermistor probes were inserted into the tissue of interest and were used to supply heat within the tissue as well as to monitor the temperature rise in the tissue. The measurements were performed at temperatures of 25, 37, $50^{\circ}C$. Atrium thermal conductivity ranged from 5.17$\pm$0.12 mW/cm$^{\circ}C$ at $25^{\circ}C$ to 5.33$\pm$0.08 mW/cm$^{\circ}C$ at $37^{\circ}C$. Atrium thermal diffusivity ranged from 0.00132$\pm$0.00007$cm^2$/sec at $25^{\circ}C$ to 0.00138$\pm$0.00003 $cm^2$/sec at $50^{\circ}C$. This paper also present the thermal property comparison of both chambers of a heart (ventricle and atria).

Fabrication of SMD Type PTC Thermistor with Multilayer Structure

  • Kim, Yong-Hyuk;Lee, Duck-Cuool
    • 센서학회지
    • /
    • 제9권1호
    • /
    • pp.76-82
    • /
    • 2000
  • 본 연구에서는 내부전극 접합기술을 이용하여 적층구조의 PTC 서미스터를 제작하였다. 적층구조 PTC 서미스터는 저항, 소형, 대전류 등의 특징을 갖는다. PTC 특성을 조사하기 위하여 첨가제효과, 전압-전류특성, 온도특성, 복합임피던스 특성 등을 측정하였다. 적층구조 PTC서미스터는 저항의 온도특성과 전압-전류특성에서 높은 비선형성을 나타내었다. 적층수가 증가함에 따라 상온저항이 감소되는 특성이 결정립의 효과에 기인됨을 알았다. 전류의 스윗칭 변화는 적층구조가 갖는 열용량의 크기에 비례하였으며, 적층수가 증가할수록 스윗칭 시간이 증가하였다.

  • PDF

이동통신 단말기에 이용되는 적층 칩 써미스터 제작 (The Fabrication of Mulilayer Chip NTC Thermistor for Mobile Communication Telephone)

  • 윤중락;이헌응;김지균;이석원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1794-1796
    • /
    • 2000
  • Oxides of the form $Mn_{3}O_4$-$Co_{3}O_4$-NiO present properties that make them useful as multilayer chip NTC thermistor for mobile communication telephone. When $Mn_{2}Ni_{x}CO_{1-x}O_4$ composition with the X = 0.12$\sim$0.24 at sintered temperature 1250$^{\circ}C$, resistivity and B-constant were 300$\sim$450[${\Omega}-cm$] and 3250$\sim$3450, respectively. Multilayer chip NTC(Negative Temperature Coefficient) resistor were fabricated with 4 layer by a conventional multilayer capacitor techniques, using 100 pd paste as internal electrode and $Mn_{2}Ni_{0.20}CO_{0.8}O_4$ composition as NTC materials. In particular, resistance change ratio (${\Delta}R$), the important factor for reliability, varied within $\pm$3%, indicating the compositions of multilayer chip NTC thermistor products could be available for mobile communication telephone.

  • PDF

$BaTiO_{3}$ PTC 서미스터 입계의 전기적인 특성 (The Electrical Characteristics of the Grain Boundary in a $BaTiO_{3}$ PTC Thermistor)

  • 권혁주;이재성;이용수;이동기;이용현
    • 센서학회지
    • /
    • 제1권1호
    • /
    • pp.67-75
    • /
    • 1992
  • $BaTiO_{3}$ PTC 서미스터를 제조하여 그 전기적 특성을 조사하였다. PTC 서미스터의 저항률은 $20^{\circ}C$에서 $200^{\circ}C$까지 $20^{\circ}C$ 간격으로 측정되었다. 이 시편의 ac 복소 임피던스 분석을 통하여 PTC 서미스터의 입계저항, 입계정전용량, bulk 저항 등을 조사하였다. 전자현미경을 사용하여 grain을 확인하고 평균 입경을 구하였으며 측정된 평균 입경은 $3.8{\mu}m$에서 $8.8{\mu}m$까지 되었다. 평균 입경은 소결온도가 높을수록 커지는 경향을 보였으며 최대저항률 증가비는 $4{\times}10^{5}$ 정도였다. Bulk 저항률은 소결온도가 $1340^{\circ}C$ 이상일 경우는 측정온도가 증가함에 따라 감소하였다. 측정온도가 증가할수록 입계저항은 n의 지수함수적으로 증가하였으며, 입계정전용량은 감소하고, 입계의 전위 장벽은 증가하였다. 입계전하밀도는 측정온도가 올라갈수록 증가하였으나, 측정온도가 약 $110^{\circ}C$ 이상일 경우 더 이상 증가하지 않았다.

  • PDF

수면무호흡증과 상기도저항 증후군에서 Nasal Airflow의 압력측정 및 상기도 압력변화에 대한 연구 (The Nasal Airflow Pressure Monitoring and the Measurement of Airway Pressure Changes in Obstructive Sleep Apnea Syndrome and Upper Airway Resistance Syndrome)

  • 김후원;홍승봉
    • 수면정신생리
    • /
    • 제7권1호
    • /
    • pp.27-33
    • /
    • 2000
  • 수면 중 나타나는 호흡장애를 좀 더 정확하게 측정하기 위해 고안된 비강 공기압 측정기의 민감도를 온도감지 센서와 비교하기 위해 30명의 수면무호흡 증후군 환자와 6명의 상기도 저항증후군 환자에서 저호흡-무호흡 지수와 각성지수를 비교하였다. 그리고 상기도 저항 증후군에서 각성을 일으키는 상기도 압력변화에 대해 알아보기 위하여 온도감지 센서에서 발견되지 않은 저호흡-무호흡과 관련된 각성에서 상기도의 압력을 측정하였다. 비강 공기압 측정기가 기존의 온도감지 센서보다 훨씬 더 민감한 방법임을 알 수 있었다(p<0.05). 비강 공기압 측정기로 검사하여 저호흡-무호흡지수가 평균 41%가 증가되었고 호흡장애가 심하지 않은 경증의 수면무호흡 증후군이나 상기도 저항 증후군에서 더 많이 증가하였다. 비강 공기압 측정기로 검사한 저호흡-무호흡지수를 비교하면 상기도 저항 증후군이 수면무호흡 증후군의 가장 경미한 형태라는 것을 알 수 있었다. 상기도 저항 증후군에서 나타나는 각성에서 상기도의 압력 변화는 일정한 범위에서 나타나지 않았고 다양한 압력 분포를 보였으며 수면 중 호흡장애의 정도가 심해질수록 압력변화의 폭이 더 커지는 양상을 보였다. 비강 공기압 측정기가 기존의 온도감지 센서보다 더 민감하지만 아직까지 해결해야 할 문제가 일부 남아 있어서 온도 감지 센서를 완전히 대체하기는 어려울 것으로 보인다. 그러나 경증의 수면무호흡 증후군이나 상기도 저항 증후군을 진단하는 데에는 많은 도움이 될 것이다. 특히 상기도 저항 증후군의 진단에 기존에는 상기도 압력 측정이 필요하다고 하였으나 비강 공기압 측정기를 이용하면 불편한 상기도 압력 측정은 필요 없을 것으로 생각된다.

  • PDF