• 제목/요약/키워드: thermal degradation temperature

검색결과 576건 처리시간 0.022초

Biodegradable PLA-based Biocomposites with Spent Coffee Grounds as Degradation Accelerator: Hydrolytic Degradation and Characterization Research

  • Kim, Youngsan;Lim, Daekyu;Kwon, Sangwoo;Jang, Hyunho;Park, Su-il
    • 한국포장학회지
    • /
    • 제28권2호
    • /
    • pp.89-95
    • /
    • 2022
  • The goal of this study was to evaluate the effect of spent coffee grounds (SCG) biofiller on the morphological, thermal, mechanical and hydrolytic degradation characteristics of poly(lactic acid) (PLA) based biocomposites. The PLA-based biocomposite films were fabricated by using a high-viscosity kneading and hot-pressing machine. The PLA/SCG biocomposites were analyzed with SEM, DSC, TGA, UTM and hydrolytic degradation test. Aggregation in the PLA matrix is a result of increasing SCG concentrations. In the thermal properties, it was described that the cold crystallization temperature (Tcc) decreased as SCG was added to PLA. When SCG was incorporated to PLA, the degradation onset temperature (Tonset) revealed a diminish. The elastic modulus increased while tensile strength of PLA diminished as SCG was applied. Through hydrolysis analysis, the decomposition of PLA was accelerated with the addition of SCG. This research confirmed the possibility of devloping an eco-friendly packaging material with high degradability as SCG hasten the breakdown of PLA.

A comprehensive study of the effects of long-term thermal aging on the fracture resistance of cast austenitic stainless steels

  • Collins, David A.;Carter, Emily L.;Lach, Timothy G.;Byun, Thak Sang
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.709-731
    • /
    • 2022
  • Loss of fracture resistance due to thermal aging degradation is a potential limiting factor affecting the long-term (80+ year) viability of nuclear reactors. To evaluate the effects of decades of aging in a practical time frame, accelerated aging must be employed prior to mechanical characterization. In this study, a variety of chemically and microstructurally diverse austenitic stainless steels were aged between 0 and 30,000 h at 290-400 ℃ to simulate 0-80+ years of operation. Over 600 static fracture tests were carried out between room temperature and 400 ℃. The results presented include selected J-R curves of each material as well as K0.2mm fracture toughness values mapped against aging condition and ferrite content in order to display any trends related to those variables. Results regarding differences in processing, optimal ferrite content under light aging, and the relationship between test temperature and Mo content were observed. Overall, it was found that both the ferrite volume fraction and molybdenum content had significant effects on thermal degradation susceptibility. It was determined that materials with >25 vol% ferrite are unlikely to be viable for 80 years, particularly if they have high Mo contents (>2 wt%), while materials less than 15 vol% ferrite are viable regardless of Mo content.

플랜트 부품용 상용 발수코팅의 고온 환경 고장 특성 비교 분석 (Failure Analysis of Commercial Water-Repellent Coatings for High Temperature Plant)

  • 이병호;김혜영;현창용;변재원
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제17권1호
    • /
    • pp.78-82
    • /
    • 2017
  • Purpose: The purpose of this study is to evaluate failure characteristic and mechanism of four commercial water-repellent coatings for elevated temperature machinery applications. Method: Thermal degradation was performed for up to 64 thermal cycles. 1 cycle consists of 15 minute holding at 523K under 300rpm revolution and 15 minute-natural cooling. Contact angle was measured and microstructure of the coating layer was observed by using a scanning electron microscope. Results: Four kinds of commercial repellent coating showed hydrophobic or super-hydrophobic property implying that all coatings are suitable for room temperature application. Contact angle of three kinds of commercial coatings decreased rapidly after thermal exposure, while only one specimen having hydrophobic surface showed extremely slow degradation. Conclusion: Observed decrease in contact angle of the coatings were attributed to formation of macro-sized pores and disappearance of micro-protrusion during thermal exposure. Optimum water-repellent coating needs to be selected under the consideration of initial contact angle as sell as service temperature.

하절기 차열성능을 갖는 방수재의 적용에 따른 건축물 표면온도 변화추이 연구 (A Study on the Surface Temperature Change of Building Applied with Thermal Insulation Waterproofing Material During Summer)

  • 김동범;박진상;최수영;박재홍;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.45-46
    • /
    • 2017
  • As the environment and energy problems such as global climate change (global warming, urban heat island phenomenon) and energy depletion have come to the fore, the construction and waterproofing industry are responding more critically to the demands of global green technology and are employing more eco-friendly technologies as of recent. In this study, the application of the waterproofing material with thermal response performance in construction buildings was investigated to confirm whether the thermal performance is being properly secured by the change of the surface temperature. Experimental results showed that the surface temperature difference between before and after the application is at least 19.8℃ at the maximum 26.3℃. When the degradation rate is converted, the degradation effect of about 40% on average was confirmed.

  • PDF

적외선 열화상 카메라를 이용한 수전설비 온도분포해석 (The Analysis of Temperature Distribution Electric incoming Apparatus Using a Infrared Thermal Imaging System)

  • 정승천;임용배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1113-1116
    • /
    • 2004
  • This paper presents the method for analyzing surface temperature of Electric incoming Apparatus. For the experiment, the surface temperature of electric power apparatus was measured and analyzed by using a infrared thermal imaging system. Surface Discharges(SD) have very complex characteristics of discharge patterns, therefore it requires the development of precise analysis methods. recently, studies on infrared thermal imaging system are carried out to analyze temperature distribution of power equipments through condition diagnosis and to diagnose the degradation of power equipments. The changes in suface temperature was measured by using the infrared thermal imaging system under hot line condition. The system was set up based on the diagnostic method of the electric incoming apparatus.

  • PDF

Inter-lamina Shear Strength of MWNT-reinforced Thin-Ply CFRP under LEO Space Environment

  • Moon, Jin Bum;Kim, Chun-Gon
    • Composites Research
    • /
    • 제30권1호
    • /
    • pp.7-14
    • /
    • 2017
  • In this paper, the inter-lamina shear strength (ILSS) of multi-wall carbon nanotube (MWNT) reinforced carbon fiber reinforced plastics (CFRP) and thin-ply composites were verified under low earth orbit (LEO) space environment. CFRP, MWNT reinforced CFRP, thin-ply CFRP and MWNT reinforced thin-ply CFRP were tested after aging by using accelerated ground simulation equipment. The used ground simulation equipment can simulate high vacuum ($2.5{\times}10^{-6}torr$), atomic oxygen (AO, $9.15{\times}10^{14}atoms/cm^2{\cdot}s$), ultraviolet light (UV, 200 nm wave length) and thermal cycling ($-70{\sim}100^{\circ}C$) simultaneously. The duration of aging experiment was twenty hours, which is an equivalent duration to that of STS-4 space shuttle condition. After the aging experiment, ILSS were measured at room temperature ($27^{\circ}C$), high temperature ($100^{\circ}C$) and low temperature ($-100^{\circ}C$) to verify the effect of operation temperature. The MWNT and thin-ply shows good improvement of ILSS at ground condition especially with the thin-ply. And after LEO exposure large degradation of ILSS was observed at MWNT added composite due to the thermal cycle. And the degradation rate was much higher under the high temperature condition. But, at the low temperature condition, the ILSS was largely recovered due to the matrix toughening effect.

액체질소에서의 극저온 절연매질의 Warm-up/Cool-down 특성 (Warm-up and Cool-down Characteristics of Cryogenic Insulation Materials in Liquid Nitrogen)

  • 이상화;신우주;;오석호;성재규;이방욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.119-119
    • /
    • 2010
  • Among the various factors influencing the service life of the electric equipment, the performance of dielectric insulation materials has an important role to determine their whole service life. In order to determine the degradation of insulating materials immersed in extremely low temperature media such as liquid nitrogen, the abrupt temperature change from cryogenic to normal room temperature should be considered. But the assessments of low-temperature aging test method for the dielectric materials immersed in liquid nitrogen considering these conditions were not fully reported. Therefore, for the fundamental step to establish the suitable degradation test methods for cryogenic dielectric materials, we focused on the evaluation of ageing test methods for dielectric materials exposed to low temperature environments considering thermal shock by cool-down and warm up test.

  • PDF

전기적 접속/접촉부 열화 평가를 위한 수명 온도상승 모델 (Lifetime-Temperature Rise Model for the Evaluation of Degradation in Electric Connections/Contacts)

  • 김정태;김남준
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권2호
    • /
    • pp.55-61
    • /
    • 2002
  • In this paper, 'lifetime-temperature rise model' based on the 'lifetime-resistance model' is theoretically Proposed, in order to find out the evaluation method of degradation and the residual lifetime by use of infrared image camera for electric connections/contacts. Two assumptions have been builded up for the 'lifetime-temperature rise model': one is associated with the linear relationship between the temperature ism ΔK and contact resistance, and the other the functional relationship between the temperature of electric connections/contacts and the operating time presenting in the 'lifetime-resistance model'. To prove the proposed model, experiments have been performed for various electric connections/contacts. From the experimental results, measured values were quite similar to the calculated values, which proved the above-mentioned two assumptions. Therefore, by use of 'lifetime-temperature rise model', it is possible to estimate the trend of degradation and the residual lifetime for electric connections/contacts through the temperature measurements .

탄소나노튜브를 첨가한 나노 반도전층 재료의 기계적/열적 특성 변화 연구 (Mechanical and Thermal Properties Changes of Nano Semiconducting Materials due to Addition of Carbon Nanotubes)

  • 양종석;이경용;신동훈;최유진;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.28-29
    • /
    • 2006
  • To improve Mechanical and Thermal Properties of semiconducting materials in power cable, we have investigated those of semiconducting materials showed by changing the content of carbon black and Carbon Nanotube. Density were measured by EW-200SG. High temperature, heat degradation initiation temperature, and heat weight loss were measured by TGA (Thermogravimetric Analysis). The dimension of measurement temperature was $0[^{\circ}C]$ J to $700[^{\circ}C]$, and rising temperature was $10[^{\circ}C/min]$. Heat degradation initiation temperature from the TGA results was decreased according to increasing the content of Carbon Nanotube. That is, heat stabilities of EVA containing the weak VA (vinyl acetate) against heat was measured the lowest. From the results of the experiment applied in this study, it is evident that a small amount of Carbon nanotube additives significantly improved the Mechanical and Thermal Properties of semiconducting materials.

  • PDF

Formation Kinetic Study of Thermal Products of Tocopherols

  • Chung, Hae-Young
    • Preventive Nutrition and Food Science
    • /
    • 제12권3호
    • /
    • pp.131-134
    • /
    • 2007
  • The kinetic analyses for thermal products of alpha-, gamma- and delta-tocopherols during heating as functions of temperature and time were studied. Alpha-, gamma- and delta-tocopherols dissolved in glycerol were heated at $100{\sim}200^{\circ}C$ for $5{\sim}60$ min. The thermal products were separated by hexane extraction and analyzed by HPLC using a reversed phase ${\mu}-Bondapak$ $C_{18}-column$ with two kinds of elution solvents in a gradient mode. The formation kinetics of thermal products of tocopherols followed a first-order kinetic model. The formation rate of thermal products of tocopherols was dependent on heating temperatures and heating times. The activation energy and enthalpy for the thermal products of ${\gamma}-and$ ${\delta}-tocopherols$ were higher than those for ${\alpha}-tocopherol$ as in the case of the oxidative degradation kinetics of tocopherol. The magnitude order of the activation energy was ${\gamma}->{\delta}->{\alpha}-tocopherol$.