• 제목/요약/키워드: the Phase of Order

검색결과 6,122건 처리시간 0.034초

A 2nd Order Harmonic Compensation Method for Wind Power System Using a PR Controller

  • Jeong, Hae-Gwang;Lee, Jong-Hyun;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권3호
    • /
    • pp.507-515
    • /
    • 2013
  • This paper proposes a compensation method for the $2^{nd}$-order harmonic of single-phase grid-connected wind power generation systems. Theoretically, a single-phase grid-connected inverter system has no choice but to cause the $2^{nd}$-order harmonic to DC-link voltage. The reference active current is affected by the DC-link voltage. The output current from the reference active current is distorted by the $1^{st}$ and $3^{rd}$-order harmonic. The proposed method can compensate, conveniently, the reference active current with the $2^{nd}$-order harmonic. To reduce the $2^{nd}$-order ripple in the reference active current, proposed method takes a PR controller as a feed-forward compensator. PR controllers can implement selective harmonic compensation without excessive computational requirements; the use of these controllers simplifies the method. Both the simulation and experimental results agree well with the theoretical analysis.

레지스터 재활용 사슬의 체계적 생성 (A Systematic Generation of Register-Reuse Chains)

  • 이혁재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권12호
    • /
    • pp.1564-1574
    • /
    • 1999
  • In order to improve the efficiency of optimizing compilers, integration of register allocation and instruction scheduling has been extensively studied. One of the promising integration techniques is register allocation based on register-reuse chains. However, the generation of register-reuse chains in the previous approach was not completely systematic and consequently it creates unnecessarily dependencies that restrict instruction scheduling. This paper proposes a new register allocation technique based on a systematic generation of register-reuse chains. The first phase of the proposed technique is to generate register-reuse chains that are optimal in the sense that no additional dependencies are created. Thus, register allocation can be done without restricting instruction scheduling. For the case when the optimal register-reuse chains require more than available registers, the second phase reduces the number of required registers by merging the register-reuse chains. Chain merging always generates additional dependencies and consequently enforces the execution order of instructions. A heuristic is developed for the second phase in order to reduce additional dependencies created by merging chains. For matrix multiplication program, the number of registers resulting from the first phase is small enough to fit into available registers for most basic blocks. In addition, it is shown that the restriction to instruction scheduling is reduced by the proposed merging heuristic of the second phase.

  • PDF

정상분 전압 관측기를 이용한 불평형 3상 전원의 PLL (PLL for Unbalanced Three-Phase Utility Voltage using Positive Sequence Voltage Observer)

  • 김형수;최종우
    • 전력전자학회논문지
    • /
    • 제13권2호
    • /
    • pp.145-151
    • /
    • 2008
  • 본 논문에서는 계통 전압이 불평형인 경우에 정확한 위상각을 검출할 수 있는 정상분 전압 관측기를 이용한 PLL(Phase Locked Loop) 방법을 제안한다. 제안된 PLL 방법은 기존의 전역 통과 필터(APF, All Pass Filter)를 이용하여 불평형 전원전압으로부터 정상분 전압을 구하는 것과는 달리 전차원 상태관측기를 사용함으로써 불평형사고 발생 시 추정위상각의 과도상태 응답특성을 개선하였다. 기존의 정상분 전압 추출 PLL 방법과 본 논문에서 제안된 PLL 방법의 성능을 비교하기 위해, 전원단 전압에 불평형 사고 발생시 위상각을 검출하는 실험을 하였고, 이를 통해 기존의 전역 통과 필터를 이용한 정상분 전압 추출 PLL 방법보다 제안된 전차원 상태관측기를 이용한 정상분 전압 추출 PLL 방법의 과도상태 응답특성이 개선됨을 입증하였다.

Effect of rotation on Stoneley waves in orthotropic magneto-thermoelastic media

  • Parveen, Lata;Himanshi, Himanshi
    • Wind and Structures
    • /
    • 제35권6호
    • /
    • pp.395-403
    • /
    • 2022
  • The present research is concerned with the study of Stoneley wave propagation at the interface of two dissimilar homogeneous orthotropic magneto-thermoelastic solids with fractional order theory of type GN-III with three phase-lags and combined effect of hall current and rotation. With the help of appropriate boundary conditions the secular equations of Stoneley waves are obtained in the form of determinant. The characteristics of wave such as phase velocity, attenuation coefficient and specific loss are computed numerically. The effect of rotation on the Stoneley wave's phase velocity, attenuation coefficient, specific loss, displacement components, stress components and temperature change has been depicted graphically. Some particular cases are also derived in this problem.

가시광 InGaAsP/GaAs 결정성장을 위한 상평형도 해석 (An Analysis of the Phase Diagram fo the Crystal Growth of InGaAsP/GaAs in the Visible Region)

  • 홍창희;조호성;오종환;예병덕;황상구;배정철
    • 한국항해학회지
    • /
    • 제15권3호
    • /
    • pp.99-106
    • /
    • 1991
  • In order to grow InGaAsP epitaxial layer on GaAs by LPE, an accurate phase diagram for In-Ga-As-P quarternary compounds is required. But the short wavelength InGaAsP/GaAs phase diagram for full wavelength range was not yet reported. In this study, therefore, a theoretical calculation has been carried out by using thermodynamic's equation for InGaAsP/GaAs in order to get the relation between the mole fraction of the sloute and solid phase compounds. And the calculation being compared with the dta of Kawanishi et. al, the result has been shown that his phase diagram obtained by the calculation can apply to growing InGaAsP/GaAs by LPE.

  • PDF

Accurate Voltage Parameter Estimation for Grid Synchronization in Single-Phase Power Systems

  • Dai, Zhiyong;Lin, Hui;Tian, Yanjun;Yao, Wenli;Yin, Hang
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1067-1075
    • /
    • 2016
  • This paper presents an adaptive observer-based approach to estimate voltage parameters, including frequency, amplitude, and phase angle, for single-phase power systems. In contrast to most existing estimation methods of grid voltage parameters, in this study, grid voltage is treated as a dynamic system related to an unknown grid frequency. Based on adaptive observer theory, a full-order adaptive observer is proposed to estimate voltage parameters. A Lyapunov function-based argument is employed to ensure that the proposed estimation method of voltage parameters has zero steady-state error, even when frequency varies or phase angle jumps significantly. Meanwhile, a reduced-order adaptive observer is designed as the simplified version of the proposed full-order observer. Compared with the frequency-adaptive virtual flux estimation, the proposed adaptive observers exhibit better dynamic response to track the actual grid voltage frequency, amplitude, and phase angle. Simulations and experiments have been conducted to validate the effectiveness of the proposed observers.

유도 단계별 측방낙법의 운동학적 변인 비교분석[ I ] (A Kinematic Comparative Analysis of Yoko Ukemi(side breakfall) by Each Stage in Judo[ I ])

  • 김의환;김성섭
    • 한국운동역학회지
    • /
    • 제14권3호
    • /
    • pp.203-218
    • /
    • 2004
  • The purpose of this study was to analyze the comparisons of the kinematical variables when performing Yoko Ukemi(side breakfall) by three Stage in Judo. The subjects were four male judokas who were trainees Y. I. University Squad members and the Yoko Ukemi were filmed by two S-VHS 16mm video cameras(60fields/sec.). The selected times were subject to KWON 3D analysis program and kinematical analysis to compare variables of three Yoko Ukemi. Temporal variables(total time-required : TK, TR by each phase), the body part touched order on the mat and COG variables were computed through video analysis while performing right Yoko Ukemi by three stage. From the data analysis and discussion, the following conclusions were drawn : 1. Temporal variables : total time-required(TR) when performing Yoko Ukemi(side breakfall) by each stage, the first stage(full squat posture: FP : 1.11sec.) showed the shortest time, the next was 3rd(Shizenhontai, straight natural posture: NP : 1.41sec.), and 2nd(Jigohontai, straight defensive posture, DP : 1.42sec.), respectively- 2. TR when performing Yoko Ukemi(side breakfall) by each stage, and phase : the first phase(take of phase, average 0.68sec.) showed the longest time, next was the third phase(ukemi phase, 0.39sec.), and the second phase(air phase, 0.23sec.), respectively. 3. When performing yore Ukemi the body part touched order and TR on the mat : hip(0.94sec.) showed the shortest time, the next was elbow hand(0.97sec.), back(0.98sec.), and shoulder(1.04sec.) order. The hip part touched on the mat the first, but slap the mat in order to alleviate the shock try hand palm and forearm before receiving impact (difference 0.03sec,) 4. Vertical COG variables in each event by each stage : e1(ready position, average 78.33cm) moved the highest, the next was e2(jumping position, 70.14cm), e3(transition position, average 64.00cm), e4(landing position, average 35.99cm), and e5(ukemi position, average 18.32cm) order, gradual decrease respectively. And the difference of COG were showed in initial by each stage, because position fo Yoko Ukemi was difference by each stage in preparation position, but in accordance with executing of Ukemi phase that difference of COG was by decreasing, almost equal displacement in e4(landing) and e5(Ukemi)position finally.

가변 위상변위 스위칭방식을 적용한 연료전지용 변압기 직렬형 DC/DC 컨버터 (Series Connected DC/DC Converter for Fuel Cell System using Variable Phase Shift Switching Method)

  • 박노식;권순재;박성준
    • 전력전자학회논문지
    • /
    • 제13권6호
    • /
    • pp.461-468
    • /
    • 2008
  • 본 논문에서는 연료전지용 전력변환 장치에서 높은 승압비를 구현하기 위하여 절연형 풀브릿지 컨버터의 고주파 변압기 2차측을 직렬로 연결한 새로운 DC/DC 컨버터와 이에 적합한 가변 위상변위 스위칭 방식을 제안하였다. 제안된 컨버터는 기존 방식에 비해 정류부와 필터부의 일원화가 가능한 구조로 출력레벨의 증가를 위해 컨버터의 수를 증가 하더라도, 수동소자의 수를 대폭 줄일 수 있다. 제안된 직렬 방식의 컨버터의 출력전압은 기존의 일정위상변위 스위칭 방식으로는 극성이 반대로 되는 구간이 발생하므로, 제안된 전력변환기에 적합한 간단한 가변 위상 변위 스위칭 방식을 적용함으로써, 출력전압의 감소문제를 해결하였으며, 시뮬레이션과 실험을 통하여 제안된 방식의 타당성을 검증하였다.

6고조파 주입 PWM을 이용한 3상 승압형 컨버터 고조파저감 (Harmonic Reduction in Three-Phase Boost Converter with Sixth Order Harmonic Injected PWM)

  • 이정호;김재문;이정훈;원충연;김영석;최세완
    • 전력전자학회논문지
    • /
    • 제5권2호
    • /
    • pp.176-183
    • /
    • 2000
  • 본 논문에서는 단일 스위치 3상 승압형 컨버터 입력전류의 왜형을 개선하기 위한 6고조파 주입 PWM 방식이 제안디었다. 주기적인 6고조파 전압이 한 스위칭 사이클 내에 컨버터 스위치의 듀비티를 가변하도록 제어회로에 주입되었다. 그 결과 입력 상전류는 입력전압을 따라가고 거의 1에 가까운 역률을 얻었다. 실험결과는 3상 입력 AC 140∼220V, 400V∼6kW 저항부하와 3상 AC 220V, 비선형 부하인 CO2 아크 용접기에 의하여 입증하였다.

  • PDF

고체형 정밀 공진 자이로스코프를 위한 이차 PLL 루프필터 기반 위상제어루프 설계 (Phase Control Loop Design based on Second Order PLL Loop Filter for Solid Type High Q-factor Resonant Gyroscope)

  • 박상준;용기력;이영재;성상경
    • 제어로봇시스템학회논문지
    • /
    • 제18권6호
    • /
    • pp.546-554
    • /
    • 2012
  • This paper suggests a design method of an improved phase control loop for tracking resonant frequency of solid type precision resonant gyroscope. In general, a low cost MEMS gyroscope adapts the automatic gain control loops by taking a velocity feedback configuration. This control technique for controlling the resonance amplitude shows a stable performance. But in terms of resonant frequency tracking, this technique shows an unreliable performance due to phase errors because the AGC method cannot provide an active phase control capability. For the resonance control loop design of a solid type precision resonant gyroscope, this paper presents a phase domain control loop based on linear PLL (Phase Locked Loop). In particular, phase control loop is exploited using a higher order PLL loop filter by extending the first order active PI (Proportion-Integral) filter. For the verification of the proposed loop design, a hemispherical resonant gyroscope is considered. Numerical simulation result demonstrates that the control loop shows a robust performance against initial resonant frequency gap between resonator and voltage control oscillator. Also it is verified that the designed loop achieves a stable oscillation even under the initial frequency gap condition of about 25 Hz, which amounts to about 1% of the natural frequency of a conventional resonant gyroscope.