• Title/Summary/Keyword: the Phase of Order

Search Result 6,140, Processing Time 0.046 seconds

유한요소법을 이용한 축대칭 주조의 응고 및 변형공정 해석

  • 구본영;금영탁
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.337-341
    • /
    • 1997
  • The purpare of this research is to develope a FEM program for analyzing solidification processes of axisymmetic casting, considering phase changes and the contact between the metal and mold. Temperture recovery method is employed for considering the phase changes releasing the latent heat. A gap element is employed for modeling the interface between the model and metal in finding deformed shapes. In order to verify the developed program, an axisymmetric aluminum casting processes is simulated. Temperature distribution, phase front position, and shrinkaga and porosity creation are compared with measurement, FIDAP results, and ANSYS results, and good agreements are examined.

Limitations of the Linear Solvation Energy Relationships in Reversed Phase Liquid Chromatography

  • Cheong, Won-Jo;Choi, Jang-Duck
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.10
    • /
    • pp.868-873
    • /
    • 1994
  • We have re-examined the linear solvation energy relationships in reversed phase liquid chromatography by considering various solutes including quite a number of compounds of strong hydrogen bond capability. We observed that solutes of strong hydrogen bond ability should be excluded in order to obtain resonable correlations between In k' and solute polarity parameters and that inclusion of one or two such solutes causes severe distortions of correlation results. This anomaly may be due to existence of residual silanol groups in the stationary phase, that is, their specific interactions with solutes.

Harmonic Reduction in Three-Phase Boost Converter with Six Harmonic Injected PWM (6고조파 주입 PWM을 이용한 3상 승압형 컨버터 고조파저감)

  • 이정훈;김재문;안정준;이정호;원충연;정동효
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.327-332
    • /
    • 1999
  • In this paper, six harmonic injection PWM method for reducing total harmonic distortion in single switch three phase discontinuous conduction mode boost converter is presented. In the proposed method, periodic six harmonic voltage is injected in the control circuit to vary the duty ratio of the converter switch within a line cycle so that the fifth order harmonic of the input current is reduced. Experimental results are verified by converter operating at 400V/6kW with three phase 140V~220V input.

  • PDF

A control method and test results of utility interactive photovoltaic power generation systems (계통연계 태양광발전시스템의 제어기법 및 연계운전특성)

  • 안교상;임희천;황인호;주형준
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.549-553
    • /
    • 1999
  • This paper describes a design method of grid-connected photovoltaic power generation systems with three phase inverter. A 3-phase 50kW photovoltaic power generation system including a DC/AC inverter is designed and made in order to investigate the system performance for grid connection. Also the control scheme of a three phase current-controlled PWM inverter is presented by using d-q transformation. The experimental waveforms show that the proposed system has stable behavior with an unit power factor in utility-interactive operation.

  • PDF

Nuclear Magnetic Resonance of a Layered Organic-Inorganic Hybrid System (C8H17NH3)2SnCl6

  • Lee, Kyu Won;Lee, Cheol Eui
    • Journal of Magnetics
    • /
    • v.9 no.1
    • /
    • pp.1-4
    • /
    • 2004
  • Three successive phase transitions in bis-n-octhylammonium hexachlorostannate, $(n-C_8H_{17}NH_3)_2SnCl_6$, were studied by means of the ^1H nuclear magnetic resonance linewidth and spin-lattice relaxation measurements. Unlike the compounds with longer hydrocarbon chains, the order-disorder and conformational nature were found to coexist in the phase transitions.

A study on the Dual Digital Phase Locked Loop (Dual-Digital Phase-Locked Loop에 관한 연구)

  • 김수일;이상범;성상기;김중태;최승철
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1987.04a
    • /
    • pp.230-233
    • /
    • 1987
  • A Dual Disital Phase Locked Loop is analyzeddesigned and tested. Two specific confisurations are considered generations second and thisrd order DPLL’s and it is found using a computer simulation and verified therretically . As a result of computer simulation the characteristcof designed I-Dullis better than the at of P-DPLL or C-Dull

  • PDF

Greenhouse Gas Management Policy during Construction Execution Phase -Focused on Green Building Rating Systems and Japanese Case- (건축물 시공단계에서의 온실가스 배출 관리 방안 -국내외 친환경 인증제도와 일본 현장의 대응 방안을 중심으로-)

  • Song, Sang Hoon
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.139-150
    • /
    • 2010
  • Until now, the eco-friendly construction (green construction) has been focused on reducing environmental impacts in use(operation and maintenance) phase. Considering the environmental influence along the life cycle of construction project, the impact in execution phase is rather lower than that in use phase. However, that impact is thought to be greatly decreased by well-organized activities. Based on its urgency and requirement for timely action, this study aimed to discuss the greenhouse gas (GHG) reduction plan in execution phase from a broad perspective. To achieve this purpose, the green building rating systems in domestic and foreign countries have been reviewed, and the practice in Japan was investigated. In order to improve current on-site greenhouse gas management, the integration among construction phases, participants, and environmental factors, and institutional supports are required as well as the contractor's efforts.

A Control Algorithm of Single Phase Active Power Filter based on Rotating Reference Frame (회전좌표계를 이용한 단상능동전력필터의 제어이론)

  • Kim, Jin-Sun;Kim, Young-Seok;Shin, Jae-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1480-1482
    • /
    • 2005
  • The major causes of power quality deterioration are harmonic current through semiconductor switching device, due to use of nonlinear loads such as diodes rectifier or thyristor rectifiers. In response to this concerns, this paper presents a new control method of single-phase active power filter(APF) for the compensation of harmonic current components in nonlinear loads. In order to make the complex calculation to be possible, the single-phase system that has two phases was made by constructing a imaginary second-phase giving time delay to load currents. In the conventional method, a imaginary-phase lagged to the load current T/4(here T is the fundamental cycle) was made. But in this proposed method, the new signal, which has the delayed phase through the filter, using the phase-delay property of low-pass filter, was used as the second phase. As this control method is applied to the system of single phase, an instantaneous calculation was done rather by using the rotating reference frames that synchronizes with source-frequency than by applying instantaneous reactive power theory that uses the conventional fixed reference frames.

  • PDF

An Experimental Study on the Latent Heat Storage Using Phase Change Material Within Cylindrical Can (원통형 용기에서의 잠열 축열에 관한 실험적 연구)

  • Go, Deuk-Yong;Choe, Heon-O;Kim, Hyo-Bong
    • 한국기계연구소 소보
    • /
    • s.19
    • /
    • pp.23-30
    • /
    • 1989
  • Heat transfer phenomena of solidification process of the phase change material within cylindrical can is studied experimentally. N-Eicosane paraffin wax is used for phase change material and its melting temperature is 309.8 K. In order to achieve higher heat transfer rate of latent heat storage apparatus, fins in made of copper are used in the cylindrical can. If there are fins in cylindrical can, we can know that the inward latent heat energy in paraffin can be effectively transfered to cooling water than if finless.

  • PDF

MPS eutectic reaction model development for severe accident phenomenon simulation

  • Zhu, Yingzi;Xiong, Jinbiao;Yang, Yanhua
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.833-841
    • /
    • 2021
  • During the postulated severe accident of nuclear reactor, eutectic reaction leads to low-temperature melting of fuel cladding and early failure of core structure. In order to model eutectic melting with the moving particle semi-implicit (MPS) method, the eutectic reaction model is developed to simulate the eutectic reaction phenomenon. The coupling of mass diffusion and phase diagram is applied to calculate the eutectic reaction with the uniform temperature. A heat transfer formula is proposed based on the phase diagram to handle the heat release or absorption during the process of eutectic reaction, and it can combine with mass diffusion and phase diagram to describe the eutectic reaction with temperature variation. The heat transfer formula is verified by the one-dimensional melting simulations and the predicted interface position agrees well with the theoretical solution. In order to verify the eutectic reaction models, the eutectic reaction of uranium and iron in two semi-infinite domains is simulated, and the profile of solid thickness decrease over time follows the parabolic law. The modified MPS method is applied to calculate Transient Reactor Test Facility (TREAT) experiment, the penetration rate in the simulations are agreeable with the experiment results. In addition, a hypothetical case based on the TREAT experiment is also conducted to validate the eutectic reaction with temperature variation, the results present continuity with the simulations of TREAT experiment. Thus the improved method is proved to be capable of simulating the eutectic reaction in the severe accident.