• Title/Summary/Keyword: the AIR model

Search Result 5,901, Processing Time 0.047 seconds

Changes in Physical Characteristics of Chinese Cabbage during Salting and Blanching (염절임 및 Blanching시 배추의 물리적 특성의 변화)

  • Kim, Ju-Bong;Yoo, Myung-Sik;Cho, Hyung-Yong;Choi, Dong-Won;Pyun, Yu-Ryang
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.445-450
    • /
    • 1990
  • Changes in weight, volume and density of petiole tissue of Chinese cabbage during salting and blanching were investigated. Rapid changes in mass and volume occurred within 4 hours during salting in 5% salt solution and the changes were nearly completed after 8h. After salting, the reduction of mass and volume ranged between $22{\sim}27%\;and\;22{\sim}35%$, respectively. Average density of the sample was found to be 0.88g/ml, and increased to 1.020g/ml after salting. Air content of the sample ranged from 0.093 to 0.120ml/ml cabbage, and about 70% of the initial content was expelled from the tissue by salting. The changes of physical properties of the cabbage during steam blanching were similar to those during salting, but their relative values were smaller. A linearization model for physical changes during salting and blanching was proposed.

  • PDF

Numerical analysis of solar heat gain on slim-type double-skin window systems - Heat transfer phenomena with opening of windows and vent slot in summer condition - (전산유체 해석을 통한 슬림형 이중외피 창호의 태양열 취득량 분석 - 높은 태양고도 및 하절기 냉방조건에서의 자연환기구 적용 및 창문 조절 방식별 비교 -)

  • Park, Ji-Ho;Oh, Eun-Joo;Cho, Dong-Woo;Cho, Kyung-Joo;Yu, Jung-Yeon
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.69-75
    • /
    • 2017
  • Purpose: Heat transfer analysis of recently developed 'slim type double-skin system window' were presented. This window system is designed for curtain wall type façade that main energy loss factor of recent elegant buildings. And the double skin system is the dual window system integrated with inner shading component, enclosed gap space made by two windows when both windows were closed and shading component effectively reflect and terminate solar radiation from outdoor. Usually double-skin system requires much more space than normal window systems but this development has limited by 270mm, facilitated for curtain wall façade buildings. In this study, we estimated thermophysical phenomena of our double-skin curtain wall system window with solar load conditions at the summer season. Method: A fully 3-Dimentional analysis adopted for flow and convective and radiative heat transfer. The commercial CFD package were used to model the surface to surface radiation for opaque solid region of windows' frame, transparent glass, fluid region at inside of double-skin and indoor/outdoor environments. Result: Steep angle of solar incident occur at solar summer conditions. And this steep solar ray cause direct heat absorption from outside of frame surface rather than transmitted through the glass. Moreover, reflection effect of shading unit inside at the double-skin window system was nearly disappeared because of solar incident angle. With this circumstances, double-skin window system effectively cuts the heat transfer from outdoor to indoor due to separation of air space between outdoor and indoor with inner space of double-skin window system.

Effect of Modified Atmosphere Packaging Gas Composition on Quality Preservation of Korean Rockfish Fillets (조피볼락 필렛의 변형기체포장에서 품질보존에 미치는 기체조성의 영향)

  • Eo Jin Park;Su Chan Kim;Duck Soon An
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.3
    • /
    • pp.145-151
    • /
    • 2023
  • In order to extend shelf life for rockfish fillets by modified atmosphere packaging (MAP), different package atmospheres were compared in the product quality preservation. Firstly, CO2 solubility was measured at 0, 5, 10, and 15℃ to be incorporated into the mathematical model to predict the volume and CO2 concentration of the package at expected storage temperature. The CO2 solubility given in Henry's constant decreased with temperature to be fitted with a linear equation. Then air packaging as control and four MAP conditions of 100 g fillets were prepared and stored for duration of 5 days at 10℃ to compare them in the quality preservation effect. Four MAP conditions employed were CO2(60):O2(30):N2(10), CO2(60):O2(0):N2(40), CO2(30):O2(30):N2(40) andCO2(30):O2(0):N2(70). MAP conditions with high CO2 concentration inhibited total aerobic bacteria, and the conditions containing O2 led to low TVB-N. MAP of CO2(60):O2(30):N2(10) was found to be the best condition for rockfish fillet preservation considering total aerobic bacteria growth and nitrogenous volatiles production.

A Comparison of Symbol Error Performance for SC-FDE and OFDM Transmission Systems in Modeled Underwater Acoustic Communication Channel (모델링된 수중음향 채널환경에서 SC-FDE와 OFDM 전송방식의 심볼오율 비교)

  • Hwang, Ho-Seon;Park, Gyu-Tae;Joo, Jae-Hoon;Shin, Kee-Cheol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.139-146
    • /
    • 2018
  • Underwater acoustic communication can be applied to various area such as scientific, commercial and military survey using Autonomous Underwater Vehicles and Unmanned Underwater Vehicles. Underwater communication is studying very actively by advanced country like United States. But differ from wireless communication in the air, underwater acoustic communication has some difficult problems, ISI(Inter Symbol Interference) due to multipath and limit of transmission bandwidth due to slow propagation of sound wave. In this paper, SC-FDE and OFDM transmission system for the cancellation of ISI in conjunction with underwater acoustic channel modeling are applied to the underwater simulation of communication. The performance of these methods in the simulation guide to possibility of adopting in underwater acoustic communication algorithm. For this purpose, we compare SER performance of SC-FDE with that of OFDM for modelled underwater channel. Underwater channel is generated by Bellhop model. Simulation results show above 5dB SNR gain at 10-3 SER. And it demonstrate SC-FDE is efficient method for underwater acoustic communication.

A COMPARISON OF FLUORESCENCE EFFECT OF VARIOUS LIGHT SOURCES IN EARLY ENAMEL CARIES (초기 우식 병소에서 광원에 따른 형광효과 비교)

  • Jeon, Jeong-Hoon;Lee, Nan-Young;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.611-619
    • /
    • 2005
  • The aim of this study was to apply the quantitative light-induced fluorescence(QLF) and use of fluorescein-enhanced QLF method for quantitative assessment of early enamel demineralization in vitro, comparing effectiveness of light sources : argon laser, halogen lamp, light emitting diode (LED) and plasma arc lamp. Sixty extracted teeth were used, prepared by gentle pumicing and coating in an acid-resistant nail-varnish, except for an exposure to a demineralizing solution. Teeth were removed at regular intervals (24, 48 and 72hrs), air-dried and QLF image were taken. Mineral loss, as measured by difference of optical density, was recorded. For dyeenhanced QLF a 0.075% sodium fluorescein dye was applied after QLF examination and mineral loss was recorded. The following result were obtained : 1. Comparing with mean difference of optical density, plasma arc lamp was higher than other light sources in all group (p<0.05). 2. Comparing each group with mean difference of optical density, there was significant different using plasma are lamp and halogen lamp. 3. For use of dye-enhanced QLF, comparing with mean difference of optical density, plasma arc lamp were higher than other light sources in all group(p<0.05). 4. With this model dye-enhanced QLF compared with QLF in optical density, dye-enhanced QLF was higher than QLF in optical density. From the results presented in this paper, it was concluded that plasma light source was more effective compared with other light source for the detection and the quantification of early enamel caries.

  • PDF

Effect of Partially Oxidized Ti Powder on Electrical Properties and Microstructures of $BaTiO_3$-based Ceramics ($BaTiO_3$계 세라믹스의 전기적 성질과 미세조직에 미치는 부분산화 Ti 분말 첨가의 영향)

  • Kim, Jun-Gyu;Jo, Won-Seung;Park, Gyeong-Sun
    • Korean Journal of Materials Research
    • /
    • v.10 no.10
    • /
    • pp.671-676
    • /
    • 2000
  • $BaTiO_3$-based ceramics with partially oxidized Ti powders were prepared by sintering at $1350^{\circ}C$ for 1 h in v vacuum, and then heated in air. In this study, the effect of partially oxidized Ti powders on electrical properties and microstructures of $BaTiO_3$-based ceramics was investigated. It was found out that the semiconductive $BaTiO_3$-based ceramics beζame to show excellent PTCR (more than $10^5$) characteristic by adding 5~7 vol% of partially oxidized Ti powder. Also, it was found out that the sintered compact had extremely porous and fine-grained microstructure. The relative density and grain size of sintered compact with 5 vol% of partially oxidized Ti powders were 54% and $1.3\;{\mu\textrm{m}}$, respectively. The mechanism for the development of PTCR characteristic in $BaTiO_3$-based ceramics with partially oxidized Ti powders due to the adsorption of oxygen at grain boundaries, and could be explained, based on Heywang model.

  • PDF

Rheological Properties of Cement Paste Mixed with Aqueously Dispersed Single-Walled Carbon Nanotubes (Single-Walled 탄소나노튜브 수용액 혼입 시멘트 페이스트의 유변학적 특성)

  • Kim, Ji-Hyun;Chung, Chul-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.2
    • /
    • pp.113-121
    • /
    • 2019
  • Single walled carbon nanotube (SWCNT) has been used as a material for reinforcing various advanced materials because it has superior mechanical properties. However, pure SWCNT that does not have any functional group has a hydrophobic character, and exists as bundles due to the strong Van der Waals attraction between each SWCNT. Due to these reasons, it is very difficult to disperse SWCNTs in the water. In this work, in order to use SWCNT for production of cementitious composites, SWCNT was first dispersed in water to make an aqueous solution. Sodium deoxycholate (DOC) and Sodium dodecyl sulfate (SDS) were chosen as surfactants, and the dosage of DOC and SDS were 2wt% and 1wt%, respectively. Sonication and ultracentrifugation were applied to separate each SWCNT and impurities. Using such processed SWCNT solutions, cement paste was prepared and its shear stress vs. strain rate relationship was studied. The yield stress and plastic viscosity of cement paste were obtained using Bingham model. According to the results in this work, cement pastes made with DOC and SDS showed similar rheological behavior to that of air entrained cement paste. While cement paste made with DOC 2 wt.% SWCNT solution showed similar rheological behavior to that of plain cement paste, cement paste made with SDS 1 wt.% SWCNT solution showed different rheological behavior showing much less yield stress than plain cement paste.

Prevalence and environmental risk factors for respiratory symptoms among elementary school children in a city (도시지역 초등학교 저학년 학생들의 호흡기계 증상 유병률에 영향을 주는 환경위험요인)

  • Park, Hye-Sook;Lee, Bo-Eun;Ha, Eun-Hee;Kim, Nam-Hee;Hong, Yun-Chul;Lee, Youn-Kyung;Cho, Yong-Sung
    • Journal of the Korean Society of School Health
    • /
    • v.16 no.2
    • /
    • pp.1-11
    • /
    • 2003
  • PURPOSE: The aim of our study was to assess the prevalence of respiratory symptoms and to determine their environmental risk factors in school children living in a city where traffic is particularly heavy. METHODS: From November 12th to November 19th, 2002, we sent questionnaires to parents for children's health and environmental factors, and ninety eight percent (516) of parents responded. RESULTS: The lifetime prevalence of chronic respiratory illness was 12.2% and 13.2% for wheeze, and 6.6% for physician diagnosed asthma. Using multiple logistic regression model, we found that family history of asthma(OR=3.47, 95% CI 1.36-8.78), atopy dermatitis(OR=5.48, 95% CI 2.37-12.66), and pets at home(OR=3.22, 95% CI 1.26-8.23) were associated with chronic respiratory illness in last 12 months. We also found that family history of asthma(OR=3.28, 95% CI 1.16-9.31), atopy dermatitis(OR=2.89, 95% CI 1.11-7.54), and short distance between the house and road(OR=2.85, 95% CI 1.03-7.87) were associated with asthma in last 12 months. CONCLUSIONS: Elementary school children in a city had a relatively high prevalence of chronic respiratory illness and symptoms. In addition to genetic factors, pets at home and outdoor air pollution are associated with respiratory illness and Symptoms in school children.

DEVELOPMENT OF CCD IMAGING SYSTEM USING THERMOELECTRIC COOLING METHOD (열전 냉각방식을 이용한 극미광 영상장비 개발)

  • Park, Young-Sik;Lee, Chung-Woo;Jin, Ho;Han, Won-Yong;Nam, Uk-Won;Lee, Yong-Sam
    • Journal of Astronomy and Space Sciences
    • /
    • v.17 no.1
    • /
    • pp.53-66
    • /
    • 2000
  • We developed low light CCD imaging system using thermoelectric cooling method collaboration with a company to design a commercial model. It consists of Kodak KAF-0401E(768$\times$512 pixels) CCD chip, thermoelectric module manufactured by Thermotek. This TEC system can reach an operative temperature of $-25^{\circ}C$. We employed an Uniblitz VS25s shutter and it has capability a minimum exposure time 80ms. The system components are an interface card using a Korea Astronomy Observatory (hereafter KAO) ISA bus controller, image acquisition with AD9816 chip, that is 12bit video processor. The performance test with this imaging system showed good operation within the initial specification of our design. It shows a dark current less than 0.4e-/pixel/sec at a temperature of $-10^{\circ}C$, a linearity 99.9$\pm$0.1%, gain 4.24e-/adu, and system noise is 25.3e-(rms). For low temperature CCD operation, we designed a TEC, which uses a one-stage peltier module and forced air heat exchanger. This TEC imaging system enables accurate photometry($\pm$0.01mag) even though the CCD is not at 'conventional' cryogenic temperatures(140k). The system can be a useful instrument for any other imaging applications. Finally, with this system, we obtained several images of astronomical objects for system performance tests.

  • PDF

Measurement of Dust Concentration in a Mechanically Ventilated Broiler House and Analysis of Dust Generation from Ground Beds (강제환기식 계사의 공기 중 분진 농도 측정 및 바닥재로부터의 분진 발생량 분석)

  • Kwon, Kyeong Seok;Jo, Ye Seul;Lee, In Bok;Ha, Tae Hwan;Hong, Se Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.6
    • /
    • pp.31-43
    • /
    • 2014
  • Confined and mechanically ventilated broiler house has been recently come into wide use to increase productivity and control rearing conditions. However, high dust concentration inside facility can threaten respiratory welfare of farmers and broilers. In Korea, there is no regulation in terms of air quality control inside agricultural facilities and sufficient data is not available. To cope with these, periodic monitoring of inhalable and respirable dust concentration were conducted according to season, broiler's activity and specific events such as shipment work for broilers in mechanically ventilated broiler house. Chamber experiment was also designed to analyze mechanism of dust generation from ground beds according to water contents and surrounding wind environment. Results showed that significant increase of inhalable (p=0.002) and respirable (p=0.03) dust were observed when activity of broilers was high according to entrance of the workers. Even shipment work for matured broilers, high level of dust were observed; inhalable dust was exceeded the threshold limit over maximum 303 % and respirable dust was over maximum 1,550 %, implying that acute respiratory symptoms could be manifested for the workers. From the chamber experiment, critical water contents for interrupting of dust generation were measured; about 45 % for inhalable dust and about 50 % for respirable dust. These results can be a trigger for designing plan of dust control however it still needs consideration of various environmental conditions, hygiene problems, etc.