• Title/Summary/Keyword: the AIR model

Search Result 5,901, Processing Time 0.035 seconds

A Mathematical Model for Color Changes in Red Pepper during Far Infrared Drying

  • Ning, XiaoFeng;Han, ChungSu;Li, He
    • Journal of Biosystems Engineering
    • /
    • v.37 no.5
    • /
    • pp.327-334
    • /
    • 2012
  • Purpose: The color changes in red pepper during far infrared drying were studied in order to establish a color change model. Methods: The far infrared drying experiments of red pepper were conducted at two temperature levels of 60, $70^{\circ}C$ and two air velocity levels of 0.6 and 0.8 m/s. The results were compared with the hot-air drying method. The surface color changes parameters of red pepper were measured qualitatively based on L (lightness), a (redness), b (yellowness) and total color changes (${\Delta}E$). The goodness of fit of model was estimated using the coefficient of determination ($R^2$), the root mean square error (RMSE), the mean relative percent error (P) and the reduced chi-square (${\chi}^2$). Results: The results show that an increase in drying temperature and air velocity resulted in a decrease in drying time, the values of L (lightness) and a (redness) decreased with drying time during far infrared drying. The developed model showed higher $R^2$ values and lower RMSE, P and ${\chi}^2$ values. Conclusions: The model in this study could be beneficial to describe the color changes of red pepper by far infrared drying.

Modeling and Evaluation on the Dispersion of Air Pollutants in the Large Scale Thermal Power Plant (대단위발전소의 대기오염물질 확산에 관한 모델링 및 평가에 관한 연구)

  • Chun, Sang-Ki;Lee, Sung-Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.6 no.2
    • /
    • pp.81-92
    • /
    • 1997
  • This paper presents the results from the comparison analysis and evaluation between the air pollutant dispersion modeling results and the observation data in the area within a 10 km radius from the Boryong thermal power plants. The observation data used in this study were the air pollutant concentrations which had been continuously measured from 8 locations around the Boryong power plants by TMS(tele-monitoring system) for 3 months from September to November, 1996. The short-term and long-term predictions were carried out using ISC3 model and LPDM(Lagrangian Panicle Dispersion Model). The results of ISC3 modeling in a short-term showed highly as 0.7 in a correlation coefficient, but in a long-term showed just 0.54. On the other hand, LPDM showed 0.78 in a correlation coefficient for a long-term, but in a short-term showed highly value than the observation concentrations.

  • PDF

How about the IAQ in Subway Environment and Its Management?

  • Song, Ji-Han;Lee, Hee-Kwan;Kim, Shin-Do;Kim, Dong-Sool
    • Asian Journal of Atmospheric Environment
    • /
    • v.2 no.1
    • /
    • pp.60-67
    • /
    • 2008
  • The spatial limitations of urban environments in general lead to invention and design of a wide range of underground transportation systems such as subways, underground roads and paths, etc. Among them, the application of subway systems in metropolitan cities is most commonly observed to ease those confronted difficulties on this purpose. It in turn leaves passengers and workers to be exposed to indoor air potentially polluted by various sources existing in this underground environment. Specifically when considering the IAQ in a subway station, there exist many IAQ-related parameters to be counted either as individual or as integrated exposures. In this study, a model system has been developed to manage the general IAQ in a subway station. Field survey and $CO_2$ measurements were initially conducted to analyze and understand the relationship between the indoor and outdoor air quality while considering the internal pollution sources such as passengers, subway trains, etc. The measurement data were then employed for the model development with other static information. For the model development, the algorithm of simple continuity was built and applied to model the subway IAQ concerned. In this paper, the recent updated draft version of model developed will be reported and demonstrated.

A Study on Thermal Environment Analysis of a Greenhouse (시설원예용 난방온실의 온열환경 분석에 관한 연구)

  • Song, Lei;Park, Youn Cheol
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.3
    • /
    • pp.15-20
    • /
    • 2018
  • To study the effects of solar energy in a greenhouse, outdoor air temperature and wind speed on inside air temperature, a simulation model for forecasting the greenhouse air temperature was conducted on the basis of the energy and mass balance theory. Application of solar energy to the greenhouse is major area in the renewable energy research and development in order to save energy. Recently, considering the safety and efficiency of the heating of greenhouse, clean energy such as geothermal and solar energy has received much attention. The analysed greenhouse has $50m^2$ of ground area which located in jocheon-ri of Jeju Province. Experiments were carried out to collect data to validate the model. The results showed that the simulated air temperature inside a plastic greenhouse agreed well with the measured data.

An Analysis on the Electricity Demand for Air Conditioning with Non-Linear Models (비선형모형을 이용한 냉방전력 수요행태 분석)

  • Kim, Jongseon
    • Environmental and Resource Economics Review
    • /
    • v.16 no.4
    • /
    • pp.901-922
    • /
    • 2007
  • To see how the electricity demand for air-conditioning responds to weather condition and what kind of weather condition works better in forecasting maximum daily electricity demand, four different regression models, which are linear, exponential, power and S-curve, are adopted. The regression outcome turns out that the electricity demand for air-conditioning is inclined to rely on the exponential model. Another major discovery of this study is that the electricity demand for air-conditioning responds more sensitively to the weather condition year after year along with the higher non-air-conditioning electricity demand. In addition, it has also been found that the discomfort index explains the electricity demand for air-conditioning better than the highest temperature.

  • PDF

Estimation of Air Concentrations of PCBs using Passive Air Samplers (PAS) and a Gas/particle Partition Model (Passive Air Sampler (PAS)와 기체/입자 분배모델을 이용한 대기 중 PCB 농도 산정)

  • Baek, Song-Yee;Choi, Sung-Deuk;Chang, Yoon-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.6
    • /
    • pp.734-743
    • /
    • 2007
  • Polyurethane foam-disk passive air samplers (PAS) were deployed in a southern area of Korea for three months. The target compounds were 12 coplanar polychlorinated biphenyls (PCBs). The congener profiles measured in this study were the same as those in ambient air and emission gas from the incinerator. A gradient of the total PCBs in different regions (industrial>residential>rural) was observed, suggesting the industrial complex may be an important source of coplanar PCBs. In general, only gas-phase compounds are mainly sequestrated by PAS. In order to estimate the concentration of particle-phase PCBs, a gas/particle partition model was used. A combined result (gas+particle-phase PCBs) was compared with previous results, indicating that the level of coplanar PCBs in our study area is comparable to those in other urban sites in the world. The validation of this method for estimating the total concentration is required through additional backup studies.

An Evaluation Study on Combustion and Thermal Flow Characteristics of G+R Type Incinerator (G+R 타입 소각연소로의 연소 및 열유동 특성평가 연구)

  • Shin, Dong-Hoon;Shin, Dong-Hoon;Baek, Ik-Hyun;Jung, Sang-Soon
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.111-117
    • /
    • 2003
  • The present study discusses about the combustion and thermal flow characteristics of a G+R type incinerator, which is under construction for MAPO Incineration system, to evaluate the effects of various operating and design parameters. A bed combustion model is developed to simulate the waste bed combustion on the stoker. The effects of waste composition and primary air distribution are estimated. The results of the waste bed combustion model is applied to CFD(computational fluid dynamics) simulation, which simulates the detail of the thermal flow in the combustion chamber. The effects of bypass damper opening ratio, primary air distribution, and secondary air jet configuration are discussed.

  • PDF

A Variational Framework for Single Image Dehazing Based on Restoration

  • Nan, Dong;Bi, Du-Yan;He, Lin-Yuan;Ma, Shi-Ping;Fan, Zun-Lin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.3
    • /
    • pp.1182-1194
    • /
    • 2016
  • The single image dehazing algorithm in existence can satisfy the demand only for improving either the effectiveness or efficiency. In order to solve the problem, a novel variational framework for single image dehazing based on restoration is proposed. Firstly, the initial atmospheric scattering model is transformed to meet the kimmel's Retinex variational model. Then, the green light component of image is considered as an input of the variational framework, which is generated by the sensitivity of green wavelength. Finally, the atmospheric transmission map is achieved by multi-resolution pyramid reduction to improve the visual effect of the results. Experimental results demonstrate that the proposed method can remove haze effectively with less memory consumption.

Effects of Earth-Tube Characteristics on the Soil-Air Heat Exchanger Performances (지중매설관의 특성이 토양 - 공기 열교환기 성능에 미치는 영향)

  • 김영복
    • Journal of Biosystems Engineering
    • /
    • v.22 no.4
    • /
    • pp.459-468
    • /
    • 1997
  • To optimize the design and operation of a soil- air heat exchanger system, the effects of variables characterizing system design and operation on the performance of the system were analyzed by a theoretical model which included the three-dimensional transient heat conduction equation. The solution of the theoretical model was acquired by a computer program that uses Finite Difference Methods and Gauss-Seidel iteration computation, in which the time discretization scheme was an implicit difference appoximation. The computer program was validated first by comparison of the results for different grid sizes. Air outlet temperature, energy gain, and heat exchange efficiency of the system were analyzed based upon the tube diameter, tube length, tube thickness, and tube thermal diffusivity.

  • PDF

Cavitation Characteristics of a Pump-turbine Model by CFD Analysis

  • Singh, Patrick Mark;Chen, Chengcheng;Chen, Zhenmu;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.4
    • /
    • pp.49-55
    • /
    • 2015
  • The pumped storage plant operates with quick change of the discharge as well as quick changes between pump mode and turbine mode. This study focuses on the cavitation analysis of a pump-turbine model because in turbo-machinery, cavitation can reduce the performance and shorten service life. The pump-turbine model system consists of 7 blades, 20 stay vanes (including tongue) and 20 guide vanes. This study adopts the Rayleigh-Plesset model as a cavitation model, which illustrates cavitation by using the air volume fraction method. The pump mode and turbine mode at the operating condition of partial loading, normal and excessive loading are analyzed to investigate the cavitation performance of the pump-turbine. It was observed that this pump-turbine design showed very good cavitation characteristics with no cavitation bubbles in all operating conditions. Overall value of air volume fraction of both mode at different operating condition are lower than 1, which confirms low possibility of cavitation occurrence at current situation.