Abstract

The spatial limitations of urban environments in general lead to invention and design of a wide range of underground transportation systems such as subways, underground roads and paths, etc. Among them, the application of subway systems in metropolitan cities is most commonly observed to ease those confronted difficulties on this purpose. It in turn leaves passengers and workers to be exposed to indoor air potentially polluted by various sources existing in this underground environment. Specifically when considering the IAQ in a subway station, there exist many IAQ-related parameters to be counted either as individual or as integrated exposures. In this study, a model system has been developed to manage the general IAQ in a subway station. Field survey and $CO_2$ measurements were initially conducted to analyze and understand the relationship between the indoor and outdoor air quality while considering the internal pollution sources such as passengers, subway trains, etc. The measurement data were then employed for the model development with other static information. For the model development, the algorithm of simple continuity was built and applied to model the subway IAQ concerned. In this paper, the recent updated draft version of model developed will be reported and demonstrated.

Keywords

Cited by

  1. A computational analysis of the airflow in a twin-track subway tunnel with a sliding-curtain to improve ventilation performance vol.27, pp.8, 2013, https://doi.org/10.1007/s12206-013-0620-y
  2. Numerical optimization study to install air curtain in a subway tunnel by using design of experiment vol.28, pp.1, 2014, https://doi.org/10.1007/s12206-013-0947-4
  3. Installation of platform screen doors and their impact on indoor air quality: Seoul subway trains vol.64, pp.9, 2014, https://doi.org/10.1080/10962247.2014.923350
  4. Effect of platform screen doors on the indoor air environment of an underground subway station vol.24, pp.5, 2015, https://doi.org/10.1177/1420326X14528731
  5. Effect of guide vanes on recovering uniform flow in a ventilation duct in an existing twin-track subway tunnel vol.29, pp.1, 2015, https://doi.org/10.1007/s12206-014-1231-y
  6. Chemical Properties and Source Profiles of Particulate Matter Collected on an Underground Subway Platform vol.9, pp.2, 2015, https://doi.org/10.5572/ajae.2015.9.2.165
  7. concentrations and their human health impacts in the metro subway system of Suzhou, China vol.19, pp.5, 2017, https://doi.org/10.1039/C6EM00655H
  8. A Computational Analysis of Flow Field in Twin-Track Subway Tunnel to Improve Air Quality vol.319, pp.1662-7482, 2013, https://doi.org/10.4028/www.scientific.net/AMM.319.599
  9. Box Model Approach for Indoor Air Quality (IAQ) Management in a Subway Station Environment vol.8, pp.4, 2008, https://doi.org/10.5572/ajae.2014.8.4.184
  10. Environmental and Health Effects of Ventilation in Subway Stations: A Literature Review vol.17, pp.3, 2008, https://doi.org/10.3390/ijerph17031084