• Title/Summary/Keyword: test standard

Search Result 8,527, Processing Time 0.042 seconds

Loss of a Main Feedwater Pump Test at 100% Power Simulation using Korean Standard Nuclear Plant Analyzer (KSNPA)

  • Jeong, Won-Sang;Kim, Shin-Whan;Sung, Kang-Sik;Seo, Jong-Tae;Lee, Sang-Keun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.296-302
    • /
    • 1996
  • The Loss of a Main Feedwater Pump test at 100% Power for YGN 4 was simulated in order to verify and validate the KSNPA. The comparison of the test data with the KSNPA prediction results showed reasonable agreement in the trends of the major plant parameters. All plant control systems including NSSS and T/G control systems are properly actuated and stabilized the plant conditions to a new steady state conditions in the KSNPA. From the comparison results, the KSNPA showed its capability to simulate the LOMFP event for the Korean Standard Nuclear Power Plant.

  • PDF

Studies on the evaluation of efficacy of functional cosmetics (I) -Studies on the in vitro SPF test method of sunscreen products

  • Son, Kyung-Hun;Kim, Young-Ok;Lee, Jeong-Pyo;Yang, Seong-Jun;Paek, Ock-Jin;Kim, Won-Hee;Kim, Chong-Kap;Heo, Moon-Young;Choi, Sang-Sook
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.404.2-404.2
    • /
    • 2002
  • The present study was undertaken to develop the in vitro sun protection factor(SPF) test method having good correlation with in vivo method using human. 8% homomentyl salicylate. P3 reference standard and commercially available sunscreen products were measured by the in vitro method using SPF 290S analyzer. and the SPFs were compared with the SPFs measured by in vivo test method. In vitro SPFs of 8% HMS and P3 reference standard were 4.59$\pm$0.12 and 14.94$\pm$0.83. (omitted)

  • PDF

Studies on the Standard Protocols of Bioequivalence Test

  • Yoon, Kyung-Eun;Chung, Soo-Youn;Park, Ki-Sook;Choi, Hong-Suk;Baek, Min-Sun;Jung, Sung-Hee;Choi, Sun-Ok
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.315.1-315.1
    • /
    • 2003
  • After beginning the new medical system separating the prescription from the drug dispensary, the demand of bioequivalence test significantly increases to show the equivalence between the test and reference drugs as a result of amendment of the pharmaceutical affairs law which allows a generic substitution. Accordingly the standard protocols provided by the government are required for reducing the period andthe cost to perform the bioequivalence study. (omitted)

  • PDF

A Study on On-site Discharge Testing for Carbon Dioxide Fire Extinguishing Systems (이산화탄소 소화설비 현장 방출시험 방법론에 관한 고찰)

  • Park, Jun-Hyun;Kang, Tae-Seok;Kim, Jae-Hwan;Kim, Wee-Kyong
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.26-32
    • /
    • 2015
  • Carbon dioxide principally extinguishes fires by smothering, but an acceptable amount of extinguishing agent is needed. To assure the performance of carbon dioxide systems in Korea, computer programs certified by NEMA are being applied in system design. But the design errors can occur because the geometry of a model test facility is not the same as that of the actual fire area. Since the discharge rate tends to vary considerably with the flow pattern in a pipe, an on-site discharge test is necessary to ensure the performance of the system, especially with low pressure carbon dioxide. Technical standards for carbon dioxide systems do not give detailed guidelines for discharge tests at present. Based on comparative analysis of standards and practical tests, this paper suggests a methodology for on-site discharge tests.

Field Test on IEC60364-4-44 for the Application in Korean distribution system (IEC60364-4-44의 국내 배전계통 적용을 위한 실증시험)

  • Nam, Kee-Young;Choi, Sang-Bong;Jeong, Seong-Whan;Lee, Jae-Duck;Ryoo, Hee-Suk;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.486-487
    • /
    • 2006
  • The authors have studied on the application of IEC 60364-4-44 to Korean electrical installations of buildings from 2004 sponsored by Korean ministry of commerce, industry and energy and the test field is established in K.E.R.I. (Korea Electrotechnology Research Institute). This paper presents the summary results of establishment of test field and analysis for the application of IEC 60364 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use and production of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, since Korean electric power distribution system is based on multi-grounding system different from European system, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a Korean standard. This paper presents the establishment of test field to get background data to introduce the IEC 60364-4-44 and to evaluate the standard is applicable to domestic rule for the protection against ground fault through the related test

  • PDF

Evaluation of Invasive and Noninvasive Methods for the Diagnosis of Helicobacter Pylori Infection

  • Cosgun, Yasemin;Yildirim, Abdullah;Yucel, Mihriban;Karakoc, Ayse Esra;Koca, Gokhan;Gonultas, Alpaslan;Gursoy, Gul;Ustun, Huseyin;Korkmaz, Meliha
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.12
    • /
    • pp.5265-5272
    • /
    • 2016
  • Objective: The present study was conducted to evaluate invasive and noninvasive diagnostic methods for detection of Helicobacter pylori (H. pylori) in patients admitted with dyspeptic complaints and to compare sensitivities and specificities. Method: Sets of four gastric biopsy specimens were obtained from a total of 126 patients included in the study. The presence of H. pylori was determined by invasive tests including culture, rapid urease test, polymerase chain reaction (PCR) and histopathology. Among noninvasive tests, urea breath test, serological tests and enzyme-linked immunosorbent assay (ELISA) were performed. Results: H. pylori was isolated in 79 (62.7%) gastric biopsy cultures, whereas positivity was concluded for 105 (83.3%) patients by rapid urease test, for 106 (84.1%) by PCR, for 110 (87.3%) by histopathology, for 119 (94.4%) by urea breath test, and for 107 (84.9%) by ELISA. In the present study, the culture findings and histopathological examination findings were accepted as gold standard. According to the gold standard, urea breath test had the highest sensitivity (96.5%) and the lowest specificity (30%), whereas culture and histopathology had the highest specificities (100%). Conclusion: The use of PCR invasively with gastric biopsy samples yielded parallel results with the gold standard. PCR can be recommended for routine use in the diagnosis of H. pylori.

Development of Dynamic Cone Penetration Tester Module for Slope Vulnerability Assessment and Correlation of Its Results with Standard Penetration Test Values (비탈면 취약도 평가를 위한 동적콘관입시험기 모듈개발과 표준관입시험값과의 상관관계 연구)

  • Chae, Hwi-Young;Kwon, Soon-dal
    • The Journal of Engineering Geology
    • /
    • v.31 no.4
    • /
    • pp.541-547
    • /
    • 2021
  • To assess the stability of a slope and the likelihood of its loss or collapse requires information about the ground, such as the composition of the stratum and its mechanical characteristics. This information is generally gathered through standard penetration testing (SPT) and cone penetration testing. SPT is not widely used due to problems with accessing slopes, most of which are steep and without ramps. A drop cone penetrometer, a portable device that can make up for these shortcomings, can be used in a limited way in some circumstances. Therefore, we developed a portable drilling machine and a small dynamic cone penetration test module that can easily access a slope site and perform SPT. The correlation of the developed system's results with those from SPT was analyzed. Analysis of the correlation between the energy shear rate passing to the load during the different test types established that the energy shear rate is reflected in the test result. The correlation between corrected dynamic cone penetration testing and corrected SPT was Nd' = 3.13 N'.

A NEW VERSION OF FIRST RETURN TIME TEST OF PSEUDORANDOMNESS

  • Kim, Dong-Han
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.12 no.2
    • /
    • pp.109-118
    • /
    • 2008
  • We present a new version of the first return time test for pseudorandomness. Let $R_n$ be the first return time of initial n-block with overlapping. An algorithm to calculate the probability distribution of the first return time $R_n$ for each starting block is presented and used to test pseudorandom number generators. The standard Z-test for log $R_n$ is applied to test the pseudorandom number generators.

  • PDF

A Study on Torque Efficiency Test Method of Tandem Pump (탠덤 펌프의 토크효율 시험방법에 관한 연구)

  • 유진산;함영복;김성동
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.282-285
    • /
    • 1997
  • The torque efficiency of oil hydraulic pump is an important factor for it's performance characteristics. A study on the performance test method of oil hydraulic pump is based on test standard, but there is to be desired an study for double or tandem type oil hydraulic piston pump. So in this study present a test method on the tandem pump for torque efficiency and analysis method of the results.

  • PDF

Study on the cable fire test for Train (철도차량용 전선의 화재안전기준 조사)

  • Lee, Duck-Hee;Lee, Kwan-Sub;Jung, Woo-Sung;Lee, Cheul-Kyu
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1119-1124
    • /
    • 2008
  • Defect of the Cable is one of the most frequent cause of fire accident for years. It also take a big part of the fire load for train. In this study, we reviewed the standard code of other countries for cable fire test. Oxygen index, flame propagation test, smoke test and toxicity test codes were investigated. We also suggest the our national code for train cables.

  • PDF