• Title/Summary/Keyword: test specimens

Search Result 6,469, Processing Time 0.032 seconds

Influence of Compressive Strength of Concrete Affected by fixed test Specimens and moved test Specimens (운반된 공시체가 콘크리트의 압축강도에 미치는 영향)

  • 조일호;양재성;김성욱
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.957-960
    • /
    • 2000
  • The purpose of this study was performed to estimate the influence of compressive strength of the concrete according to change test specimens of concrete were investigated by measurements of slump, air content and compressive strength. As a result, according to moved test specimens, the compressive strength, fiexed test specimens effected on Concrete compressive strength, test specimens than moved test specimens, increased 4∼10% fixed test specimens, 2∼9% moved test specimens.

Diagnostic Accordance Rate and Accuracy Between Cytological and Histological Test in Lung Disease (폐질환에 있어 세포검사와 조직검사의 진단 일치율 및 정확도에 대한 조사 연구)

  • Kim, Sung-Chul;Ro, Joung-Whan;Kim, Tai-Jeon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.4
    • /
    • pp.189-195
    • /
    • 2009
  • Lung cancer is a type of cancer with high mortality; its 5-year survival rate is at a low 14%. Related cytological tests include sputum, bronchial brushing, bronchial washing and fine needle aspiration cytology test etc. From the test specimens in which sputum, bronchial brushing, bronchial washing, and fine needle aspiration cytology were performed, the sensitivity, specificity and accuracy between cytology test and histology test. In the sputum test, sensitivity was 27.71% and specificity was 98.02%, and the bronchial brushing test showed sensitivity of 93.33% and a specificity of 91.3%. The bronchial washing test was a sensitivity of 53.7% and its specificity was 98.9%, and the fine needle aspiration cytology test showed sensitivity and specificity were 88.46% and 72.97%, respectively. In the specimens diagnosed as normal at the sputum test, malignant diagnosis was found in 21 specimens of bronchial brushing, 30 cases of bronchial washings and 37 cases of fine needle aspiration cytology specimens. In the specimens diagnosed as normal at the bronchial washing test, malignant diagnosis was found in 5 specimens of sputum, 7 specimens of bronchial brushin and 1 cases of fine needle aspiration cytology. One specimens found to be normal in fine needle aspiration cytology turned out to maligant in sputum test. The result of this research shows that, in diagnosis lung cancer, a test method of high sensitivity and specificity should be pursued. However, depending on the location and malignancy of the illness, diagnosis may not be obtained in some cases. Therefore, we conclude that the cytological tests performed for lung cancer testing such as sputum, bronchial brushing, bronchial washing, and fine needle aspiration cytology should be carried out in a mutually complementary manner.

  • PDF

Bond behavior investigation of ordinary concrete-rebar with hinged beam test and eccentric pull-out test

  • Arslan, Mehmet E.;Pul, Selim
    • Computers and Concrete
    • /
    • v.26 no.6
    • /
    • pp.587-593
    • /
    • 2020
  • In this study, bond behavior of ordinary concrete and rebars with different diameters and development length was investigated by using Hinged Beam Test (HBT) and Eccentric Pull-Out Test (EPT) comparatively. For this purpose, three different rebar size and development length depending on rebar diameter were chosen as variables. Three specimens were produced for each series of specimens and totally 54 specimens were tested. At the end of the tests it was observed that obtained results for both tests were quite similar. On the other hand, increased bar size, especially for the specimen with 14 mm bar size and 14 development length (lb), caused shear failure of test specimens. This situation infers that when bigger bar size and lb are used in such test, dimensions of test specimens should be chosen bigger and stirrups should be used for producing of test specimens to obtain more adequate result by preventing shear failure. Also, a nonlinear regression analysis was employed between HBT and EPT results. There was a high correlation between the EPT values, lb, rebar diameters and estimated theoretical HBT. In addition, at the end of the study an equation was suggested to estimate bond strength for HBT by using EPT results.

Effects of a new stirrup hook on the behavior of reinforced concrete beams

  • Zehra Sule Garip;Furkan Erdema
    • Structural Engineering and Mechanics
    • /
    • v.91 no.3
    • /
    • pp.263-277
    • /
    • 2024
  • The primary aim of this study is to introduce an innovative configuration for stirrup hooks in reinforced concrete beams and analyze the impact of factors such as stirrup spacing, placement, and hook lengths on the structural performance of reinforced concrete beam elements. A total of 18 specimens were produced and subjected to reversed cyclic loading, with two specimens serving as reference specimens and the remaining 16 specimens utilizing a specifically developed stirrup hook configuration. The experiment used reinforced concrete beams scaled down to half their original size. These beams were built with a shear span-to-depth ratio of 3 (a/d=3). The experimental samples were divided into two distinct groups. The first group comprises nine test specimens that consider the contribution of concrete to shear strength, while the second group consists of nine test specimens that do not consider this contribution. The preparation of reference beam specimens for both groups involved the utilization of standard hooks. The stirrup hooks in the test specimens are configured with a 90-degree angle positioned at the midpoint of the bottom section of the beam. The criteria considered in this study included the distance between hooks, hook angle, stirrup spacing, hook orientation, and hook length. In the experimental group examining the contribution of concrete on shear strength, it was noted that the stirrup hooks of both the R1 reference specimen and specific test specimens displayed indications of opening. However, when the contribution of concrete on shear strength was not considered, it was observed that none of the stirrup hooks proposed in the R0 reference specimen and test specimens showed any indications of opening. Neglecting the contribution of concrete in the assessment of shear strength yielded more favorable outcomes regarding structural robustness. The study found that the strength values obtained using the suggested alternative stirrup hook were similar to those of the reference specimens. Furthermore, all the test specimens successfully achieved the desired strengths.

Pseudo Dynamic Test Research on the Seismic Performance of RC Bridge Piers Retrofitted with Fiber Sheet (섬유보강 RC교각의 내진성능에 관한 유사동적실험 연구)

  • 박종협;박희상;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.559-564
    • /
    • 2001
  • The objective of this experimental research is to assess the seismic performance of circular RC bridge pier specimens retrofitted with fibers which were designed as a prototype of Hagal bridge in the city of Suwon, Korea. Pseudo-dynamic test has been done for two nonseismic test specimens which were nonseismic designed by the related provisions of the Highway Design Specification, and four nonseismic test specimens retrofitted with fibers in the plastic hinge region. Important test parameters were load patterns, and retrofit. The seismic behavior has been analyzed through the displacement ductility, energy analysis, and capacity spectrum. Approximate 7.0 displacement ductility was observed for nonseismic test specimens retrofitted with fibers. It is concluded that these retrofitting test specimens could have sufficient seismic capacity in the region of moderate seismic zone.

  • PDF

Evaluation of Curvature Analysis at RC Bridge Piers in an aspect ratio of 2.5 (형상비 2.5 RC 교각의 곡률분석평가)

  • 박창규;정영수;이은희;김영섭
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.263-270
    • /
    • 2003
  • Before the implementation of the 1992 seismic design provisions in Korea, longitudinal steels of RC bridge piers were practically lap-spliced in the plastic hinge region. Experimental investigation was made to evaluate the seismic performance of RC bridge pier specimens in a flexure/shear mode. Six circular test specimens in an aspect ratio of 2.5 (600mm in diameter) were made with test parameters confinement ratio, lap splices, and retrofit FRP materials. They were damaged under a series of artificial earthquakes with 0.22g PGA, being compatible in Korean peninsula, through the pseudo-dynamic test. Probable damages were assessed by the Park and Ang damage index. Approximate 0.1 and 0.3 damage indices were obtained for RC specimens without lap splice and with lap splice, respectively. Directly after the pseudo-dynamic test, damaged test columns were laterally actuated under inelastic reversal cyclic loadings simultaneously under a constant axial load. Through curvature measurements, residual seismic performance was evaluated for test specimens. Test results show that RC pier specimens with lap-spliced appeared to fail at low ductility, but significant improvement was obtained for the ductility of these specimens if externally wrapped with FRP.

  • PDF

Evaluation of Adhesion Performance of Stones Bonded with Epoxy according to Environmental Conditions (환경조건에 따른 에폭시로 접착된 석재의 부착성능평가)

  • Kim, Young-Min;Im, Geon-Woo;Lim, Chang-Min;Lee, Gun-Cheol;Oh, sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.39-40
    • /
    • 2023
  • Recently, due to the advancement of buildings, finishing methods using stone are increasing. However, finishing methods are not standardized and rely on workers' arbitrary methods. In stone finishing, many building defects occur due to adhesion performance, so the adhesion performance of stones attached with epoxy is important. Therefore, in this study, the adhesion performance of stones attached with epoxy was evaluated by exposing them to various environments. As a result of the experiment, the test specimens exposed to thermal shock showed only 20% of the standard test specimens' adhesion performance, and the test specimens cured at high and low temperatures showed the standard test specimens. It was expressed in 65-80% of the test specimens. Therefore, the adhesion performance of stone using epoxy was found to be vulnerable to repeated harsh environments.

  • PDF

Failure Behaviors Depending on the Notch Location of the Impact Test Specimens on the HAZ (용접열영향부 충격시험편 노치 위치에 따른 파괴거동)

  • Jang, Yun-Chan;Hong, Jae-Keun;Park, Ji-Hong;Kim, Dong-Wook;Lee, Young-Seog
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.706-711
    • /
    • 2007
  • Numerical studies were performed to examine the effects of notch location of impact specimens on the failure behavior of HAZ (heat affected zone) when Charpy V-notch impact test were made at a low temperature ($1^{\circ}C$). Carbon steel plate (SA-516 Gr. 70) with thickness of 25mm for pressure vessel was welded by SMAW (shielded metal-arc welding) and specimens were fabricated from the welded plate. Charpy tests were then performed with specimens having different notch positions of specimens varying from the fusion line through HAZ to base metal. A series of finite element analysis which simulates the Charpy test and crack propagation initiating at the tip of V-notch was carried out as well. The finite element analysis takes into account the irregular fusion line and non-homogenous material properties due to the notch location of the specimen in HAZ. Results reveals that the energies absorbed during impact test depend significantly on the notch location and direction of specimen. Finite element analysis also demonstrates that the notch location of specimens, to a great extent, influences the reliability and consistency of the test.

  • PDF

Cyclic Loading Test of Anchorage System for Externally Prestressed CFRP Plate (외부긴장 CFRP판용 정착부의 반복하중 실험)

  • Jung, Woo-Tai;Park, Jong-Sup;Park, Young-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.262-265
    • /
    • 2006
  • This paper presents results on static and cyclic loading tests of anchorage system for externally prestressed CFRP plate. A total of 6 specimens have been tested. The specimens can be classified into the concrete surface specimens and the concrete near surface mounted specimens. Static test results before and after cyclic loading test reveal that anchorage system for externally prestressed CFRP plate has static capacity more than CFRP tensile strength.

  • PDF

A Study on Shear Strength of Composite Ground with Triaxial Test (삼축압축시험을 통한 복합지반의 전단강도에 관한 연구)

  • 신희범;이상익;박용원;김병일
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.569-576
    • /
    • 2000
  • This study performs a series of Triaxial Compression Test for clay-sand composite specimens changing area replacement ratio. Purpose of the test is to conform the propriety of weighted average method in estimating shear strength of the composite ground. The test results show that measured values of shear strength of composite specimens are larger by 20∼30% than those from estimation using the current weighted average method. It is thought that the differences are from pseudo-overconsolidation behavior of composite specimens.

  • PDF