• Title/Summary/Keyword: test method

Search Result 32,202, Processing Time 0.056 seconds

An Automatic Test Case Generation Method from Checklist (한글 체크리스트로부터 테스트 케이스 자동 생성 방안)

  • Kim, Hyun Dong;Kim, Dae Joon;Chung, Ki Hyun;Choi, Kyung Hee;Park, Ho Joon;Lee, Yong Yoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.8
    • /
    • pp.401-410
    • /
    • 2017
  • This paper proposes a method to generate test cases in an automatic manner, based on checklist containing test cases used for testing embedded systems. In general, the items to be tested are defined in a checklist. However, most test case generation strategies recommend to test a system with not only the defined test items but also various mutated test conditions. The proposed method parses checklist in Korean file and figures out the system inputs and outputs, and operation information. With the found information and the user defined test case generation strategy, the test cases are automatically generated. With the proposed method, the errors introduced during manual test case generation may be reduced and various test cases not defined in checklist can be generated. The proposed method is implemented and the experiment is performed with the checklist for an medical embedded system. The feasibility of the proposed method is shown through the test cases generated from the checklist. The test cases are adequate to the coverages and their statistics are correct.

Dynamic Fracture Testing of Welding part of Nuclear Piping by Using Normalization Method (정규화법을 이용한 원전배관 용접부의 동하중 파괴저항시험)

  • Huh, Yong;Cho, Sung-Keun;Park, Jae-Sil;Seok, Chang-Sung
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.262-267
    • /
    • 2004
  • The unloading compliance method is the most commonly used method to evaluate the fracture resistance characteristics of a material. In dynamic loading condition, the direct current potential drop(DCPD) method has been used because the unloading compliance method can not be applied due to the discontinuity of loading. However, even in the dynamic test using DCPD method, there is a problem that the voltage drops sharply on the initiation of crack. For the reason metioned above, the normalization method was suggested on ASTM E 1820 which is revised recently, as a new method to evaluate the dynamic fracture resistance characteristic. The nomalization method can be used to obtain a fracture resistance curve directly from a load-load line displacement. In this study, we obtained two fracture resistance curves from static test of welding part of nuclear piping both by unloading compliance and nomalization method. The two curves were almost same each other, so the adaptability of the nomalization method has been proved. We conducted a dynamic fracture resistance test for the same material. The fracture resistance curve from the dynamic test was obtained by normalization method and compared to that of the static test result.

  • PDF

Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent (계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가)

  • Cho, Han-Goo;Han, Dong-Hee;Lee, Un-Yong;Lim, Kee-Joe;Choi, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1121-1124
    • /
    • 2004
  • Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. The diagnosis methods in off-line most are the method for virgin and last aged sample. However, the diagnosis method in on-line is method that can be evaluate sample state as progressing continuously aging test in beginning, The diagnosis method in on-line is arranged as following: leakage current measurement, electric field, surface state investigation, thermal image, emitting light measurement and then so. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination.

  • PDF

The Evaluation of Sewability for Sewing Threads -In Relation to the Breakage of Sewing Threads During Sewing Operation- (재봉사의 가봉성 평가 -재봉사의 사절을 중심으로-)

  • Jang, Jeong-Dae
    • Fashion & Textile Research Journal
    • /
    • v.1 no.2
    • /
    • pp.154-159
    • /
    • 1999
  • In this study, for different test methods of the performance of sewing threads were used to evaluate the sewability of 10 different industrial threads. Sewability evaluations related to the breakage of thread during sewing operation were investigated by seam length and fabric thickness method (Test 1), thread tension method (Test 2), strength retention method (Test 3), and backward sewing method(Test 4), and discussed. Two of the methods, Test 1 and Test 2, simulated very harsh sewing conditions which each thread could accept as an evaluation of its sewability. Core spun thread ranked with the best sewability generally and followed by air jet textured (ATY) thread. Spun thread was superior to the filament thread in sewing thread type. In general, there was a high degree of correlation in the results of Test 1 and Test 2. The order of sewing thread by sewability test 1 was polyester spun thread, cotton thread, and p/c core spun thread. The order of sewing thread by test 2 was polyester spun thread, and p/c core spun thread. Cotton threads and cotton blended threads performed better in Test 3, and ATY threads and core spun threads in Test 4.

  • PDF

Test Method of an Embedded CMOS OP-AMP (내장된 CMOS 연산증폭기의 테스트 방법)

  • 김강철;송근호;한석붕
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.1
    • /
    • pp.100-105
    • /
    • 2003
  • In this paper, we propose the novel test method effectively to detect short and open faults in CMOS op-amp. The proposed method uses a sinusoidal signal with higher frequency than unit gain bandwidth. Since the proposed test method doesn't need complex algorithm to generate test pattern, the time of test pattern generation is short, and test cost is reduced because a single test pattern is able to detect all target faults. To verify the proposed method, CMOS two-stage operational amplifier with short and open faults is designed and the simulation results of HSPICE for the circuit have shown that the proposed test method can detect short and open faults in CMOS op-amp.

Standardization of Impact Test Methods of Non-bearing Lightweight Wall for Building (건축용 비내력 경량벽체의 내충격성 시험방법의 표준화)

  • Kim, Ki-Jun;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.181-182
    • /
    • 2015
  • The use of non-bearing light weight wall has increased recently due to the increase of high-rise buildings and supply of long-life housing. Light weight wall has advantages such as reducing the self-weight of the building, convenience in installation, and shortening construction period, however, must have a sufficient strength to external force. This study standardized the impact resistance test method for light weight walls by using the actual impact load obtained through load analysis test in previous studies. The impact resistance test method was divided into the test method that uses soft body and the one that uses hard body. The size of specimen was set up as height 2.4m and width 3.0m. The size and shape of the body followed those used in BS 5234-2 and so on for the compatibility with the test method used overseas. The judgment criteria for impact resistance based on test results were not defined uniformly as the assessment of functional damage can vary depending on the type of material, structural method, purpose of wall, and so on even when the same impact load was applied.

  • PDF

The Compressive Strength Prediction of Crushed Sand Concrete by Non-Destructive Test Method (부순모래 콘크리트의 비파괴 시험에 의한 압축강도 추정)

  • Kim, Myung-Sik;Jang, Hei-Suk;Beak, Dong-Il;Sin, Nam-Gyun;Kim, Kang-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.145-148
    • /
    • 2006
  • Schmidt hammer and ultra-sonic method are commonly used for crushed sand concrete compressive strength test in a construction field. At present, various of equations for prediction of strength are present, which have been used in a construction field. The purpose of this study is to evaluate the correlation between prediction strength by presentation equations and destructive strength to test specimen, and find out which is a suitable equation for the construction site, In this study, a strength test was carried out destructive test by means of core sampling and traditional test. Non-destructive test was conducted Schmidt hammer and ultra-sonic method, the experimental parameter were concrete age, curing condition, test method and strength level. It is demonstrated that the correlation behavior of crushed sand concrete strength in this study good due to the perform analysis of correlation between core, destructive strength and non-destructive strength.

  • PDF

The high altitude test method of Scramjet engine combustor model (스크램제트 연소기 모델의 고공시험 연구)

  • Woo Kwan Je;Kim Young Soo;Skivin V. A
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.271-274
    • /
    • 2002
  • This paper is investigated construction of the Scramjet test facility and test method of Scramjet engine combustor model. Scramiet engine combustor model test was performed at Lab C-16BK CIAM (Central Institute of Aviation Motors) at Tyraevo in Moscow. The velocity of flow in the combustion chamber equal to Mach number 2.49 with single hole fuel spray nozzle injector and test duration equal to 7 seconds. Therefore In this paper is showed high altitude test method of Scramjet combustor model and the proper structure of combustor with single hole fuel spray nozzle.

  • PDF

Confirmation of particle crushing on the vibrating table test of artificial sand (인공모래에 대한 진동대 시험시 입자파쇄 현상 확인)

  • Cho, Yong-Soon;Kim, Rae-Hyun;Kim, Jae-Jung;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1391-1398
    • /
    • 2009
  • The vibrating table method is widely used to estimate the minimum void ratio $e_{min}$. The existing method recommended in ASTM and KS F, however, can not consider the particle crushing during the vibrating table test. In this study, the particle cursing phenomenon was investigated by comparing vibrating table test with pluviation method using artificial sand (K-7). Vibrating table test for the artificial sand was confirmed which can crush of particle during the test. This study demonstrates that vibrating table test is an ineffective method to produce the more reliable $e_{min}$ of artificial sand.

  • PDF

Measurements of the Ground Resistance using the Test Current Transition Method in Powered Grounding Systems (측정전류전이법을 이용한 운전중인 접지시스템의 접지저항 측정)

  • Lee, Bok-Hui;Eom, Ju-Hong;Kim, Seong-Won
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.8
    • /
    • pp.347-353
    • /
    • 2002
  • This paper presents an accurate method for measuring the ground resistance in powered grounding system. Most of substations and electric power equipments are interconnected to an extensive grounding network of overhead ground wires, neutral conductors of transmission lines, cable shields, and etc. The parasitic effects due to circulating ground currents and ground potential rise make a significant error in measuring the ground resistance. The test current transition method was proposed to reduce the effects of stray ground currents, ground potential rise and harmonic components in measurements of the ground resistance for powered grounding systems. The instrumental error of the test current transition method is decreased as the ratio of the test current signal to noise(S/N) increases. It was found from the test results that the proposed measuring method of the ground resistance is more accurate than the conventional fall-of-potential method or low-pass filter method, and the measuring error was less than 3[%]when S/N is 10.