• Title/Summary/Keyword: test device

Search Result 3,544, Processing Time 0.034 seconds

Workpiece-Chucking Device Using Two-Way Shape Memory Alloys: Feasibility Test (양방향성 형상기억합금을 이용한 공작물 척킹장치: 유용성 검증)

  • Shin, Woo-Cheol;Ro, Seung-Kook;Park, Jong-Kweon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.5
    • /
    • pp.462-468
    • /
    • 2009
  • In this study, a workpiece-chucking device that generates a chucking force from a shape memory alloy is introduced. This paper first presents train procedure to transform a commercial one-way shape memory alloy into a two-way shape memory alloy, which makes unclamping mechanism of the chucking device simpler than that using the one-way shape memory alloy Second, it describes a conceptual design of the workpiece-chucking device using the two-way type shape memory alloy. Third, it presents a prototype and its chucking characteristics, such as time-response of clamping/unclamping operations and a relationship between temperatures and chucking forces. Finally, it describes a mill-machining test conducted with the prototype. The results confirm that the proposed workpiece-chucking device is feasible for micro machine-tools.

  • PDF

Experiments on Development A Pulse-Gun Pressure-Wave Inducing Device for Stability Rating Test Technique (연소안정성 평가시험 기법을 위한 펄스건 압력파 유도장치 개발 실험)

  • Lee, Kwang-Jin;Kim, Hong-Jip;Seo, Seong-Hyeon;Moon, Il-Yoon;Kim, Hyung-Mo;Lee, Soo-Yong;Ko, Young-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.99-106
    • /
    • 2005
  • The SRT(stability rating test) technique, which is indispensable for the development of a LRE(liquid rocket engine), essentially requires a development of a combustion test sequence as well as artificial perturbation devices. For the development of an indigenous SRT technique, several combustion tests of sub-scale LRE were performed to search a proper combustion test sequence. At first, a pressure-wave inducing device which is used for adapting pulse gun was designed and a cooling gas supply system for the pressure-wave inducing device was set up to prevent a malfunction of pulse gun. Through the several combustion tests which included cooling procedure of a pressure-wave inducing device, a proper combustion test sequence was found out. It did not make any significant disturbance at normal combustion process. Finally, an indigenous SRT technique has been developed successfully.

A study of an efficiency test for new style rail fastening system (신형레일체결장치의 성능평가)

  • Kim, Eun;Yang, Shin-Chu;Lee, Jong-Duk
    • Proceedings of the KSR Conference
    • /
    • 2001.10a
    • /
    • pp.494-499
    • /
    • 2001
  • This research carried out the experimental manufacture of the improved fastening device and its performance test as well as the structural improvement of the prototype of a new type of fastening device developed through G7 Project during the first year of the second phase. Firstly, a supplementary design for each part of the prototype was carried out in order to improve its performance and a structural analysis in order to review the stress on the fastening spring. Secondly, another prototype was manufactured and then a performance test was carried out with the criteria used for the same kind of test on the authorized ones, both at home and abroad. Finally, the usability of the device was reviewed by comparing above-mentioned test result with that of those already under commercial use.

  • PDF

A Design and Implementation of a Mobile Test Device Based-on Embedded System (임베디드 기반의 모바일 LCD 모듈 검사장비 설계 및 구현)

  • Kim, Hong-Kyu;Lee, Ki-Wha;Moon, Seung-Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.6
    • /
    • pp.523-529
    • /
    • 2008
  • In this paper, we proposed mobile LCD module test device on embedded based, when operating the existing LCD, divide flicker clearly in full frame, and configuration so as to support between other CPU interface, MDDI, SPI, 24Bit RGB interface, etc. that is based on a high-speed CPU. In addition, when demand to test about each pixel of LCD, it is possible to change IP design of H/W, FPGA, but proposed system is application possible without other design changing. Proposed system is made smaller and equipped with battery, so secure with mobility for effective test the LCD/OLED module and it is able to test the pattern by the client program, for example exiting picture, mpeg, simple pattern test and test per pixel, scale, rotation, Odd/Even pixel per video, etc. From now on, if integrating with independent test system and it is configured that is able to mutual communication and test, it is expected to reduce consumption of human resources and improve productivity for LCD module test.

Capacity evaluation on the slitting device of the spent fuel rod (사용후핵연료봉 slitting 장치 성능 평가)

  • 정재후;윤지섭;김영환;진재현;김동기
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1154-1157
    • /
    • 2003
  • The spent fuel slitting device is an equipment developed for the separation of the pellet and hull from the cutting fuel rod with length of 250 mm, and in order to feed UO$_2$ pellet. We have analyzed on the existing technologies for designing and producing of the slitting device in the first year(2001), based on these results, designed and produced the rod slitting device. It has effectively separated the pellet from the hull, but demanded the supplement separation work because of the mixing with pellet and hull in the vessel, and required the condition for the reducing time of the process. In the second year(2002), we have reduced the work time, performed the test and capacity evaluation with the improving device, based these results, and ensured the data demanded for designing of the spent fuel rod slitting device. We have compared with the DUPIC(Direct use of spent PWR fuel in CAND reactors) process, and developed the device for the purpose of reducing over 40 % in comparition with the DUPIC operation time(5 minutes). Based on these results, it will is effectively applied to available data for designing and producing of the hot test facility.

  • PDF

A Study on the Application of Risk Management for Medical Device Software Test (의료기기 소프트웨어 테스트 위험관리 적용 방안 연구)

  • Kim, S.H.;Lee, jong-rok;Jeong, Dong-Hun;Park, Hui-Byeong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.495-497
    • /
    • 2012
  • Development of application risk management for medical device software test. First, Through questionnaires, Medical device manufacturers, Analysis of software validation and risk management status. Second, Analyzed by comparing the difference between black box testing and white box testing. Third, After analyzing the potential for software analysis tools using code derived factors were quantified, Finally, Medical device risk management process so that it can be applied to build the framework by FMEA(Failure Mode and Effect Analysis) technique. Through this Difficult to build software validation and risk management processes for manufacturers to take advantage of support in medical device GMP(Good Manufacture Practice).

  • PDF

Non-explosive separation device using screw jack mechanism (나사잭 메커니즘을 이용한 비폭발식 분리장치)

  • Park, Hyun-Jun;Lee, Min-Su;Jo, Jae-Wook;Kim, Byung-Kyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.4
    • /
    • pp.321-326
    • /
    • 2010
  • The non-explosive release device using jack mechanism is designed and fabricated for the small satellite. As a triggering actuator for the release device, a piezo rotory motor with torque of more than $1.7kgf{\cdot}cm$ is employed to guarantee stable activation. For performance tests of separation device, we conducted release time test, preload test and shock test. The device was operated within 1.172sec and activated stably under load of 45kgf. Maximum shock was measured as 18G that is much less than the pyro-separation device produces. We confirmed the possibility as a satellite separation device through above presented tests.

Development of the Safety Steering System of Motor Vehicles Transmission (차량용 변속기의 조향안전화 제어장치의 개발)

  • 송창섭
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.4 no.2
    • /
    • pp.12-17
    • /
    • 1995
  • The operation of heavy tracked vehicle has the problems in the steering that made by misoperations. The protection device is applied to the vehicles. But that device is applied to the vehicles. But that device has the engine stop and over load condition problems. the steering safety system is developed on the basis of clutch slip that proved the durability in the dynamo test and field test. The steering safety system caused the performance improvement of vehicles when steering.

  • PDF

A Study on OLED display device's line defect test methode (OLED display device의 Line Defect 시험법에 관한 연구)

  • Choi, Young-Tae;Choi, Jai-Rip
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.04a
    • /
    • pp.523-529
    • /
    • 2009
  • The ACF(Anisotropic Conductive Film) is used for bonding Drive IC and OLED display device panel. If ACF bonding process is problem, a malfunction of line defect can occur. Because electric resistance increase between the panel and drive IC after a period of time, drive IC can not supply enough current to the panel. This paper is studied on a method of test for line defect.

  • PDF

A new approach for measurement of anisotropic tensile strength of concrete

  • Sarfarazi, Vahab;Faridi, Hamid R.;Haeri, Hadi;Schubert, Wulf
    • Advances in concrete construction
    • /
    • v.3 no.4
    • /
    • pp.269-282
    • /
    • 2015
  • In this paper, a compression to tensile load converter device was developed to determine the anisotropic tensile strength of concrete. The samples were made from a mixture of water, fine sand and cement, respectively. Concrete samples with a hole at its center was prepared and subjected to tensile loading using the compression to tensile load converter device. A hydraulic load cell applied compressive loading to converter device with a constant pressure of 0.02 MPa per second. Compressive loading was converted to tensile stress on the sample because of the overall test design. The samples have three different configurations related to loading axis; 0, $45^{\circ}$, $-45^{\circ}$. A series of finite element analysis were done to analyze the effect of hole diameter on stress concentration of the hole side along its horizontal axis to provide a suitable criterion for determining the real tensile strength of concrete. Concurrent with indirect tensile test, Brazilian test and three point loading test were also performed to compare the results from the three methods. Results obtained by this device were quite encouraging and show that the tensile strengths of concrete were similar in different directions because of the homogeneity of bonding between the concrete materials. Also, the indirect tensile strength was clearly lower than the Brazilian test strength and three point loading test.