• Title/Summary/Keyword: test device

Search Result 3,569, Processing Time 0.03 seconds

Results of Developing an ITS Device Performance Test-Bed and Criteria of Its Selection (ITS 장비 성능시험장 선정기준 및 구축결과)

  • Lee, Sang Hyup;Lee, Mi Young;Baik, Nam Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5D
    • /
    • pp.703-708
    • /
    • 2006
  • In the United States and Japan ITS device performance test-beds have been widely developed to enhance the reliability of traffic information and to expedite the standardization of components for securing the compatibility of device. In this study the selection criteria for developing ITS device performance test-bed are investigated by analyzing the cases and studies of overseas. Based on the criteria, a test-bed is developed and test-run. The importance of developing ITS device performance test-bed was identified as the result of reviewing the test run of each selection.

Verification for the design limit margin of the power device using the HALT reliability test

  • Chang, YuShin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.11
    • /
    • pp.67-74
    • /
    • 2018
  • The verification for the design limit margin of the power device for the information communication and surveillance systems using HALT(Highly Accelerated Life Test) reliability test is described. The HALT reliability test performs with a step stress method which change condition until the marginal step in a design and development phase. The HALT test methods are the low temperature(cold) step stress test, the high temperature(hot) step stress test, the thermal shock cyclic stess test, and the high temperature destruct limit(hot DL) step stress test. The power device is checked the operating performance during the test. In this paper, the HALT was performed to find out the design limit margin of the power device.

Design of the Memory Error Test Module at a Device Driver of the Linux (리눅스 디바이스 드라이버 내의 메모리 오류 테스트 모듈 설계)

  • Jang, Seung-Ju
    • The KIPS Transactions:PartA
    • /
    • v.14A no.3 s.107
    • /
    • pp.185-190
    • /
    • 2007
  • The necessity of error test module is increasing as development of embedded Linux device driver. This paper proposes the basic concept of freed memory error test module in the Linux device driver and designs error test module. The USB device driver is designed for freed memory error test module. I insert the test code to verify the USB device driver. I test the suggested error test module for the USB storage device driver. I experiment error test in this module.

Development of Arm Fire Device for Solid Rocket (고체 추진기관 점화안전장치 개발)

  • Jang Seung-Gyo;Jung Jin-Suk;Kim In-Suk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.169-172
    • /
    • 2005
  • The performance test result of the Arm Fire Device(Ignition Safety Device) for solid rocket which prevents accidental ignition was described. The results of the closed bomb test and the igniter test of the classical mechanical arm fire device and the advanced electro-mechanical arm fire device were presented, and according to the igniter test result it was realized that the electro-mechanical arm fire device has an advantage in aspect of the action time.

  • PDF

Development of Hydraulic Device Performance Test Equipment Automation Process (유압 디바이스 성능 검사 장비 자동화 공정 개발)

  • Kim, Hong-Rok;Chung, Won-Jee;Seol, Sang-Seok;Park, Sang-Hyeok;Lee, Kyeong-Tae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.10
    • /
    • pp.74-80
    • /
    • 2020
  • Crawler-type hydraulic devices facilitate forward and backward driving of construction equipment by converting power into mechanical energy. The existing hydraulic device performance test process is time- and labor-intensive. This study aims to improve efficiency and productivity by automating the hydraulic device production performance test processes, which have been separately conducted so far. We also used SolidWorksⓇ, a 3D modeling program, and ANSYSⓇ, a structural analysis tool, for structural analysis and to verify the suitability of fixing pins required for connecting a hydraulic device to performance test equipment. Our results that employing an automated hydraulic device performance test process improves efficiency.

Design of small impact test device for concrete panels subject to high speed collision

  • Kim, Sanghee;Jeong, Seung Yong;Kang, Thomas H.K.
    • Advances in concrete construction
    • /
    • v.7 no.1
    • /
    • pp.23-30
    • /
    • 2019
  • Five key items were used to create an economical and physically small impact test device for concrete panels subject to high speed collision: an air-compressive system, carbon steel pipe, solenoid valve, carrier and carrier-blocking, and velocity measurement device. The impact test device developed can launch a 20 mm steel spherical projectile at over 200 m/s with measured impact and/or residual velocity. Purpose for development was to conduct preliminary materials tests, prior to large-scale collision experiments. In this paper, the design process of the small impact test device was discussed in detail.

Performance Analysis of a Flow Passage Opening Device through Low Speed Aircraft Captive Flight Tests

  • Jung, Sung-Min;Park, Jeong-Bae
    • International Journal of Aerospace System Engineering
    • /
    • v.4 no.2
    • /
    • pp.5-9
    • /
    • 2017
  • In a pressurized fuel supply system of aircraft, a flow passage opening device is required to keep fuel continuously transferred from one tank to the other. The device utilizes balancing weights in order to follow up an acceleration at special conditions such as negative g. It is very difficult to test the device in a real high-speed and high-altitude test since severe test conditions and expensive supports are needed. Therefore, this paper deals with performance analysis of a flow passage opening device through low speed aircraft captive flight tests (CFT) including roll and negative-g maneuvers. It is shown that balancing weights in the device can open the passage in accordance with fuel position.

A Study on Development of Wireless Check-up Device for Captive Flight Test (탑재비행시험용 무선 점검장치 개발에 대한 연구)

  • Ryu, Sang-Gyu;Joo, Junghyun;Ko, Myoungjun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.501-508
    • /
    • 2019
  • In this paper, a study on a wireless check-up method of test equipment for captive flight test(CFT) was conducted. For CFT, test equipment is mounted on a POD, and check-up is carried on the test equipment's. For check-up the POD wirelessly, battery, power distribution unit, wireless communication devices were designed within the POD, and a check-up device is designed outside of the POD. Once the external check-up device sends a 'start signal' to the POD, it performs the overall check-up procedures and transmits the 'end signal' to the external check-up device. Detailed check-up results are stored in an internal storage device, and are possible to read from external check-up device if necessary, thereby improving the reliability of the wireless check-up. By implementing and applying these wireless check-up system, the reliability of the check-up was enhanced by dynamical and movable check-up, and safety is guaranteed as the check-up was carried without access to the aircraft.

Design of a Rule-Based Solution Based on MFC for Inspection of the Hybrid Electronic Circuit Board (MFC 기반 하이브리드 전자보오드 검사를 위한 규칙기반 솔루션 설계)

  • Ko Yun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.9
    • /
    • pp.531-538
    • /
    • 2005
  • This paper proposes an expert system which is able to enhance the accuracy and productivity by determining the test strategy based on heuristic rules for test of the hybrid electronic circuit board producted massively in production line. The test heuristic rules are obtained from test system designer, test experts and experimental results. The guarding method separating the tested device with circumference circuit of the device is adopted to enhance the accuracy of measurements in the test of analog devices. This guarding method can reduce the error occurring due to the voltage drop in both the signal input line and the measuring line by utilizing heuristic rules considering the device impedance and the parallel impedance. Also, PSA(Parallel Signature Analysis) technique Is applied for test of the digital devices and circuits. In the PSA technique, the real-time test of the high integrated device is possible by minimizing the test time forcing n bit output stream from the tested device to LFSR continuously. It is implemented in Visual C++ computer language for the purpose of the implementation of the inference engine using the dynamic memory allocation technique, the interface with the electronic circuit database and the hardware direct control. Finally, the effectiveness of the builded expert system is proved by simulating the several faults occurring in the mounting process the electronic devices to the surface of PCB for a typical hybrid electronic board and by identifying the results.

Study on the Fatigue Test and the Accelerated Life Test for Dental Implant using Universal-Joint Test Type (유니버설조인트 시험방식을 이용한 치과용 임플란트의 피로시험 및 가속수명시험에 관한 연구)

  • Do, Gyeong Hun;Lee, Seok Jin;Kim, Jong Mi;Kim, Sung Min
    • Journal of Applied Reliability
    • /
    • v.17 no.1
    • /
    • pp.50-57
    • /
    • 2017
  • Purpose : This paper is a comparative analysis results of the fatigue test for dental implants and accelerated life test by using a static type loading device commonly used in Korea and a dynamic type loading device (universal-joint) recommended by FDA. Methods : Fatigue tests of dental implant is based on ISO 14801 and classified into static load test and dynamic load test. The tests were carried out on three test specimens by four load stress steps under each loading device. For analysis on failure mode such as crack, fracture and permanent deformation of test specimens, we used X-ray three-dimensional computed tomography on test specimens before and after the fatigue tests. The design of the accelerated life test was based on the analysis results of the fatigue life data obtained from the dynamic load test and the statistical analysis software (Minitab ver.15) was used to analyze the appropriate life distribution. Results : As a result of the fatigue tests and the accelerated life tests at same acceleration condition under each test method, the fatigue life under the dynamic type loading device (universal-joint) was shorter than when static type loading device was applied. Conclusion : This paper can be used as a reference when the universal-joint type loading device for implants fatigue test is applied as ISO 14801.