• 제목/요약/키워드: ternary gas mixtures

검색결과 16건 처리시간 0.021초

3성분계 인화성 혼합가스의 최소점화에너지 측정에 관한 연구 (Measurement of Minimum Ignition Energy by Electrostatic Discharge for Flammable Ternary Gas Mixtures)

  • 최상원
    • 한국안전학회지
    • /
    • 제28권1호
    • /
    • pp.29-34
    • /
    • 2013
  • When flammable gases are mixed with air or oxygen in the explosion concentration range and are ignited by sufficiently large electrostatic discharge energy, they may explode causing severe disaster in workplace. The minimum ignition energy(MIE) of single gas-air mixtures has been already investigated by many research, but the MIE of mixtures of more than ternary gas mixture is not examined yet. The purpose of this study is to investigate the MIE of a ternary gas(methane, ethylene, hydrogen, propane) mixtures experimentally. The results of our experiment show that the ignition of a methane-ethylene-air, methane-hydrogen-air, methane-propane-air, ethylene-hydrogen-air, ethylene-propane-air and hydrogen-propane-air mixture due to electrostatic discharge energy primarily depends on that the mixture: the MIE decreases gradually with the increase of having the lower MIE than other mixture ratio in the normal atmospheric pressure.

3성분계 인화성 혼합가스의 MESG에 관한 연구 (A Study on the MESG of Flammable Ternary Gas Mixtures)

  • 황경용;변정환;이규남;이택기
    • 한국가스학회지
    • /
    • 제20권3호
    • /
    • pp.30-37
    • /
    • 2016
  • 내압 방폭전기기계 기구는 인화성 가스가 존재하는 위험장소에서 사용되어도 인화성 가스의 점화원이 되지 않는 구조로 이루어져야 한다. 또한 전기 스파크를 발생시키는 부품이 점화원이 되어 기계 기구 내부에서 폭발 시 최대 압력에 견디고 내부 화염이 외부로 전파되어 가스나 증기 폭발을 일으키지 않도록 설계되어야 한다. 본 연구에서는 화염 틈새를 통해 외부로 분사되는 연소 생성물의 분사가 외부 가스나 증기를 점화시킬 정도의 온도나 에너지를 가질 수 없도록 하는 MESG(Maximum Experimental Safe Gap)의 중요한 물리적인 메커니즘에 대해 규명하였다. IEC 60079-20-1:2010 기준에 의해 프로판- 아세틸렌-공기로 이루어진 3성분계 혼합가스의 MESG를 실험하여 MESG 값을 측정하고 가스 폭발시의 최대 폭발압력을 측정하였다. 결과로는 아세틸렌 가스 보다는 폭발력이 낮은 프로판 가스의 조성이 MESG 값과 폭발압력에 더욱 큰 변수로 작용함을 알 수 있었다.

Optimum Condition for Xe Gas Excitation in Plasma Display Panels through Ternary Gas of He, Ne, Xe

  • Khorami, Alireza;Ghanbari, Shirin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.744-747
    • /
    • 2009
  • Plasma Display Panels (PDPs) have illustrated impressive results in terms of light emission efficiency of the Ne-Xe mixture compared with the He-Xe mixture. However, He-Xe has shown to achieve superior color purity. This paper presents the optimization of excitation efficiency and color purity for He-Ne-Xe ternary gas mixtures. Furthermore, we investigate the effect that a protective dielectric layer has on UV photon efficiency in a matrix known as electrode type PDP.

  • PDF

Binary and ternary gas mixtures of He-Ne-Xe for improvement of vacuum ultraviolet luminous efficiency in ac-PDPs.

  • Jung, Kyu-Bong;Lee, Jun-Ho;Park, Won-Bae;Jeon, Wook;Oh, Phil-Young;Cho, Guang-Sup;Uhm, Han-Sup;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.522-524
    • /
    • 2004
  • The improvement of luminance and luminous efficiency is the one of the most important part in AC-PDPs. To achieve high luminance and luminous efficiency, high VUV emission efficiency is needed. We measured the emission spectra of vacuum ultraviolet(VUV) rays in surface discharge AC-PDP with binary and ternary gas mixtures of Ne-Xe and He-Ne-Xe. The influence of He-Ne-Xe gas-mixture ratio on excited $Xe^{\ast}$ resonant atoms and $Xe_2$$^{\ast}$ dimers has been investigated. It is found that luminous efficiency of ternary gas mixture, He-Ne-Xe, is shown to be much higher than that of binary gas mixture of Ne-Xe.

  • PDF

나트륨 아지드와 금속산화물과의 혼합물에 대한 열분해 특성 (Thermal Decomposition Characteristics on Sodium Azide and Metallic Oxide Mixtures)

  • 이내우;최재욱;박광수;설수덕;왕석주
    • 한국안전학회지
    • /
    • 제12권3호
    • /
    • pp.106-113
    • /
    • 1997
  • The thermal characteristics of two binary mixtures by sodium azide/manganese dioxide and ferric oxide, two ternary mixtures by sodium azide/silicon dioxide/manganese dioxide and ferric oxide were studied to obtain the basic data of gas-generating agents for air bags. The thermal reaction for all mixtures started at about $420^{\circ}C$, but the temperature at which the reaction rate reached a maximum was different with the states of samples. According to reaction results, nitrogen, nitrogen oxide and nitrogen dioxide were detected by GC-MS and so many kinds of new chemicals from sodium azide and metal oxide mixtures by XRD. NMS is considered as most stable and reasonable mixture for this types of gas-generating agents.

  • PDF

The characteristics of AC-PDPs According to binary and ternary gas mixtures of He-Ne-Xe_

  • Lee, H.J.;Son, C.G.;Lee, S.B.;Han, Y.K.;Jeoung, S.H.;You, N.L.;Lim, J.E.;Lee, J.H.;Moon, M.W.;Oh, P.Y.;Jeoung, J.M.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1195-1198
    • /
    • 2005
  • The improvement of efficiency is the one of the most important part in AC PDPs . To achieve high efficiency, high VUV emission efficiency and High ion induces secondary electron emission coefficient are needed. We have measured the emission spectra of vacuum ultraviolet rays and ion induced secondary electron emission coefficient of MgO protective layer in surface discharge AC-PDP with binary and ternary gas mixtures. We have investigated electro-optical characteristics of AC-PDPs to optimum gas mixture for high efficient.

  • PDF

PSA 공정에 의한 이성분 및 삼성분 혼합기체로부터 수소분리 (Hydrogen Separation from Binary and Ternary Mixture Gases by Pressure Swing Adsorption)

  • 강석현;정병만;최현우;안의섭;장성철;김성현;이병권;최대기
    • Korean Chemical Engineering Research
    • /
    • 제43권6호
    • /
    • pp.728-739
    • /
    • 2005
  • 활성탄을 흡착제로 이용한 2bed-6step PSA 공정에서 이성분 혼합기체 $H_2/Ar$(80%/ 20%)와 삼성분 혼합기체 $H_2/Ar/CH_4$(60%/ 20%/ 20%)의 수소 분리를 연구하였다. 비등온-비단열 상태에서 LRC 등온식과 LDF 모델을 고려하여 공정실험과 공정모사를 하였으며, 주기정상상태에 도달할 때까지 탑 내의 농도와 온도변화를 각각 알아보았다. 두 공정 모두에서 수소에 대한 순도 99%와 회수율 75%의 결과를 얻을 수 있었다. 이때, PSA 공정에 미치는 영향으로는 공급유량, 흡착압력 그리고 P/F ratio를 변수로 실험과 전산모사를 수행하여 결과를 비교하였다. 이 결과로부터, 다성분에서 최적의 공정조건을 결정에서 중요한 결정요인과 삼성분에서 최적의 공정조건을 알아보았다.

수평관내 3성분 혼합냉매의 강제대류비등 열전달 (Forced convective boiling heat transfer for a ternary refrigerant mixture inside a horizontal tube)

  • 오종택
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.912-920
    • /
    • 1999
  • The forced convective boiling heat transfer coefficients of R-407C were measured inside a horizontal tube 6.0mm I.D. and 4.0m long. The heat transfer coefficients increased according to an increase in heat flux at constant mass flux. Because nucleation was completely suppressed in the two-phase flow region with high quality, heat transfer coefficients in forced convective evaporation were higher than those in nucleate boiling region. Average heat transfer coefficients of R-407C were about 30 percent lower than the pure refrigerant correlation, due to mass transfer resistance at the gas-liquid interface. However, the total experimental data shows an agreement with the predicted data for ternary refrigerant mixtures with a mean deviation of 30%.

  • PDF

사성분계 시스템의 액액상분리에 관한 연구 (폴리술폰/폴리에테르술폰/NMP/물) (Liquid-Liquid Phase Separation in a Quaternary System of PolysuIfone/Polyethersulfone/N-Methyl-2-pyrrolidone/water)

  • 백기전;김제영;이환광;김성철
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 춘계 총회 및 학술발표회
    • /
    • pp.22-24
    • /
    • 1998
  • 1. INTRODUCTION : The phase inversion method is widely used to prepare a variety of polymeric membranes ranging from micro-filtration to gas separation. The final morphology obtained by immersion precipitation strongly reflects the thermodynamics and kinetics of the system involved. The equilibrium thermodynamics of the ternary system of polymer/solvent/ nonsolvent is still very important to understand and predict membrane structure. Polysulfone (PSf) and polyethersulfone (PES) are important polymers as membrane materials due to the chemical resistance, mechanical strength, thermal stability and transport properies. There are several reports on the experimental phase diagrams in ternary mixtures of PSf/solvent/nonsolvent, and PES/solvent/nonsolvent. It would be interesting to investigate the solution thermodynamics containing these two polymers since PES is slightly less hyclrophobic than PSf.

  • PDF

Multi-scale simulation of wall film condensation in the presence of non-condensable gases using heat structure-coupled CFD and system analysis codes

  • Lee, Chang Won;Yoo, Jin-Seong;Cho, Hyoung Kyu
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2488-2498
    • /
    • 2021
  • The wall film-wise condensation plays an important role in the heat transfer processes of heat exchangers, refrigerators, and air conditioner. In the field of nuclear engineering, steam condensation is often utilized in safety systems to remove the core decay heat under both transient and accident conditions. In particular, passive containment cooling system (PCCS), are designed to ensure containment safety under severe accident conditions. A computational fluid dynamics (CFD) scale analysis has been conducted to calculate the heat transfer rate of the PCCS. However, despite the increase in computing power, there are challenges in the long-term transient simulation of containment using CFD scale codes. In this study, a heat structure coupling between the CFD and system analysis codes was performed to efficiently analyze PCCS. In addition, the component unstructured program for interfacial dynamics (CUPID) was improved to analyze the condensation behavior of ternary gas mixtures. Thereafter, the condensation heat transfer on the primary side was calculated using the improved CUPID and CFD code, whereas that on the secondary side was simulated using MARS. Both the coupled codes were validated against the CONAN facility database. Finally, conjugate heat transfer simulations with wall condensation in the presence of non-condensable gases were appropriately performed.