• Title/Summary/Keyword: ternary gas mixtures

Search Result 16, Processing Time 0.027 seconds

Measurement of Minimum Ignition Energy by Electrostatic Discharge for Flammable Ternary Gas Mixtures (3성분계 인화성 혼합가스의 최소점화에너지 측정에 관한 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.29-34
    • /
    • 2013
  • When flammable gases are mixed with air or oxygen in the explosion concentration range and are ignited by sufficiently large electrostatic discharge energy, they may explode causing severe disaster in workplace. The minimum ignition energy(MIE) of single gas-air mixtures has been already investigated by many research, but the MIE of mixtures of more than ternary gas mixture is not examined yet. The purpose of this study is to investigate the MIE of a ternary gas(methane, ethylene, hydrogen, propane) mixtures experimentally. The results of our experiment show that the ignition of a methane-ethylene-air, methane-hydrogen-air, methane-propane-air, ethylene-hydrogen-air, ethylene-propane-air and hydrogen-propane-air mixture due to electrostatic discharge energy primarily depends on that the mixture: the MIE decreases gradually with the increase of having the lower MIE than other mixture ratio in the normal atmospheric pressure.

A Study on the MESG of Flammable Ternary Gas Mixtures (3성분계 인화성 혼합가스의 MESG에 관한 연구)

  • Hwang, Kyungyong;Byeon, Junghwan;Rhee, Kyunam;Lee, Taeck-Kie
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.3
    • /
    • pp.30-37
    • /
    • 2016
  • Electrical apparatuses for use in the presence of flammable gas atmospheres have to be specially designed to prevent them from igniting the explosive gas. Flameproof design implies that electrical components producing electrical sparks are contained in enclosures and withstand the maximum pressure of internal gas or vapours. In addition, any gaps in the enclosure wall have to designed in such a way that they will not transmit a gas explosion inside the enclosure to an explosive gas or vapours atmosphere outside it. In this study, we explained some of the most important physical mechanism of MESG(Maximum Experimental Safe Gap) that the jet of combustion products ejected through the flame gap to the external surroundings do not have an energy and temperature large enough to initiate an ignition of external gas or vapours. We measured the MESG and maximum explosion pressure of ternary gas mixtures(propane-acetylene-air) by the test method and procedure of IEC 60079-20-1:2010. As a result, the composition of propane gas that has lower explosive power than acetylene gas in the ternary gas mixtures makes greater effects on MESG and explosion pressure.

Optimum Condition for Xe Gas Excitation in Plasma Display Panels through Ternary Gas of He, Ne, Xe

  • Khorami, Alireza;Ghanbari, Shirin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.744-747
    • /
    • 2009
  • Plasma Display Panels (PDPs) have illustrated impressive results in terms of light emission efficiency of the Ne-Xe mixture compared with the He-Xe mixture. However, He-Xe has shown to achieve superior color purity. This paper presents the optimization of excitation efficiency and color purity for He-Ne-Xe ternary gas mixtures. Furthermore, we investigate the effect that a protective dielectric layer has on UV photon efficiency in a matrix known as electrode type PDP.

  • PDF

Binary and ternary gas mixtures of He-Ne-Xe for improvement of vacuum ultraviolet luminous efficiency in ac-PDPs.

  • Jung, Kyu-Bong;Lee, Jun-Ho;Park, Won-Bae;Jeon, Wook;Oh, Phil-Young;Cho, Guang-Sup;Uhm, Han-Sup;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.522-524
    • /
    • 2004
  • The improvement of luminance and luminous efficiency is the one of the most important part in AC-PDPs. To achieve high luminance and luminous efficiency, high VUV emission efficiency is needed. We measured the emission spectra of vacuum ultraviolet(VUV) rays in surface discharge AC-PDP with binary and ternary gas mixtures of Ne-Xe and He-Ne-Xe. The influence of He-Ne-Xe gas-mixture ratio on excited $Xe^{\ast}$ resonant atoms and $Xe_2$$^{\ast}$ dimers has been investigated. It is found that luminous efficiency of ternary gas mixture, He-Ne-Xe, is shown to be much higher than that of binary gas mixture of Ne-Xe.

  • PDF

Thermal Decomposition Characteristics on Sodium Azide and Metallic Oxide Mixtures (나트륨 아지드와 금속산화물과의 혼합물에 대한 열분해 특성)

  • 이내우;최재욱;박광수;설수덕;왕석주
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.3
    • /
    • pp.106-113
    • /
    • 1997
  • The thermal characteristics of two binary mixtures by sodium azide/manganese dioxide and ferric oxide, two ternary mixtures by sodium azide/silicon dioxide/manganese dioxide and ferric oxide were studied to obtain the basic data of gas-generating agents for air bags. The thermal reaction for all mixtures started at about $420^{\circ}C$, but the temperature at which the reaction rate reached a maximum was different with the states of samples. According to reaction results, nitrogen, nitrogen oxide and nitrogen dioxide were detected by GC-MS and so many kinds of new chemicals from sodium azide and metal oxide mixtures by XRD. NMS is considered as most stable and reasonable mixture for this types of gas-generating agents.

  • PDF

The characteristics of AC-PDPs According to binary and ternary gas mixtures of He-Ne-Xe_

  • Lee, H.J.;Son, C.G.;Lee, S.B.;Han, Y.K.;Jeoung, S.H.;You, N.L.;Lim, J.E.;Lee, J.H.;Moon, M.W.;Oh, P.Y.;Jeoung, J.M.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1195-1198
    • /
    • 2005
  • The improvement of efficiency is the one of the most important part in AC PDPs . To achieve high efficiency, high VUV emission efficiency and High ion induces secondary electron emission coefficient are needed. We have measured the emission spectra of vacuum ultraviolet rays and ion induced secondary electron emission coefficient of MgO protective layer in surface discharge AC-PDP with binary and ternary gas mixtures. We have investigated electro-optical characteristics of AC-PDPs to optimum gas mixture for high efficient.

  • PDF

Hydrogen Separation from Binary and Ternary Mixture Gases by Pressure Swing Adsorption (PSA 공정에 의한 이성분 및 삼성분 혼합기체로부터 수소분리)

  • Kang, Seok-Hyun;Jeong, Byung-Man;Choi, Hyun-Woo;Ahn, Eui-Sub;Jang, Seong-Cheol;Kim, Sung-Hyun;Lee, Byung-Kwon;Choi, Dae-Ki
    • Korean Chemical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.728-739
    • /
    • 2005
  • An experiment and simulation were performed for hydrogen separation of mixtures by PSA (pressure swing adsorption) process on activated carbon. The binary ($H_2/Ar$; 80%/ 20%) and ternary ($H_2/Ar/CH_4$; 60%/ 20%/ 20%) mixtures were used to study the effects of feed composition. The cyclic performances such as purity, recovery, and productivity of 2bed-6step PSA process were experimentally and theoretically compared under non-isothermal and non-adiabatic conditions. The develped process produced the hydrogen with 99% purity and 75% recovery from both processes. Therefore, optimal separation condition was referred multicomponent gas mixtures.

Forced convective boiling heat transfer for a ternary refrigerant mixture inside a horizontal tube (수평관내 3성분 혼합냉매의 강제대류비등 열전달)

  • 오종택
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.912-920
    • /
    • 1999
  • The forced convective boiling heat transfer coefficients of R-407C were measured inside a horizontal tube 6.0mm I.D. and 4.0m long. The heat transfer coefficients increased according to an increase in heat flux at constant mass flux. Because nucleation was completely suppressed in the two-phase flow region with high quality, heat transfer coefficients in forced convective evaporation were higher than those in nucleate boiling region. Average heat transfer coefficients of R-407C were about 30 percent lower than the pure refrigerant correlation, due to mass transfer resistance at the gas-liquid interface. However, the total experimental data shows an agreement with the predicted data for ternary refrigerant mixtures with a mean deviation of 30%.

  • PDF

Liquid-Liquid Phase Separation in a Quaternary System of PolysuIfone/Polyethersulfone/N-Methyl-2-pyrrolidone/water (사성분계 시스템의 액액상분리에 관한 연구 (폴리술폰/폴리에테르술폰/NMP/물))

  • 백기전;김제영;이환광;김성철
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.22-24
    • /
    • 1998
  • 1. INTRODUCTION : The phase inversion method is widely used to prepare a variety of polymeric membranes ranging from micro-filtration to gas separation. The final morphology obtained by immersion precipitation strongly reflects the thermodynamics and kinetics of the system involved. The equilibrium thermodynamics of the ternary system of polymer/solvent/ nonsolvent is still very important to understand and predict membrane structure. Polysulfone (PSf) and polyethersulfone (PES) are important polymers as membrane materials due to the chemical resistance, mechanical strength, thermal stability and transport properies. There are several reports on the experimental phase diagrams in ternary mixtures of PSf/solvent/nonsolvent, and PES/solvent/nonsolvent. It would be interesting to investigate the solution thermodynamics containing these two polymers since PES is slightly less hyclrophobic than PSf.

  • PDF

Multi-scale simulation of wall film condensation in the presence of non-condensable gases using heat structure-coupled CFD and system analysis codes

  • Lee, Chang Won;Yoo, Jin-Seong;Cho, Hyoung Kyu
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2488-2498
    • /
    • 2021
  • The wall film-wise condensation plays an important role in the heat transfer processes of heat exchangers, refrigerators, and air conditioner. In the field of nuclear engineering, steam condensation is often utilized in safety systems to remove the core decay heat under both transient and accident conditions. In particular, passive containment cooling system (PCCS), are designed to ensure containment safety under severe accident conditions. A computational fluid dynamics (CFD) scale analysis has been conducted to calculate the heat transfer rate of the PCCS. However, despite the increase in computing power, there are challenges in the long-term transient simulation of containment using CFD scale codes. In this study, a heat structure coupling between the CFD and system analysis codes was performed to efficiently analyze PCCS. In addition, the component unstructured program for interfacial dynamics (CUPID) was improved to analyze the condensation behavior of ternary gas mixtures. Thereafter, the condensation heat transfer on the primary side was calculated using the improved CUPID and CFD code, whereas that on the secondary side was simulated using MARS. Both the coupled codes were validated against the CONAN facility database. Finally, conjugate heat transfer simulations with wall condensation in the presence of non-condensable gases were appropriately performed.