• 제목/요약/키워드: tension field

검색결과 451건 처리시간 0.026초

Study on Improvement of Blood Stagnation by Pulsed Magnetic Field

  • Son, Hee Jung;Yoo, Jun Sang;Lee, Myeung Hee;Hwang, Do Gwen;Lee, Hyun Sook
    • Journal of Magnetics
    • /
    • 제20권2호
    • /
    • pp.114-119
    • /
    • 2015
  • This study explored the effect of pulsed magnetic field (PMF) stimulus on the improvement of blood stagnation by means of photoplethysmography (PPG). Our stimulus system was designed to generate PMF with a maximum intensity variation of 0.20 T at a transition time of $160{\mu}s$, with pulse intervals of 1 Hz. In order to quantitatively estimate vascular condition, indices such as blood vessel tension (BVT), stress power (SP), differential pulse wave index (DPI) and remained blood volume (RBV) were calculated from the second derivative of the PPG signal and power density spectrum (PDS). Our results showed that non-invasive PMF stimulus was effective in improving blood stagnation. Therefore, it may be concluded that appropriate PMF stimulus affects the blood circulatory system.

고장력볼트 마찰이음의 합리적 설계 및 시공에 관한 연구 (A Study on Rational Design and Construction of High-Tension-Bolt Friction Joints)

  • 이승용;경갑수
    • 대한토목학회논문집
    • /
    • 제26권3A호
    • /
    • pp.513-521
    • /
    • 2006
  • 최근에는 고장력볼트 마찰이음의 다양화에 대해서 실무적 관점에서부터 각종 실험적 연구가 실시되고 있지만, 이러한 연구 결과가 시방기준의 개정에 반영된 것은 거의 없는 실정이다. 특히 강교량에 있어서는 최근 합리화의 추진이 강하게 대두되고 있으며, 이에 따라 강교의 설계 및 시공상 가장 중요한 부분의 하나인 고장력볼트 이음부의 합리화의 필요성이 커지고 있다. 따라서 본 연구는 고장력볼트 이음부의 설계 및 시공의 합리화를 위한 방향을 제시하고, 설계기준으로의 반영을 위한 기초자료를 제시하기 위하여 고장력볼트 이음부에 관한 국내외의 설계기준을 비교, 검토하여 설계에서 가장 중요한 인자인 미끄러짐 계수, 그리고 볼트 구멍의 크기에 대한 규정을 분석하였다. 한편 과대공 및 축력감소의 영향을 평가하기 위하여 고장력볼트 연결부에 대한 미끄러짐 시험을 실시하여 미끄러짐 거동을 평가하였다. 또한 최근에 수행된 고장력볼트 마찰이음에 관한 연구결과를 토대로 접촉면의 상태에 따른 미끄러짐 계수의 차이, 과대공의 영향, 채움판의 적용, 모재 틈새간격의 영향, 방청볼트의 사용성 등을 평가하였다. 이로부터 미끄러짐 계수의 경우 국내의 시방기준에서는 접촉면의 처리상태에 따라 일률적으로 적용되고 있는데 비하여 외국의 시방기준에서는 접촉면의 처리상태에 따라 세분화하여 규정하고 있다. 따라서 국내의 시방기준에도 접촉면의 처리상태에 따라 미끄러짐 계수를 세분하여 규정하여 설계의 합리화를 추진할 필요가 있을 것으로 판단된다. 또한 외국의 시방기준에서 적용하는 정도의 과대공을 설계에 반영하면 시공의 효율성을 증대시킬 수 있을 것으로 판단된다.

고전장하에서 제조된 PVA/Gelatin 블렌드막의 구조와 팽윤거동 (Morphology and Swelling Behaviors of PVA/Gelatin Blend Membranes Prepared Under High Electric Field)

  • 허양일;윤형구
    • 폴리머
    • /
    • 제30권6호
    • /
    • pp.563-567
    • /
    • 2006
  • 생체 적합성이 우수한 gelatin(GEL)과 기계적 물성이 뛰어난 poly(vinyl alcohol)(PVA)로 이루어진 블렌드막을 $3{\sim}10kV$의 고전장하에서 용액 캐스팅 법에 의해 제조하였고, 막중에 형성되는 미세한 domain 구조의 배향에 미치는 전장의 효과를 조사하였다. 5 kV이상의 높은 전장하에서 제조된 막의 경우 SEM 사진으로부터 막중의 GEL domain이 전장인가 방향으로 배향되어 있음을 관찰하였다. 이는 제막 중 상분리된 두 상의 계면장력 감소에 기인한 Maxwell의 정전 분산 효과에 의한 것으로 해석될 수 있다. 또한, 고전장 인가시 전극 판에서 발생하는 열과 GEL domain의 연신 배향 효과에 의해 PVA/GEL 블렌드막의 결정화도가 증가하는 것을 WAXD와 팽윤거동 관찰을 통해 확인 할 수 있었다.

주기하중을 받는 골조강판벽의 실험연구 (Framed Steel Plate Wall subject to Cyclic Lateral Load)

  • 박홍근;곽재혁;전상우;김원기
    • 한국강구조학회 논문집
    • /
    • 제16권6호통권73호
    • /
    • pp.781-792
    • /
    • 2004
  • 스티프너가 없는 얇은 강판을 사용한 골조강판벽 시스템에 대한 실험연구를 실시하였다. 1경간 3층의 골조강판벽에 주기횡하중을 재하하였으며, 주요한 실험 변수는 강판의 두께, 기둥의 강도이다. 실험결과를 이용하여 강판벽의 강도, 변형능력, 에너지 소산능력을 연구하였으며, 이를 토대로 골조강판벽의 파괴메카니즘을 분석하였다. 실험결과, 얇은 강판을 사용하는 골조강판벽은, 높은 강도, 낮은 연성능력, 캔틸레버거동특성을 나타내는 일반적인 가새골조나 스티프너 보강된 강판벽과는 여러 면에서 다른 거동특성을 나타낸다. 골조강판벽에서는 강판의 조기국부좌굴과 인장응력장 작용이 발생하면서, 전 층에 고르게 항복변형이 분포된다. 이로 인하여 변형형태는 휨변형과 전단변형의 복합형태를 나타내며, 우수한 강도 및 에너지 소산능력과 연성모멘트 골조에 버금가는 변형능력을 나타내었다. 그러나 일반적인 가새골조와는 달리 보, 기둥 등의 골조부재는 강판의 인장응력장을 지지할 수 있도록 설계되어야 하며, 따라서 기둥의 강도가 작고 콤팩트 단면을 사용하지 않은 경우에는 약층현상이 발생하며 강도가 급격히 저하되었다. 얇은 강판을 사용하는 골조강판벽은 일반적인 가새골조나 스티프너 보강 강판벽과는 차별되는 우수한 변형능력을 갖고 있으므로 연성내진구조시스템으로 활용할 수 있다.

Effect of Metallic Particles on E-field Enhancement in Extra High Voltage Gas-insulated Transmission Lines

  • Rao, M. Mohana;Satyanarayana, S.;Kumar, S. Vinay;Jain, H.S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권4호
    • /
    • pp.631-636
    • /
    • 2010
  • Gas-insulated transmission lines (GITL) are valued as technological solutions in hydro-power stations due to their enormous power handling capabilities. The performance of GITL is a function of the size of metallic particles inside the gas-insulated chamber. Electrostatic field (E-field) enhancement is a common phenomenon in gas-insulated lines due to these metallic particles. In this study, the E-field enhancement factor is calculated by considering metallic particles at various locations in the gas-insulated line/bus section, such as high-tension (HT) conductor, high-voltage shields, support insulator, and inner surface of grounded enclosure. For this purpose, a two-dimensional model based on finite element (FE) method is developed. The length of the metallic particle is in the range of 1 to 10 mm while the diameter is between 1 to 3 mm. E-field enhancement is also computed for various particle configurations of the gas-insulated system, with focus on dielectric coating made of epoxy on HT conductor and inner surface of grounded enclosure.

ON TRANSVERSALLY HARMONIC MAPS OF FOLIATED RIEMANNIAN MANIFOLDS

  • Jung, Min-Joo;Jung, Seoung-Dal
    • 대한수학회지
    • /
    • 제49권5호
    • /
    • pp.977-991
    • /
    • 2012
  • Let (M,F) and (M',F') be two foliated Riemannian manifolds with M compact. If the transversal Ricci curvature of F is nonnegative and the transversal sectional curvature of F' is nonpositive, then any transversally harmonic map ${\phi}:(M,F){\rightarrow}(M^{\prime},F^{\prime})$ is transversally totally geodesic. In addition, if the transversal Ricci curvature is positive at some point, then ${\phi}$ is transversally constant.

전차선로 드로퍼 클램프 파단 원인 분석 (The Cause Analysis on Fracture of Dropper Clamp in Catenary System)

  • 김정남;권성태;강계명
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.909-914
    • /
    • 2004
  • This study investigate the cause analysis on fracture of dropper clamp in catenary system. Dropper clamp is using as a holder between messenger wire and contact wire in catenary system. To analyze the cause analysis on fracture of dropper clamp, we have conducted experiment such as tension withstand strength test, holding strength test of a new products, SEM and EDX of field fractured specimens.

  • PDF

분기이론에 의한 콘크리트의 국소화 해석 (Localization Analysis of Concrete using Bifurcation Theory)

  • 송하원;우승민;변근주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회 논문집(I)
    • /
    • pp.353-358
    • /
    • 1998
  • The strain localization is a discontinuous phenomenon that addresses the formation of jumps of the field variables across a singularity surface. It has become widely accepted that the localization may occur as the result of discontinuous bifurcation which corresponds to the loss of ellipticity of the governing differential equations for elasto-plastic continua. In this paper, condition for strain localization in concrete based on bifurcation theory is studied and localization tensor analysis algorithm is employed to determine the directions of localization of deformations in concrete. By applying a plasticity model of concrete into the algorithm, localization analysis is performed concrete under uniaxial tension, pure shear and uniaxial compression.

  • PDF