Comparison of the Fatigue Behaviors of FRP Bridge Decks and Reinforced Concrete Conventional Decks Under Extreme Environmental Conditions

  • Kwon, Soon-Chul;Piyush K. Dutta;Kim, Yun-Hae;Anido, Roberto-Lopez
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.1-10
    • /
    • 2003
  • This paper summarizes the results of the fatigue test of four composite bridge decks in extreme temperatures (-30$^{\circ}C$ and 50$^{\circ}C$ ). The work was performed as part of a research program to evaluate and install multiple FRP bridge deck systems in Dayton, Ohio. A two-span continuous concrete deck was also built on three steel girders for the benchmark tests. Simulated wheel loads were applied simultaneously at two points by two servo-controlled hydraulic actuators specially designed and fabricated to perform under extreme temperatures. Each deck was initially subjected to one million wheel load cycles at low temperature and another one million cycles at high temperature. The results presented in this paper correspond to the fatigue response of each deck for four million load cycles at low temperature and another four million cycles at high temperature. Thus, the deck was subjected to a total of ten million cycles. Quasi-static load-deflection and load-strain responses were determined at predetermined fatigue cycle levels. Except for the progressive reduction in stiffness, no significant distress was observed in any of the composite deck prototypes during ten million load cycles. The effects of extreme temperatures and accumulated load cycles on the load-deflection and load-strain response of FRP composite and FRP-concrete hybrid bridge decks are discussed based on the experimental results.

A Study on the Reduction effect of Peak Cooling Load on the Sunshade effect of BIPV System (BIPV 시스템의 차양 효과에 따른 피크 냉방부하 절감효과에 관한 연구)

  • Lee, Chung-Sik;Lee, Eung-Jik;Lee, Chul-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.14-20
    • /
    • 2008
  • As the number of buildings that use the transparent permeation materials as the outer wall is on the increase, the coming amount of the light rays is a lot, and thus the increase in the cooling load and the radiant heat of high temperature may cause the residents to discomfort. In order to reduce such influences, this paper analyzed the installation effects of the sunshade BIPV. The inner temperature of the room installed the sunshade BIPV or otherwise was measured, and compared and analyzed the effects of reducing the cooling load by the incoming light rays. The sample space of the third floor of S university installed the sunshade BIPV has two rooms on the same conditions, and for five sunny days selected in August, the researcher measured the air temperature and the temperature of the fittings with closing the windows to minimize the movement of air without operating the coolers. The maximum cooling load measured by the incoming light rays in the room where the sunshade BIPV was not installed was examined as 459.13kcal/h. It can be understood as the effect of reducing the cooling load according to the incoming rays of the room with sunshade BIPV. Even though the effect of cooling load reduction is not so great in a room, the total reduction in cooling room for the 32 rooms installed the sunshade BIPV was estimated to be 40442.27kcal/day, which will be able to bring the maximum reduction effect of 17.1kW in energy and reduce the investment cost owing to the reduction in cooling load when initially designing the building.

J-R Curve Characterization by Load Ratio Analysis and Unloading Compliance Method for SA508 C-3 steel (SA508-3재의 제하컴플라이언스법과 하중비해석을 이용한 파괴저항곡선 평가)

  • 임만배;차귀준;윤한기;안원기
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.65-75
    • /
    • 1998
  • The fracture resistance curve is one of most important and design techniques employed in nuclear pressure vessel structures. This study is to evaluate the J-R curve characteristics for the SA508C-3 by the unloading compliance method and load rato analysis. The effect of strain aging for the exponential correlation of the J-R curve in this metal are investigated at room temperature, 20$0^{\circ}C$ and 30$0^{\circ}C$. The load ratio analysis method can evaluate the J-R curve by using the simple tension load-displacement curve only without the repeat of the unloading and loading. Therefore, the analysis by the proposed load ratio method has a merit, in comparison with the unloading compliance method, which can measure the crack length without the precision measurement equipment.

  • PDF

Application of Neural Networks to Short-Term Load Forecasting Using Electrical Load Pattern (전력부하의 유형별 단기부하예측에 신경회로망의 적용)

  • Park, Hu-Sik;Mun, Gyeong-Jun;Kim, Hyeong-Su;Hwang, Ji-Hyeon;Lee, Hwa-Seok;Park, Jun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.1
    • /
    • pp.8-14
    • /
    • 1999
  • This paper presents the methods of short-term load forecasting Kohonen neural networks and back-propagation neural networks. First, historical load data is divided into 5 patterns for the each seasonal data using Kohonen neural networks and using these results, load forecasting neural network is used for next day hourly load forecasting. Next day hourly load of weekdays and weekend except holidays are forecasted. For load forecasting in summer, max-temperature and min-temperature data as well as historical hourly load date are used as inputs of load forecasting neural networks for a better forecasting accuracy. To show the possibility of the proposed method, it was tested with hourly load data of Korea Electric Power Corporation(1994-95).

  • PDF

An experimental study on the flexural performance of laminated glass

  • Huang, Xiaokun;Liu, Gang;Liu, Qiang;Bennison, Stephen J.
    • Structural Engineering and Mechanics
    • /
    • v.49 no.2
    • /
    • pp.261-271
    • /
    • 2014
  • This paper reported an experimental study on creep behaviors of PVB and Ionoplast laminated glass (LG) under load duration of 30 days. The tests were carried out in room temperature ($23^{\circ}C$). The study revealed that after sustaining loads for 30 days, the mid-span deflection of PVB LG increased by almost 102% compared with its short term deflection, while that of Ionoplast LG approximately increased by 14%; composite effects between two glass plies in PVB LG gradually reduced with time, but did not fully vanish at the 30th day; two glass plies in Ionoplast LG on the other hand was able to withstand loads as an effective composite section during the entire loading period; the creep behaviors of both LG were not finished yet at the 30th day. In addition to this, also studied was the varying of the bending stresses of PVB and Ionoplast LG under load duration of 2 hours. The tests were carried out in ambient temperatures of $30^{\circ}C$, $50^{\circ}C$ and $80^{\circ}C$ respectively. It was found that under a given load, although the bending stresses of both LG increased with increasing temperature, for PVB LG the increasing rate of the bending stress decreased with increasing temperature, while for Ionoplast LG the increasing rate of the bending stress increased with increasing temperature.

Quality Assessment of Domestic Non-automatic Weighing Instruments for International Standards (국제표준에 대비한 국내 비자동저울의 품질평가에 관한 연구)

  • Namkoong Chai-Kwan;Kong Jae Hyang
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.6
    • /
    • pp.127-134
    • /
    • 2004
  • As the result of reduction of the barrier of national economy on matters of quality assurance of weighing instruments in recently, it is considering in domestic as well as international matters. Therefore, this study is to analysis and compare with international md national measuring standards on the electric self-indicating scale, to improve the quality of electronic machine by providing a reformation plan on currently problems of domestic manufactured, and to identify to introduce in domestic criteria from international standards. I had compared KSC 1313 to OIML R 76-1 as the performance assessment items, such as metrology Properties test, static temperature test, temperature effect testing under the un-load, electronic wave disturbance test, high-tempereature and high-humidity stability test and durability test. Therefore, only one company is passed all items of the test according to the international (reference) standards, but it is possible to improve the quality in general if it should be use the load cell and electric components which is stability of temperature change in order to supplementation to the static temperature test and temperature effect testing under the un-load. It is also possible to apply in the domestic with the OIML 76-1 after correcting the design.

Electrical Properties of Thickness-Vibration-Mode Multilayer Piezoelectric Transformer using Low Temperature Sintering (Pb,Ca,Sr,)(Ti,Mn,Sb)O3 Ceramics (저온소결 (Pb,Ca,Sr,)(Ti,Mn,Sb)O3 세라믹스를 이용한 두께진동모드 적층 압전 변압기의 전기적 특성)

  • Yoo, Ju-Hyun;Yoo, Kyung-Jin;Kim, Do-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.11
    • /
    • pp.948-952
    • /
    • 2007
  • In this study, a low temperature sintering multilayer piezoelectric transformer for a DC-DC converter was manufactured using $(Pb,Ca,Sr,)(Ti,Mn,Sb)O_3$ ceramics. Its electrical properties were investigated according to the variation in frequency and load resistance. The voltage step-up ratio of the multilayer piezoelectric transformer showed a maximum value at a resonant frequency of input part and increased with an increase of load resistance. The efficiency of the multilayer piezoelectric transformer showed the highest value at a load resistance of 17 $\Omega$. The output power was increased with increasing input voltage. Temperature increase of the multilayer piezoelectric transformer was increased with the increase of output power. At the load resistance of 17 $\Omega$, the multilayer piezoelectric transformer showed the temperature rises of about $20^{\circ}C$ at the output power of 18 W, and stable driving characteristics.

Variation Characteristics of Hourly Atmospheric Temperature Throughout a Winter (동계 시각별 외기온의 변동 특성에 관한 연구)

  • Lee, Seung-Eon;Shon, Jang-Yeul
    • Solar Energy
    • /
    • v.12 no.2
    • /
    • pp.1-8
    • /
    • 1992
  • Identifying characteristics of heating and cooling systems requires estimation of thermal load of specific time interval, especially in cases that its system is operated intermittently, by using thermal storage, of in a partial load condition. Estimating the thermal load, however, needs to forecast hourly weather data variation. Hence, this paper attempts to examine characteristics of hourly ourdoor temperature variation as a preliminary research for the mathematical modeling of the hourly weather variation. Speculating characteristics of daily minimum and maximum temperature occurances, hourly outdoor temperature variation, and daily temperature differences in the increasing range ($07h{\sim}15h$) and decreasing range($15h{\sim}07h$), we were able to analyze changing patterns of daily temperature differences in each range in terms of daily solar amount, cloud ratio, and other weather data. Results from the multiple regression analysis enables us to conclude that daily differences in the increasing range are strongly affected last night temperature itself while the other range's differences are influenced by many weather data, which are solar amount, the variation of cloud, and the maximum temperature of the previous day.

  • PDF

Effect on Thermal Performance of Superheater Module under Part Load Operation in HRSG (배열회수보일러의 부분부하 운전에 따른 유동불균일이 과열기의 성능에 미치는 영향)

  • Chong, Chae-Hon;Song, Jung-Il
    • Journal of Energy Engineering
    • /
    • v.17 no.3
    • /
    • pp.161-166
    • /
    • 2008
  • The purpose of this study is to apprehend the behavior of exhaust gas flow from gas turbine during part load operation in Heat Recovery Steam Generator. As a first step of this work, internal flow characteristics according to HRSG types were examined by CFD analysis. Next step, tube temperature according to gas turbine 53% and 100% load conditions were calculated by results of CFD and those were compared with temperature data gathered from real plant. Finally, thermal performance due to part load operation was calculated to estimate the influence of heat transfer in superheater. In addition, new type of device is suggested to eliminate the uneven temperature distribution of tubes during part load operation.

A Dynamic Rating System for Power Cables (I) - Real Time CTM(Conductor Temperature Monitoring) (전력 케이블 실시간 허용전류산정 시스템에 관한 연구 (I) - 실시간 도체 온도 추정 시스템)

  • 남석현;이수길;홍진영;김정년;정성환
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.7
    • /
    • pp.414-420
    • /
    • 2003
  • The domestic needs for larger capability of power sources are increasing to cope with the expanding power load which results from the industrial developments & the progressed life style. In summer, the peak load is mainly due to the non-industrial reasons such as air-conditioners and other cooling equipments. To cover the concentrated peak load in stable, the power transmission lines should be more constructed and efficiently operated. The ampacity design of the underground cable system is generally following international standards such as IEC287, IEC60853 and JCS168 which regards the shape of 100% daily full power loads. It is not so efficient to neglect the real shapes of load curves generally below 60~70% of full load. The dynamic (real time) rating system tends to be used with the measured thermal parameters which make it possible to calculate the maximum ampacity within required periods. In this paper, the CTM(Conductor Temperature Monitoring) which is the base of dynamic rating systems for tunnel environment is proposed by a design of lumped thermal network ($\pi$-type thermal model) and distribution temperature sensor attached configuration, including the estimation results of its performances by load cycle test on 345kV single phase XLPE cable.