• Title/Summary/Keyword: temperature by height

Search Result 1,358, Processing Time 0.032 seconds

The Variation of Top Floor Indoor Thermal Environment with Roof Storage Using Model Experiment (옥상 저류조 설치에 따른 최상층 실내열환경 변화에 관한 모형 실험연구)

  • Park, Bong-Gil;Lee, Kyung-Hee;Jang, Seung-Jae
    • Journal of the Korean housing association
    • /
    • v.20 no.3
    • /
    • pp.105-112
    • /
    • 2009
  • The purpose of this study is to investigate a top floor, indoor, thermal environment by comparison between the indoor air temperature and the rooftop surface temperature, and between the indoor air temperature and the outdoor air temperature using an experimental model. The model experiment was conducted with 4 cases,: no-rainfall, 1 em-height, 10 em-height and 20em-height of rainfall on the rooftop. According to the results of the height of stored rainfall, the average air temperature difference between the indoor and outdoor air with 1, 10 and 20 em-height of rainfall on the rooftop was $4.0^{\circ}C$, rooftop $1.2^{\circ}C$ and rooftop $1.0^{\circ}C$, respectively. The upper 10 em-height of rainfall on the rooftop acted to decrease the indoor air temperature on the top floor.

Characteristic of the Nocturnal Inversion Layer observed by Tethersonde in Daegu (계류기구로 관측한 대구시 야간 안정층 특성에 관한 사례연구)

  • 김희종;윤일희;권병혁;허만천
    • Journal of Environmental Science International
    • /
    • v.11 no.3
    • /
    • pp.155-160
    • /
    • 2002
  • Using measured data at Daegu by tethersonde for the period of 1984∼1987, we have investigated the lower atmospheric boundary layer structure including relationships between inversion layer and meteorological factors(wind and temperature), and the inversion strength and inversion height. The inversion layer was defined from the vertical temperature profile and its strength was analyzed with the wind shear as well as the vertical temperature gradient. From October to January, measured inversion layer isn't destroyed, however, in June, after sun rise, it is destroyed by surface heating and mixed layer is developed from surface. According to Pasquill stability classes, the moderately stable cases dominated. It's the larger vertical temperature gradient the lower SBL height. We have introduced B(bulk turbulence scale) which indicated SBL height. It's larger B, the higher SBL height and vice versa. It was noted that the bulk turbulence scale (B) is appropriate to determine the stable boundary layer height.

Comparative study of experimental equations on measurement of fire hight on pool fire (Pool fire에서의 화염의 높이 계산에 관한 실험식의 비교연구)

  • Hwang, Woon-Gi;Kwon, Chang-Hee
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.1
    • /
    • pp.9-13
    • /
    • 2017
  • In this study, the height of the flame required to estimate the heat flow path and flame spread in pool fire has been applied by the empirical formula, but it is calculated without applying the pressure and temperature parameters of the fire room. Until now, the height of the flame applied to pool fire was $l_F=0.235Q^{2/5}-1.02D$ in the Heskestad empirical formula, but accurate temperature calculation was not possible due to the temperature and pressure which are not influenced by the flame height. Therefore, applying the temperature and pressure around it can calculate the exact flame height, which can be applied to fire investigation and fire dynamics. The structure of the flame is divided into a continuous flame, an intermittent flame, and a buoyancy flame, but it is assumed that the flame height is calculated from the visual aspect to the intermittent flame region, and the temperature of the buoyancy flame is very low. The effect of heat of vaporization on the height of flame was investigated. The results showed that flame height was different according to the pressure and temperature around the fire room.

Analysis of Electrical Properties of Ti/Pt/Au Schottky Contacts on (n)GaAs Formed by Electron Beam Deposition and RF Sputtering

  • Sehgal, B-K;Balakrishnan, V-R;R Gulati;Tewari, S-P
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.1
    • /
    • pp.1-12
    • /
    • 2003
  • This paper describes a study on the abnormal behavior of the electrical characteristics of the (n)GaAs/Ti/Pt/Au Schottky contacts prepared by the two techniques of electron beam deposition and rf sputtering and after an annealing treatment. The samples were characterized by I-V and C-V measurements carried out over the temperature range of 150 - 350 K both in the as prepared state and after a 300 C, 30 min. anneal step. The variation of ideality factor with forward bias, the variation of ideality factor and barrier height with temperature and the difference between the capacitance barrier and current barrier show the presence of a thin interfacial oxide layer along with barrier height inhomogenieties at the metal/semiconductor interface. This barrier height inhomogeneity model also explains the lower barrier height for the sputtered samples to be due to the presence of low barrier height patches produced because of high plasma energy. After the annealing step the contacts prepared by electron beam have the highest typical current barrier height of 0.85 eV and capacitance barrier height of 0.86 eV whereas those prepared by sputtering (at the highest power studied) have the lowest typical current barrier height of 0.67 eV and capacitance barrier height of 0.78 eV.

The optimal paremeter design of rapid thermal processing to improve wafer temperature uniformity on the semiconductor manufacturing (반도체 공정에서 웨이퍼의 온도균일도향상을 위한 고속열처리공정기의 최적 파라미터 설계)

  • 최성규;최진영;권욱현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1508-1511
    • /
    • 1997
  • In this paper, design parameters of Rapid Thermal Processing(RrW) to minimize the wafer tempera ture uniformity errors are proposed. 1,anip ling positions and the wafer height are important parameters for waf er temperature uniformity in R'I'P. We propose the method to seek lamp ling positions and the wafer height for optimal temperature uniformity. l'he ~~roposed method is applied to seek optimal lamp ling positions and the waf er height of 8 inch wafer. 'I'o seek the optimal lamp ling positions and the wafer height, we var\ulcorner. lamp ling 110s itions and the wafer height and then formulate the wafer temperature uniformity problem to the linear programmi ng problem. Finally, it is shown that the wafer temperature uniformity in RI'I' designed by optimal prarneters is improved to comparing with Ii'l'P designed by the other method.

  • PDF

Penetration Height of Low-temperature Ethanol Jet Injected Into a Crossflow Airstream (횡단 공기유동장으로 분사되는 저온 에탄올 제트의 침투거리)

  • Lee, Jongkwon;Koo, Jaye
    • Journal of ILASS-Korea
    • /
    • v.25 no.2
    • /
    • pp.74-80
    • /
    • 2020
  • The jet in crossflow is a spray method used in the various air-breathing engine. In order to understand the spray characteristics in various environments, many prior studies have been conducted. However, there is a lack of understanding of the low-temperature liquid spray characteristics below 273 K. With this in mind, we tried to enhance the knowledge of the low-temperature liquid spray characteristics by identifying the penetration height of low-temperature ethanol. The experiment was conducted under phase pressure, and 273 K of air and 293, 263, and 233 K of ethanol was used. Shadowgraphy was employed to measure the liquid penetration, and Otsu's method was used to analyze the penetration height. The heights tend to decrease as the temperature of the liquid jet decreases. A correlation for the penetration height in the experimental conditions was derived and presented.

Characteristics of Impinging Diesel Spray on the Heated Flat Wall in High Temperature and High Pressure Environments (고온.고압 환경에서 가열평판에 충돌하는 디젤분무의 특성)

  • Im, Gyeong-Hun;Lee, Bong-Su;Kim, Jong-Hyeon;Gu, Ja-Ye
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.627-633
    • /
    • 2001
  • Characteristics of a diesel spray impingement with the variation of ambient temperature, wall temperature and ambient pressure were investigated through shadowgraphy method by using high speed camera. The radial penetration of spray was increased with ambient temperature and wall temperature. It is resulted from the decrease of ambient gas density caused by the increase of temperature. The height of spray was also increased with ambient temperature and wall temperature, because the height of stagnate region is noticeably increased, although height of wall jet vortex is decreased. At the same ambient pressure, the area ratio of impinging spray of room temperature environment to high temperature environment was increased, as the temperature difference between room temperature and high temperature increases. And the increment of area ratio was higher at low ambient pressure than high ambient pressure.

Height Dependence of Plasma Properties in a Solar Limb Active Region Observed by Hinode/EIS

  • Lee, Kyoung-Sun;Imada, S.;Moon, Y.J.;Lee, Jin-Yi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.110.2-110.2
    • /
    • 2012
  • We investigate a cool loop and a dark lane over a limb active region on 2007 March 14 by the Hinode/EUV Imaging Spectrometer (EIS). The cool loop is clearly seen in the EIS spectral lines formed at the transition region temperature (log T = 5.8). The dark lane is characterized by an elongated faint structure in coronal spectral lines (log T = 5.8 - 6.1) and rooted on a bright point. We examine their electron densities, Doppler velocities, and non-thermal velocities as a function of distance from the limb using the spectral lines formed at different temperatures (log T = 5.4 - 6.4). The electron densities of the cool loop and the dark lane are derived from the density sensitive line pairs of Mg VII, Fe XII, and Fe XIV spectra. Under the hydrostatic equilibrium and isothermal assumption, we determine their temperatures from the density scale height. Comparing the scale height temperatures to the peak formation temperatures of the spectral lines, we note that the scale height temperature of the cool loop is consistent with a peak formation temperature of the Mg VII (log T = 5.8) and the scale height temperature of the dark lane is close to a peak formation temperature of the Fe XII and Fe XIII (log T = 6.1 - 6.2). It is interesting to note that the structures of the cool loop and the dark lane are most visible in these temperature lines. While the non-thermal velocity in the cool loop slightly decreases (less than 7 km $s^{-1}$) along the loop, that in the dark lane sharply falls off with height. The variation of non-thermal velocity with height in the cool loop and the dark lane is contrast to that in off-limb polar coronal holes which are considered as source of the fast solar wind. Such a decrease in the non-thermal velocity may be explained by wave damping near the solar surface or turbulence due to magnetic reconnection near the bright point.

  • PDF

A study on the optimal parameter design of rapid thermal processing to improve wafer temperature uniformity (8인치 웨이퍼의 온도균일도향상을 위한 고속열처리공정기의 최적 파라미터에 설게에 관한 연구)

  • 최성규;최진영;권욱현
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.10
    • /
    • pp.68-76
    • /
    • 1997
  • In this paper, design parameters of rapid thermal processing(RTP) to minimize the wafer temperature uniformity errors are proposed. Lamp ring positions and the wafer height are important parameters for wafer temperature uniformity in RTP. We propose the method to seek lamp ring positions and the wafer gheight for optimal temperature uniformity. The proposed method is applied to seek optimal lamp ring positions and the wafer feight of 8 inch wafer. To seek the optimal lamp ring positions and the wafer height, we vary lamp ring positions and the wafer height and then formulate the wafer temperature uniformity problem to the linear programming problem. Finally, it is shown that the wafer temperature uniformity in RTP designed by optimal problem. Finally, it is hsown that the wafer temperature uniformity is RTP designed by optimal parameters is improved to comparing with RTP designed by the other method.

  • PDF

Experimental Study on the Characteristics of Combustion in Middle Size-direct Moxibustion (중주(中炷) 직접구(直接灸)의 연소특성에 관한 실험적 연구)

  • Choi, Youn-Sung;Kim, Do-Ho;Lee, Geon-Hui;Lee, Geon-Mok
    • Journal of Acupuncture Research
    • /
    • v.26 no.1
    • /
    • pp.111-119
    • /
    • 2009
  • Objectives : The purpose of this study is to investigate the mechanism and effect of moxa bucket moxibustion, to be used as the quantitative data through the measurement of temperature, and to grasp the thermodynamic characteristics of moxa bucket moxibustion. Methods : We have selected the moxa bucket moxibustion. We have made a comparative study of the thermodynamic characteristics of moxa bucket moxibustion. We have examined combustion times, temperatures, temperature gradients in each period during a combustion of moxa bucket moxibustion made by oak wood. Results : 1. We could design the moxa bucket moxibustion so that it has $57.6^{\circ}C$ maximum temperature with 7g weight and 10mm height, if we use more weight of moxa or lower height of moxa, we can observe relatively elevated maximum temperature. We observed the maximum temperature following the measuring position of moxa bucket and we could see higher temperature at the center of the moxa bucket and lower temperature at the side of the moxa bucket. 2. We could design the moxa bucket moxibustion with 5g moxa and 10mm height so that it has 0.12 $1^{\circ}C/sec$ of maximum temperature gradient, and it has relatively high temperature gradient at lower weight and height condition. 3. We could design the moxa bucket moxibustion with 7g moxa and 15mm height so that it has 4,135sec of the longest effective temperature combustion time. If we use more weight of moxa or higher height of moxa, we can observe relatively extended effective temperature combustion time. Conclusions : We observed the longest effective combustion time following the measuring position of moxa bucket. We can see a higher temperature at the center of the moxa bucket and a lower temperature at the side of the moxa bucket.

  • PDF