• Title/Summary/Keyword: temperature Compensation

Search Result 575, Processing Time 0.032 seconds

The Error Analysis of Leak Measurement for Pneumatic Cylinder Using Isothermal Chamber

  • Jang, Ji-Seong;Ji, Sang-Won;Kagawa, Toshiharu
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.1
    • /
    • pp.6-12
    • /
    • 2008
  • ISO pneumatic cylinder reliability test requires air leakage measurement. Air cylinder has many parts and the leakage shall be measured before, during and after endurance test, and, the leakage should smaller than the specified value. The existing measurement method needs complex operation and the calibration of leak detector, and, has to separate the testing cylinder from endurance test device, which causes the change of contact condition of seal in the cylinder. Therefore, it is hard to evaluate the air leakage during endurance test, and guarantee the reliability of the conventional measurement method. In this paper, a new method for air leakage measurement using isothermal chamber, which does not requires calibration or temperature compensation, and, can measure air leakage accurately with quite simple operations, is proposed. As a result, reliability of air leakage measurement can be improved because the proposed method does not have to separate the testing cylinder from the endurance test device for air leakage measurement. The effectiveness of the proposed method is proved by error analysis of leak measurement from experimental result.

  • PDF

Design of a new adaptive circuit to compensate for aging effects of nanometer digital circuits (나노미터 디지털회로의 노화효과를 보상하기위한 새로운 적응형 회로 설계)

  • Kim, Kyung Ki
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.6
    • /
    • pp.25-30
    • /
    • 2013
  • In nanoscale MOSFET technology, aging effects such as Negative Bias Temperature Instability(NBTI), Hot carrier Injection(HCI), Time Dependent Dielectric Breakdown (TDDB) and so on which affect circuit reliability can lead to severe degradation of digital circuit performance. Therefore, this paper has proposed the adaptive compensation circuit to overcome the aging effects of digital circuits. The proposed circuit deploys a power gating structure with variable power switch width and variable forward body-biasing voltage in order to adaptively compensate for aging induced performance degradation, and has been designed in 45nm technology.

Rotor Time Costant Compensation for Vector-Controlled IM with DC Current Injection Method (직류전류 주입법에 의한 벡터제어 유도전동기의 회전자 시정수 보상)

  • Lee, K.J.;Nam, H.T.;Choi, J.W.;Kim, H.G.;Lee, D.K.;Chun, T.W.;Nho, E.C.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.285-287
    • /
    • 2001
  • To obtain a high performance in a vector controlled induction machine, it is essential to know the instantaneous position of the rotor flux which depends on the rotor time constant. But the rotor time constant mainly varies due to the temperature rise in the motor winding, so real time compensating algorithm is necessary. This paper proposes that it uses short duration pulses added to the constant flux command current and then resultant torque command current produced by speed controller is utilized for the rotor resistance estimation. This method has advantages with a low computational requirement and does not require voltage sensors. The proposed method is proved by simulations.

  • PDF

Color Correction in Portable-type Urine Analyzer

  • Kim, Jae-Hyung;Park, Chang-Hee;Lee, Seung-Jin;Jeon, Gye-Rok;Kim, Gi-Ryon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.4
    • /
    • pp.21-26
    • /
    • 2002
  • Color correction methods of chromaticity coordinates using Color Matching Function (CMF) were studied to develop a device-independent portable-type urine analyzer. The reflection spectra were measured for the degrees of 10 test items of the urine reagent strip (urine strip) to develop a portable-type urine analyzer. A computer simulation was performed to quantitatively distinguish the color reactions of the urine system, by using the spectral power distribution of Light Emitting Diode(LED), the reflection of a urine strip, and spectral sensitivity of a photodiode. To develop a device-independent system, chromaticity coordinates were modified to reduce the color deviations in the urine strip, by using the temperature compensation of LED and the color transformation by CMF. The experimental values obtained by developed urine system exhibited the accuracy above 95% for all color samples.

Molecular Orientation and Optical Properties of Liquid Crystal Mixture Films of Photo-Reactive Mesogens and Non-Reactive Nematic Liquid Crystals (광경화성 액정과 비반응성 네마틱 액정 혼합 필름의 분자 배향 및 광학 특성)

  • Lee, Mong-Ryong;Shin, Mi-Young;Kim, Sung-Hyun;Song, Ki-Gook
    • Polymer(Korea)
    • /
    • v.35 no.5
    • /
    • pp.493-498
    • /
    • 2011
  • Reactive mesogens were used to prepare photo-cured liquid crystal films in which orientations of liquid crystal molecules were preserved by crosslinked networks of cured reactive mesogens. The molecular orientations of liquid crystal mixtures of photo-reative mesogens and non-reactive nematic liquid crystals were studied and compared before and after curing reactions. The effects of temperature and the amount of the non-reactive nematic liquid crystal in the mixture on birefringence of the liquid crystal films were investigated. It was found that optical compensation films with different birefringence could be prepared by controlling the amount of the nematic liquid crystals in the reactive mesogen mixtures.

Development of W-band Transceiver Module using Manufactured MMIC (국내개발 MMIC칩을 적용한 W-Band 송수신모듈 개발)

  • Kim, Wan-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.233-237
    • /
    • 2017
  • The dual-channel receiver MMIC which is composed of LNA, Mixer, LO-amp and temperature compensation circuit is designed on a single chip. For the performance comparison, a FMCW radar transceiver module using commercial MMICs is also implemented. As a result, Multi-channel Transceiver using manufactured MMIC shows an improved performance such as noise figure and gain flatness compare to purchased MMIC.

The Micro Pirani Gauge with Low Noise CDS-CTIA for In-Situ Vacuum Monitoring

  • Kim, Gyungtae;Seok, Changho;Kim, Taehyun;Park, Jae Hong;Kim, Heeyeoun;Ko, Hyoungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.6
    • /
    • pp.733-740
    • /
    • 2014
  • A resistive micro Pirani gauge using amorphous silicon (a-Si) thin membrane is proposed. The proposed Pirani gauge can be easily integrated with the other process-compatible membrane-type sensors, and can be applicable for in-situ vacuum monitoring inside the vacuum package without an additional process. The vacuum level is measured by the resistance changes of the membrane using the low noise correlated double sampling (CDS) capacitive trans-impedance amplifier (CTIA). The measured vacuum range of the Pirani gauge is 0.1 to 10 Torr. The sensitivity and non-linearity are measured to be 78 mV / Torr and 0.5% in the pressure range of 0.1 to 10 Torr. The output noise level is measured to be $268{\mu}V_{rms}$ in 0.5 Hz to 50 Hz, which is 41.2% smaller than conventional CTIA.

Seasonal Changes of Chlorophyll Contents and Photosynthetic Rates in Four Species of Maple Trees in Korea (단풍나무속 식물 4 종에 대한 엽록소함량과 광합성율의 계절적 변화)

  • Choe, Hyun-sup;Hye-Jeong Lee
    • The Korean Journal of Ecology
    • /
    • v.18 no.1
    • /
    • pp.137-146
    • /
    • 1995
  • Acer pseudo-sieboldianum, A. ginnala, A. negundo and A. saccharinum were selected as materials for the studies on the seasonal fluctuation of chlorophyll content and photosynthetic rates. In all the four species during the growing season except in October, the principal component that determined the total chlorophyll content was chlorophyll a. Content of chlorophyll b increased with leaf age, but that of chlorophyll a decreased. In contrast to A. saccharinum and A. pseudo-sieboldianum which showed their maximum chlorophyll content in June, A. negundo, which showed the highest chlorophyll content of the four species, exhibited its maximum chlorophyll content in July, whereas September in the case of A. ginnala. The fluctuation of chlorophyll content was similar to that of air temperature, and it increased till July. But chloprophyll content showed a significant relationship in early stage of leaf development, and there could be any interdependence between them in accordance with the seasonal change, no longer. In all four species light compensation points decreased in accordance with the seasonal change, and the maximum photosynthetic rates were obtained in August. Respiratory rates were shown no significant difference among species, and they decreased according to the adbance of season.

  • PDF

On Climatic Characteristics in the East Asian Seas by satellite data(NOAA, Topex/Poseidon) (위성자료(NOAA, Topex/Poseidon)를 이용한 한반도 주변해역의 기후적 특성 연구)

  • 윤홍주;김상우;이문옥;박일흠
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.290-294
    • /
    • 2001
  • Satellite data, with Sea Surface Temperature(SST) by NOAA and Sea Level(SL) by Topex/poseidon, are used to estimate characteristics on the variations and correlations of SST and SL in the East Asian Seas from January 1993 through May 1998. In the oceanic climate, the variations of SL shown the high values in the main current of Kuroshio and the variations of SST shown not the remarkable seasonal variations because of the continuos compensation of warm current by Kuroshio. In the continental climate, SL shown high variations in the estuaries(the Yellow River, the Yangtze River) with the mixing the fresh water in the mouth of estuaries of the saline water in the coasts of continent and SST shown highly the seasonal variations due to the climatic effect of continents. In the steric variations in summer, the eastern sea of Japan, the East China Sea and the western sea of Korea shown the increment of sea level with 10~20cm. But the Bohai bay in China shown relatively the high values of 20~30cm due to the continental climate. Generally the trends of SST and SL increased during all periods. That is say, the slopes of SST and SL presented 0.29$^{\circ}C$/year and 0.84cm/year, respectively. The annual and semi-annual amplitudes shown a remarkable variations in the western sea of Korea and the eastern sea of Japan.

  • PDF

Performance Improvement of CO Sensor Signal Conditioner for Early Fire Detection System (조기화재 감시시스템을 위한 CO센서의 시그널컨디셔너 성능개선)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.2
    • /
    • pp.82-87
    • /
    • 2017
  • This paper presents performance improvement of CO gas sensor signal conditioner for early fire warning system. The warning system is based on the CO sensor and its advanced signal conditioning modules network that employ electochemical gas sensor. The electochemical has advantage of having a linear output and operating with a low consumption and fast response. This electrochemical gas sensor contains a gas membrane and three electrodes(working, counter, reference electrode) in contact with an electrolyte. To use a three-electrode sensor, a voltage has to be applied between the working and the reference electrode according to the specification of the sensor. In this paper, we designed these requirements that should be considered in temperature compensation algorithm and electrode measurement of CO sensor modules by using advanced signal conditioning method included 3-electrode. Simulation and experimental results show that signal conditioner of CO sensor module using 3-electrode have a advantage linearity, sensitivity and stability, fast response etc..