• Title/Summary/Keyword: tapes wires

Search Result 43, Processing Time 0.023 seconds

Transport current Losses of the HTS Stacked Tapes at Various Gap between Tapes (고온초전도 적층선재에서의 층간 거리에 따른 전송전류 손실)

  • 임형우;이승욱;이희준;차귀수;이지광
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.254-256
    • /
    • 2003
  • AC loss is one of the important superconducting power machine that we have to consider deeply using the stack wires with the HTS. AC magnetic field is occurred around the wires when the electric current is conducted to the stack wires. It also brings electric field to the wires and occurs self field loss, whose quantity is appeared differently by distance of the stack wires. In this paper, transport current losses of a stack short sample of HTS were compared with Norris equation and measured value.

  • PDF

Fabrication and evaluation of superconducting properties of HIS PIT long tapes (고온초전도 PIT 장선재 제조 및 특성 평가)

  • Ha, Hong-Soo;Lee, Dong-Hoon;Yang, Joo-Saeng;Hwang, Sun-Yuk;Choi, Jung-Kyu;Kim, Sang-Chul;Ha, Dong-Woo;Oh, Sang-Soo;Kwon, Young-Kil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.597-600
    • /
    • 2003
  • Bi-2223/Ag HTS wires have been fabricated by the PIT(powder in tube)process. Intermediate annealing was carried out to increase the homogenization and uniformity of the superconducting filaments embedded in the silver matrix during the deformation process that is important to sustain the engineering critical current density in long superconducting wire. Intermediate annealing act to release the deformation hardening of the superconducting wires during drawing process. Rolling parameters were investigated to roll the superconducting tapes with uniform thickness, width and winding tensions. Critical current of 60 m long superconducting tapes was measured 54.3 A continuously after final sintering heat treatment. The phase analysis of Bi-2223/Ag superconducting tapes are examined by the XRD.

  • PDF

Characteristics of the HTS Stacked Tapes and AC Losses of the Multi-Stacked Pancake Coil (고온초전도 적층선재의 특성과 적층선재로 제작한 팬케이크 권선 손실)

  • Lee Seungwook;Lim Hyoungwoo;Cha Gueesoo;Lee Jikwang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.11
    • /
    • pp.658-663
    • /
    • 2004
  • According to the improvement of the HTS wires performance, several tapes of HTS superconducting machines are being developed. Stacked HTS tapes are used as conductor that can flow high current for the HTS power machines. To develop the HTS power machines, the critical current characteristics of a stacked HTS tapes in external filed and AC losses should be examined. In this paper, we present characteristic of the stacked HTS tapes and AC losses of HTS pancake windings with stacked tapes. AC loss of the pancake winding were measured and compared with the calculated loss by using AC loss data of the stacked samples and the magnetic flux density in the HTS winding under operating conditions. We can see that measured results generally agree well with the calculated results by using AC loss data of 4-stacked sample.

Effects of the External Magnetic field on the Critical Current and AC Loss of HTS Stacked Tapes

  • Lee, Seungwook;Hyoungwoo Lim;Park, Myeongseob;Lee, Heejoon;Gueesoo Cha;Lee, Jikwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.87-91
    • /
    • 2003
  • According to the improvement of the HTS wires performance, several types of HTS superconducting machines are being developed. Stacked HTS tapes are used to conduct the current of the HTS power machines. To develop the HTS power machines, the critical current characteristics of a stacked HTS tapes in external field need be examined. In this paper, we present effect of the external magnetic field on the critical current of HTS stacked tapes. The critical current of various Hinds of multi-stacked HTS tapes in external magnetic filed are compare with that of a single HTS tape. Test results show that critical current of single HTS tape is smaller than that of multi-stacked HTS tape in the external field.

The effect of heat treatment mass flow on superconducting property of Bi-2223/Ag Tapes. (열처리 가스유량에 따른 Bi-2223/Ag 초전도 테이프의 특성에 미치는 영향)

  • 양주생;하동우;이동훈;최정규;황선역;오상수;김상철;김명호
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.96-98
    • /
    • 2003
  • Many of research efforts have been focused on the improvement of critical current density Jc of silver-sheathed Bi-2223 tapes for practical applications of material. Bi-2223 superconducting wires with 55 filaments were fabricated by stacking, drawing process with different heat-treatment histories. After rolling process, Bi-2223 tapes were heat-treatment at 780~826$^{\circ}C$ with variable mass flow rate of mixed gas. In this study, the effect of changes in the variable mass flow rate of mixed gas during the heat treatment of Bi-2223/Ag tapes has been investigated. Distinct differences were observed in the Bi-2223 phase and critical current as flow rate of mixed gas. We could achieve proper conditions of mass flow rate of mixed gas for Ag-alloy clad Bi-2223 superconducting tapes.

  • PDF

ANALYSIS OF ADHESIVE TAPE ACTIVATION DURING REACTOR FLUX MEASUREMENTS

  • Bignell, Lindsey Jordan;Smith, Michael Leslie;Alexiev, Dimitri;Hashemi-Nezhad, Seyed Reza
    • Nuclear Engineering and Technology
    • /
    • v.40 no.1
    • /
    • pp.93-98
    • /
    • 2008
  • Several adhesive tapes have been studied in terms of their suitability for securing gold wires into positions for neutron flux measurements in the reactor core and irradiation facilities surrounding the core of the Open Pool Australian Light water (OPAL) reactor. Gamma ray spectrometry has been performed on each irradiated tape in order to identify and quantify activated components. Numerous metallic impurities have been identified in all tapes. Calculations relating to both the effective neutron shielding properties of the tapes and the error in measurement of the $^{198}Au$ activity caused by superfluous activity due to residual tape have been made. The most important identified effects were the prolonged cooling times required before safe enough levels of radioactivity to allow handling were reached, and extra activity caused by residual tape when measured with an ionisation chamber. Knowledge of the most suitable tape can allow a minimal contribution due to these effects, and the use of gamma spectrometry in preference to ionisation chamber measurements of the flux wires is shown to make all systematic errors due to the tape completely negligible.

Effect of pre-annealing conditions on mechanical and superconducting properties of Bi-2223/Ag tapes (초전도 선재의 전 열처리에 따른 기계적 및 초전도 특성에 미치는 효과)

  • 양주생;하동우;이동훈;최정규;황선역;하홍수;오상수;권영길;김명호
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.124-127
    • /
    • 2004
  • Many of research efforts have been focused on the improvement of critical current density (Jc) of silver-sheathed Bi-2223 tapes far practical applications. In this study, the transformation of Bi-2212 phase was investigated, which was transformed to orthorhombic from tetragonal through pre-annealing during powder packing and drawing process. The relationship between hardness of Bi-2212 orthorhombic phase and workability of Bi-2223/Ag tape was investigated. Bi-2223 superconducting wires with 55 filaments were fabricated by stacking and drawing process with different heat-treatment histories. Before rolling process, round wires were pre-annealing at 76$0^{\circ}C$ and in a low oxygen partial pressure. We confirmed that pre-annealing step was to transform to Bi-2212 orthorhombic structure from Bi-2212 tetragonal structure and to reduce the formation of second phases. However the breakages were created at Ag-alloy clad during rolling for pre-annealed Bi-22231Ag tapes. Several pre-annealing scenarios were introduced to reduce the breakages during rolling process. Microstructure and critical current density of pre-annealed Bi-2223 superconducting tapes were investigated. We could achieve proper pre-annealing conditions for Ag-alloy clad Bi-2223 superconducting tapes.

  • PDF

Superconducting properties of Bi-2223 tapes with various pre-annealing conditions (전열처리 조건에 따른 Bi-2223 초전도 선재에서의 특성 변화)

  • 하동우;하홍수;오상수;이동훈;윤진국;양주생;최정규;권영길
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.176-179
    • /
    • 2003
  • A lot of efforts have been focused on the optimization of PIT parameters for Bi-2223/Ag wire. Bi-2223 superconducting wires with 55 filaments were fabricated by stacking, drawing process. Before rolling process, round wires were pre -annealed at 760 - 820 $^{\circ}C$ and low oxygen partial pressure. We confirmed that pre-annealing step was to transform Bi-2212 orthorhombic structure from Bi-2212 tetragonal structure and to reduce the formation of second phases. However Bi-2223 phases also were formed at higher than 76$0^{\circ}C$ of pre-annealing temperature. The engineering critical current densities (Je) of Bi-22231Ag tapes were sintered at low oxygen partial pressure were higher than t hat of the wires sintered at air. We could achieve 6500 A/${cm}^2$ of Je for the tape that was initially kept at slightly higher temperature than that of normal heat treatment.

  • PDF

Optimization of wire construction from several 2G HTS tapes

  • Kumarov, D.R.;Sotnikov, D.;Scherbakov, V.I.;Mankevich, A.;Molodyk, A.;Sim, Kideok;Hwang, Soon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.4
    • /
    • pp.24-28
    • /
    • 2019
  • Despite the second generation HTS tapes (2G HTS tape) have limits in critical current value, scientific and electric devices require more current density day after day. These requirements are realized by using different superconducting wires that consist of 2G HTS tapes designed in various combinations. Authors of this paper have developed the numerical model for estimation of total critical current in the superconducting wire and critical current in each 2G HTS tape placed in this superconducting wire. The current drop in six 2G HTS tapes having different constructions was analyzed. The result of this research is the decrease of critical current up to 25 % for the stack of tapes and up to 5 % for the parallel tapes in the same plane. In addition, what was also made is the estimation of the current distribution by length for six 25 m 2G HTS tapes in different constructions and determination of current deviation by length of the wire.