• Title/Summary/Keyword: tap water supply

Search Result 94, Processing Time 0.026 seconds

A Waterborne Outbreak and Detection of Cryptosporidium Oocysts in Drinking Water of an Older High-Rise Apartment Complex in Seoul

  • Cho, Eun-Joo;Yang, Jin-Young;Lee, Eun-Sook;Kim, Se-Chul;Cha, So-Yang;Kim, Sung-Tek;Lee, Man-Ho;Han, Sun-Hee;Park, Young-Sang
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.4
    • /
    • pp.461-466
    • /
    • 2013
  • From May to June 2012, a waterborne outbreak of 124 cases of cryptosporidiosis occurred in the plumbing system of an older high-rise apartment complex in Seoul, Republic of Korea. The residents of this apartment complex had symptoms of watery diarrhea and vomiting. Tap water samples in the apartment complex and its adjacent buildings were collected and tested for 57 parameters under the Korean Drinking Water Standards and for additional 11 microbiological parameters. The microbiological parameters included total colony counts, Clostridium perfringens, Enterococcus, fecal streptococcus, Salmonella, Shigella, Pseudomonas aeruginosa, Cryptosporidium oocysts, Giardia cysts, total culturable virus, and Norovirus. While the tap water samples of the adjacent buildings complied with the Korean Drinking Water Standards for all parameters, fecal bacteria and Cryptosporidium oocysts were detected in the tap water samples of the outbreak apartment complex. It turned out that the agent of the disease was Cryptosporidium parvum. The drinking water was polluted with sewage from a septic tank in the apartment complex. To remove C. parvum oocysts, we conducted physical processes of cleaning the water storage tanks, flushing the indoor pipes, and replacing old pipes with new ones. Finally we restored the clean drinking water to the apartment complex after identification of no oocysts.

Development of an Optimal Operation Model of Residual Chlorine Concentration in Water Supply System (송·배수시스템의 최적 잔류염소농도 관리 모델 개발)

  • Kim, Kibum;Hyung, Jinseok;Seo, Jeewon;Shin, Hwisu;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.587-597
    • /
    • 2017
  • This study aimed to develop a method to optimize residual chlorine concentrations in the process of providing water supply. To this end, this study developed a model capable of optimizing the chlorine input into the clearwell in the purification plant and the optimal installation location of rechlorination facilities, and chlorine input. This study applied genetic algorithms finding the optimal point with appropriate residual chlorine concentrations and deriving a cost-optimal solution. The developed model was applied to SN purification plant supply area. As a result, it was possible to meet the target residual chlorine concentration with the minimum cost. Also, the optimal operation method in target area according to the water temperature and volume of supply was suggested. On the basis of the results, this study derived the most economical operational method of coping with water pollution in the process of providing water supply and satisfying the service level required by consumers in the aspects of cost effectiveness. It is considered possible to appropriately respond to increasing service level required by consumers in the future and to use the study results to establish an operational management plan in a short-term perspective.

Construction of Tap Water Management System for Subset Area of Hamyang Gun Using GIS (GIS를 이용한 함양군 일부지역의 상수도 관리 시스템 구축)

  • 김재명;안기원;신석효;김상철
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.347-352
    • /
    • 2003
  • This study attempts to develop the management and control system of water pipe on the footing of database builded by the research on the pipe of water supply equipped over 48.809km within district of Hamyang-up by Hamyang-Gun, and to apply it to the work of self-governing body. And, since the structure and equipment of facilities of underground water supply pipe ate so complex, the maintenance and management of function of facilities are needed for long-term. This study has the purpose to build the database per self-governing body which can be connected with the future NGIS project, and to promote the efficiency of management and control of facilities and equipment.

  • PDF

Assessment of Variable Characteristics in Water Quality of the Supply Systems in the Building (건축물내 급수설비의 수질변화 특성과 영향력 평가)

  • Lee, H.D.;Hwang, J.W.;Bae, C.H.;Kim, S.J.
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.313-320
    • /
    • 2004
  • In this study, variable characteristics of drinking water and the influences on underground water reservoirs, rooftop water tanks, and service water pipes in the building were assessed. The influence of underground water reservoir material and water capacity on water quality also were assessed. The results are the following as; First of all, the drinking water passing through underground water reservoirs or service water pipes in the building, averagely metal component concentration more increased from percent of 41.3 to percent of 74.2 totally than other items of water quality. On the other hand, both residual chlorine and total solid highly decreased 65.6 percent and 35.3 percent, respectively. Therefore, it was thought that water quality could be getting worse for microorganism re-growth by residual chlorine reduction, and total solid also could be a cause for extraneous matters accumulated in water reservoir. Secondly, the variations on water quality of each stage for water supply system in the building were higher in water service pipes connected from rooftop water tanks to the tap than in underground water reservoirs. In addition to, among of twelve items on water quality, ten items on water quality except dissolved oxygen and residual chlorine increased. Therefore, it was thought that the influence of water service pipes connected from rooftop water tanks to the tap on water quality were higher than other stages of water supply system in the building. Thirdly, in case of materials of underground water reservoir, it was likely that the variation on water quality by stainless steel and concrete materials got some similar. In case of water capacity, the variations on water quality of underground water reservoirs over $1,000m^3$ higher than those under $1,000m^3$. That reasons was likely that the retention time(49.72 hours averagely) of underground water reservoirs over $1,000m^3$ was two times longer than it of those under $1,000m^3$(23.37 hours). Therefore, it was thought that the influence on water quality by materials were some similar, but in case of water capacity, the influence of underground water reservoirs were higher.

Benefit of the Drinking Water Supply System in Office Building by Rainwater Harvesting: A Demo Project in Hanoi, Vietnam

  • Dao, Anh-Dzung;Nguyen, Viet-Anh;Han, Mooyoung
    • Environmental Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.103-108
    • /
    • 2013
  • Vietnam is a developing country with the rate around 5%-6% per year, especially in urban areas. Rapidly developed urban areas lead to stress for infrastructure and the water supply is also stressed. In Hanoi city, total water capacity from the manufactories is around one million cubic meters per day and almost the entire main water source is groundwater but it is not enough to supply all of Hanoi's people, especially in the summer. A demo project is implemented in Hanoi University of Civil Engineering (HUCE) to produce drinking water by using the rainwater and membrane system and supply for people. In this project, rainwater is collected on the rooftop of the lecture building with an area of around $500m^2$ and $100m^3$ volumetric rainwater tanks. Afterwards, the rainwater is treated by the micro-membrane system and supplied to the tap water. Total cost for construction, technology and operation in the first year is around USD 48,558. In the long-term (15 yr) if HUCE invests in the same system, with $20m^3$ volumetric storage tank, it can provide drinking water for 500 staffs in every year. The cost of investment and operation for this system is lower than 30% compared to buying bottled water with the price USD 1.8/bottle. The drinking water parameters after treatment are pH, 7.3-7.75; turbidity, 0.6-0.8 NUT; total dissolved solids, 60-89 mg/L; coliform, 0; heavy metal similar with water quality in the bottle water in Vietnam.

A Study on THMs Formation in Service Waters and Waste Waters at Kunsan (군산지역 용 . 폐수중의 THMs생성 및 배출에 관한 연구)

  • 황갑수;이영남;김강주;여성구;김진삼
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.41-46
    • /
    • 2001
  • Trihalomethane(THMs) levels in drinking tap water, indoor swimming pool water and industrial effluent in Kunsan area were surveyed in this study. During experimental period, the monthly averages of THMs in drinking tap water from Keumkang wide-area supply ranged from 15$\mu\textrm{g}$/ι/to 50 $\mu\textrm{g}$ showing the highest level in summer. 3 indoor swimming pools showed the monthly average levels of THMs formation ranging from 8$\mu\textrm{g}$/ι/to 20$\mu\textrm{g}$/ι and the pool under public management seemed to maintain its water quality more stable than those under private management THMs concentrations in the effluents. discharged from 10 manufacturing companies, ranged from N.D. to 95$\mu\textrm{g}$/ι and it was estimated that the overall THMs level discharged front those manufacturing companies is not high, reflecting the traces recorded for most effluents. The composition ratios of individual THMs for industrial effluents showed a difference from those for drinking water and swimming pool water, along with their wide variations according to the company and relatively high composition ratios of Br substituents.

  • PDF

Distribution of Hot Tap Water Load for District Heating Substation with Hot Tap Water 2-Stage Heat Exchanger (급탕 2단열교환방식 지역난방 열사용시설의 급탕부하 분배에 관한 연구)

  • Jeong, Dong-Hwa;Kim, Joo-Wan;Baik, Young-Jin;Lee, Young-Soo;Chung, Dae-Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.297-302
    • /
    • 2011
  • According to the standards for district heating substation established by Korea District Heating Corporation, water heating supply systems at over 150 Mcal/h capacity must employ the 2-stage heat exchanger that improves the system efficiency by reusing the heat included in the return water of district heating system already used for space heating. In this paper, the operating characteristics of the system in accordance with the load distribution of two heat exchangers for pre-heating and re-heating cold city water are investigated. The results including mass flow rate, return temperature etc. help to manage district heating system economically.

Epidemiologic Investigation on an Outbreak of Salmonellosis in Yeongcheon-si, 2004 (2004년 영천시 D 초등학교에서 집단 발생한 살모넬라증)

  • Min, Young-Sun;Lee, Hwan-Seok;Lim, Hyun-Sul
    • Journal of Preventive Medicine and Public Health
    • /
    • v.38 no.4
    • /
    • pp.457-464
    • /
    • 2005
  • Objectives : An outbreak of salmonellosis occurred among the student s and staff of D primary school in Yeongcheon-si, 2004. This investigation was carried out to prevent any recurrence of this outbreak and to study the infection source and transmission of the salmonellosis. Methods : The authors conducted a questionnaire survey among 1,205 students and staff members from D primary school about the ingestion of the school lunch and drinking water, and the manifestation of their symptoms. The author examined rectal swabs, the tap water and microorganism cultures, and we also investigated the dining facility and water supply facility. Results : The diarrheal cases were defined as the confirmed cases or the persons who had diarrhea more than one time with symptoms such as fever, vomiting and tenesmus. The diarrheal attack rate was 28.0%. Ingestion of fried bean curd with egg had a significantly high association with the diarrheal attack rate (p<0.05), and the relative risk of the fried bean curd with egg was 10.68 (95% CI=3.88-29.41), as was determined by logistic regression analysis. The bacterial counts in the tap water of the food preparation room and toilet (first floor) exceeded the maximum permissible counts. S. Enteritidis bacteria were only cultured from the fried bean curd with egg of all the supplied foods on September 3, 2004. Conclusions : The major cause of salmonellosis was presumed to be the contaminated bean curd via contaminated tap water due to a water leak of a school water pipe. This contaminated bean curd was under prepared, which allowed the S. Enteritidis to survive and multiply prior to its ingestion.

Study on $NH_4H_2PO_4$ in nutrient solution using tap water for water supply during hydroponic raising of crisp lettuce (수돗물을 용수로 사용한 결구상추의 수경육묘시 배양액내 $NH_4H_2PO_4$에 관한 연구)

  • 김주희;김혜진;김영식
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1995.04a
    • /
    • pp.75-78
    • /
    • 1995
  • 양액재배시 배양액의 pH는 중요한 재배인자이며, 이는 용수의 성질에 따라 큰 영향을 받는다. 용수로는 지하수를 많이 사용하나, 수돗물을 사용하는 경우도 흔히 있다. 수돗물은 pH가 7.5 정도로, pH가 낮은 용수를 사용할 경우와 같은 조성의 배양액을 조제하면 배양액의 pH가 높아 생육에 나쁜 영향을 끼친다. 따라서, 용수의 성질에 따라 배양액의 조성을 달리하여 pH를 적정수준으로 유지하는 것이 중요하다. (중략)

  • PDF

An Examination Performed to Identify the Causative Agent of Crusian Carp (Carassius carassius) Mass Mortality in Jinyangho

  • Shin, Gee-Wook;Lee, Hu-Jang;Jung, Tae-Sung
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.4
    • /
    • pp.1-3
    • /
    • 2003
  • Jinyangho is a natural water supply source of tap water in west Gyeongnam area, but mass mortality of crusian carp occurred during the time of temperature rise in spring. Examinations on diseased fishes were able to isolate four bacteria isolates and then identified the bacteria as a member of Aeromonas sp. Challenge experiment with mirror carp (Gyrinus carpiospecilaris) was proved the virulence, the isolates were in turn believed as the causative agent of mass mortality in Jinyangho.