Analysis of Insulation Diagnosis and Failure in Stator Windings of Air-Cooled Gas Turbine Generator

  • Kim, Hee-Dong;Kong, Tae-Sik;Kim, Kyeong-Yeol
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.421-424
    • /
    • 2016
  • In order to evaluate the insulation deterioration in the stator windings of air-cooled gas turbine generators(119.2 MVA, 13.8 kV) which has been operating for more than 15 years, diagnostic test and AC dielectric breakdown test were performed on phases A, B and C. Diagnostic test included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B, and C) of generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable condition. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. Although phase A of generator stator windings failed at breakdown voltage of 29.0 kV, phases B and C endured the 29.0 kV. The breakdown voltage in all three phases was higher than that expected for good-quality windings (28.6 kV) in a 13.8 kV class generator.

고압회전기기 고정자권선의 Off-line 진단을 통한 신뢰성 평가 (Reliability Assessment of High Voltage Rotating Machine Stator Windings Through Off-line Diagnosis)

  • 장정호;임재일;이동근;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1628-1629
    • /
    • 2011
  • 산업현장에서는 회전기기의 고체절연시스템(solid insulation system)의 열화정도를 평가하기 위하여 일정 진단주기에 맞춰 Off-line 상태에서 직류시험 및 교류시험을 통하여 효과적으로 절연물에 대한 상태평가를 시행하고 있다. 직류시험으로는 절연저항, 성극지수(PI) 시험 등이 있으며 교류시험으로는 교류전류시험(${\Delta}I$), 유전정접시험(${\Delta}tan{\delta}$), 부분방전(PD)시험이 있다. 여기서 부분방전은 절연체의 국부적인 열화현상을 추정할 수 있는 중요한 파라미터로, 부분방전시험(PD test)을 통하여 고정자권선(stator winding)에 대한 절연특성을 효과적으로 진단할 수 있다. 고압 전동기는 기동정지의 빈번함과 장기간 운전에 의해 열적, 전기적, 기계적 스트레스를 받게 되고, 이로 인해 과열, 진동, 절연파괴에 이르는 문제점이 발생되어 결국 시스템의 운전정지를 초래하는 심각한 사고로 이어질 수 있다. 따라서 고압 전동기의 절연상태를 주기적으로 감시하고 사고 징후를 검출하여 시스템을 안정적으로 운영하기 위한 고압 전동기 Off-line 절연진단에 대하여 기술하고 수차발전기에 대한 절연상태진단 결과를 바탕으로 절연시스템의 신뢰성 평가 방법에 대하여 고찰하고자 한다.

  • PDF

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

Determinants of Income Diversification among Rural Households in the Mekong River Delta: The Economic Transition Period

  • LE, Long Hau;LE, Tan Nghiem
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제7권5호
    • /
    • pp.291-304
    • /
    • 2020
  • This paper examines the factors that drive temporal income diversification in rural areas of the Mekong River Delta in Vietnam, based on a framework that conceptualized diversification as a function of a household's capacity to diversify and incentives (both push and pull factors) to diversify. Drawing from five rounds of the Vietnam Living Standard Measurement Surveys covering a 13-year span (1993-2006), two panel datasets made from five cross-sectional samples are used for the analyses. The data are drawn from the Vietnam General Statistics Office. Both tobit model and Ordinary Least Squares model with random and fixed effects are applied. The main points emerging from the analysis is that income diversification is strongly influenced by household labor capacity. The relationship between household labor capacity and increasing insertion in non-farming wage activities is not driven by unobserved time-invariant factors such as household ability and motivation, but is instead driven by the higher labor capacity of households. In terms of the other household capacity variables, the effect of farm size is much larger in terms of retaining households in traditional occupations as compared to pushing them towards non-farm wage employment. Other variables such as household access to financial capital do not play an important role.

SBR/Organoclay Nanocomposites for the Application on Tire Tread Compounds

  • Kim, Wook-Soo;Lee, Dong-Hyun;Kim, Il-Jin;Son, Min-Jin;Kim, Won-Ho;Cho, Seong-Gyu
    • Macromolecular Research
    • /
    • 제17권10호
    • /
    • pp.776-784
    • /
    • 2009
  • N,N-dimethyldodecylamine (tertiary amine)-modified MMT (DDA-MMT) was prepared as an organically modified layered silicate (OLS), after which styrene-butadiene rubber (SBR) nanocomposites reinforced with the OLS were manufactured via the latex method. The layer distance of the OLS and the morphology of the nanocomposites were characterized by X-ray diffraction (XRD) and transmission electron microscopy (TEM). By increasing the amount of N,N-dimethyldodecylamine (DDA) up to 2.5 g, the maximum values of torque, tensile strength and wear resistance of the SBR nanocomposites were increased due to the increased dispersion of the silicate layers in the rubber matrix and the increased crosslinking of the SBR nanocomposites by DDA itself. When SBR nanocomposites were manufactured by using the ternary filler system (carbon black/silica/OLS) to improve their dynamic properties as a tire tread compound, the tan $\delta$(at $0^{\circ}C$ and $60^{\circ}C$) property of the compounds was improved by using metal stearates instead of stearic acid. The mechanical properties and wear resistance were increased by direct substitution of calcium stearate for stearic acid because the filler-rubber interaction was increased by the strong ionic effect between the calcium cation and silicates with anionic surface. However, as the amount of calcium stearate was further increased above 0.5 phr, the mechanical properties and wear resistance were degraded due to the lubrication effect of the excessive amount of calcium stearate. Consequently, the SBR/organoclay nanocomposites that used carbon black, silica, and organoclay as their ternary filler system showed excellent dynamic properties, mechanical properties and wear resistance as a tire tread compound for passenger cars when 0.5 phr of calcium stearate was substituted for the conventionally used stearic acid.

IR-UWB 시스템 응용을 위한 시간- 및 주파수-영역에서의 앤티포달 비발디 안테나 성능 평가 (Performance Evaluation of Antipodal Vivaldi Antenna in the Time- and Frequency-Domains for IR-UWB Systems Application)

  • 고영목;김근용;나극환
    • 한국전자파학회논문지
    • /
    • 제23권2호
    • /
    • pp.159-168
    • /
    • 2012
  • 본 논문에서는 IR-UWB(Impulse Radio Ultra Wideband) 시스템 응용을 위한 앤티포달 비발디 안테나를 설계하고, 시간 및 주파수 영역에서 나노 초 단위의 초광대역 임펄스 신호 전송을 위한 IR-UWB 안테나 성능 평가를 수행하였다. 설계된 앤티포달 비발디 안테나는 저가 생산이 가능한 두께 1.6 mm, 유전율 ${\epsilon}_r=4.7$, $tan{\delta}=0.002$인 FR-4 기판을 이용하여 제작하였다. 제작된 안테나는 무반사실에서 주파수 영역 파라메타인 반사 손실, Far 필드방사 패턴을 측정하였다. 또한, 시간 영역에서 나노 초 단위의 임펄스 신호 전송에 따른 펄스 충실도 분석을 수행하여 UWB 대역에서 안정적으로 초광대역 신호 전송이 가능함을 증명하였다. 본 논문에서 설계/제작된 앤티포달 비발디 안테나는 낮은 왜곡과 양호한 방사 특성을 갖고, 나노 초 단위의 초광대역 임펄스를 방사 또는 수신할 수 있다.

발전소에서 운전 중인 활성 6.6kV 전력 케이블의 고장상태를 파악하는 장치의 개발 (Developing Equipment to Detect the Deterioration Status of 6.6kV Power Cables in Operation at Power Station)

  • 엄기홍;이관우
    • 한국인터넷방송통신학회논문지
    • /
    • 제14권4호
    • /
    • pp.197-203
    • /
    • 2014
  • 발전소의 전력 케이블 시스템에서 발생할 수 있는 사고를 예측하고 방지하는 기술이 필요하다. 사선 상태에 있는 케이블의 동작 특성을 진단하기 위하여 부분방전 및 $tan{\delta}$ 법이 사용되고 있으나, 케이블이 갖고 있는 문제점들을 사전에 발견하기란 쉬운 일이 아니다. 이 논문에서 우리가 연구한 케이블은 (주)서부 발전소에서 설치되어 운전 중인, 발전 운영에 핵심 역할을 하는 6.6kV 고전압 배전 선로이다. 케이블의 온도 및 전류를 측정하고, 이를 바탕으로 절연저항을 측정하기 위한 장치를 개발하였다. 이 장치를 발전소 현장에 시험 설치를 하였고, 동작 중인 케이블의 수명을 평가하기 위한 동작특성의 진단을 성공적으로 마무리 하였다. 진단 데이터를 분석 평가함으로써 단기적으로는 운전 중 6.6kV 케이블 시스템의 고장상태를 파악하는데 활용되며, 장기적으로는 발전소 부하에서의 6.6kV 케이블 시스템의 설치 및 운영에 있어서 원가를 절감하기 위한 노력에 기여하고자 한다.

부착면 표면물질에 의한 성능 왜곡을 최소화한 이중 선로의 비대칭 다이폴 형태 태그 안테나 설계 (Design of a Tag Antenna with a Low Performance Distortion from an Attached Surface Material Using the Asymmetric Dual-Arm Dipole Structure)

  • 김도균;추호성
    • 한국전자파학회논문지
    • /
    • 제18권4호
    • /
    • pp.398-407
    • /
    • 2007
  • 본 논문에서는 부착될 물질이 가지는 전기적 특성에 의한 성능 변화가 적은 이중 선로의 비대칭 다이폴 형태 RFID 용도 태그 안테나(Asymmetric Dual-arm Dipole Antenna: ADDA)를 제안하였다. 제안된 태그 안테나는 상용 의료 폐기물 수거용 플라스틱 밀폐 용기(${\varepsilon}_r=1.7,\;tan\;{\delta}=0.002$)에 부착하여도 안테나의 동작 특성 변화가 적도록 설계되었다. 안테나의 세부적인 설계변수는 자유공간과 인식 대상 물체에 부착시 우수한 인식거리 성능을 나타내도록 Pareto 유전자 알고리즘을 사용하여 최적화하였다. 최적화 태그 안테나는 $100\;mm{\times}50\;mm$의 크기를 가지며, 3.7 %의 반사 손실 대역폭($S_{11}$< -10 dB)을 가지고 80 %의 복사효율을 나타내었다. 인식 거리 측정 결과, 자유공간에서 정면 방향(broadside) 5.3 m, 의료 폐기물 수거용 플라스틱 밀폐 용기에 부착시 최대 5.5 m의 인식거리 성능을 가지는 것을 확인하였다.

황 및 가황 촉진제의 함량에 따른 NR/BR 블렌드의 가황과 물리적·기계적 특성의 변화 (The Changes of Vulcanization and Physico-Mechanical Properties of NR/BR Blend with the Content of Sulfur and Accelerator)

  • 김완영;이대수;김윤섭;김형순;라창운
    • 공업화학
    • /
    • 제2권4호
    • /
    • pp.356-362
    • /
    • 1991
  • 가황계에 따른 NR/BR 블렌드의 물리적 기계적 특성의 변화를 가교밀도의 차이로 해석하였다. 경화제의 비율 및 함량이 증가함에 따라 가황속도 및 최대 토오크는 증가를 보였으며, 가교밀도도 증가하였다. 가교밀도의 증가에 따라 경도, 300% 모듈러스, 반발탄성 및 마모특성은 증가를 보인 반면에 발열에 의한 온도 상승 및 $60^{\circ}C$에서의 tan $\delta$는 감소를 보였다. 따라서 높은 하중이 가해지는 트럭/버스 타이어의 트레드 부위에 사용하는 경우 회전저항이 적은 semi-EV 가황계가 가장 적절한 가황 시스템으로 판단되었다.

  • PDF

Aging 과정 중 하드록시프로필화 쌀전분의 동적 레올로지 특성 (Dynamic Rheological Properties of Hydroxypropylated Rice Starches during the Aging Process)

  • 최혜미;유병승
    • 한국식품과학회지
    • /
    • 제39권5호
    • /
    • pp.584-587
    • /
    • 2007
  • 치환도를 달리한 하이드록시프로필화 쌀전분의 동적 레올로지 특성이 소변형 진동측정방법(small-deformation oscillatory measurement)에 의해 관찰되었다. Aging 전 $4^{\circ}C$에서 측정된 저장탄성률 G#과 손실탄성률 G"의 값은 치환도(0.030-0.118)가 증가함에 따라 증가하였으며, 반면에 tan ${\delta}5(G"/G#)$는 감소하였다 $4^{\circ}C$에서 10시간 aging하는 동안 하이드록시프로필화 쌀전분의 G#값은 초기 단계에서 급속히 증가한 다음 곧 바로 2시간이내에 안정기(plateau) 영역에 도달하였다. 그러나 천연전분(native starch)은 10시간 동안의 aging후에도 안정기 영역이 관측되지 않았다. 치환도의 증가는 하이드록시프로필화 쌀전분의 안정기 G#값의 감소를 초래하였다. Aging하는 동안의 구조전개 속도상수 K는 1차 kinetics식으로부터 얻어졌으며, 하이드록시프로필화 쌀전분의 K값은 높은 치환도에서 낮은 수치를 보여주었다.