• 제목/요약/키워드: tMRI

검색결과 1,247건 처리시간 0.024초

The Ongoing Effect of Transcranial Direct Current Stimulation on both the Hemispheres: Single Case fMRI Study

  • Kwon, Jung-Won;Son, Sung-Min;Kim, Chung-Sun;Cho, In-Sul
    • The Journal of Korean Physical Therapy
    • /
    • 제23권6호
    • /
    • pp.49-53
    • /
    • 2011
  • Purpose: The purpose of this study is to investigate whether dual-hemisphere transcranial direct current stimulation (tDCS) could induce more cortical activity, compared to single-hemisphere, using functional MRI (fMRI). Methods: One right-handed healthy subject was recruited. Three phases of dual-hemisphere tDCS (i.e. anodal tDCS over the left-dominant primary sensoriomotor cortex (SM1) and cathodal tDCS over the right-non dominant SM(1) were consecutively delivered on to a subject, during fMRI scanning. The voxel count and the intensity index in the averaged cortical map were analyzed among the three tDCS phases. Results: Our result showed that cortical activation was observed on all the three phases of the dual-hemisphere tDCS. Voxel count and intensity index were as following; 912 and 4.07 in the first phase, 1102 and 3.90 in the second phase, 1031 and 3.80 in the third phase. Conclusion: This study demonstrated that application of the dual-hemisphere tDCS could induce cortical activity and maintain to recruit cortical neurons. Our findings suggested that application of dual-hemisphere tDCS could produce efficiency of the ongoing tDCS effect to facilitate cortical excitability.

황색육아종성 담낭염과 벽비후형 담낭암의 감별진단을 위한 자기공명영상 점수체계의 유용성 (Usefulness of MRI Scoring System for Differential Diagnosis between Xanthogranulomatous Cholecystitis and Wall-Thickening Type Gallbladder Cancer)

  • 한솔;이영환;김유리;소은규
    • 대한영상의학회지
    • /
    • 제85권1호
    • /
    • pp.147-160
    • /
    • 2024
  • 목적 황색육아종성 담낭염을 벽비후형 담낭암으로부터 감별진단하기 위한 자기공명영상(MRI) 점수체계를 고안하고, 그 점수체계의 진단능을 영상의학과 의사의 시각적 평가와 비교하고자 한다. 대상과 방법 복부 MRI 및 수술을 시행한 각각 황색육아종성 담낭염과 벽비후형 담낭암으로 진단된 23명과 35명의 환자를 후향적으로 분석하였다. 세 명의 영상의학과 의사가 모든 MRI 소견을 분석하였다. 저자들은 이러한 MRI 소견을 이용하여 벽비후형 담낭암으로부터 황색육아종성 담낭염을 감별진단하기 위한 점수체계를 고안하였고 이 점수체계의 진단능을 수신자 운영 특성 곡선의 곡선 하 면적을 영상의학과 의사의 시각적 평가와 비교하였다. 결과 9가지의 MRI 소견이 두 질환의 감별에 유의미한 차이를 보였다: 미만형 벽 비후(p < 0.001), 점막 균일성(p = 0.002), 벽내 T2 고신호강호(p < 0.001), 점막 당김(p = 0.016), 담낭 결석(p < 0.001), T1 중등도 혹은 고신호강도(p = 0.033), 확산 제한(p = 0.005), 조영증강 패턴(p < 0.001), 조영증강 최고점 시기(p = 0.008). MRI 점수체계는 곡선 하 면적이 0.972로 뛰어난 진단능을 나타내었고 이는 영상의학과 의사의 시각적 평가보다 유의미하게 높았다. 결론 MRI 점수체계는 황색육아종성 담낭염을 벽비후형 담낭암으로부터 감별진단하는 데 있어 영상의학과 의사의 시각적 평가보다 좋은 진단능을 나타내었다.

자장 세기와 스캔 방향이 다른 자기공명영상에서 측정된 해마 체적의 재현성 연구 (A study on the reproducibility of hippocampal volumes measured using magnetic resonance images of different magnetic field strengths and slice orientations)

  • 최유용;이동희;이상웅;이건호;권구락
    • 스마트미디어저널
    • /
    • 제5권1호
    • /
    • pp.44-48
    • /
    • 2016
  • 장기추적 뇌영상 연구에서 자기공명영상장치의 노후 또는 기술 발전에 따른 업그레이드로 인해 연구기간 내 동일한 촬영 조건을 유지하기 어렵다. 특히, 자장 세기가 1.5T에서 3T로 증가한 경우가 많아, 기존 1.5T 영상을 새로운 3T 영상과 통합해서 분석에 사용하는 것이 가능한지 확인할 필요가 있다. 본 논문에서는 자장 세기와 스캔 방향이 다른 자기공명영상에서 측정한 해마 체적의 재현성을 연구 분석하였다. 실험참가자 296명의 3차원 T1 영상을 1.5와 3T 자기공명영상장치 각각에서 스캔 방향을 달리하여 획득하고 뇌영상 연구에 널리 사용되는 Freesurfer를 이용하여 실험참가자의 해마 체적을 측정하였다. 해마 체적의 영상종류 간 차이를 확인하기 위해 대응표본t-검정을 수행한 결과, 자기공명영상장치의 자장 세기와 스캔 방향에 따라 해마체적이 유의하게 차이가 있음을 확인하였다. 이런 결과는 촬영조건에 따라 측정된 해마체적이 달라질 수 있음을 의미하므로, 촬영 조건이 다른 영상을 통합 분석할 수 있는 기법의 개발이 필요하다고 판단된다.

뇌 기능영상에서의 TE값의 변화에 따른 1.5T와 3.0T MRI의 자화율 변화 비교 (The Comparison of Susceptibility Changes in 1.5T and3.0T MRIs due to TE Change in Functional MRI)

  • 김태;최보영;김의녕;서태석;이흥규;신경섭
    • Investigative Magnetic Resonance Imaging
    • /
    • 제3권2호
    • /
    • pp.154-158
    • /
    • 1999
  • 목적 : 1.5T와 3.0T에서의 FLASH (fast low-angle shot) 기법를 이용한 운동중추영역의 뇌기능 자기공명영상에서 TE 값 변화에 대한 $T_2^{*}$ weighting 효과를 관찰하고 TE 값의 변화에 따른 BOLD (blood oxygen level dependent) 효과를 서로 비교하고자 한다. 그리고 활성화 영역에서 활성화상태와 휴식상태의 정량적인 값인 $T_2^{*}$에 의한 차이값을 영상화 하고자 한다. 대상 및 방법 : 24세에서 35세까지의 오른손잡이 10명의 건강한 남녀 (남:8명, 여:2명)를 대상으로 가능한 2Hz의 속도로 오른손에서 finger-tapping task (엄지 손가락과 나머지 네 손가락을 차례로 서로 마주치게 하는 운동)를 시행하였다. 운동자극은 처음에 한벤의 휴식상태 (3영상)를 가진 후2번의 활성화상태 (6영상)와 휴식상태 (6영상)를 반복하였다. FLASH (TR/flip angle: $l00ms/20^{\circ}$, FOV: 230mm) 방법를 이용하여1.5T'에서는 26, 36, 46, 56, 66 ms 의 TE를 사용하였고 3.0T에서는 16. 26, 36, 46, 56 ms의 TE를 사용하였다. 영승L을 얻은 후 PC에서 상관계수방법을 이용하여 자체 개발한 프로그램과 상관계수 0.45를 사용하여 분석 하였다. 기능적 영상에서 활성화된 영역에서 l.5T와 3.0T에서 각각의 TE에셔 활성화 상태와 휴식상태 의 차이값을 사용하여 fitting을 하여 적절한 TE값을 찾고 기능적 $T_2^{*}$영상을 구하였다. 결과 : FLASH기법을 사용하여 뇌 기능영상을 얻기에 최적의 TE 값은 1.5T에서는 $61.89{\pm}2 2.68{\;}ms,{\;}3.0T에서는{\;}47.64{\pm}13.34였다$. 뇌 활성화 영역에서 자화율 변화에 따른최대 선호 강도변화는 1.5T에서는 TE, 66ms에서 3.36%. 3.0T에서는 TE. 46ms에서 10.05%로 3.0T가 1.5T에 비해 약 3배 정도 변화가 큰 것을 알 수 있었다. 산출된 최적의 TE 값은 각각의 TE 값에서 얻은 활성화 상태와 휴식상태의 차이값의 최대의 TE 값와 일치하였다. 결론 : 뇌 기능영상에서 3.0T MRl는 1.5T에 비해 deoxyhemoglobin에 의한 자화율의 변화를 약 3배정도 잘 반영하므로 뇌 기능영상 측정시 보다 유용성이 있는 것으로 사료된다.

  • PDF

비 인두 자기공명 검사 시 최적의 진단영상 장치 선택에 관한 정량, 정성적 평가에 관한 연구 (A Study of the Quantitative, Qualitative Analysis on Optimizing Diagnostic Imaging Device Selection in Nasopharynx MRI)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.1035-1043
    • /
    • 2019
  • 본 연구의 목적은 1.5 T와 3.0 T 비 인두 MRI 검사 후 SNR과 CNR을 평가하여 최적의 Tesla를 알아보고자 하였다. 총 30명의 PACS로 전송된 Nasopharynx MRI검사 환자를 무작위로 선택하여 본 연구에 적용하였다. 데이터 분석에 사용된 장비로는 1.5 T, 3.0 T MRI 장비를 이용하였다. 분석 방법으로 T1 WI과 T1 지방소거 영상에서 각 Tongue, Spinal Cord, Masseter Muscle, Fat, Parotid Gland, Tumor의 조직에 대하여 일정한 관심영역을 설정하고 SNR와 CNR을 평가하였다. 6가지의 조직에 대하여 정량적 분석으로 SNR과 CNR을 평가하였고, 정성적 분석으로 균일한 지방소거, 자화 감수성 인공물에 대한 영상의 질을 4점 척도로 측정하였다. 본 데이터 분석의 통계적 유의성은 독립표본 T검증과 Wilcoxon Signed Ranks사용하였으며, p 값이 0.05이하일 때 유의성을 두었다. 본 실험에 대한 정량적 평가 결과 T1 WI 과 T1 지방소거를 1.5 T와 3.0 T를 비교했을 때 T1 WI에 대한 3.0 T가 평균 SNR(124.75±), CNR(118.91±)로 정량적 분석에서 SNR과 CNR값이 1.5 T평균 SNR(73.15±), CNR(60.59±)에 비해 높게 나타났다. 또한 T1 지방소거에서 3.0 T가 평균 SNR(101.10±), CNR(81.24±)로 1.5 T의 평균 SNR(78.47±), CNR(65.70±)에 비해 높게 나타났다. 정성적 분석으로 균일한 지방소거, 자화 감수성 인공물에 대하여 4등급으로 평가했을 때 1.5 T 장비가 높은 점수를 얻었다(p<0.05). 결론적으로 두 기기에 대한 데이터 분석 결과 정량적 평가부분 에서는 3.0 T 장비가 높게 나타났고 정성적 평가 부분에서는 1.5 T가 높게 나타났다. 따라서 각 장비에 대한 장단점을 고려할 때 상호보완적으로 장비를 선택하여 환자에게 적용한다면 최적의 정보를 제공할 것이라고 사료된다.

저자장 자기공명영상 시스템 내에서 초상자성 나노입자 온열치료를 위한 발열 평가 (Feasibility Study on Magnetic Nanoparticle Hyperthermia in Low Field MRI)

  • 김기수;조민형;이수열
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권4호
    • /
    • pp.105-110
    • /
    • 2014
  • For the combination of MRI and magnetic particle hyperthermia(MPH), we investigated the relative heating efficiency with respect to the strength of the static magnetic field under which the magnetic nanoparticles are to be heated by RF magnetic field. We performed nanoparticle heating experiments at the fringe field of 3T MRI magnet with applying the RF magnetic field perpendicularly to the static magnetic field. The static field strengths were 0T, 0.1T, 0.2T, and 0.3T. To prevent the coil heat from conducting to the nanoparticle suspension, we cooled the heating solenoid coil with temperature-controlled water with applying heat insulators between the solenoid coil and the nanoparticle container. We observed significant decrease of heat generation, up to 6% at 0.3T(100% at 0T), due to the magnetic saturation of the nanoparticles of 15 nm diameter under the static field. We think MPH is still feasible at low magnetic field lower than 0.3T if stronger RF magnetic field generation is permitted.

Early Bone Marrow Edema Pattern of the Osteoporotic Vertebral Compression Fracture : Can Be Predictor of Vertebral Deformity Types and Prognosis?

  • Ahn, Sung Eun;Ryu, Kyung Nam;Park, Ji Seon;Jin, Wook;Park, So Young;Kim, Sung Bum
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권2호
    • /
    • pp.137-142
    • /
    • 2016
  • Objective : To evaluate whether an early bone marrow edema pattern predicts vertebral deformity types and prognosis in osteoporotic vertebral compression fracture (OVCF). Methods : This retrospective study enrolled 64 patients with 75 acute OVCFs who underwent early MRI and followed up MRI. On early MRI, the low SI pattern of OVCF on T1WI were assessed and classified into 3 types (diffuse, globular or patchy, band-like). On followed up MRI, the vertebral deformity types (anterior wedge, biconcave, crush), degree of vertebral body height loss, incidence of vertebral osteonecrosis and spinal stenosis were assessed for each vertebral fracture types. Results : According to the early bone marrow edema pattern on T1WI, 26 vertebrae were type 1, 14 vertebrae were type 2 and 35 vertebrae were type 3. On followed up MRI, the crush-type vertebral deformity was most frequent among the type 1 OVCFs, the biconcave-type vertebral deformity was most frequent among the type 2 OVCFs and the anterior wedge-type vertebral deformity was most frequent among the type 3 OVCFs (p<0.001). In addition, type 1 early bone marrow edema pattern of OVCF on T1WI were associated with higher incidence of severe degree vertebral body height loss, vertebral osteonecrosis and spinal stenosis on the follow up MRI. Conclusion : Early bone marrow edema pattern of OVCF on T1WI, significant correlated with vertebral deformity types on the follow up MRI. The severe degree of vertebral height loss, vertebral osteonecrosis, and spinal stenosis were more frequent in patients with diffuse low SI pattern.

7T MRI에서 B1 필드 조정을 위해 페로브스카이트 재료를 이용한 자기공명영상 향상 (MRI Enhancement using Perovskite Material for B1 Field Control at 7T)

  • 김용태;김주연;백현만
    • 한국방사선학회논문지
    • /
    • 제15권4호
    • /
    • pp.565-573
    • /
    • 2021
  • 인체 내 전자기장의 공간 분포는 고 유전율 재료를 사용하여 비교적 간단하게 조정할 수 있다. 이 방법은 다른 방법에 비해 보완적인 성격이 강하지만 특정 응용 분야에서 강력한 유전체 시밍용 도구로 활용될 수 있다. 기하학적으로 자유로운 형상으로 제조 가능하며 시스템의 어떠한 변경 없이 목적에 따라 제작된 패드를 적용할 수 있다. 특히 초 고자장(ultrahigh magnetic field UHF) MRI에서 높은 작동 주파수로 인해 낮은 감도 (low sensitivity)를 갖는 송신 (B1+) 및 수신 (B1-) 필드의 강도를 높이는 데 사용되는 임상목적의 고 유전율 패드는 잠재적 가치가 상당히 클 뿐만 아니라 그 효과가 클 것으로 예상되는 UHF MRI에 적용된 연구가 적기 때문에 이 연구에서는 티탄산 칼슘의 현탁액으로 제조된 고 유전율 패드를 실험실에서 직접 개발하였으며 UHF 7T 자기공명영상 MRI의 다양한 프로토콜에서 임상적으로 유용한 영상의 신호증가를 확인하였다.

Compressed Sensing 기법을 이용한 Dynamic MR Imaging (Compressed Sensing Based Dynamic MR Imaging: A Short Survey)

  • 정홍;예종철
    • 대한전자공학회논문지SP
    • /
    • 제46권5호
    • /
    • pp.25-31
    • /
    • 2009
  • Compressed sensing은 기존의 Nyquist sampling 이론에 기반을 두었던 dynamic MRI에서의 시 공간 해상도의 제한을 획기적으로 향상시킴으로써, 최근 몇 년 사이, MR reconstruction 분야에서 가장 큰 이슈가 되고 있는 연구주제이다. Dynamic MRI 는 대부분 시간방향의 redundancy 가 매우 크므로, 쉽게 sparse 변환이 가능하다. 따라서 sparsity를 기본 조건으로 하는 compressed sensing은 거의 모든 dynamic MRI 에 대해 효과적으로 적용될 수 있다. 본 review 페이퍼에서는 최근 compressed sensing 에 기반을 두거나 영상의 sparsity를 이용하여 개발된 dynamic MR imaging algorithm 들을 간략히 소개하고, 비교 분석함으로써, compressed sensing과 같은 새로운 접근 방식의 dynamic MRI가 실제 임상에서 가져다 줄 발전 가능성을 제시한다.

MRI 소음의 특성을 이용한 공동 내부 목표점의 능동소음 제어 (Active Noise Control for Target Point Inside Bore Using Property of MRI Noise)

  • 이록행;박영진;박윤식
    • 한국소음진동공학회논문집
    • /
    • 제24권1호
    • /
    • pp.62-68
    • /
    • 2014
  • Recently, MRI(magnetic resonance imager) scanner is continually used for medical diagnosis and many biomedical researches. When it operates, however, intense noise is generated. The SPL(sound pressure level) of the noise approaches 130 dB especially in 3 T(Tesla) MRI. Meanwhile, more than 3 T MRI scanners have been developed to get higher-resolution images, so louder noise is expected in the future. The intense noise makes patients feel nervous and uncomfortable. Moreover, it could possibly cause hearing loss to patient in extreme cases. For this reason, some active noise control systems have been researched. One of them used feedback Filtered-X LMS(FXLMS) algorithm which is able to control only narrowband noises and possible to diverge in severe case. In this paper, we determine the property of MRI noise. Using the property, we applied a method of open-loop and adaptive control for reducing MRI noise at target point inside bore. We verified performance of the method with computer simulation and preliminary experiment. The results demonstrate that the method can effectively reduce MRI noise at target point.