• 제목/요약/키워드: tMRI

검색결과 1,250건 처리시간 0.023초

Development of a Brain Phantom for Multimodal Image Registration in Radiotherapy Treatment Planning

  • H. S. Jin;T. S. Suh;R. H. Juh;J. Y. Song;C. B. Y. Choe;Lee, H .G.;C. Kwark
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.450-453
    • /
    • 2002
  • In radiotherapy treatment planning, it is critical to deliver the radiation dose to tumor and protect surrounding normal tissue. Recent developments in functional imaging and radiotherapy treatment technology have been raising chances to control tumor saving normal tissues. A brain phantom which could be used for image registration technique of CT-MR and CT-SPECT images using surface matching was developed. The brain phantom was specially designed to obtain imaging dataset of CT, MR, and SPECT. The phantom had an external frame with 4 N-shaped pipes filled with acryl rods, Pb rods for CT, MR, and SPECT imaging, respectively. 8 acrylic pipes were inserted into the empty space of the brain phantom to be imaged for geometric evaluation of the matching. For an optimization algorithm of image registration, we used Downhill simplex algorithm suggested as a fast surface matching algorithm. Accuracy of image fusion was assessed by the comparison between the center points of the section of N-shaped bars in the external frame and the inserted pipes of the phantom and minimized cost functions of the optimization algorithm. Technique with partially transparent, mixed images using color on gray was used for visual assessment of the image registration process. The errors of image registration of CT-MR and CT-SPECT were within 2mm and 4mm, respectively. Since these errors were considered within a reasonable margin from the phantom study, the phantom is expected to be used for conventional image registration between multimodal image datasets..

  • PDF

병원의 설립형태 및 수익성과 비급여 서비스 가격의 연관성 (Relationship of Hospital Ownership and Profitability with Prices of Non-Covered Services)

  • 김도희;김태현
    • 한국병원경영학회지
    • /
    • 제28권1호
    • /
    • pp.37-51
    • /
    • 2023
  • Purposes: There exist many non-covered services that the National Health Insurance does not cover, and thus, their prices are set by individual health care providers. However, little study has been done to investigate how hospitals set prices for those services. The purpose of this study is to examine the relationship between ownership, profitability, and prices of those services for a sample of general hospitals. Methodology/Approach: Data regarding the prices of major non-covered services (e.g., upper-level hospital room fees, MRI, Da 7inci robot surgery, and LASIK) were obtained from the Health Insurance Review and Assessment Service and the financial information, as well as other characteristics, were derived from the financial reports from the Korea Health Industry Development Institute. Descriptive statistics, t-tests, and multiple linear regression analyses were used to test the relationship between the independent variables and the dependent variables. Findings: Hospitals owned by private universities appeared to have higher prices for non-covered services while regional public hospitals tend to have lower prices. Profitability, measured by operating margin, was not significantly related to the prices. Hospitals that charge higher prices were more likely to be located in the capital area (Seoul, Incheon, and Gyeonggi), and to employ larger number of personnel. Practical Implications: Public hospitals tend to charge lower prices for non-covered services. Relative market power appears to be related to pricing. Further research is needed to investigate whether such a relationship varies over time and its effects on the quality and access.

  • PDF

가스분무로 제조된 NdFeB 합금분말의 강소성변형을 통한 결정립 미세화 및 이방성 제어 (Control of Grain Refinement and Anisotropy of NdFeB Alloy Powder by Severe Plastic Deformation Fabricated by the Gas Atomization Process)

  • 조주영;박상민;자비드 후세인;송명석;김택수
    • 소성∙가공
    • /
    • 제31권3호
    • /
    • pp.124-128
    • /
    • 2022
  • NdFeB magnets have been positioned as the core materials in advanced technologies such as MRI (magnetic resonance imaging), FA (factory automation system), robot, motors, and so on based on the highest magnetic properties. To effectively improve the refined microstructure, the plastic deformation has been known as the good alternatives by the recrystallization. However, it has been regarded as being impossible because of the few slip systems in the RE-Fe-B magnets at room temperature. The purpose of this study was to investigate the possibility of control of grain refinement and magnetic anisotropy of NdFeB alloy powder by the severe plastic deformation. The NdFeB magnet powder was fabricated by gas atomization process, and the powder was pre-compacted at high temperature. The pre-compacted billets were deformed by HPT (high pressure torsion), and then the deformed billets were observed microstructure and magnetic properties. After the HPT process at room temperature, the grain size decreased with increasing because of the melted Nd-rich phase, and the anisotropy of Nd2Fe14B phase was formed after the HPT process.

진행성 위암의 추적 관찰 도중 다발성 수막내 전이가 발견된 환자 1례 (A Case of Advanced Gastric Cancer with Multiple Leptomeningeal Metastasis)

  • 신해진;정현용;문희석;성재규;강선형
    • Journal of Digestive Cancer Research
    • /
    • 제4권2호
    • /
    • pp.122-126
    • /
    • 2016
  • Leptomeningeal carcinomatosis occurs in approximately 5% of patients with cancer. The most common cancers involving the leptomeninges are breast, lung cancer and melanoma. However, gastric adenocarcinoma has been rarely reported with leptomeningeal carcinomatosis. The presenting manifestations are usually headache, visual disturbances and seizures. We report a case of leptomeningeal metastasis that presented as a gastric cancer. A 75-year old man was transferred to our hospital for further evaluation and treatment after being diagnosed with adenocarcinoma through endoscopic biopsy during a regular health examination. An abdominal computed tomography (CT) showed AGC, stage IA (cT1N0M0), while an endoscopic examination showed AGC, Borrmann type 2. The patient is currently under observation after undergoing radical subtotal gastrectomy with gastroduodenostomy and subsequent administration of oral chemotherapeutic agents. As an abdominal CT response assessment performed after surgery revealed new metastasis to the liver, the patient received palliative chemotherapy as recurrence was suspected. After receiving chemotherapy in the order of DP (Cisplatin + Docetaxel), FOLFIRI (5-FU + Leucovorin + Irinotecan), an abdominal CT response assessment showed complete response. Since decreased mentality maintained throughout the follow up period based on outpatient clinic, brain MRI was performed and revealed multiple leptomeningeal metastasis. The Patient died 2 days after the diagnosis.

  • PDF

Pearls and Potential Pitfalls for Correct Diagnosis of Ovarian Cystadenofibroma in MRI: A Pictorial Essay

  • Giacomo Avesani;Gianluca Caliolo;Benedetta Gui;Federica Petta;Camilla Panico;Viviana La Manna;Francesca Moro;Antonia Carla Testa;Giovanni Scambia;Riccardo Manfredi
    • Korean Journal of Radiology
    • /
    • 제22권11호
    • /
    • pp.1809-1821
    • /
    • 2021
  • Ovarian cystadenofibroma is a benign ovarian tumor that is characterized by a consistent percentage of masses, which remain indeterminate in ultrasonography and require magnetic resonance (MR) investigation; they may mimic borderline or malignant lesions. Three main morphologic patterns, resembling different ovarian neoplasms, can be identified in cystadenofibromas: multilocular solid lesions, unilocular cystic lesions with parietal thickening, and purely cystic masses. However, a cystoadenofibroma has typical features, such as T2-weighted hypointensity associated with no restrictions in diffusion-weighted imaging (the so-called "dark-dark appearance") and progressive post-contrast enhancement (type I perfusion curve). The purpose of this study was to review the features of ovarian cystadenofibromas in MR imaging and to suggest pearls and pitfalls regarding their correct diagnosis.

Feasibility of Simultaneous Multislice Acceleration Technique in Diffusion-Weighted Magnetic Resonance Imaging of the Rectum

  • Jae Hyon Park;Nieun Seo;Joon Seok Lim;Jongmoon Hahm;Myeong-Jin Kim
    • Korean Journal of Radiology
    • /
    • 제21권1호
    • /
    • pp.77-87
    • /
    • 2020
  • Objective: To assess the feasibility of simultaneous multislice-accelerated diffusion-weighted imaging (SMS-DWI) of the rectum in comparison with conventional DWI (C-DWI) in rectal cancer patients. Materials and Methods: This study included 65 patients with initially-diagnosed rectal cancer. All patients underwent C-DWI and SMS-DWI with acceleration factors of 2 and 3 (SMS2-DWI and SMS3-DWI, respectively) using a 3T scanner. Acquisition times of the three DWI sequences were measured. Image quality in the three DWI sequences was reviewed by two independent radiologists using a 4-point Likert scale and subsequently compared using the Friedman test. Apparent diffusion coefficient (ADC) values for rectal cancer and the normal rectal wall were compared among the three sequences using repeated measures analysis of variance. Results: Acquisition times using C-DWI, SMS2-DWI, and SMS3-DWI were 173 seconds, 107 seconds, (38.2% shorter than C-DWI), and 77 seconds (55.5% shorter than C-DWI), respectively. For all image quality parameters other than distortion (margin sharpness, artifact, lesion conspicuity, and overall image quality), C-DWI and SMS2-DWI yielded better results than did SMS3-DWI (Ps < 0.001), with no significant differences observed between C-DWI and SMS2-DWI (Ps ≥ 0.054). ADC values of rectal cancer (p = 0.943) and normal rectal wall (p = 0.360) were not significantly different among C-DWI, SMS2-DWI, and SMS3-DWI. Conclusion: SMS-DWI using an acceleration factor of 2 is feasible for rectal MRI resulting in substantial reductions in acquisition time while maintaining diagnostic image quality and similar ADC values to those of C-DWI.

MRI Findings in Trigeminal Neuralgia without Neurovascular Compression: Implications of Petrous Ridge and Trigeminal Nerve Angles

  • Hai Zhong;Wenshuang Zhang;Shicheng Sun;Yifan Bie
    • Korean Journal of Radiology
    • /
    • 제23권8호
    • /
    • pp.821-827
    • /
    • 2022
  • Objective: To determine the anatomical characteristics of the petrous ridge and trigeminal nerve in trigeminal neuralgia (TN) without neurovascular compression (NVC). Materials and Methods: From May 2017 to March 2021, 66 patients (49 female and 17 male; mean age ± standard deviation [SD], 56.8 ± 13.3 years) with TN without NVC and 57 controls (46 female and 11 male; 52.0 ± 15.6 years) were enrolled. The angle of the petrous ridge (APR) and angle of the trigeminal nerve (ATN) were measured using magnetic resonance imaging with a high-resolution three-dimensional T2 sequence. Data on the symptomatic side were compared with those on the asymptomatic side in patients and with the mean measurements of the bilateral sides in controls. Receiver operating characteristic (ROC) analysis was conducted to evaluate the performance of APR and ATN in distinguishing TN patients from controls. Results: In TN patients without NVC, the mean ± standard deviation (SD) of APR on the symptomatic side (98.40° ± 19.75°) was significantly smaller than that of the asymptomatic side (105.59° ± 22.45°, p = 0.019) and controls (108.44° ± 15.98°, p = 0.003). The mean ATN ± SD on the symptomatic side (144.41° ± 8.92°) was significantly smaller than that of the asymptomatic side (149.67° ± 8.09°, p = 0.003) and controls (150.45° ± 8.48°, p = 0.001). The area under the ROC curve for distinguishing TN patients from controls was 0.673 (95% confidence interval [CI]: 0.579-0.758) for APR and 0.700 (CI: 0.607-0.782) for ATN. The sensitivity and specificity using the diagnostic cutoff yielding the highest Youden index were 81.8% (54/66) and 49.1% (28/57), respectively, for APR (with a cutoff score of 94.30°) and 65.2% (43/66) and 66.7% (38/57), respectively, for ATN (cutoff score, 148.25°). Conclusion: In patients with TN without NVC, APR and ATN were smaller than those in controls, which may explain the potential cause of TN and provide additional information for diagnosis.

The Short-term Outcomes of Physiotherapy for Patients with Acetabular Labral Tears: An Analysis according to Severity of Injury in Magnetic Resonance Imaging

  • Makoto Kawai;Kenji Tateda;Yuma Ikeda;Ima Kosukegawa;Satoshi Nagoya;Masaki Katayose
    • Hip & pelvis
    • /
    • 제34권1호
    • /
    • pp.45-55
    • /
    • 2022
  • Purpose: The aim of this study was to evaluate the short-term outcome of physiotherapy in patients with acetabular labral tears and to assess the effectiveness of physiotherapy according to the severity of the labral tear. Materials and Methods: Thirty-five patients who underwent physiotherapy for treatment of symptomatic acetabular labral tears were enrolled. We evaluated the severity of the acetabular labral tears, which were classified based on the Czerny classification system using 3-T MRI. Clinical findings of microinstability and extra-articular pathologies of the hip joint were also examined. The International Hip Outcome Tool 12 (iHOT12) was use for evaluation of outcome scores pre- and post-intervention. Results: The mean iHOT12 score showed significant improvement from 44.0 to 73.6 in 4.7 months. Compared with pre-intervention scores, significantly higher post-intervention iHOT12 scores were observed for Czerny stages I and II tears (all P<0.01). However, no significant difference was observed between pre-intervention and post-intervention iHOT12 scores for stage III tears (P=0.061). In addition, seven patients (20.0%) had positive microinstability findings and 22 patients (62.9%) had findings of extra-articular pathologies. Of the 35 patients, eight patients (22.9%) underwent surgical treatment after failure of conservative management; four of these patients had Czerny stage III tears. Conclusion: The iHOT12 score of patients with acetabular labral tears was significantly improved by physiotherapy in the short-term period. Improvement of the clinical score by physiotherapy may be poor in patients with severe acetabular labral tears. Determining the severity of acetabular labral tears can be useful in determining treatment strategies.

최대강도투사를 이용한 관찰 위치와 거리에 최적화 된 입체 자기공명 뇌 혈관영상 재구성 (Reconstruction of Stereo MR Angiography Optimized to View Position and Distance using MIP)

  • 신석현;황도식
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권1호
    • /
    • pp.67-75
    • /
    • 2012
  • 목적 : 뇌에 분포하는 동맥혈관을 관찰할 때 흔히 자기공명 뇌혈관 데이터(Magnetic Resonance Angiography, MRA)를 이용한다. 하지만 뇌혈관 데이터의 경우 관찰하고자 하는 부위의 혈관을 직접적으로 관찰하기 어렵다. 이러한 3차원 데이터를 2차원 디스플레이 장치에 나타내기 위해 최대강도투사(Maximum Intensity Projection, MIP) 영상이 흔히 이용된다. 데이터의 투사방향에 위치한 복셀들 중 최대값을 가지는 복셀을 투사하여 최대강도투사 영상을 얻게 된다. 혈관의 경우 큰 복셀값을 가지기 때문에 영상에서 밝게 나타난다. 하지만 투사방향에 중첩되어 있는 일부 혈관들이 투사하는 과정에서 최대값을 가지는 혈관들에 가려져 나타나지 않게 되기 때문에 깊이 정보를 잃게 된다. 또한 정해진 위치에서의 투사영상 밖에 얻을 수 없다는 단점이 있다. 본 논문에서는 기존의 최대강도투사 영상이 가지는 이러한 단점들을 개선하여 뇌혈관의 분포를 3차원 공간상에서 최적화 된 입체영상으로 보는 새로운 방법을 제안하였다. 대상 및 방법 : 우리는 4개의 채널 코일과 3.0T 자기공명영상장치 (Siemens Tim Trio MRI scanner)를 이용하여 피험자의 머리를 고정시키고 3차원 위상대조 (Phase-Contrast, PC) 시퀀스를 적용하여 3차원 뇌혈관 데이터를 얻었다. 얻어진뇌혈관 데이터의 중심점을 기준으로 3차원 공간 회전 알고리즘을 적용하여 회전된 새로운 데이터를 얻은 다음 이 데이터를 기준 수평면상에 투사하여 뇌혈관에 대한 2차원 최대강도투사 영상을 구한다. 이 때 입체영상 구현을 위해 두 눈과 데이터의 중심이 이루는 수렴각에 맞게 뇌혈관 데이터를 각각 공간 회전시킨 후 투사하여 각각의 눈에 적합한 영상들을 구하고 이를 적청안경방식 (anaglyph)을 이용하여 관찰함으로써 최적의 입체감을 가지는 최대강도투사 영상을 얻는다. 결과 : 결과 영상을 살펴보면 우선 기존의 방법들에서는 불가능했던 뇌혈관 데이터의 다양한 위치에서의 최대강도투사 영상이 가능해졌다는 것을 알 수 있다. 또한 관찰자와 데이터 사이의 거리와 두 눈 사이의 거리를 고려하여 보다 사실적인 입체감을 가지는 입체 최대강도투사 영상을 얻었다. 결론적으로 관찰자가 바라보는 방향과 관찰자와 데이터 사이의 거리에 따른 최적의 입체영상을 얻을 수 있었다. 결론 : 제안하는 방법은 단일 최대강도투사 영상을 관찰자의 위치를 고려하여 입체영상으로 변환시킴으로써 최적의 입체감을 가지는 입체 투사 영상을 구하였다. 그리고 구면좌표계 상에서 뇌혈관 데이터의 다양한 투사방향에서의 최대강도투사 영상을 나타낼 수 있었다. 추후 알고리즘 최적화와 병렬연산 프로세스가 적용된다면 진단과 수술 계획에 필요한 뇌혈관의 입체 정보들을 실시간으로 제공해 줄 수 있을 것으로 예상된다.

자기공명분광법에서 TE와 Voxel 내의 대사물질 양에 따른 스펙트럼 변화 평가에 관한 연구 (Investigation of Varied MR Spectra by TE and Metabolite Amount in the Localized Voxel using the MR Cone-shape Phantom)

  • 우동철;김상수;임향숙;장건호;최보영
    • 한국의학물리학회지:의학물리
    • /
    • 제18권3호
    • /
    • pp.179-185
    • /
    • 2007
  • 본 연구는 자기공명분광법(Magnetic Resonance Spectroscopy: MRS)에 있어서 기존 개발된 Multi-Voxel Spectroscopy (MVS)을 위한 MR 원뿔형 팬톰을 Single voxel spectroscopy (SVS)용으로 개선하여 선정된 Voxel내의 대사물질의 양과 TE 변화에 따른 스펙트럼의 변화를 관찰하였다. 원뿔형 팬톰은 Voxel를 선정하는 위치에 따라서 그 안에 포함되는 대사물질의 양을 변화시킬 수 있다는 점에 착안하여 Voxel안에 포함되는 뇌대사물질의 양과 TE시간에 따른 각 대사물질(NAA, Cr, Cho, Lac 등)의 Peak에 대한 정량적인 분석을 시도하였다. 실험은 3T MRI/MRS 장비에서 이루어졌고, 데이터를 분석하는데 $jMRUI^{(R)}$라는 프로그램이 사용되었다. 실험 및 분석 결과 대체로 Echo Time (TE)가 커질수록 잡음이 감소하는 경향을 확인할 수 있었고 또한 TE가 커질수록, Voxel 안의 뇌대사물질의 양이 적을수록 각 대사물질의 peak intensity가 감소하는 것을 관찰할 수 있었다. 특히 Lactate의 경우, 정위선정된 Voxel안에 가장 많은 양의 대사물질이 포함되었을 때만 스펙트럼 분석이 가능한 정도의 Peak intensity를 얻을 수 있었고 대부분의 TE에서 분석 가능한 것으로 보아 각 대사물질의 intensity는 TE보다는 Voxel내의 대사물질의 양에 더욱 민감하다는 결론을 도출 할 수 있었고, 이러한 Lac에 대한 in vitro 데이터는 정량분석 시에 있어서 in vivo상에서 대사물질의 정량화를 하는 데 있어서 중요한 가이드라인을 제시할 것으로 예상된다. 그러나, 원뿔의 모서리 부분에 표면장력에 의하여 수많은 공기방울이 MR image상에서 관찰되고 또한 MRS상에서 그 스펙트럼을 얻을 수 없었는데 이는 앞으로 원뿔형 MRS 팬톰을 구조적, 기술적으로 더욱 개선해야 할 여지를 남겨두고 있다.

  • PDF