• Title/Summary/Keyword: tMRI

Search Result 1,247, Processing Time 0.03 seconds

Evaluation between 3.0 T vs 1.5 T MRI in Detection of Brain Metastasis using Double Dose Gd-DTPA (뇌전이 종양의 발견에 있어서 Doble dose Gd-DTPA를 이용한 3 T MRI와 1.5 T MRI간의 비교연구)

  • Chung, Woo-Suk;Kim, Hyung-Jung;Ahn, Chul-Min;Lee, Jae-Hoon;Hur, Jin;Cho, Eung-Hyuck;Chung, Tae-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.101-108
    • /
    • 2005
  • Purpose : Early detection of small brain metastases is important. The purpose of this study was to compare the detectability of brain metastases according to the size between 1.5 T and 3.0 T MRI. Materials and Methods : We reviewed 162 patients with primary lung cancer who were examined for TNM staging. After administration of double dose of Gd-DTPA, MR imaging was performed with SPGR by 3.0 T MRI and then with T1 SE sequence by 1.5 T MRI. In each patient, three readers performed qualitative assessment. Sensitivity, positive predictive value, and diagnostic accuracy were calculated in 3.0 T and 1.5 T MRI according to size. Using the signal intensity (SI) measurements between the metastatic nodules and adjacent tissue, nodule-to-adjacent tissue SI ratio was calculated. Results : Thirty-one of 162 patients had apparent metastatic nodules in the brain at either 1.5 T or 3.0 T MR imaging. 143 nodules were detected in 3.0 T MRI, whereas 137 nodules were detected at 1.5 T MRI. Six nodules, only detected in 3.0 T MRI, were smaller than 3.0 mm in dimension. Sensitivity, positive predictive value, and diagnostic accuracy in 3.0 T MRI were 100 %, 100 %, and 100 % respectively, and in 1.5 T MRI were 95.8%, 88.3%, and 85.1% respectively. SI ratio was significantly higher in the 3.0 T MRI than 1.5 T MRI (p=0.025). Conclusion : True positive rate of 3.0 T MRI with Gd-DTPA was superior to 1.5 T MRI with Gd-DTPA in detection of metastatic nodules smaller than 3.0 mm.

  • PDF

Experience with 7.0 T MRI in Patients with Supratentorial Meningiomas

  • Song, Sang Woo;Son, Young Don;Cho, Zang-Hee;Paek, Sun Ha
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.4
    • /
    • pp.405-409
    • /
    • 2016
  • Meningiomas are typically diagnosed by their characteristic appearance on conventional magnetic resonance imaging (MRI). However, detailed image findings regarding peri- and intra-tumoral anatomical structures, tumor consistency and vascularity are very important in pre-surgical planning and surgical outcomes. At the 7.0 T MRI achieving ultra-high resolution, it could be possible to obtain more useful information in surgical strategy. Four patients who were radiologically diagnosed with intracranial meningioma in 1.5 T MRI underwent a 7.0 T MRI. Three of them underwent surgery afterwards, and one received gamma knife radiosurgery. In our study, the advantages of 7.0 T MRI over 1.5 T MRI were a more detailed depiction of the peri- and intra-tumoral vasculature and a clear delineation of tumor-brain interface. In the safety issues, all patients received 7.0 T MRI without any adverse event. One disadvantage of 7.0 T MRI was the reduced image quality of skull base lesions. 7.0 T MRI in patients with meningiomas could provide useful information in surgical strategy, such as the peri-tumoral vasculature and the tumor-brain interface.

Consideration on Methods to Suppress Metal Artifacts Caused by Spinal Fusion during Spine MRI Study (척추 MRI 검사 시 척추 유합술로 인한 금속 인공물 억제 방법에 대한 고찰)

  • Se-Jong Yoo;Soon-Yong Kwon;Seong-Ho Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1123-1131
    • /
    • 2023
  • This study aimed to present a method to effectively suppress metal artifacts caused by spinal fusion surgery during spinal MRI study. For this purpose, a phantom made of spinal surgery screws was created to reproduce the metal artifact. Then, images were acquired with 1.5T and 3.0T MRI to evaluate changes in metal artifacts according to magnetic field strength. In addition, metal artifacts were evaluated by increasing the receive bandwidth to 200, 400 and 800 Hz/PX. As a result, metal artifacts occurring in images obtained from the 1.5T MRI decreased by approximately 52.2% compared to images obtained from the 3.0T MRI, showing a significant difference (p<0.05). In particular, the signal loss and signal pile up areas were reduced by approximately 52.81% and 42.71%, respectively, showing a significant effect in suppressing metal artifacts. On the other hand, when images were acquired while increasing the receive bandwidth from 200 to 800 Hz/PX, there was no significant effect, with a decrease of up to 8.93% for the 1.5T MRI and up to 10.98% for the 3.0T MRI (p>0.05). As a result of this study, increasing the receive bandwidth reduced signal loss and reduced some metal artifacts, but did not have a significant effect because it did not suppress signal pile up. However, when the magnetic field strength was reduced from 3.0T to 1.5T, signal loss and signal pile up were greatly reduced, effectively improving the metal artifact. Therefore, in order to suppress metal artifacts caused by spinal fusion surgery, study using a low magnetic field MRI can be said to be the most effective method.

Effective of Body Temperature Increasing during Brain MRI scan (MRI 검사 시 체온상승 효과: 1.5 T vs 3.0 T)

  • Kim, Myeong Seong;Lee, Jongwoong;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.49-54
    • /
    • 2017
  • As the Radiofrequency(RF) increases with the magnetic field strength, the wavelength of the RF excitation field becomes smaller, which leads to more the thermal effect in the human-body placed in the electric field. MRI scanner used was GE signa 1.5T, HDx 3.0T and Philips 3.0T with same routine clinical sequence protocol. Therefore temperature was measured before and after each scan. Taken the temperatures in the ear with ear infra-red type thermometer(Braun co). 3.0T were temperature increases more than $0.15^{\circ}C$ and GE 3.0T MRI equipment about $0.14^{\circ}C$ higher than the Philips 3.0T MRI(p<0.012). Psychogenic status was investigated by the survey respondents about their status can not just answer therefore, a little different from the expected. In our study of Thermal effect of clinical MRI with clinical protocol sequence, we found that the 3.0T in the body-temperature rise was greater than the 1.5T. Therefore, in clinical 3.0T examine the dangerous situation caused by the temperature rise occurred (burns, impaired thermoregulatory mechanism in patients with high-temperature damage, exhaustion occurs due to excessive sweating), not to appear the more watched the patient's condition with procedure.

Imaging Studies in Mouse Brain Using Clinical 3T MRI Scanner (임상용 3T MRI를 이용한 마우스 뇌의 영상)

  • Lim, Soo-Mee;Park, Eun-Mi
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.348-353
    • /
    • 2010
  • The purpose of this study was to explore the potentials of a clinical 3T MRI in mouse brains and technical adaptation and optimization. T1-weighted images (T1WI), T2-weighted images (T2WI), FLAIR (Fluid Attenuated Inversion Recovery) images, Gadolinium enhanced T1-weighted images (Gd-T1WI), Diffusion weighted images (DWI) were acquired in brain of 2 mice (weight 20~25 g) with cerebral infarction by occlusion of right middle cerebral artery, 1 hour, 24 hours, 72 hours after infarction and 1 normal mouse brain using clinical 3T MRI scanner. We analyzed differentiation of striatum, ventricle, cerebral cortex, and possibility of detection of acute cerebral infarction. We could differentiate the striatum, ventricle, cerebral cortex on T2WI and on DWI, FLAIR, T1WI, the differentiation of each anatomy of brain was not definite, but acute cerebral infarction was detected on DWI of 1 hour, 24 hours, 72 hours after infarction and on T2WI, FLAIR of 24 hours, 72 hours after infarction. Clinical 3T MRI can be used in differentiation of anatomy of mouse brains and DWI can be helpul in detection of acute cerebral infarction in acute phase. With technical adaptation and optimization clinical 3T MRI can be useful tool for provide preclinical and clinical small animal studies.

Functional Magnetic Resonance Imaging and Diffusion Tensor Imaging for Language Mapping in Brain Tumor Surgery: Validation With Direct Cortical Stimulation and Cortico-Cortical Evoked Potential

  • Koung Mi Kang;Kyung Min Kim;In Seong Kim;Joo Hyun Kim;Ho Kang;So Young Ji;Yun-Sik Dho;Hyongmin Oh;Hee-Pyoung Park;Han Gil Seo;Sung-Min Kim;Seung Hong Choi;Chul-Kee Park
    • Korean Journal of Radiology
    • /
    • v.24 no.6
    • /
    • pp.553-563
    • /
    • 2023
  • Objective: Functional magnetic resonance imaging (fMRI) and diffusion tensor imaging-derived tractography (DTI-t) contribute to the localization of language areas, but their accuracy remains controversial. This study aimed to investigate the diagnostic performance of preoperative fMRI and DTI-t obtained with a simultaneous multi-slice technique using intraoperative direct cortical stimulation (DCS) or corticocortical evoked potential (CCEP) as reference standards. Materials and Methods: This prospective study included 26 patients (23-74 years; male:female, 13:13) with tumors in the vicinity of Broca's area who underwent preoperative fMRI and DTI-t. A site-by-site comparison between preoperative (fMRI and DTI-t) and intraoperative language mapping (DCS or CCEP) was performed for 226 cortical sites to calculate the sensitivity and specificity of fMRI and DTI-t for mapping Broca's areas. For sites with positive signals on fMRI or DTI-t, the true-positive rate (TPR) was calculated based on the concordance and discordance between fMRI and DTI-t. Results: Among 226 cortical sites, DCS was performed in 100 sites and CCEP was performed in 166 sites. The specificities of fMRI and DTI-t ranged from 72.4% (63/87) to 96.8% (122/126), respectively. The sensitivities of fMRI (except for verb generation) and DTI-t were 69.2% (9/13) to 92.3% (12/13) with DCS as the reference standard, and 40.0% (16/40) or lower with CCEP as the reference standard. For sites with preoperative fMRI or DTI-t positivity (n = 82), the TPR was high when fMRI and DTI-t were concordant (81.2% and 100% using DCS and CCEP, respectively, as the reference standards) and low when fMRI and DTI-t were discordant (≤ 24.2%). Conclusion: fMRI and DTI-t are sensitive and specific for mapping Broca's area compared with DCS and specific but insensitive compared with CCEP. A site with a positive signal on both fMRI and DTI-t represents a high probability of being an essential language area.

Experimental Study of Chemical Shift Artifacts at 1.5T and 3.0T MRI using Gradient Echo Pulse Sequence (GE 펄스시퀀스을 이용한 1.5T와 3.0T MRI의 화학적 이동 인공물의 실험적 연구)

  • Cheol, Kweon Dae
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.531-537
    • /
    • 2016
  • An experimental study was to use the parameter to determine the MRI artifact of chemical shift that occurs in water and fats. Scanning the image according to the encoding parameter and the bandwidth and change in 1.5T and 3.0T MRI to the SNR, we compared the CNR. In the image was confirmed that the occurrence of artefacts in the chemical shift of the water and oil. 3.0T more image artifacts in the 1.5T was confirmed that the relatively reduced. The width of the bandwidth it could be confirmed that according to the honeycombs artifacts decrease. Therefore, in order to reduce the artifacts in the MRI scan of the chemical shift runners weak field strength, is thought to be appropriate to widen the width of the bandwidth.

High-resolution MR Imaging of Carotid Atherosclerotic Plaques (경동맥 경화판의 고해상도 자기공명영상)

  • Shin, Won-Seon;Kim, Sung-Mok;Choe, Yeon-Hyeon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.97-102
    • /
    • 2012
  • High-resolution carotid MRI allows visualization of carotid atherosclerotic plaque characteristics. MRI serves as a noninvasive option for the detection of active plaque inflammation and intraplaque hemorrhage. Significant gains in signal-tonoise ratio and contrast-to-noise ratio can be obtained for carotid atheroma imaging at 3T compared with 1.5T. Normalized wall index or wall area on MRI has shown its efficacy in monitoring the response after medical therapy. $T(2)^*$ quantification in carotid plaques before and after the administration of ultrasmall superparamagnetic iron oxide particles shows difference in response to treatment according to drug doses. In conclusion, high-resolution MRI is useful in the diagnosis and monitoring of carotid atherosclerotic plaques prone to transient ischemic attack and stroke.

CT and MRI image fusion reproducibility and dose assessment on Treatment planning system (치료계획시스템에서 전산화단층촬영과 자기공명영상의 영상융합 재현성 및 선량평가)

  • Ahn, Byeong Hyeok;Choi, Jae Hyeok;Hwang, Jae ung;Bak, Ji yeon;Lee, Du hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.33-41
    • /
    • 2017
  • Objectives: The aim of this study is to evaluate the reproducibility and usefulness of the images through the fusion of CT(Computed tomography) and MRI(Magnetic resonance imaging) using a self-manufactured phantom. We will also compare and analyze the target dose from acquired images. Materials and Methods: Using a self-manufactured phantom, CT images and MRI images are acquired by 1.5T and 3.0T of different magnetic fields. The reproducibility of the size and volume of the small holes present in the phantom is compared through the image from CT and 1.5T and 3.0T MRI, and dose changes are compared and analyzed on any target. Results: 13 small hole diameters were a maximum 31 mm and a minimum 27.54 mm in the CT scan and the were measured within an average of 29.28 mm 1 % compared to actual size. 1.5 T MRI images showed a maximum 31.65 mm and a minimum 24.3 mm, the average is 28.8 mm, which is within 1 %. 3.0T MRI images showed a maximum 30.2 mm and a minimum 27.92 mm, the average is 29.41 mm, which is within 1.3 %. The dose changes in the target were 95.9-102.1 % in CT images, 93.1-101.4 % in CT-1.5T MRI fusion images, and 96-102 % in CT-3.0T MRI fusion images. Conclusion: CT and MRI are applied with different algorithms for image acquisition. Also, since the organs of the human body have different densities, image distortion may occur during image acquisition. Because these inaccurate images description affects the volume range and dose of the target, accurate volume and location of the target can prevent unnecessary doses from being exposed and errors in treatment planning. Therefore, it should be applied to the treatment plan by taking advantage of the image display algorithm possessed by CT and MRI.

  • PDF

Application of T1 Map Information Based on Synthetic MRI for Dynamic Contrast-Enhanced Imaging: A Comparison Study with the Fixed Baseline T1 Value Method

  • Dong Jae Shin;Seung Hong Choi;Roh-Eul Yoo;Koung Mi Kang;Tae Jin Yun;Ji-Hoon Kim;Chul-Ho Sohn;Sang Won Jo;Eun Jung Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1352-1368
    • /
    • 2021
  • Objective: For an accurate dynamic contrast-enhanced (DCE) MRI analysis, exact baseline T1 mapping is critical. The purpose of this study was to compare the pharmacokinetic parameters of DCE MRI using synthetic MRI with those using fixed baseline T1 values. Materials and Methods: This retrospective study included 102 patients who underwent both DCE and synthetic brain MRI. Two methods were set for the baseline T1: one using the fixed value and the other using the T1 map from synthetic MRI. The volume transfer constant (Ktrans), volume of the vascular plasma space (vp), and the volume of the extravascular extracellular space (ve) were compared between the two methods. The interclass correlation coefficients and the Bland-Altman method were used to assess the reliability. Results: In normal-appearing frontal white matter (WM), the mean values of Ktrans, ve, and vp were significantly higher in the fixed value method than in the T1 map method. In the normal-appearing occipital WM, the mean values of ve and vp were significantly higher in the fixed value method. In the putamen and head of the caudate nucleus, the mean values of Ktrans, ve, and vp were significantly lower in the fixed value method. In addition, the T1 map method showed comparable interobserver agreements with the fixed baseline T1 value method. Conclusion: The T1 map method using synthetic MRI may be useful for reflecting individual differences and reliable measurements in clinical applications of DCE MRI.