• 제목/요약/키워드: system of radiological protection

검색결과 85건 처리시간 0.028초

KS C IEC60601-1-3: 의료용 전기기기-제1-3부: 기본 안전 및 필수 성능에 관한 일반 요구사항-보조표준: 진단용 X선 장치의 방사선 방어를 적용한 진단용 방사선 발생장치의 검사기준 개선안 (Amendment of the Inspection Standard for Diagnostic Radiation Equipment Applying IEC 60601-1-3: Medical Electrical Equipment - Part 1-3: General Requirements for Basic Safety and Essential Performance - Collateral Standard: Radiation Protection in Diagnostic X-ray Equipment)

  • 박혜민;김정민;김정수;김성옥;최영민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.493-504
    • /
    • 2018
  • The diagnostic radiation equipment is managed in accordance with the "Rules for Safety Management of Diagnostic Radiation Equipment" enacted in 1995. The equipments should be inspected before use and every three years after use in accordance with the [Appendix 1] of the same rule. The inspection standard has been maintained without particular revision since enacted. But, over the past two decades new types of equipments have been manufactured and used. So, it is necessary to revise [Appendix 1] by making inspection items and inspection standards. In this study, we revised the classification system of equipments and reviewed international standards of IEC 60601 series, IEC 61223 series and AAPM TG 18 On-line Report No.03. And identified the problem of current inspection standards. Through this, we revised, deleted and added the inspection items and inspection standard of each equipment to meet the domestic circumstances. As a result of the study, we reorganized the classification system of equipment which are current classified as 5 classes into 22 classes as X-ray system etc. (7 classes), CT system etc. (5 classes) and Dental X-ray system etc. (10 classes). And then, we developed 70 inspection items for 6 types of equipments according to the reorganized classification system of equipments. The inspection items and inspection standards derived from this study have been proposed to the KCDC and will be applied to the revision of the Rule's [Appendix 1]. Therefore, we expect to be used as reference materials for domestic medical center, inspection institutions, and equipment manufacturing import companies.

다중소자 열형광선량계에 의한 수정체 등가선량 평가의 적정성 연구 (A Feasibility Study on the Lens of Eye Dose Assessment Using the System of Multi-Element TLD)

  • 이나래;한승재;이병일;조건우
    • Journal of Radiation Protection and Research
    • /
    • 제37권2호
    • /
    • pp.96-102
    • /
    • 2012
  • 2011년 국제방사선방호위원회(ICRP)는 최근 역학 조사들을 근거로 방사선영향으로 발생할 수 있는 암 외 질환의 위험에 대한 권고를 개정하였다. 특히 수정체 조직반응의 발단선량을 0.5 Gy로 하향 조정하면서, 계획 피폭상황에서 직무 피폭 시 수정체 등가선량한도를 "정해진 5년 기간 동안 평균해서 연간 20 mSv, 그 중 어느 한 해에도 50 mSv를 초과하지 않아야 한다"로 권고하였다. 방사선작업종사자의 외부선량은 개인 열형광선량계(TLD)를 사용하여 감시하고 있으며 판독한 열형광소자별 반응도를 선량평가 알고리즘에 적용하면 개인의 수정체 등가선량을 구할 수 있다. 본 논문에서는 성능검사에 사용된 Harshaw TLD의 소자반응도를 사용하여 현재 사용 중인 알고리즘들에 의한 수정체 등가선량을 평가하였다. 그 결과 성능검사에 사용된 TLD의 소자반응도를 사용하여 수정체 등가선량을 평가한 경우 알고리즘 간의 상대오차는 최대 48.84% 내에 있는 것으로 나타났다.

광자극발광선량계(OLSDs)를 이용한 직장암 방사선치료 환자의 피부선량 측정 (Measurement of Skin Dose for Rectal Cancer Patients in Radiotherapy using Optically Stimulated Luminescence Detectors (OSLDs))

  • 임인철;유윤식;이재승
    • Journal of Radiation Protection and Research
    • /
    • 제36권2호
    • /
    • pp.86-92
    • /
    • 2011
  • 본 연구는 최근 생체내선량측정에서 유용성을 재평가 받고 있는 광자극발광선량계(optically stimulated luminescence dosimeters. OSLDs)와 다이오드 검출기를 병행하여 직장암 방사선치료 환자의 피부선량을 측정하고 치료계획시스템 에서 계산 선량과 측정 선량을 비교하여 OSL 선량계의 임상적 유용성을 평가하고자 하였다. 각 OSL 선량계의 고유한 교정상수를 측정하고 10 명의 직장암 환자를 대상으로 3 부위를 설정하여 측정하였다. 기준 흡수선량 100 cGy에 대하여 OSL 선량계의 교정상수는 6 MV X-선의 경우 1.17, 10 MV X-선의 경우 1.28 이었다. 또한 직장암 환자들의 피부선량은 측정 부위별로 치료계획시스템에서 계산 선량과 비교하여 다이오드 검출기는 1.16 ~ 2.83%의 선량증가를 보였고 OSL 선량계는 1.36 ~ 2.17%의 선량증가를 보였다. 특히 피부면의 굴곡이 심한 회음부(perineum)에서 계산된 선량과 전달 선량간 차이가 증가되었으며 다이오드 검출기보다 OSL 선량계가 측정값의 변화가 상대적으로 작았다. 따라서 OSL 선량계는 기존에 사용하던 이온함 및 다이오드 검출기를 대신하여 방사선량학적 오차의 검증 및 생체내선량측정에서 임상적으로 적용이 가능하였으며 직장암 환자의 굴곡이 심한 회음부 주변의 선량 평가에 대한 연구가 계속되어야 할 것으로 판단된다.

Preliminary Application of Synthetic Computed Tomography Image Generation from Magnetic Resonance Image Using Deep-Learning in Breast Cancer Patients

  • Jeon, Wan;An, Hyun Joon;Kim, Jung-in;Park, Jong Min;Kim, Hyoungnyoun;Shin, Kyung Hwan;Chie, Eui Kyu
    • Journal of Radiation Protection and Research
    • /
    • 제44권4호
    • /
    • pp.149-155
    • /
    • 2019
  • Background: Magnetic resonance (MR) image guided radiation therapy system, enables real time MR guided radiotherapy (RT) without additional radiation exposure to patients during treatment. However, MR image lacks electron density information required for dose calculation. Image fusion algorithm with deformable registration between MR and computed tomography (CT) was developed to solve this issue. However, delivered dose may be different due to volumetric changes during image registration process. In this respect, synthetic CT generated from the MR image would provide more accurate information required for the real time RT. Materials and Methods: We analyzed 1,209 MR images from 16 patients who underwent MR guided RT. Structures were divided into five tissue types, air, lung, fat, soft tissue and bone, according to the Hounsfield unit of deformed CT. Using the deep learning model (U-NET model), synthetic CT images were generated from the MR images acquired during RT. This synthetic CT images were compared to deformed CT generated using the deformable registration. Pixel-to-pixel match was conducted to compare the synthetic and deformed CT images. Results and Discussion: In two test image sets, average pixel match rate per section was more than 70% (67.9 to 80.3% and 60.1 to 79%; synthetic CT pixel/deformed planning CT pixel) and the average pixel match rate in the entire patient image set was 69.8%. Conclusion: The synthetic CT generated from the MR images were comparable to deformed CT, suggesting possible use for real time RT. Deep learning model may further improve match rate of synthetic CT with larger MR imaging data.

IAEA의 기준모델과 MASCOT 프로그램을 이용한 중저준위방사성폐기물 천층처분시설 안전성평가 (Safety Assessment for LILW Near-Surface Disposal Facility Using the IAEA Reference Model and MASCOT Program)

  • 김현주;박주완;김창락
    • Journal of Radiation Protection and Research
    • /
    • 제27권2호
    • /
    • pp.111-120
    • /
    • 2002
  • IAEA가 제시한 중 저준위 방사성폐기물 천층처분시설 기준 안전성평가 사례에 대해 MASCOT 프로그램을 이용하여 안전성평가를 수행하였다. 이를 위해 기준시나리오에 대한 개념 모델을 개발하였다. 지질계와 생태계의 연결매체인 우물을 동한 지하수 이동경로에 대한 평가를 수행하였고 생태계 모델에서는 구획모델을 적용하여 인간활동을 통한 최종 방사선적 영향을 평가하였으며, 다른 평가 결과와의 비교를 통해 기준시나리오에 대한 개념모델의 적합성을 조사하였다. 본 연구 결과는 구획모델을 이용한 지하수 유동경로에 대한 대표적인 개념모델을 총체적인 처분시스템의 안전성평가에 만족스럽게 이용할 수 있다는 것을 보여주었다. 또한 MASCOT 프로그램을 이용하여 복잡하고 다양한 이동경로를 통한 천층처분시설의 방사선적 안전성평가가 가능함을 보였다.

A Discussion for Alteration of the Radiation Issues Based on the Clipping Analyses of Radiation Articles Reported in Korea

  • Kim, Joo Yeon;Youn, Dol Mi;Yoo, Ji Yup;Park, Tai Jin
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.161-165
    • /
    • 2016
  • Background: Radiation accidents having occurred in recent containing the accident in Fukushima nuclear power plants of Japan were resulted to the increase in some public concern, anxiety and confusion for radiation or nuclear safety. The public anxiety for radiation is not being decreased though the announcements done in radiation research institutes in Korea. Therefore, this study aims at providing an effective system for radiation publicity to the public members by the clipping analysis for the radiation articles reported in the media. And, the relation between those radiation issues and the radiation perception to the public members is analyzed. Materials and Methods: The radiation articles reported by them in 2013 and 2014 have been collected, and they are then classified with the article characteristic, field and tendency. Classified articles have been reviewed by dividing as two year. The 210 articles have been compared for their tendencies, characteristics and fields by year reported, and their characteristic comparison by reported year are then reviewed. Results and Discussion: Though the frequency that the radiological accidents have occurred in worldwide is far low compared to the accidental frequencies occurred in the general industrial fields, the radiation perception is being still deteriorated because of its special problem, which is defined as exposure, contamination or radioactivity, about radiation. The basic principles for radiation communication were suggested for preventing some unnecessary misunderstanding due to the variation of understanding for radiation issues. Conclusion: It is necessary to perform a variety of strategies for the publicity in improving the radiation perception, to build a relationship with the press or the media and then to consistently interact with them. Radiation communication must be performed by radiation experts or complete charge department, and must be consistently performed and be taken predictable patterns.

Status of Domestic and International Recommendations for Protection Design and Evaluation of Medical Linear Accelerator Facilities

  • Choi, Sang Hyoun;Shin, Dong Oh;Shin, Jae-ik;Kwon, Na Hye;Ahn, So Hyun;Kim, Dong Wook
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.83-91
    • /
    • 2021
  • Various types of high-precision radiotherapy, such as intensity-modulated radiation therapy (IMRT), tomotherapy (Tomo), and stereotactic body radiation therapy have been available since 1997. After being covered by insurance in 2015, the number of IMRT cases rapidly increased 18-fold from 2011 to 2018 in Korea. IMRT, which uses a high-beam irradiation monitor unit, requires higher shielding conditions than conventional radiation treatments. However, to date, research on the shielding of facilities using IMRT and the current understanding of its status are insufficient, and detailed safety regulation procedures have not been established. This study investigated the recommended criteria for the shielding evaluation of facilities using medical linear accelerators (LINACs), including 1) the current status of safety management regulations and systems in domestic and international facilities using medical LINACs and 2) the current status of the recommended standards for safety management in domestic and international facilities using medical LINACs. It is necessary to develop and introduce a safety management system for facilities using LINACs for clinical applications that is suitable for the domestic medical environment and corresponds to the safety management systems for LINACs used overseas.

방사선(학)과의 작업종사자와 수시출입자의 교내 실습에 따른 피폭선량에 대한 고찰 (A Study on the Exposure Dose of Workers and Frequent Workers in the Radiology Department)

  • 전성민;이용기;안성민
    • 한국방사선학회논문지
    • /
    • 제15권3호
    • /
    • pp.355-359
    • /
    • 2021
  • 본 연구에서는 교내 실습 중 방사선(학)과 에 지정된 방사선작업종사자 및 수시출입자의 피폭 정도를 분석하여 방사선(학)과에 대한 원자력안전법의 방사선 방호에 대한 타당성과 최적화에 대한 기초 연구에 목적을 두었다. 연도별 작업종사자의 평균 피폭선량 2014년과 2016년에 0.01 mSv로 가장 낮은 수치가 나타났으며. 가장 높은 수치는 2018년도로 0.12 mSv이다. 연도별 수시출입자의 평균 피폭선량은 2018년 0.013 mSv로 가장 낮은 수치를 보였으며, 2016년 0.022 mSv로 가장 높은 수치가 나타났다. 본 연구를 통하여 방사선 발생장치만을 사용하는 대학의 담당교수, 실습 조교 및 방사선(학)과의 학생들은 교내실습 과정에서 받는 연간 피폭선량은 일반인의 선량한도인 1mSv에도 미치지 못하는 수준이다. 그러므로 방사선(학)과 학생들의 피폭선량이 일반인의 선량한도 보다 낮게 나오는 시점에서 현재 원자력안전법의 안전규제는 과도한 규제라고 판단된다. 따라서 현재의 원자력안전법에서 방사선 발생장치의 규정을 개정하거나 대학의 재학생에 대한 방사선안전관리 체계를 수정하는 것은 필요하다고 사료된다.

소아 흉부촬영 시 나이와 체격에 따른 입사피부선량 (Entrance Skin Dose According to Age and Body Size for Pediatric Chest Radiography)

  • 신귀순;민기열;김두한;이광재;박지환;이귀원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권4호
    • /
    • pp.327-334
    • /
    • 2010
  • 전리방사선의 피폭에 의한 암 유발확률은 소아가 성인에 비해 크기 때문에 소아 X선 검사 시의 환자선량을 정확히 파악하는 일은 중요하다. 그러나 우리나라는 소아 환자선량에 대한 연구가 활발하지 않다. 그러므로 본 연구에서는 7세 미만 소아를 대상으로 전리함을 이용하여 흉부검사 시의 입사피부선량(entrance skin dose, ESD)을 측정하여 나이, 키, 체중, 가슴두께와 ESD의 관계를 비교한 결과는 다음과 같았다. 소아는 나이에 따라서 키, 체중 및 가슴두께가 비슷한 양상으로 증가하므로, 흉부촬영 시 측정하기 힘든 가슴두께 대신에 나이에 따라서 촬영조건을 설정해도 무방함을 알 수 있었다. 2세 미만 소아의 흉부 A-P 검사 시, kVp는 A병원에서 더 높았으나, mAs는 반대로 B병원에서 높아, ESD 값이 B병원에서 약 1.7배 높았다. 그러나 4세 이상 소아의 흉부 P-A 검사 시에는 mAs는 같았고 kVp는 B 병원에서 7 kVp 높았으나, ESD값은 FID가 먼 B병원(180 cm)에서보다 더 가까운 A병원(130 cm)에서 1.4배 정도 높았다. 또한 같은 나이라도 A-P가 P-A보다 ESD값이 높았다. 나이별에 따른 ESD값을 보면, 1세 미만은 $154{\mu}Gy$, 1세에서 4세 미만은 $194{\mu}Gy$, 4세에서 7세 미만은 $138{\mu}Gy$으로 나타났다. 이 값은 일본의 JART의 권고량($200{\mu}Gy$)보다 낮으나, EC(유럽위원회)나 영국의 NRPB의 권고량보다 높으며, 2009년 12월에 식품의약품안전평가원에 제출된 용역보고서의 진단참고준위(5세 소아에서의 중간값이 $100{\mu}Gy$)보다 높다. 결론적으로 ESD는 X선장치 시스템의 차이보다는 방사선사의 경험적 실행에 의한 촬영조건의 차이에 의해서 크게 달라짐을 알 수 있었으며, 또한 나이가 많다고 더 많은 선량을 받는 것은 아니다. 따라서 나이에 따른 소아의 적정 참고준위의 확립과 점진적인 환자선량의 저감화가 반드시 필요하다.

두부규격방사선촬영장치의 두경부 피폭 저감에 대한 연구 (Study on Research for Reducing Radiation Dose of Head and Neck for Cephalometric Radiography System)

  • 오윤진;신재원;이삼열
    • 한국방사선학회논문지
    • /
    • 제10권5호
    • /
    • pp.291-298
    • /
    • 2016
  • 최근 국민의 소득수준 증가에 따른 소아의 교정치료 등의 관심이 커지면서 치과방사선 검사의 건수가 증가하고 있어 부정교합 및 악골과 치아의 위치변화 등을 관찰할 수 있는 두부규격방사선촬영이 빈번해지고 있다. 특히 검사 대상자가 방사선에 더욱 민감한 소아 층에 집중되어 있고 촬영 부위인 두경부에는 갑상선, 골수, 안구, 타액선 등의 방사선에 민감한 주요 장기가 위치하고 있어 피폭의 주의가 요구된다. 이에 따라 본 연구에서는 Agfa CP-G Plus 필름과 MagicMax 선량계를 이용하여 두경부규격방사선촬영장치(VATEC Pax-400C)에서 발생되는 X선의 2차원 선량분포를 측정하고 MCNPX 시뮬레이션을 통해 두경부 장기선량을 계산하였으며 피폭저감 장치를 설계하였다. 두부규격방사선촬영의 선량분포는 구강악안면의 검사 목적 부위 이외에도 두경부 전체적인 피폭이 일어나고 두경부 주요 장기 중 갑상선과 식도, 눈에서 높은 피폭선량 값을 확인하였다. 그리고 설계한 피폭저감 장치를 적용에 따라 갑상선과 식도, 눈에서 70~80% 피폭이 저감됨을 확인하였다. 본 연구 결과는 치과방사선에 대한 선량 데이터 확보와 방사선 피폭 저감 연구에 있어 매우 유용하게 이용될 것으로 기대된다.