• Title/Summary/Keyword: system of radiological protection

검색결과 85건 처리시간 0.02초

Comparison between a 13-session and One-time Program on Korean Elementary, Middle and High School Students' Understanding of Nuclear Power

  • Han, Eun Ok;Choi, YoonSeok;Lim, YoungKhi
    • Journal of Radiation Protection and Research
    • /
    • 제42권1호
    • /
    • pp.56-62
    • /
    • 2017
  • Background: To help future generations make accurate value judgments about nuclear power generation and radiation, this study will provide an effective education plan suitable for South Korea by applying and analyzing programs for the understanding of nuclear power within the diversely operated programs in the current Korean education system. Materials and Methods: This study analyzed the difference in educational effects by operating a 13-session regular curriculum for one semester and a one-session short-term curriculum from March to July 2016. Results and Discussion: As a result of operating a 13-session model school and a one-time educational program to analyze behavior changes against the traditional learning model, it was found that all elementary, middle and high school students showed higher acceptability of nuclear power in South Korea. The variation was greater for the model school than the short-term program. Conclusion: To prevent future generations from making biased policy decisions stemming from fear regarding nuclear power, it is necessary to bolster their value judgments in policy decisions by acquiring sufficient information about nuclear power generation and radiation through educational programs.

시험소각결과에 기준한 한국원자력연구소 소각시설의 방사학적 안전성 평가 (Radiological Safety Assessment for KAERI Incineration Plant on the Basis of Trial Burn Results)

  • 양희철;김봉환;김창회;박원만;정명수
    • Journal of Radiation Protection and Research
    • /
    • 제23권2호
    • /
    • pp.109-114
    • /
    • 1998
  • 모의 및 실폐기물 시험소각 결과를 기준으로 한국원자력연구소 소각시설의 상용운전을 위한 방사학적 위해성을 평가하였다. 연간 정상운전을 통해 배출되는 방사성 물질로 인한 환경영향은 물론 가상된 사고시의 단기(2시간 기준) 배출로 인한 환경적 영향은 무시할 수 있을 것으로 평가되었으나 정상운전시에 배출되는 주배출원인 반휘발성 방사성 세슘의 농도는 공기중 허용농도의 10%를 약간 상회하는 것으로 평가되었다. 비방사능 세슘추적자를 포함하는 모의폐기물의 시험소각을 통하여 포대 여과기의 응축상 세슘성분에 대한 제거특성을 고찰하였다. 포대여과장치를 통과하기전 배기체내에 확산과 관성의 전이영역에 분포하는 입자상 세슘성분은 5%에 불과하였다. 포대여과기의 세슘성분에 대한 총괄제거효율이 99.9% 이상이어서 방사성폐기물 소각설비의 저온 배기체처리계통의 일차 여과장치로서 충분한 제염성능을 가짐을 보였다.

  • PDF

Comparison of Characteristics of Gamma-Ray Imager Based on Coded Aperture by Varying the Thickness of the BGO Scintillator

  • Seoryeong Park;Mark D. Hammig;Manhee Jeong
    • Journal of Radiation Protection and Research
    • /
    • 제47권4호
    • /
    • pp.214-225
    • /
    • 2022
  • Background: The conventional cerium-doped Gd2Al2Ga3O12 (GAGG(Ce)) scintillator-based gamma-ray imager has a bulky detector, which can lead to incorrect positioning of the gammaray source if the shielding against background radiation is not appropriately designed. In addition, portability is important in complex environments such as inside nuclear power plants, yet existing gamma-ray imager based on a tungsten mask tends to be weighty and therefore difficult to handle. Motivated by the need to develop a system that is not sensitive to background radiation and is portable, we changed the material of the scintillator and the coded aperture. Materials and Methods: The existing GAGG(Ce) was replaced with Bi4Ge3O12 (BGO), a scintillator with high gamma-ray detection efficiency but low energy resolution, and replaced the tungsten (W) used in the existing coded aperture with lead (Pb). Each BGO scintillator is pixelated with 144 elements (12 × 12), and each pixel has an area of 4 mm × 4 mm and the scintillator thickness ranges from 5 to 20 mm (5, 10, and 20 mm). A coded aperture consisting of Pb with a thickness of 20 mm was applied to the BGO scintillators of all thicknesses. Results and Discussion: Spectroscopic characterization, imaging performance, and image quality evaluation revealed the 10 mm-thick BGO scintillators enabled the portable gamma-ray imager to deliver optimal performance. Although its performance is slightly inferior to that of existing GAGG(Ce)-based gamma-ray imager, the results confirmed that the manufacturing cost and the system's overall weight can be reduced. Conclusion: Despite the spectral characteristics, imaging system performance, and image quality is slightly lower than that of GAGG(Ce), the results show that BGO scintillators are preferable for gamma-ray imaging systems in terms of cost and ease of deployment, and the proposed design is well worth applying to systems intended for use in areas that do not require high precision.

흰쥐의 전립선에 대한 셀레늄(Se)의 방사선 방호효과 (Radiation Protection Effect of Selenium on the Rat's Prostate)

  • 최형석;최준혁;정도영;김장오;신지혜;김주희;민병인
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권2호
    • /
    • pp.317-322
    • /
    • 2017
  • 첨단 의료 장비의 보급으로 의료 분야의 방사선 활용도가 증가하면서 천연물을 활용한 방사선 방호제 연구는 사회적으로 중요한 과제가 되고 있다. 천연물인 셀레늄(Se)이 전립선에서 높게 발현되며 전립선 세포에 필수적인 역할을 한다는 것으로 알려져 있다. 전립선 조직을 대상으로 셀레늄에 의한 방사선 방호 효과를 연구하기 위하여 10 Gy의 방사선을 조사 시킨 후 1, 7, 21일 기간에 따른 혈구성분 및 항산화효소(Superoxide Dismutase; SOD) 활성 변화와 조직학적 변화를 관찰하였다. 방사선조사군(Rad)에 비해 셀레늄 투여 후 방사선조사군(Se+Rad)에서 조혈면역계의 손상을 경감시키는 유의한 방호 효과가 있었다(p<0.05). 셀레늄이 항산화효소인 Superoxide Dismutase(SOD)의 활성을 증가시키는 유효한 성분이며, 방사선 조사에 의한 전립선비대증의 발현을 억제하는 효과가 있음을 확인하였다. 셀레늄이 부득이하게 수반되는 방사선 피폭으로 인한 전립선 관련 질병의 예방과 방사선 방호제로서 유용성이 있을 것이라 사료된다.

디지털 방사선의학에서의 조사선량 설정과 인지에 대한 실태 - 대구 경북지역을 중심으로 - (A Study on the Exposure Parameter and the Patient Dose for Digital Radiography System in Dae Goo)

  • 조광호;강영한;김부순
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권2호
    • /
    • pp.177-182
    • /
    • 2008
  • 디지털 시스템이 가지는 장점인 영상판 검출기의 반응 범위(dynamic range)가 상당히 넓다는 것은 필름/증감지 시스템보다 더 높은 수준의 노광 관용도를 갖기에 재촬영이 줄어들고 영상관리에 효율적이지만, 조사조건의 설정범위가 상당히 넓어 필름/증감지 시스템의 엄격한 조사조건보다 더 많은 조사선량이 환자에게 노출 될 수도 있다. 본 연구는 디지털 시스템 하에서 일반촬영 시 방사선사 개인 별 조사선량에 대한 인식과 행위실태를 파악하여 환자피폭선량을 감소시킬 수 있는 방안을 마련하고, 방사선 선량관리의 중요성을 새로이 인식하고자 하였다. 디지털 시스템 하에서 근무 중인 방사선사의 조사조건 설정과 환자피폭선량 인지 실태를 파악해 본 결과 환자의 체형이나 상태, 촬영부위에 따라 최적의 조사선량을 적용하기 보다는 영상의 농도와 업무의 편의성에 따라 조사조건이 설정되고 있었다. 디지털 시스템이 도입되며 검출기의 반응 범위가 필름/스크린 시스템보다 넓어짐에 따라 조사조건 설정에 대해 관심이 소홀한 경향이 있었다. 따라서 디지털 방사선 시스템 하에서 환자 피폭선량의 감소를 위해 최적의 조사조건으로 영상을 얻어야 할 것이다. 또한 조사선량을 최소로 하고 환자 피폭선량을 줄이기 위해 업무 습관과 인식을 새로이 할 필요성이 있고, 지속적인 관심과 주기적인 교육 및 점검, 다양한 교육 기회제공 등이 필요하다고 본다.

  • PDF

Development of a Fission Product Transport Module Predicting the Behavior of Radiological Materials during Severe Accidents in a Nuclear Power Plant

  • Kang, Hyung Seok;Rhee, Bo Wook;Kim, Dong Ha
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.237-244
    • /
    • 2016
  • Background: Korea Atomic Energy Research Institute is developing a fission product transport module for predicting the behavior of radioactive materials in the primary cooling system of a nuclear power plant as a separate module, which will be connected to a severe accident analysis code, Core Meltdown Progression Accident Simulation Software (COMPASS). Materials and Methods: This fission product transport (COMPASS-FP) module consists of a fission product release model, an aerosol generation model, and an aerosol transport model. In the fission product release model there are three submodels based on empirical correlations, and they are used to simulate the fission product gases release from the reactor core. In the aerosol generation model, the mass conservation law and Raoult's law are applied to the mixture of vapors and droplets of the fission products in a specified control volume to find the generation of the aerosol droplet. In the aerosol transport model, empirical correlations available from the open literature are used to simulate the aerosol removal processes owing to the gravitational settling, inertia impaction, diffusiophoresis, and thermophoresis. Results and Discussion: The COMPASS-FP module was validated against Aerosol Behavior Code Validation and Evaluation (ABCOVE-5) test performed by Hanford Engineering Development Laboratory for comparing the prediction and test data. The comparison results assuming a non-spherical aerosol shape for the suspended aerosol mass concentration showed a good agreement with an error range of about ${\pm}6%$. Conclusion: It was found that the COMPASS-FP module produced the reasonable results of the fission product gases release, the aerosol generation, and the gravitational settling in the aerosol removal processes for ABCOVE-5. However, more validation for other aerosol removal models needs to be performed.

세계 각국의 고준위계기물 처분안전 및 기술기준 고찰 (Investigation of the Safety and Technical Criteria for HLW Disposal in Other Countries)

  • 최종원;권상기;고원일;강철형
    • Journal of Radiation Protection and Research
    • /
    • 제26권2호
    • /
    • pp.119-132
    • /
    • 2001
  • 본 연구에서는 IAEA, OECD/NEA, ICRP등과 같은 국제기구에서 제안하는 권고기준과 고준위폐기물 처분사업을 계획하고 있는 국가의 관련기준을 비교 분석하여 현재 우리가 추구하고 있는 '고준위폐기물 기준 처분개념 설정'을 위한 안전 및 기술기준으로 도출하였다. 이 기준은 처분 안전성을 위한 일반 원칙과 기준 그리고 처분시스템의 성능요건 등으로 구분하여 작성하였다. 본 연구에서 제시된 기준들은 향후 예상되는 국가적인 기준이나 규제사항 개발에 좋은 참고자료로 사용될 수 있을 것이다. 또한 이들은 향후 국내의 심부 지질환경에 대한 특성조사 및 안전성 분석 등을 통하여 얻어지는 자료를 근거로 계속 수정될 것이다. 고준위폐기물 처분시스템의 개발 경험이 없는 우리 실정에서는 외국의 처분시스템 개발과 인허가 및 기술적 요건들의 변화과정과 원인 등을 주시하면서 우리 환경에 맞는 독자적 기술기준을 개발해 나가는 자세가 지속되어야 할 것이다.

  • PDF

휴대용 단말 기반 의료용 무선 방사선 모니터링 시스템 개발 (Development of a Portable Device Based Wireless Medical Radiation Monitoring System)

  • 박혜민;홍현승;김정호;주관식
    • Journal of Radiation Protection and Research
    • /
    • 제39권3호
    • /
    • pp.150-158
    • /
    • 2014
  • 각 의료기관 내 방사선 관련 종사자나 방사선 치료환자들은 진단 및 치료 시 필연적으로 의료상 피폭을 수반하게 된다. 국제방사선방호위원회(ICRP) 권고나 국제원자력기구(IAEA)의 기준에 따라 기준선량 제약치를 적용 및 권고 받고 있지만 1차 피폭대상자인 종사자나 환자들의 피폭최적관리를 위해서는 잠재적인 피폭대상자들에게 기존의 피폭관리 시스템보다 직접적이고 가용성이 높은 측정 및 분석 방법이 필요하다. 따라서 본 연구에서는 기존에 구비된 휴대용 단말과 연동하여 원거리에서 실시간으로 방사선 모니터링이 가능한 시스템을 개발하였다. 모니터링 시스템은 검출부, 영상부, 통신부 세 부분으로 구성되었다. 검출부는 시스템의 소형화를 위해 실리콘 광증배소자(silicon photomultiplier) 기반 섬광검출기를 설계하였으며, 영상부는 무선 CCD (charge-coupled device)카메라 모듈을 사용하여 검출부와 함께 Bluetooth 통신모듈을 통해 휴대용 단말로 측정된 방사선 정보와 영상이 전송된다. 제작된 시스템은 성능 평가를 위해 진단용 X-ray 발생장치와 $^{137}Cs$, $^{22}Na$, $^{60}Co$, $^{204}Tl$, $^{90}Sr$ 선원을 사용하였다. 측정결과를 통해 개발된 시스템은 gamma, beta, X-ray에 대해서 검출 반응성을 확인하였고, 방사선 세기에 따른 응답 선형성과 MCNPX 전산코드를 이용한 측정 거리에 따른 시스템의 검출 정확도 평가 시 3% 내외의 오차범위를 확인하였다. 본 연구의 결과는 방사선 검출 시스템 구성의 비용절감 효과와 개인피폭정도관리에 기여할 것으로 기대한다.

치과 파노라마 촬영에서 환자의 피폭선량에 관한 연구 (A Study on the Patient Exposure Doses from the Panoramic Radiography using Dentistry)

  • 박일우;정원교;황형석;임성환;이대남;임인철;이재승;박형후;곽병준;유윤식
    • 한국방사선학회논문지
    • /
    • 제7권1호
    • /
    • pp.17-24
    • /
    • 2013
  • 본 연구는 파노라마 표준 촬영에서 환자의 피폭 선량을 측정하여 방사선 생물학적 위험인자를 평가하고 환자의 피폭 선량 저감화 방안을 제시하고자 하였다. 피폭 선량의 측정 오차를 최소화하기 위하여 각 OSL 선량계의 교정상수를 구하였으며 파노라마 표준 촬영에서 간접적으로 포함되는 좌 우측 수정체와 갑상선, 직접적으로 포함되는 상 하 입술, 하악골 첨부, 촬영 중심점을 대상으로 ICRP에서 권고하는 인체 모형 표준 팬텀을 이용하여 측정하였다. 측정 결과, 촬영 중심점의 선량이 $413.67{\pm}6.53{\mu}Gy$로 최대였으며 상 하 입술의 경우 각각 $217.80{\pm}2.98{\mu}Gy$, $215.33{\pm}2.61{\mu}Gy$이었다. 또한 파노라마 표준 촬영에서 간접적으로 포함되는 좌 우측 수정체의 등가선량은 각각 $30.73{\pm}2.34{\mu}Gy$, $31.87{\pm}2.50{\mu}Gy$이었으며 하악골 첨부 및 갑상선의 등가선량은 $276.73{\pm}14.43{\mu}Gy$, $162.07{\pm}4.13{\mu}Gy$이었다. 결론적으로 측정된 피폭 선량은 방사선 생물학적 효과를 유발할 수 있었으며 치과 의료기관의 파노라마 표준 촬영에서 환자의 피폭 선량에 대한 저감화 방안으로 국제기구에서 권고하고 있는 방사선 방어 원칙에 대한 정당한 해석과 제도적 뒷받침(regulation)이 필요하다. 이에 파노라마 검사에 의한 피폭 선량은 기술적 경제적 측면뿐 만 아니라 사회적 인자를 고려하여 합리적으로 용인 가능한 수준까지 최소화하기 위한 체계화된 프로토콜의 제정과 주변 결정 장기를 방어하기 위한 방사선 보호 기구에 대한 추가적 연구가 필요할 것으로 판단되었다.

방사선학적 중재적 시술시 납유리의 방사선 방어효과에 관한 연구 (Efficacy of a Protective Grass Shield in Reduction of Radiation Exposure Dose During Interventional Radiology)

  • 장영일;송종남;김영재
    • 한국방사선학회논문지
    • /
    • 제5권5호
    • /
    • pp.303-308
    • /
    • 2011
  • 목적 : 방사선학적 중재적 시술은 순환기계 또는 소화기계 병변의 진단 및 치료 목적으로 널리 이용되고 있다. 그러나 시술과정에서 방출되는 방사선은 환자뿐만 아니라 의료진에게도 잠재적인 위험요소로 인식된다. 이에 본 연구에서는 납유리를 통하여 효과적으로 방사선 피폭을 차단할 수 있도록 하며 납유리의 설치 전후의 방사선 피폭량 측정을 통해 차폐 성능과 방사선 장해 관리를 용이하게 하고자 한다. 대상 및 방법 : 2010년 9월부터 2010년 12월까지 S병원에서 방사선학적 중재적 시술을 시행한 30명을 대상으로 하였다. 방사선 차폐를 위한 납유리는 납당량 1.6mmPb, 폭 100 cm, 두께 0.8cm 높이 100cm로 구성되어 있으며 환자와 시술자 사이에 위치하도록 하였다. 방사선량의 측정은 X-선관구로부터 50 cm, 150 cm의 거리에서 신체 부위(머리, 가슴, 골반)에 따른 방사선 피폭량을 차폐 전후로 각각 측정하였다. 결과 : 30명 중 남자 13명, 여자 17명이었으며 평균연령은 69세였다. 환자의 평균신장은 $159.7{\pm}6.7$ cm였으며 체중은 $60.3{\pm}5.9$ kg이었으며 평균 체질량지수는 $20.5{\pm}3.0$ kg/m2였다. X-선관구로부터의 출력량은 환자 개개인의 체질량지수와 강한 양의 상관 관계를 나타내었다(r=0.749, p=0.001). X-선관구로부터 50 cm에서의 방사선 피폭량은 차폐 전 $1530.2{\pm}550.0$mR/hr, 차폐 후 $50.3{\pm}85.2$ mR/hr로 감소하였으며 150 cm에서의 방사선 피폭량은 차폐전 $170.6{\pm}60.1$ mR/hr, 차폐 후 $9.4{\pm}8.0$ mR/hr로 감소하였다. 차폐용 납유리의 사용은 머리, 가슴, 골반부위 모두에서 방사선 피폭량을 통계학적으로 의미있게 감소시켰다(p=0.0001). 결론 : 차폐용 납유리의 사용은 방사선피폭량을 감소시켰다. 의료진은 개인방호뿐만 아니라 X-선관구로부터의 원천적인 방호에도 주의를 기울여야 하겠다.